• Title/Summary/Keyword: CFD(Computational Fluid Dynamics

Search Result 2,022, Processing Time 0.03 seconds

Chine Shape Optimization for Directional Stability at High Angle of Attack (고 받음각에서의 방향 안정성 향상을 위한 Chine 형상 최적설계)

  • Park, Hyeong-Uk;Park, Mee-Young;Lee, Jae-Woo;Byun, Yung-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.825-834
    • /
    • 2008
  • Nose chine shape optimization study has been performed to maximize the directional stability at high angle of attack supersonic flow. Various chine shapes are generated using super ellipse equation. By numerically investigating the directional stability characteristics of those shapes, the baseline configuration for the shape optimization has been selected using the three-dimensional Navier-Stokes equations. The configuration is represented by the NURBS curves which can adjust the surface geometry by the control points. The response surfaces are constructed to obtain optimum shape which has high directional stability characteristics and lift-to-drag ratio. From this study, an efficient configuration design and optimization process which utilizes the parameter-based configuration generation techniques and approximation method has been established, then 29% improvement of the directional stability by strong vortexes from chine nose is accomplished.

Design/Construction and Performance Test of Hypersonic Shock Tunnel Part Ⅰ: Design Method of Hypersonic Shock Tunnel (극초음속 충격파 풍동 설계/구축 및 성능시험 Part Ⅰ: 극초음속 충격파 풍동 설계 방법)

  • Lee, Bok-Jik;Lee, Hyoung-Jin;Kim, Sei-Hwan;Jeung, In-Seuck
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.321-327
    • /
    • 2008
  • The shock tunnel as a hypersonic ground test facility was designed, constructed and its performance test was conducted to reproduce the high speed flow which the hypersonic propulsion system is encountered. The design points were understood and the conceptual design was completed using the quasi one dimensional operation analysis code. After that, the specific performance and compartment design were completed using CFD simulation as the part analysis. The facility was then constructed according to those design results and the performance test was conducted for various operation conditions. In this paper, we suggested the design method of hypersonic shock tunnel including the conceptual and performance design using theoretical analysis and the quasi 1D Multi-species computational fluid dynamics code.

Study on Optimum Installation of Fan in Standard Hanwoo Loose Barn (한우사 내 송풍팬의 최적 설치에 관한 연구)

  • Lee, Seung-Joo;Chang, Dong-Il;Choi, Yoon-Hyuck;Yang, Jae-Woong;Min, Byeong-Joo;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.350-356
    • /
    • 2010
  • The fans installed in standard Hanwoo loose barns (room size : 10 m (width) $\times$ 5 m (length)) are frequently used to reduce Hanwoo's heat stress during hot weather and to dry the wet floor. However, the most effective method of installing fans has not been suggested yet. Therefore, this study was carried out to evaluate two methods of installing fans under the ceiling of Hanwoo loose barn by using CFD (Computational Fluid Dynamics) code, FLUENT and to recommend the optimum fan installing method. The fan installation options were fan tilting angles of $45^{\circ}$ and $0^{\circ}$ (horizontal). The fans of 1 m diameter were installed at 3 m above floor. A velocity scale on 10 cm and 110 cm above floor and air flow pattern were used as the parameters to evaluate the fan installing methods. The fans tilted at $45^{\circ}$ angle produced higher wind at 10 cm and 110 cm above floor and more uniform air flow pattern, compared with the fans installed horizontally. Based on these results, fans tilted at $45^{\circ}$ angle may help to reduce Hanwoo's heat stress and will dry the floor better than fans installed horizontally. Therefore, it is suggested that the fans of 1 m diameter in a standard Hanwoo loose barn should be installed at a $45^{\circ}$ tilt angle and 3 m above floor with spacing of 5 m at the center of a room column.

