• 제목/요약/키워드: CEU

검색결과 30건 처리시간 0.025초

The Overview of CEU Development for a Payload

  • Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Park, Jong-Euk;Chang, Young-Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.797-799
    • /
    • 2006
  • The Electro-optical camera subsystem as a payload of a satellite system consists of OM (optical module) and CEU(camera electronics unit), and most performances of the camera subsystem depend a lot on the CEU in which TDI CCDs(Time Delayed Integration Charge Coupled Device) take the main role of imaging by converting the light intensity into measurable voltage signal. Therefore it is required to specify and design the CEU very carefully at the early stage of development with overall specifications, design considerations, calibration definition, test methods for key performance parameters. This paper describes the overview of CEU development. It lists key requirement characteristics of CEU hardware and design considerations. It also describes what kinds of calibration are required for the CEU and defines the test and evaluation conditions in verifying requirement specifications of the CEU, which are used during acceptance test, considering the fact that CEU performance results change a lot depending on test and evaluation conditions such as operational line rate, TDI level, and light intensity level, so on.

  • PDF

광학위성 카메라전자부 EMC 시험결과의 시스템 양립성 검토 (EMC Compatibility Analysis of CEU EMC test results in the Optical Satellite System)

  • 장재웅;김태윤;임성빈;문귀원
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.161-167
    • /
    • 2010
  • 지구관측을 위한 광학위성에 탑재되는 고해상도 영상 획득을 목적으로 하는 위성카메라의 카메라전자부(CEU : Camera Electronic Unit)는 CC(Camera Controller)와 FPA(Focal Plane Assembly), CEUP(CEU Power supply)로 구성된다. 본 논문은 광학위성 탑재체(CEU)의 전자파시험결과와 이를 토대로 한 시스템 양립성 검토결과를 설명하였다. CEU의 1차 전자파시험은 전도성 방출시험, 전도성 감응시험, 복사성 방출시험 및 복사성 감응시험을 수행하였고 2차 시험에서는 1차 시험에서 규격을 만족하지 못함으로서 시스템 성능에 중요한 영향을 미칠 수 있는 복사성 방출시험과 복사성 감응시험을 차폐제를 이용하여 기구적인 차폐를 보강 후 수행하였다. 2차 시험결과에 대한 시스템 양립성은 탑재체(CEU)에서 방출하는 노이즈의 주파수성분이 위성의 GPS/S-Band 수신 성능에 미치는 영향성을 분석하였다. 기구적인 차폐보강이 전제되었을 때, 두 수신대역 내에서 발생하고 있는 노이즈 주파수성분에 대하여 6dB 이상의 마진을 갖는 것으로 나타났다.

Haplotype Phylogeny of a 200kb Region in the Human Chromosome X Terminal Band (q28)

  • Kim, Sang-Soo
    • Genomics & Informatics
    • /
    • 제6권3호
    • /
    • pp.130-135
    • /
    • 2008
  • The haplotypes of a 200 kb region in the human chromosome X terminal band (q28) were analyzed using the International HapMap Project Phasell data, which had been collected for three analysis panels (YRI, CEU, and CHB+JPT). When multiple linkage disequilibrium blocks were encountered for a panel, the neighboring haplotypes that had crossover rate of 5% or more in the panel were combined to generate 'haploid' configurations. This resulted in 8, 7, and 5 'haploid' configurations for the panels of YRI, CEU, and CHB+JPT, respectively. The multiple sequence alignment of these 'haploids' was used for the calculation of allele-sharing distances and the subsequent principal coordinate analysis. Two 'haploids' in CEU and CHB+JPT were hypothesized as 'parental' in light of the observations that the successive recombinants of these haploids can model two other haploids in CEU and CHB+JPT, and that their configurations were consistent with those in YRI. This study demonstrates the utility of haplotype phylogeny in understanding population evolution.

Description of a novel ultrasound guided peribulbar block in horses: a cadaveric study

  • Leigh, Hannah;Gozalo-Marcilla, Miguel;Esteve, Vicente;Bautista, Alvaro Jesus Gutierrez;Gimenez, Tamara Martin;Viscasillas, Jaime
    • Journal of Veterinary Science
    • /
    • 제22권2호
    • /
    • pp.22.1-22.9
    • /
    • 2021
  • Background: Standing surgery in horses combining intravenous sedatives, analgesics and local anaesthesia is becoming more popular. Ultrasound guided (USG) peribulbar nerve block (PB) has been described in dogs and humans for facial and ocular surgery, reducing the risk of complications versus retrobulbar nerve block (RB). Objective: To describe a technique for USG PB in horse cadavers. Methods: Landmarks and PB technique were described in two equine cadaver heads (Phase 1), with computed tomography (CT) imaging confirming contrast location and spread. In Phase 2, ten equine cadaver heads were randomised to two operators naive to the USG PB, with moderate experience with ultrasonography and conventional "blind" RB. Both techniques were demonstrated once. Subsequently, operators performed five USG PB and five RB each, unassisted. Contrast location and spread were evaluated by CT. Injection site success was defined for USG PB as extraconal contrast, and for RB intraconal contrast. Results: Success was 10/10 for USG PB and 0/10 for RB (p < 0.001). Of the RB injections, eight resulted in extraconal contrast and two in the masseter muscle (p = 0.47). Conclusions: The USG PB had a high injection site success rate compared with the RB technique; however, we cannot comment on clinical effect. The USG technique was easily learnt, and no potential complications were seen. The USG PB nerve block could have a wide application for use in horses for ocular surgeries (enucleations, eyelid, corneal, cataract surgeries, and ocular analgesia) due to reduced risk of iatrogenic damage. Further clinical studies are needed.

