• 제목/요약/키워드: CFC-11

검색결과 49건 처리시간 0.029초

Performance of A Three-Stage Condensation Heat Pump

  • Lee, Yoon-Hak;Jung, Dong-Soo;Kim, Chong-Bo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.55-68
    • /
    • 1999
  • In this study, computer simulation programs were developed for single-stage, two-stage, and three-stage condensation heat pumps and their performance with CFC11, HCFC123, HCFC141b was examined under the same external conditions. The results showed that the coefficient of performance(COP) of an optimized 'non-split type' three-stage condensation heat pump is 25-42% higher than that of a conventional single-stage heat pump. The increase in COP, however, differed among the fluids tested. The improvement in COP is largely due to the decrease in average LMTDs in condensers, which results in the decrease in thermodynamic irreversibility in heat exchange process. For the three-stage heat pump, the highest COP is achieved when the total condenser area is evenly distributed among the three condensers. For the two-stage heat pump, however, the optimum distribution of the total condenser area varies with an individual working fluid. For the three-stage system, 'splitting the condenser cooling water'for the use of intermediate and high pressure subcoolers helps increase the COP further. When the individual cooling water entering the intermediate and high pressure subcoolers is roughly 10% of the total condenser cooling water, the maximum COP is achieved showing roughly an 11% increase in COP as compared to that of the 'non-split type' heat pump.

  • PDF

고/액간 계면에 있어서 분산의 안정성에 관한 이론적 고찰 (The Theoretical Investigation on the Stability of Solid/Liquid Dispersion)

  • 김태영;조경행;남기대
    • 한국응용과학기술학회지
    • /
    • 제12권1호
    • /
    • pp.1-11
    • /
    • 1995
  • In this outline, the stability of solid/liquid dispersion was theoretically investigated the matter from all angles by using the modified DLVO theory. The stability was handled various considerations such as a production and characteristics of electrical double layer, total interaction$(V_T)$ that consisting of attractive force$(V_A)$ and repulsion$(V_R)$. coagulation, the stability ratio(W), critical flocculation concentration (cfc) and zeta potential$(\zeta)$ etc. It was possible for us to examine with the stability ratio(W), critical flocculation concentration (cfc) and zeta potential$(\zeta)$ that may estimation of stability of solid/liquid dispersion experimentally.

순수냉매의 풀비등 열전달 상관식 (Pool Boiling Heat Transfer Correlation for Pure Refrigerants)

  • 고영환;김종곤;송길홍;정동수;김영일
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.941-949
    • /
    • 2000
  • Pool boiling heat transfer coefficients (HTCs) of HCFC123, CFC11, HCFC142b, HFC134a, CFC12, HFC22, HFC125 and HFC32 on a horizontal smooth tube have been measured. The experimental apparatus is specially designed to simulate the real heat transfer tube with the use of the secondary fluid of water as a heat source rather than a conventional electric heat source. Data were taken in the order of decreasing heat flux starting at $80 ㎾/m^2\; and \;ending\; at\; 5㎾/m^2\;in\; the\; poo\;l temperature\; at\; 7^{\circ}C$, Test results showed that HTCs of HFC125, and HFC32 are 50~67% higher than those of HCFC22. It is also found that some of the popular pool boiling heat transfer correlations in the literature are not good to predict the HTCs of newly developed alternative refrigerants. A new correlation was developed by a regression analysis which is based upon the consistent data obtained in this study and it showed an excellent agreement with all experimental data having an absolute mean deviation of less than 10%.

  • PDF

연질 폴리우레탄 발포체 제조에서 발포제와 내부 온도와의 관계 (The Relationship between Blowing Agents and Inner Temperature at the Preparation of Flexible Polyurethane Forams)

  • 이석우;김진흥;김강호;양유경;안종일;명영찬
    • 한국응용과학기술학회지
    • /
    • 제16권2호
    • /
    • pp.179-185
    • /
    • 1999
  • 본 연구에서는 연질 폴리우레탄 발포제 제조에서 여러 발포제와 내부온도, 기계적 물성과의 관계에 대해서 연구, 조사하였다. 발포제로는 물을 주발포제로 하여 보조발포제는 CFC-11(trichlorofluoromethane), HCFC-114b(dichlorofluoroethane), dichloromethane, n-pentane, iso-pentane, cyclopentane을 사용하였다. 기계적 물성을 측정하기 위하여 연질 폴리우레탄 발포제의 밀도가 $0.015{\pm}0.002g/cm^3$$0.024{\pm}0.002g/cm^3$인 두 종류의 발포제를 제조하였다. 연질 폴리우레탄의 발포제의 제조시 발포제별로 내부온도를 측정하였으며, 48시간 경과 후 밀도, 인장강도, 신장율, 인열강도, 압축강도, 압축영구변형률을 측정하였다. 연구 결과 dichloromethane과 cyclopentane이 보조발포제로 가장 적합하였다.