Study on Design of Darrieus-type Tidal Stream Turbine Using Parametric Study (파라메트릭 스터디를 통한 조류발전용 다리우스 터빈의 설계연구)

  • Han, Jun-Sun;Hyun, Beom-Soo;Choi, Da-Hye;Mo, Jang-Oh;Kim, Moon-Chan;Rhee, Shin-Hyung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.4
    • /
    • pp.241-248
    • /
    • 2010
  • This paper deals with the performance analysis and design of the Darrieus-type vertical axis turbine to evaluate the effect of key design parameters such as number of blade, blade chord, pitch and camber. The commercial CFD software FLUENT was employed as an unsteady Reynolds-Averaged Navier-Stokes (RANS) solver with k-e turbulent model. Grid system was modelled by GAMBIT. Basic numerical methodology of the present study is appeared in Jung et al. (2009). Two-dimensional analysis was mostly adopted to avoid the barrier of massive calculation required for parametric study. It was found that the highly efficient turbine model could be designed through the optimization of design parametrrs.

A Numerical Study on Flow Field near the Roller Conveyor for Flat Panel Display (평면 디스플레이 기판 운송용 롤러 컨베이어 주위의 유동장에 관한 수치해석 연구)

  • Jeon, Hyun-Joo;Kim, Hyoung-Jin;Im, Ik-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

An Estimation on Indoor Thermal Environment by Pressurized Plenum Under Floor Air Conditioning System in Heating (난방시 가압식 바닥취출 공조방식의 실내온열환경 평가)

  • Choi, Eun-Hun;Lee, Yong-Ho;Kwon, Young-Cheol;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.92-99
    • /
    • 2010
  • The purpose of this study is to apply pressurized plenum under floor air conditioning system to office areas to understand characteristics of indoor thermal environment based on forms of diffusers. For doing this, the author conducted experiment of module measurement, and based on the results, analyzed indoor temperature distribution and velocity distribution based on direction of diffusion by using Computational Fluid Dynamics(CFD), and estimated the Predicted Mean Vote(PMV) of residents based on forms of diffusers to present the optimal air conditioning of the pressurized plenum under floor air conditioning system in heating. The results of this study are as follows. First, as for forms of diffusers, distributed diffusers rather than conical and grill diffusers were favorable in maintaining $24^{\circ}C$, the established temperature in heating, were active in velocity flowing, and were wide in a radius of diffusion. Second, as for position of pressurizing, the difference between upper and lower temperature was wider in center, lateral, and dispersed pressurizing (in order). As for velocity distribution, the velocity was more increased in lateral, center, and dispersed pressurizing(in order), indicating that dispersed pressurizing maintained uniform thermal environment. Third, as for diffusion direction, mixed direction showed less difference between upper and lower temperature and the difference in velocity between center and lateral part was 0.01m/1, indicating that it maintained uniform thermal environment. Fourth, as for the PMV of residents based on the forms of diffusers, the dispersed type showed(+) values above (0) when applied variably based on the position of diffuser, presenting thermal feeling of "being comfortable" to residents.

Evaluation of wind loads and wind induced responses of a super-tall building by large eddy simulation

  • Lu, C.L.;Li, Q.S.;Huang, S.H.;Tuan, Alex Y.;Zhi, L.H.;Su, Sheng-chung
    • Wind and Structures
    • /
    • v.23 no.4
    • /
    • pp.313-350
    • /
    • 2016
  • Taipei 101 Tower, which has 101 stories with height of 508 m, is located in Taipei where typhoons and earthquakes commonly occur. It is currently the second tallest building in the world. Therefore, the dynamic performance of the super-tall building under strong wind actions requires particular attentions. In this study, Large Eddy Simulation (LES) integrated with a new inflow turbulence generator and a new sub-grid scale (SGS) model was conducted to simulate the wind loads on the super-tall building. Three-dimensional finite element model of Taipei 101 Tower was established and used to evaluate the wind-induced responses of the high-rise structure based on the simulated wind forces. The numerical results were found to be consistent with those measured from a vibration monitoring system installed in the building. Furthermore, the equivalent static wind loads on the building, which were computed by the time-domain and frequency-domain analysis, respectively, were in satisfactory agreement with available wind tunnel testing results. It has been demonstrated through the validation studies that the numerical framework presented in this paper, including the recommended SGS model, the inflow turbulence generation technique and associated numerical treatments, is a useful tool for evaluation of the wind loads and wind-induced responses of tall buildings.