카메라 전자부 설계 파라미터를 이용한 위성 전자광학시스템의 성능분석 (The Performance Analysis of the Satellite EOS(Electro Optical Subsystem) using the Design Parameters of Camera Electronics)

  • 공종필;허행팔;김영선;박종억
    • 항공우주기술
    • /
    • 제6권2호
    • /
    • pp.73-78
    • /
    • 2007
  • 현재 개발되고 있는 위성용 전자광학시스템의 설계 파라미터를 적용하여 알려진 식에 의해 위성의 운용고도와 자세변화에 따른 전자광학시스템의 GSD 및 라인레이트 변화관계를 살펴보았다. 그리고 고도변화에 따른 적용 가능한 라인레이트와 위성의 지상 스캔율의 차이에 의해 발생할 수 있는 성능변화 요소로서의 MTF에 대한 영향을 검토하였다. 즉 현재 개발이 진행되고 있는 카메라 전자부의 설계 파라미터를 적용하여 조정 가능한 라인레이트의 한계를 알아보고 이에 의한 성능감소 변화를 검토함으로써 현재 개발 진행되는 전자광학시스템의 카메라전자부의 설계요소에 대한 분석을 수행하였다.

  • PDF

다목적실용위성 2호 고해상도 카메라 시스템의 전기적 인터페이스 및 소프트웨어 프로토콜 예비 설계 (Preliminary Design of Electric Interface It Software Protocol of MSC(Multi-Spectral Camera) on KOMPSAT-II)

  • 허행팔;용상순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.101-101
    • /
    • 2000
  • MSC(Multispectral Camera), which will be a unique payload on KOMPSAT-II, is designed to collect panchromatic and multi-spectral imagery with a ground sample distance of 1m and a swath width of 15km at 685km altitude in sun-synchronous orbit. The instrument is designed to have an orbit operation duty cycle of 20% over the mission life time of 3 years. MSC electronics consists of three main subsystems; PMU(Payload Management Unit), CEU(Camera Electronics Unit) and PDTS(Payload Data Transmission Subsystem). PMU performs all the interface between spacecraft and MSC, and manages all the other subsystems by sending commands to them and receiving telemetry from them with software protocol through RS-422 interface. CEU controls FPA(Focal Plane Assembly) which contains TDI(Timc Delay Integration) CCD(Charge Coupled Device) and its clock drivers. PMU provides a Master Clock to synchronize panchromatic and multispectral camera. PDTS performs compression, storage and encryption of image data and transmits them to the ground station through x-band.

  • PDF

Preliminary Design of Electronic System for the Optical Payload

  • Kong Jong-Pil;Heo Haeng-Pal;Kim YoungSun;Park Jong-Euk;Chang Young-Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.637-640
    • /
    • 2005
  • In the development of a electronic system for a optical payload comprising mainly EOS(Electro-Optical Sub-system) and PDTS(Payload Data Transmission Sub-system), many aspects should be investigated and discussed for the easy implementation, for th e higher reliability of operation and for the effective ness in cost, size and weight as well as for the secure interface with components of a satellite bus, etc. As important aspects the interfaces between a satellite bus and a payload, and some design features of the CEU(Camera Electronics Unit) inside the payload are described in this paper. Interfaces between a satellite bus and a payload depend considerably on whether t he payload carries the PMU(Payload Management Un it), which functions as main controller of the Payload, or not. With the PMU inside the payload, EOS and PDTS control is performed through the PMU keep ing the least interfaces of control signals and primary power lines, while the EOS and PDTS control is performed directly by the satellite bus components using relatively many control signals when no PMU exists inside the payload. For the CEU design the output channel configurations of panchromatic and multi-spectral bands including the video image data inter face between EOS and PDTS are described conceptually. The timing information control which is also important and necessary to interpret the received image data is described.

  • PDF

Allele Frequencies of the Single Nucleotide Polymorphisms Related to the Body Burden of Heavy Metals in the Korean Population and Their Ethnic Differences

