• Title/Summary/Keyword: CEREC

Search Result 46, Processing Time 0.018 seconds

Comparison of marginal gap of monolithic CAD/CAM-generated crowns according to the ceramic materials for CEREC system (CEREC system에서 사용하는 세라믹 소재로 가공된 CAD/CAM 전부도재관의 변연간격 비교분석)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.119-125
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the marginal gap of all-ceramic crowns fabricated by CEREC$^{(R)}$ in-office CAD/CAM system. Methods: The mandibular first molar was selected as the abutment for the experiments. Thirty working models were prepared. VITA Mark II(VM) and VITA Enamic(VE), LAVA Ultimate(LU) blocks were milled using CEREC MCXL with CEREC 3D system to construct 10 crowns for each groups. To measure marginal gap, milled restorations were examined under digital microscope with scale under 160x magnifications. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There was no significant difference in the marginal gap regarding to ceramic materials(p>0.05). Conclusion: Single crowns fabricated using CEREC in-office CAD/CAM system provided clinically acceptable marginal gap. This confirmed that the type of ceramic material used does not determine the precision of fit of a prosthesis.

Reliability, accuracy of evaluations obtained from CEREC$^{(R)}$ AC system digital impression: an in-vitro study (CEREC$^{(R)}$ AC system으로 채득된 디지털 인상의 재현성, 정확성 평가에 관한 연구)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Hae-Young;Kim, Jung-Ae;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.121-128
    • /
    • 2012
  • Purpose: The aim of this study was to determine the reliability and accuracy of measurements in digital models(CEREC$^{(R)}$ AC) compared to stone models. Methods: A master model(500B-1, Nissin Dental Product, Japan) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CEREC$^{(R)}$ AC intra-oral scanner(n=10). One examiner measured two times the intercanine, intermolar distance, dental arch length. The stone model were measured using a digital caliper. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed very good reliability. At the intra-examiner reliability of measurement, ICC at the stone and CEREC$^{(R)}$ AC model were 0.81 and 0.94. The mean difference between measurements made directly on the stone models and those made on the CEREC$^{(R)}$ AC model was 0.20~0.28mm, and was statistically significant(P=0.001). Conclusion: These in vitro studies show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

A study on Common Errors in Digital Impressions: (An Example of CEREC$^{(R)}$ AC) (디지털 인상 채득 시 흔히 발생하는 오류에 관한 연구 - CEREC$^{(R)}$ AC의 사례 중심으로 -)

  • Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: The purpose of the study was a quantitative evaluation of common errors in digital impression procedure using CEREC$^{(R)}$ AC system. Methods: Two-hundreds digital impression data comprising 174 inlays, 26 onlays by CEREC$^{(R)}$ AC in-office CAD/CAM system were obtained from a dental clinic. One evaluator assessed errors of the digital impression data and divided into five categories of errors: inappropriate scanner positioning (ISP), improper handling with a scanner (IHS), irregular powder arrangement (IPA), improper cavity preparation (ICP), and insufficient scanned data (ISD). Results: The most common errors were IPA(21%), and ISP and ISD were followed by 17% respectively. IHS was found in 14.5% of all digital impression data. ICP comprising only 6.5% was the rarest. Conclusion: Most errors were due to inaccurate manipulation with an intraoral scanner or improper cavity preparation for scanning. A deliberate manipulation to prevent common errors mentioned may deliver an optimal result in the digital impression procedure.

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).