Effect of internal pressure variation on the ceramic particle separation characteristics : computer simulation (분리기 내부 압력 변화에 따른 세라믹 입자 분리 거동 전산모사)

  • 우효상;심광보;정용재
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.6
    • /
    • pp.304-308
    • /
    • 2003
  • By controlling the internal pressure in the cyclone separator, we investigated the separation charateristics of $Al_2O_3$, $Fe_2O_3$ particles with the internal pressure variation. 3-dimensional Langrangian approach was applied for the analysis of the particles separation, and then the minimum cut diameter of the separated particles and the separation rate were calculated through tracking the particle trajectories. The density of the argon gas for transporting particles was decreased corresponding the pressure decrease, consequently, caused the internal pressure drop in the cyclone separator. For that reason the finer particles were separated as the pressure was changed from an atmospheric pressure to an low pressure. Specifically, at 50 torr pressure, $Al_2O_3$ particles of the size of about 4 $\mu\textrm{m}$ and $Fe_2O_3$particles of about 3 $\mu\textrm{m}$ could be separated.

Numerical Study on the Thermal Environment of a Natural Light Based Multi-layered Plant Factory (자연광 기반 적층형 식물공장의 열환경에 대한 수치해석 연구)

  • Park, Dong Yoon;Jang, Seong-Teak;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.43-50
    • /
    • 2013
  • Recent researches on plant factory system deal with the convergence of lighting technology, agricultural technology inclusive to the high-tech industries worldwide in order to respond to the decreasing crop harvest due to global warming and abnormal weather phenomena. However, the fundamental performance standard is not currently being introduced in the case of plants factory and its commercialization is not activated because of high initial investment and operating cost. Large portion of the initial investment and operating cost of a plant factory is ascribed to artificial light sources and thermal control facilities, therefore, innovation should be provided in order to improve the economics of the plant factory. As an alternative, new plant factory could harness solar thermal and geothermal systems for heating, cooling and ventilation. In this study, a natural light dependent multi-layer plant factory's thermal environment was analyzed with two-dimensional numerical methods to elicit efficient operation conditions for optimized internal physical environment. Depending on the supply air temperature and airflow rate introduced in the facility, the temperature changes around the crops was interpreted. Since the air supplied into the plant factory does not stay long enough, the ambient temperature predicted around the plating trays was not significantly different from that of the supplied air. However, the changes of airflow rate and air flow pattern could cause difference to the temperature around the planting trays. Increasing the amount of time of air staying around the planting trays could improve energy performance in case the thermal environment of a natural light based multi-layer plant factory is considered.

Separation Analysis of a Store with Deployable Wings (날개 전개가 가능한 무장의 분리 특성해석)

  • Kim, Byeong-Kyoo;Kim, Sang-Jin;Kang, In-Mo;Kim, Myung-Seong;Lee, Seung-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.5
    • /
    • pp.381-389
    • /
    • 2007
  • 6-DOF simulation program is developed in order to increase the efficiency of the store separation analysis. This S/W is much faster than a method based on CFD(Computational Fluid Dynamics) technology, and allows the simulation of stores with fixed shape as well as with extensible wings, because it uses aerodynamic databases which are prepared beforehand. In this paper, aerodynamic databases of stores are obtained with MSAP(Multi-body Separation Analysis Program), and unsteady damping coefficients are modeled with Missile Datcom. These databases and the 6-DOF simulation program are used to predict the trajectory of an external store, while its wings are being deployed. The analysis results indicate that the safe separations of the store can be achieved not only with the wing fixed but with the wings being deployed.