  • Eom, Sang-Yong;Lim, Ji-Ae;Kim, Yong-Dae;Choi, Byung-Sun;Hwang, Myung Sil;Park, Jung-Duck;Kim, Heon;Kwon, Ho-Jang
    • Toxicological Research
    • /
    • 제32권3호
    • /
    • pp.195-205
    • /
    • 2016
  • This study was performed to select single nucleotide polymorphisms (SNPs) related to the body burden of heavy metals in Koreans, to provide Korean allele frequencies of selected SNPs, and to assess the difference in allele frequencies with other ethnicities. The candidate-gene approach method and genome-wide association screening were used to select SNPs related to the body burden of heavy metals. Genotyping analysis of the final 192 SNPs selected was performed on 1,483 subjects using the VeraCode Goldengate assay. Allele frequencies differences and genetic differentiations between the Korean population and Chinese (CHB), Japanese (JPT), Caucasian (CEU), and African (YIR) populations were tested by Fisher's exact test and fixation index ($F_{ST}$), respectively. The Korean population was genetically similar to the CHB and JPT populations ($F_{ST}$ < 0.05, for all SNPs in both populations). However, a significant difference in the allele frequencies between the Korean and CEU and YIR populations were observed in 99 SNPs (60.7%) and 120 SNPs (73.6%), respectively. Ten (6.1%) and 26 (16.0%) SNPs had genetic differentiation ($F_{ST}$ > 0.05) among the Korean-CEU and Korean-YIR comparisons, respectively. The SNP with the largest $F_{ST}$ value between the Korean and African populations was cystathionine-${\beta}$-synthase rs234709 ($F_{ST}$: KOR-YIR, 0.309; KOR-CEU, 0.064). Our study suggests that interethnic differences exist in SNPs associated with heavy metals of Koreans, and it should be considered in future studies that address ethnic differences in heavy-metal concentrations in the body and genetic susceptibility to the body burden of heavy metals.

Chromosome 22 LD Map Comparison between Korean and Other Populations

  • Lee, Jong-Eun;Jang, Hye-Yoon;Kim, Sook;Yoo, Yeon-Kyeong;Hwang, Jung-Joo;Jun, Hyo-Jung;Lee, Kyu-Sang;Son, Ok-Kyung;Yang, Jun-Mo;Ahn, Kwang-Sung;Kim, Eug-Ene;Lee, Hye-Won;Song, Kyu-Young;Kim, Hie-Lim;Lee, Seong-Gene;Yoon, Yong-Sook;Kimm, Ku-Chan;Han, Bok-Ghee;Oh, Berm-Seok;Kim, Chang-Bae;Jin, Hoon;Choi, Kyoung-O.;Kang, Hyo-Jin;Kim, Young-J.
    • Genomics & Informatics
    • /
    • 제6권1호
    • /
    • pp.18-28
    • /
    • 2008
  • Single nucleotide polymorphisms (SNPs) are the most abundant forms of human genetic variations and resources for mapping complex genetic traits and disease association studies. We have constructed a linkage disequilibrium (LD) map of chromosome 22 in Korean samples and compared it with those of other populations, including Yorubans in Ibadan, Nigeria (YRI), Centre d'Etude du Polymorphisme Humain (CEPH) reference families (CEU), Japanese in Tokyo (JPT) and Han Chinese in Beijing (CHB) in the HapMap database. We genotyped 4681 of 111,448 publicly available SNPs in 90 unrelated Koreans. Among genotyped SNPs, 4167 were polymorphic. Three hundred and five LD blocks were constructed to make up 18.6% (6.4 of 34.5 Mb) of chromosome 22 with 757 tagSNPs and 815 haplotypes (frequency $\geq$ 5.0%). Of 3430 common SNPs genotyped in all five populations, 514 were monomorphic in Koreans. The CHB + JPT samples have more than a 72% overlap with the monomorphic SNPs in Koreans, while the CEU + YRI samples have less than a 38% overlap. The patterns of hot spots and LD blocks were dispersed throughout chromosome 22, with some common blocks among populations, highly concordant between the three Asian samples. Analysis of the distribution of chimpanzee-derived allele frequency (DAF), a measure of genetic differentiation, Fst levels, and allele frequency difference (AFD) among Koreans and the HapMap samples showed a strong correlation between the Asians, while the CEU and YRI samples showed a very weak correlation with Korean samples. Relative distance as a quantitative measurement based upon DAF, Fst, and AFD indicated that all three Asian samples are very proximate, while CEU and YRI are significantly remote from the Asian samples. Comparative genome-wide LD studies provide useful information on the association studies of complex diseases.

Design, Implementation and Testing of HF transformers for Satellite EPS Applications

  • Zahran, Mohamed
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.217-227
    • /
    • 2008
  • The electric power subsystems (EPS) of most remote sensing satellites consist of a solar array as a source of energy, a storage battery, a power management and control (PMC) unit and a charge equalization unit (CEU) for the storage battery. The PMC and CEU use high frequency transformers in their power modules. This paper presents a design, implementation and testing results of a high frequency transformer for the EPS of satellite applications. Two approaches are used in the design process of the transformer based on the pre-determined transformer specifications. The transformer is designed based on an ETD 29 ferrite core. The implemented transformer consists of one center-tapped primary coil with eleven center-tapped secondary coils. The offline calculation results and measured values of R, L for transformer coils are convergence. A test circuit for measuring the transformer parameters like voltage, current and B-H hysteresis was implemented and applied. The test results confirm that the voltage waveforms of both primary and secondary coils were as desired. No overlapping occurred between the control signal and the transformer, which was not saturated during testing even during a short circuit test of the secondary channels. The dynamic B-H loop characteristics of the used transformer cores were measured. The sample test results are given in this paper.