• Title/Summary/Keyword: CCTV-10

Search Result 784, Processing Time 0.026 seconds

A Study on Audience Counting Method in Auditorium Based on Pattern Comparison (패턴비교를 이용한 공연장에서의 관객 수 카운팅 방법에 관한 연구)

  • Sim, Sang-Kyun;Park, Young-Kyung;Kim, Joong-Kyu
    • The KIPS Transactions:PartB
    • /
    • v.14B no.1 s.111
    • /
    • pp.13-22
    • /
    • 2007
  • In this paper, we propose an audience counting method in an auditorium based on pattern comparison. The previous counting methods based on object detection can't exactly count the audience in real time because auditorium has coarse illumination condition and so many audiences. Therefore, in this paper, we count the audience in an auditorium with fixed seats by the method which the pattern from each reference seat is compared to the pattern from each input seat. Especially, to overcome limitations based on either illumination or noise, two pattern comparison methods are efficiently employed and combined. One is based on the amplitude projection, and the other is based on Walsh-Hadamard Kernel. Walsh-Hadamard Kernel has the characteristic which complements amplitude projection. Therefore, we ran achieve the accurate counting in the presence of coarse illumination and noise. The experimental results show that our method performs well on sequences of images acquired in an auditorium. We also verify a realistic possibility for other applications applying our method to the parking positioning system.

Multiple Object Tracking and Identification System Using CCTV and RFID (감시 카메라와 RFID를 활용한 다수 객체 추적 및 식별 시스템)

  • Kim, Jin-Ah;Moon, Nammee
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.2
    • /
    • pp.51-58
    • /
    • 2017
  • Because of safety and security, Surveillance camera market is growing. Accordingly, Study on video recognition and tracking is also actively in progress, but There is a limit to identify object by obtaining the information of object identified and tracked. Especially, It is more difficult to identify multiple objects in open space like shopping mall, airport and others utilized surveillance camera. Therefore, This paper proposed adding object identification function by using RFID to existing video-based object recognition and tracking system. Also, We tried to complement each other to solve the problem of video and RFID based. Thus, through the interaction of system modules We propose a solution to the problems of failing video-based object recognize and tracking and the problems that could be cased by the recognition error of RFID. The system designed to identify the object by classifying the identification of object in four steps so that the data reliability of the identified object can be maintained. To judge the efficiency of this system, this demonstrated by implementing the simulation program.

A Multicast-Based Handover Scheme for the IEEE WAVE Networks (IEEE WAVE 네트워크를 위한 멀티캐스트 기반 핸드오버 기법)

  • Lee, Hyuk-Joon;Yoon, Seok-Young;Lee, Sang-Joon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.2
    • /
    • pp.112-121
    • /
    • 2011
  • The IEEE WAVE standard specification does not support handover operation since it is designed to transmit mainly the ITS-related messages that are limited in length. More advanced multimedia applications such as Internet browsing and streaming of video clips produced by CCTVs, however, require handover support such that a sequence of data packets can be received seamlessly while an OBU's association with the RSUs changes. This paper presents a new handover scheme that can operate without performance degradation in the cases where there are multiple RSUs in the areas of handover by making use of the IEEE 802.11f IAPP Move-notify messages, based on the fast handover scheme with proactive caching by disassociation messages introduced previously. Experimental results from the simulation shows that the proposed handover scheme outperforms the scheme based solely on multicast.

Error Rate Analysis according to Setting of the Reference Point for Calculating the Flood Runoff that using Surface Image Velocimeter (SIV) (표면영상유속계(SIV)를 활용한 홍수유출량 산정 시 참조점 설정에 따른 오차율 분석)