충청남도 서산시 기온의 통계적 모형 연구 (Analysis of statistical models on temperature at the Seosan city in Korea)

  • 이훈자
    • Journal of the Korean Data and Information Science Society
    • /
    • 제25권6호
    • /
    • pp.1293-1300
    • /
    • 2014
  • 기온의 변화는 국가 정책에 여러 가지 영향을 준다. 본 연구에서는 충청남도 서산시 2003년 ~ 2012년 기온을 주위에서 쉽게 구할 수 있는 기상자료, 온실가스자료, 대기자료를 이용하여 자기회귀오차 (autoregressive error)모형으로 월별과 계절별로 분석하였다. 기온을 위한 기상자료로는, 풍속, 강수량, 일사량, 운량, 습도를 사용했고, 온실가스자료는 이산화탄소 ($CO_2$), 메탄 ($CH_4$), 아산화질소 ($N_2O$), 염화불화탄소 ($CFC_{11}$), 대기자료는 미세먼지 ($PM_{10}$), 이산화황 ($SO_2$), 이산화질소 ($NO_2$), 오존 ($O_3$), 일산화탄소 (CO)를 사용하였다. 분석 결과, 자기회귀오차모형으로 월별 기온을 39%-63% 정도 설명할 수 있다.

서울시 도로변, 터널 및 주거지역 대기 중 유해 휘발성 유기화합물의 특성 (Characteristics of Hazardous Volatile Organic Compounds (HVOCs) at Roadside, Tunnel and Residential Area in Seoul, Korea)

  • 이제승;최유리;김현수;어수미;김민영
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.558-568
    • /
    • 2011
  • Hazardous volatile organic compounds (HVOCs) have been increasingly getting concern in urban air chemistry due to photochemical smog as well as its toxicity or potential hazards. In this study, we investigated their concentrations and the properties in tunnel, urban roadside and residential area. As a result, among 36HVOCs measured in this study, BTEX (benzene, toluene, ethylbenzene, xylene) and dichlorodifluoromethane, 1,2,4-trimethylbenzene, trichlorofluoromethane were detected above the concentration of $1{\mu}g/m^3$ in every sampling site and the most abundant compound was toluene. The other compounds were detected at trace level or below the detection limit. In addition, we found that three CFCs (chlorofluorocarbons), such as CFC-12, CFC-11, CFC-113, were persistently detected because of the emission in the past. Toluene to benzene ratio (T/B) at tunnel and roadside were calculated to be 4.3~5.3 and at residential area 15.4, suggesting that the residential area had several emission sources other than car exhaust. The ratio of X/E (m,p-xylene to ethylbenzene) ratio was calculated to be 1.8~2.1 at tunnel, 1.7 at roadside and 1.2 at residential area, which means this ratio reflected well the relative photochemical reactivity between these compounds. Good correlation between m,p-xylene and ethylbenzene ($r^2$ > 0.85) were shown in every study sites. This indicated that correlation between $C_2$-alkylbenzenes were not severely affected by 3-way catalytic converter. In this study, it was demonstrated that the concentration of benzene was very low, compared with national air quality standard (annual average of $5{\mu}g/m^3$). Its concentration were $2.52{\mu}g/m^3$ in roadside and $1.34{\mu}g/m^3$ in residential area. We thought this was the result of persistent policy implementation including the reduction of benzene content in gasoline enforced on January 1, 2009.

오존파괴물질 대체 불소계 세정제의 물성 및 세정성 평가연구 (Physical Properties and Cleaning Ability of Fluoride-Type Cleaning Agents Alternative to Ozone Destruction Substances)

  • 박지나;김은중;정용우;김홍곤;배재흠
    • 청정기술
    • /
    • 제11권3호
    • /
    • pp.129-139
    • /
    • 2005
  • 불소 화합물인 TFEA (2,2,2-trifluoroethanol)와 HFE (hydrofluoroether)는 분자 내에 염소를 함유하지 않으므로 오존층을 파괴하지 않으며, HFC, HCFC계 세정제에 비하여 지구온난화 영향력도 낮고, 탄화수소계 세정제보다 열적으로 안정하여 차세대 CFC 대체세정제로 주목받고 있다. 이에 따라 본 연구에서는 CFC-113, 1,1,1-TCE, HCFC-141b 등의 오존파괴물질인 염소계 세정제와 차세대 대체세정제인 TFEA, HFE-7100, HFE-7200의 물성과 세정력을 비교 평가하고, 현재 대체세정제로사용하고 있는 IPA, methanol과의 물성, 세정력을 비교 평가하였다. 또한, TFEA를 기초로 하여 alcohols, HFEs와의 혼합 비수계세정제를 제조하고, 이들의 물리적 성질과 세정력을 측정하여 불소계 화합물의 대체세정제로서의 활용가능성을 평가하였다. 그 결과, TFEA와 HFEs는 현재 주요 기간산업에서 사용하는 다양한 오염물지릉 세정에서 염소계 세정제에 비하여 낮은 세정능력을 보여주었지만, 불소를 함유한 화합물이므로 불소함유 오일의 제거에는 우수한 세정력을 보였다. 또한 TFEA와 alcohols 또는 HFEs를 혼합하여 사용함으로써 플럭스와 절삭유에 대한 세정력을 100%까지 향상시킬 수 있어 불소계 화합물을 적절한 용제 또는 첨가제와 혼합하여 혼합세정제로 사용하면, 세정능력이 우수하고 환경친화적인 비수계세정제를 개발할 수 있을 것으로 기대되었다.