INFLUENCE OF THREE DIFFERENT PREPARATION DESIGNS ON THE MARGINAL AND INTERNAL GAPS OF CEREC3 CAD/CAM INLAYS (세 가지 다른 인레이 와동 형태가 CEREC3 CAD/CAM의 변연 및 내면 간극에 미치는 영향)

  • Seo, Deog-Gyu;Yi, Young-Ah;Lee, Yoon;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • The aim of this study was to evaluate the marginal and internal gaps in CEREC3 CAD/CAM inlays of three different preparation designs. CEREC3 Inlays of three different preparation designs (n=10) were fabricated according to Group I-conventional functional cusp capping/shoulder preparation, Group II-horizontal reduction of cusps and Group III-complete reduction of cusps/shoulder preparation. After cementation of inlays. the bucco-lingual cross section was performed through the center of tooth. Cross section images of 20 magnifications were obtained through the stereomicroscope. The gaps were measured using the Leica application suite software at each reference point. Statistical analysis was performed using one-way ANOVA and Tukey's test (${\alpha}<0.05$). The marginal gaps ranged from 80.0 to $97.8{\mu}m$ for Group I, 42.0 to $194.8{\mu}m$ for Group II, 51.0 to $80.2{\mu}m$ for Group III. The internal gaps ranged from 90.5 to $304.1{\mu}m$ for Group I, 80.0 to $274.8{\mu}m$ for Group II, 79.7 to $296.7{\mu}m$ for Group III. The gaps of each group were the smallest on the margin and the largest on the horizontal wall. For the CEREC3 CAD/CAM inlays, the simplified designs (groups II and III) did not demonstrate superior results compared to the traditional cusp capping design (group I).

Accuracy comparison of buccal bite scans by five intra-oral scanners (구강스캐너 5종의 협측 악간관계 스캔 정확성 비교 연구)

  • Park, Ji-Man;Jeon, Jin;Heo, Seong-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.17-31
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the accuracy of the interocclusal relationship between upper and lower teeth according to the buccal interocclusal record scan using various intraoral scanner systems. Materials and Methods: The upper and lower full arch Models with normal occlusion were scanned with 5 intraoral scanners (Cerec Omnicam, CS3500, iTero, Trios, True Definition). Buccal interocclusal record scan was taken only at the left side while occlusion was intentionally raised by 1 mm, 2 mm, 3 mm, and 4 mm with metal cylinder core embedded within polyvinylsiloxane bite registration material at the right molar region. The superimposition analysis was done to evaluate overall three-dimensional deviation and cross-section analysis was done to evaluate the degree and the direction of deviation of interocclusal relationship. Results: From the superimposition study, Cerec Omnicam showed the least deviation ($165.5{\mu}m$) and CS3500 ($369.0{\mu}m$) showed the largest (P < 0.01). And the deviation was greater in 3, 4, 2 mm group than 1 mm (P < 0.01). From the cross-section study, Cerec Omnicam showed the farthest deviation ($-242.8{\mu}m$) and CS3500 showed the closest deviation ($312.5{\mu}m$) and a significantly high value was shown in 3 mm group. Conclusion: Every intraoral scanner has different accuracy in reproducing interocclusal relationship.

SURFACE ANALYSIS OF CERCE RESTORATIONS POLISHED BY DIFFERENT TECHNIQUE (연마방법에 따른 Cerec block의 표면 거칠기 비교)

  • Kim, Sung-Gwang;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.31-42
    • /
    • 1997
  • This study was performed to investigate the surface roughness of the Cerec Vita Mark II polished by various polishing techniques, compare with that of the Vintage enamel porcelain glazed by high temperature glazing technique. All of the Cerec specimen were finished with sequential use of high speed diamond burs(grit 45, 30 and $15{\mu}m$). The groups were divided into 5 groups : Group I : Cerec Vita Mark II block specimens polished with Sof-lex discs. Group II : Cerce Vita Mark II block specimens polished with Two Striper MPS. Group III : Cerce Vita Mark II block specimens polished with Enhance. Group IV : Cerce Vita Mark II block specimens polished with Porcelain laminate polishing FG kit. Group V : Vintage enamel porcelain glazed by high temperature glazing Technique. Each group was consisted of 10 specimens. The surfaces produced were examined quantitatively using a laser specular reflectance machine(Perthen RM600-s, Feinpruf Perthen GmbH., Germany) and qualitatively under SEM(JSM-5400, JEOL, Japan). The Results were as follows : 1. The arithmetic mean roughness value(Ra) in groups 1, 2, 3 and 4 was higher than that of group5. There was statistically significant difference(P<0.05). 2. The arithmetic mean roughness value(Ra) decreased in the following orders : group 1, group 2, group 4, group 3 and there was no statistically significant difference between group 1 and group 2, group 3, and group 4. There was statistically significant difference among group 1, 2, and group 3, 4 and group 5(P<0.05). 3. The maximum individual peak-to-valley-height(Rmax) decreased in the following orders : group 2, group 1, group 4, group 3, group 5 and there was no statistically significant difference between group 1 and 2, group 1 and group 4, group 3 and group 5. There was statistically significant difference among group 1, 2, and group 1, 4 and group 3, 5(P<0.05). 4. The treated surfaces of group 5 had smoother surface than that of groups 1, 2, 3, 4 with SEM.