  • Kim, Yong-Seok;Yang, Sung-Kee
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.799-815
    • /
    • 2016
  • In this study, according to the reference setting based on the runoff video of 9:00 where the highest water level of 3.94 m has been recorded during the runoff of Cheon-mi Stream in Jeju Island by the attack of Typhoon no. 16 Sanba on September $17^{th}$, 2012, the error rate of long-distance and short-distance velocimetry and real-distance change rate by input error have been calculated and the input range value of reference point by stream has been suggested. In the reference setting process, if a long-distance reference point input error occurs, the real-distance change rate of 0.35 m in the x-axis direction and 1.35 m in y-axis direction is incurred by the subtle input error of 2~11 pixels, and if a short-distance reference point input error occurs, the real-distance change rate of 0.02 m in the x-axis direction and 0.81 m in y-axis direction is incurred by the subtle input error of 1~11 pixels. According to the long-distance reference point setting variable, the velocity error rate showed the range of fluctuation of at least 14.36% to at most 76.06%, and when calculating flux, it showed a great range of fluctuation of at least 20.48% to at most 78.81%.

IoT Enabled Smart Emergency LED Exit Sign controller Design using Arduino

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.76-81
    • /
    • 2017
  • This paper presents a low cost and flexible IoT enabled smart LED controller using Arduino that is used for emergency exit signs. The Internet of Things (IoT) is become a global network that put together physical objects using network communications for the purpose of inter-communication of devices, access information on internet, interaction with users as well as permanent connected environment. A crucial point in this paper, is underlined on the potential key points of applying the Arduino platform as low cost, easy to use microcontroller with combination of various sensors applied in IoT technology to facilitate and establishment of intelligent products. To demonstrate the feasibility and effectiveness of the system, devices such as LED strip, combination of various sensors, Arduino, power plug and ZigBee module have been integrated to setup smart emergency exit sign system. The general concept of the proposed system design discussed in this paper is all about the combination of various sensor such as smoke detector sensor, humidity, temperature sensor, glass break sensors as well as camera sensor that are connected to the main controller (Arduino) for the purpose of communicating with LED exit signs displayer and dedicated PC monitors from integrated system monitoring (controller room) through gateway devices using Zig bee module. A critical appraisal of the approach in the area concludes the paper.

Building Control Box Attached Monitor based Color Grid Recognition Methods for User Access Authentication

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Khudaybergenov, Timur;Kim, Min Soo;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • The secure access the lighting, Heating, ventilation, and air conditioning (HVAC), fire safety, and security control boxes of building facilities is the primary objective of future smart buildings. This paper proposes an authorized user access to the electrical, lighting, fire safety, and security control boxes in the smart building, by using color grid coded optical camera communication (OCC) with face recognition Technologies. The existing CCTV subsystem can be used as the face recognition security subsystem for the proposed approach. At the same time a smart device attached camera can used as an OCC receiver of color grid code for user access authentication data sent by the control boxes to proceed authorization. This proposed approach allows increasing an authorization control reliability and highly secured authentication on accessing building facility infrastructure. The result of color grid code sequence received by the unauthorized person and his face identification allows getting good results in security and gaining effectiveness of accessing building facility infrastructure. The proposed concept uses the encoded user access authentication information through control box monitor and the smart device application which detect and decode the color grid coded informations combinations and then send user through the smart building network to building management system for authentication verification in combination with the facial features that gives a high protection level. The proposed concept is implemented on testbed model and experiment results verified for the secured user authentication in real-time.

Performance Evaluation on the Pipelines for an Automated Vacuum Waste Collection System (생활폐기물 자동집하시설 이송관망 성능평가)

  • Jang, Choon-Man;Lee, Sang-Moon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.26-32
    • /
    • 2015
  • This paper describes performance evaluation of design parameters, air velocity inside a pipeline and pressure along a pipeline, using experimental measurements in an automated vacuum waste collection system. Automatic robot having six cameras is introduced to analyze the internal pipeline conditions whether waste accumulates at the bottom of the pipeline or not. Throughout the experimental measurements of the pipeline having the various shapes, it is found that pressure and internal air velocity linearly increase along the pipeline from a waste inlet to a waste collection station while air density decreases due to the air compression effect with high pressure. Although air velocity inside the pipeline at a waste inlet keeps design velocity range between 20 m/s and 30 m/s, it is noted that air velocity near the waste collection station exceeds maximum design velocity of 30 m/s. Pressure increase per unit length is changed from 17.6 Pa/m to 18.9 Pa/m, which depends on the air velocity inside the pipeline. From the investigation inside the pipeline with CCTV loaded on an automated robot, waste accumulated at the bottom of the pipeline is mainly found at the downstream of a circular curved pipe, an inclined pipe and a bended pipe.