  • PDF

폴리우레탄 폼의 물성과 Cell Morphology에 대한 촉매와 발포제의 영향 (Effects of Catalysts and Blowing Agents on the Physical Properties and Cell Morphology of Polyurethane Foams)

  • 권현;이수헌;김상범;방문수;김연철
    • 공업화학
    • /
    • 제16권3호
    • /
    • pp.379-384
    • /
    • 2005
  • Polymeric 4,4'-diphenylmethane diisocyanate (PMDI), 여러 관능기와 OH 값을 가지는 7종의 폴리올, 실리콘 계면활성제, 두 종류의 촉매 그리고 세 종류의 발포제를 사용하여 폴리우레탄폼(PUF)을 제조하였다. 발포제로는 염화불화탄소(CFC-11), 염화불화탄화수소(HCFC-141b)와 불화탄화수소(HFC-365mfc)가 이용되었다. HCFC-141b를 사용한 PUF의 기초특성과 cell 구조에 대한 겔화촉매와 blowing 촉매의 영향을 조사하였다. Cell 크기는 촉매의 양에 따라 감소하였다. 겔화촉매의 경우에 밀도 변화는 거의 없지만 압축강도는 촉매양이 0에서 2 pph로 증가함에 따라 11.9에서 $12.66kg_f/cm^2$로 증가하였다. 3 종의 발포제를 이용한 PUF의 겔화시간, 밀도와 압축강도를 측정하였으며, 물리적 특성에 있어서는 큰 차이를 나타내지 않았다. 그러나 다른 두 종류의 발포계와 비교했을 때 HCFC-141b를 사용한 PUF의 cell 구조는 불균일함을 알 수 있었다.

물티슈 제조공정의 전과정 평가 (Life Cycle Assessment on Process of Wet Tissue Production)

  • 안중우
    • 청정기술
    • /
    • 제24권4호
    • /
    • pp.269-274
    • /
    • 2018
  • 본 연구에서는 물티슈 제조공정에 대한 전과정평가를 수행하였다. 물티슈 제조공정은 약액을 조제하여 부직포 원단에 투여하고 포장하는 단계로 이루어진다. 특정 업체의 실제 공정을 대상으로 투입 산출물 데이터를 수집하였고, 환경부와 해외 LCI DB를 활용하여 상 하위 흐름을 연결하여 이 공정에 대한 잠재적인 환경영향을 산출하였다. 특성화 결과, 오존층파괴 3.46.E-06 kg $CFC_{11}$, 산성화 5.11.E-01 kg $SO_2$, 자원고갈 $3.52.E+00\;1yr^{-1}$, 지구온난화 1.04.E+02 kg $CO_2$, 부영양화 2.31.E-02 kg ${PO_4}^{3-}$, 광화학산화물생성 2.22.E-02 kg $C_2H_4$, 인간독성 1.55.E+00 kg 1,4 DCB, 생태독성 5.82.E-04 kg 1,4 DCB로 나타났다. 일반적으로 제조공정의 환경영향을 줄이기 위해 공정을 개선하거나 환경영향이 적은 원자재와 포장재로 변경하는 등의 방법이 있다. LCA 결과, 공정에 사용되는 에너지가 주요이슈로 도출되었기 때문에 에너지 효율을 개선한 공정시스템 설계나 환경영향이 낮은 에너지원으로 변경하는 등의 방안이 필요하다. LCA의 특성상 이 연구결과는 사용된 LCI DB 종류에 따라 달라질 수 있고 모든 물티슈 제조공정을 대표할 수 없다.

Influence of the Inclination Angle and Liquid Charge Ratio on the Condensation in Closed Two-Phase Thermosyphons with Axial Internal Low-Fins

  • Cho, Dong-Hyun;Han, Kyu-il
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.422-428
    • /
    • 2003
  • This study concerns the performance of the heat transfer of the thermosyphons having 60, 70, 80. 90 axial internal low-fins in which boiling and condensation occurr. Water, HCFC-141b and CFC-11 have been used as the working fluids. The operating temperature, the liquid charge ratio and the inclination angle of thermosyphons have been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from experimental results. The experimental results have been assessed and compared with existing theories. As a result of the experimental investigation, it was found that the maximum heat flow rate in the thermosyphons is dependent upon the liquid charge ratio and inclination angle. A relatively high rate of heat transfer has been achieved by the thermosyphon with axial internal low-fins. The inclination of a thermosyphon has a notable influence on the condensation. In addition, the overall heat transfer coefficients and the characteristics at the operating temperature are obtained for the practical applications.