  • PDF

A COMPARISON OF THE FIDELITY BETWEEN VARIOUS CORES FABRICATED WITH CAD/CAM SYSTEMS

  • Park, Sun-Hee;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.269-279
    • /
    • 2008
  • STATEMENT OF PROBLEM: Recently, various all-ceramic crowns fabricated with CAD/CAM systems have come into wide use in dental clinic. However, there are only few domestic studies on CAD/CAM restorations. PURPOSE: Purpose of this study was to compare the fidelity (absolute marginal discrepancy and internal gap) between various cores fabricated with different CAD/CAM systems (Procera system, Lava system, Cerec inLab system) and conventional metal cast core. MATERIALS AND METHODS: 10 cores per each system were fabricated. The absolute marginal discrepancies were measured using measuring microscope and digital counter. The internal gaps were calculated using a silicone paste. The results were statistically analyzed using the one-way ANOVA test and Tukey's HSD test. RESULTS: Within the limits of this study the results were as follows. 1. The absolute marginal discrepancies were $32.5{\pm}3.7\;{\mu}m$ for metal cast core, $72.2{\pm}7.0\;{\mu}m$ for Procera core, $40.8{\pm}5.4\;{\mu}m$ for Lava core, and $55.3{\pm}8.7\;{\mu}m$ for Cerec inLab core. The internal gaps were $38.4{\pm}5.7\;{\mu}m$ for metal cast core, $71.4{\pm}5.3\;{\mu}m$ for Procera core, $45.9{\pm}7.3\;{\mu}m$ for Lava core, and $51.8{\pm}6.2\;{\mu}m$ for Cerec inLab core. 2. The fidelity of metal cast core showed the smallest gaps, followed by Lava core, Cerec inLab core, and Procera core. CONCLUSION: The fidelities of 4 core groups were all within the clinically acceptable range ($120\;{\mu}m$).

Clinical Experiment Results of Cerec Inlab using Vita9 (VITA VM9 Zirconia powder를 이용한 Cerec inlab의 임상증례에 관하여)

  • Jung, Hyo-Kyung;kim, Jeong-Sook;Lee, Jong-Do
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.119-128
    • /
    • 2007
  • Although there are many different ways that restorations can be made, it can be said that the biocompatibility of abutment and crown is very important in this experiment. When placed in the actual oral cavity, the differences were obvious. Compared to In-ceram Aluminium, the structure that is obtained after firing reveals a particularly homogeneous distribution of the crystal and glass phase. The In-ceram aluminium system had many problems, such as having weak tensile strength, and having low bonding strength due to the shrinking that occurs after firing. Because of the opaque finish of the metal frame, the two may look similar from the outside, but it is evident that there are differences between using a metal frame and In-ceram. VITA VM9 has been designed as a special ceramic featuring a fine structure or stabilized Zro2 substructures, and so the VITA VM9 excels in its light refraction and reflection behavior, which is similar to natural teeth. It also has outstanding chemical balance, which presents advantages such as considerably reduced accumulation of plaque on the ceramic surface.? This ultimately results in easier care and cleaning for the patient.

  • PDF