Violent Behavior Detection using Motion Analysis in Surveillance Video (감시 영상에서 움직임 정보 분석을 통한 폭력행위 검출)

  • Kang, Joohyung;Kwak, Sooyeong
    • Journal of Broadcast Engineering
    • /
    • v.20 no.3
    • /
    • pp.430-439
    • /
    • 2015
  • The demand of violence detection techniques using a video analysis to help prevent crimes is increasing recently. Many researchers have studied vision based behavior recognition but, violent behavior analysis techniques usually focus on violent scenes in television and movie content. Many methods previously published usually used both a color(e.g., skin and blood) and motion information for detecting violent scenes because violences usually involve blood scenes in movies. However, color information (e.g., blood scenes) may not be useful cues for violence detection in surveillance videos, because they are rarely taken in real world situations. In this paper, we propose a method of violent behavior detection in surveillance videos using motion vectors such as flow vector magnitudes and changes in direction except the color information. In order to evaluate the proposed algorithm, we test both USI dataset and various real world surveillance videos from YouTube.

Analysis of Saturation Flow Rate on Interrupted Flow During Rainfall (강우시 단속류 포화교통류율 변화 분석)

  • Kim, Bongseok;Roh, Chang-Gyun;Son, Bongsoo
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.90-99
    • /
    • 2015
  • The climate of Korea has clear rainy and dry season due to seasonal wind. In general, The rainy season in Korea is from early summer through to early fall. And precipitation accounted for more than half of the total annual rainfall in this period. This study is aiming to analysis of variation in saturation flow rate at signalized intersection during rainfall. The range of spatial is urban signalized intersections in Seoul and temporal is rainfall or ideal condition in daylight. Traffic data are collected through CCTV of Seoul Metropolitan Police Agency, and on-site video recordings directly. Weather condition data are collected from the Korea Meteorological Administration. In addition, the value of saturation headway and saturation flow rate, in rainfall condition, are derived through video frame analysis. As a results of analysis, decrease of saturation flow rate and increase of saturation headway during rainfall were confirmed by comparison with non-rainfall. The higher rainfall rate is, the more decreased saturation flow rate at the intersections. Rainfall rate is divided three area by the results of statistical test, and saturation flow rate decrease 7%, 17%, 21%, respectively.

Estimation of sewer deterioration by Weibull distribution function (와이블 분포함수를 이용한 하수관로 노후도 추정)

  • Kang, Byongjun;Yoo, Soonyu;Park, Kyoohong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.4
    • /
    • pp.251-258
    • /
    • 2020
  • Sewer deterioration models are needed to forecast the remaining life expectancy of sewer networks by assessing their conditions. In this study, the serious defect (or condition state 3) occurrence probability, at which sewer rehabilitation program should be implemented, was evaluated using four probability distribution functions such as normal, lognormal, exponential, and Weibull distribution. A sample of 252 km of CCTV-inspected sewer pipe data in city Z was collected in the first place. Then the effective data (284 sewer sections of 8.15 km) with reliable information were extracted and classified into 3 groups considering the sub-catchment area, sewer material, and sewer pipe size. Anderson-Darling test was conducted to select the most fitted probability distribution of sewer defect occurrence as Weibull distribution. The shape parameters (β) and scale parameters (η) of Weibull distribution were estimated from the data set of 3 classified groups, including standard errors, 95% confidence intervals, and log-likelihood values. The plot of probability density function and cumulative distribution function were obtained using the estimated parameter values, which could be used to indicate the quantitative level of risk on occurrence of CS3. It was estimated that sewer data group 1, group 2, and group 3 has CS3 occurrence probability exceeding 50% at 13th-year, 11th-year, and 16th-year after the installation, respectively. For every data groups, the time exceeding the CS3 occurrence probability of 90% was also predicted to be 27th- to 30th-year after the installation.