• Title/Summary/Keyword: CASTS

Search Result 387, Processing Time 0.025 seconds

THE STUDY ON THE PREDICTION OF THE MESIODISTAL DIAMETERS OF UNERUPTED CANINES AND PREMOLARS IN KOREAN MALE AND FEMALE (미맹출 영구 견치 및 소구치 근원심 폭경 추정에 관한 연구)

  • Hwang, Min-Sung;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.115-124
    • /
    • 2002
  • The purpose of this study was to establish regression equations and probability charts for predicting the sum of mesiodistal crown diameters of unerupted unilateral canine and premolars from the sum of mesiodistal crown diameters of four mandibular incisors in Korean male and female. The plaster casts of 162 children(75 boys and 87 girls) among the contestees in 1994-2001 Healthy Dentition Contest in Seoul were measured. Sex differences are compared and the following results were obtained: 1. Bilateral comparison of sum of widths of permanent canine and premolars showed no significant differences for either sex(p>0.05). Sum of widths of permanent canine and premolars of male were significantly larger than that of female(p<0.01). 2. Regression equations for the prediction of sum of widths of permanent canine and premolars in each sex were as follows Male ${\Sigma}Maxillary$ 345 y= 10.45+0.53x Male ${\Sigma}Mandibular$ 345 : y= 10.07+0.51x Female ${\Sigma}Maxillary$ 345 : y=12.65+0.42x Female ${\Sigma}Mandibular$ 345 : y=11.70+0.42x Male+female ${\Sigma}Maxillary$ 345 y=11.01+0.50x Male+female ${\Sigma}Mandibular$ 345 : y=9.87+0.51x

  • PDF

A STUDY ON THE SIZE AND VOLUME OF THE PALATE (구개의 크기 및 용적에 관한 연구)

  • Baik, Byeong-Ju;Kim, Mi-Ra;Kim, Jae-Gon;Yang, Yun-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.397-406
    • /
    • 2002
  • The purpose of this study was to clarify the palatal arch length, width and volume in the primary and permanent dentition. Samples were consisted of normal occlusion in the primary dentition(50 males and 50 females) and permanent dentition(43 males and 43 females). Their upper plaster casts were used and through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), cloud data, polygonization, section curve, loft surface and fit and horizontal plane were made for measuring the palatal arch length, width and volume(Surfacer 10.0, Imageware, U.S.A.). Correlation coefficients were calculated separately for males and females in each group(SPSS 10.0). The results were as follows : 1. Average distance from the fit plane to the points(tooth-tooth-palate) was greater in the permanent dentition than those of primary dentition. 2. Palatal volume was greater more than 3 times in the permanent dentition, especially it was greater in male compared to female with significance(p<0.05). 3. Palatal width of male was greater in the primary and permanent dentition but palatal length, only in the permanent dentition than that of female(P<0.05). 4. Correlation coefficients were statistically most significant between the palatal volume and size of posterior palatal width and total palatal length(r=0.401, r=0.450, r=0.678, r=0.654).

  • PDF

A Study of Prosthetic Prescriptions sent to the Laboratories for Removable Partial Denture Framework (국부의치 제작을 위한 보철의뢰 서식의 기록에 관한 임상적 연구)

  • Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.7-13
    • /
    • 1980
  • The purpose of this study was to evaluate the removable partial denture prescriptions including surveyed crowns and design of component parts sent to the laboratory technician. A total of 351 casess with prescription forms and master cast in maxillary and mandibular semi-edentulous situations collected from dental laboratory by random sampling were selected for this study. The evaluation and study observed here involved the classification of edentulous situations, status of abutment splinting, form of rest seats and guiding plane of surveyed crows, location of maxillary major connectors and tripodig marks on the master casts. Removable partial denture prescriptions contained (1) general request (upper and lower cast framework), (2) types of metal, (3) location of retainer(retention, lingual bracing, rest area, guiding plane surface), (4) location and type of major connector, (5) relief area and amount, (6) and other specific instructions. The following informations based on the classified groups such as Group I was those cases sent with no real prescriptions. They say 'make a partial.' No prescriptions, no thought beforehand, Group II was those cases sent with a minimal prescriptions. They say 'make a partial with clasps on May be some preparations, usually inadequate. Group III was those cases sent with a moderately good prescription. Adequate but could be much better. No tripoding but it tell what clasps go where. Still not good prescriptions. Group IV was good cases, tripoded with adequate prescriptions and a prescription which exactly describes what is expected from the laboratory. The analyzed results were as follows: 1. The normal form of rest seats and guiding plane of surveyed crowns in Class. I and Class. II edentulous situations on the maxillary cast were observed 31.9% and 27.89%, respectively. The abutment teeth and retainer without occlusal rests of Class. I and Class. II were showed 11.58% and 8.86%, respectively. In mandibular cases, the normal form of rest seats and guiding plane of surveyed crowns showed 27.54% and 8.82% in Class. I and Class. II situation. The abutment teeth and retainer without rest seats were showed 15.19%, respectively. 2. The splinted surveyed crowns of Class. I and Class. II maxillary edentulous situations in distal extension cases were showed 34.51% and 28.85%, but 28.52% and 10.29%, respectively. 3. The location and type of maxillary major connector delineated on the master cast were 66 cases (44.89%). 4. The results of 351 cases were classified as Group I 146(41.59%), Group II 115 (32.76%), Group III 57 (16.23%), and Group IV 33 (9.48%). 5. The delineation of abutment tooth for clasping were 176 cases (50.14%) among total of 351 cases. 6. The delineation of height of contour line were showed 45 cases (12.8%) in Group II, 14 cases (3.98%) in Group III and 33 cases (9.40%) in Group IV with total 92 cases (26.21%). 7. In surveying procedure, the delineation of tripoding marks and reference line were showed 17 cases (4.84%).

  • PDF

STUDY ON ADAPTABILITY OF RUBBER DAM CLAMPS ON PRIMARY SECOND MOLARS IN KOREAN CHILDREN (한국인 소아에서 제2유구치에 대한 러버댐 클램프의 적합도에 관한 연구)

  • Park, Mirae;Mah, Yon-Joo;Ahn, Byung Duk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.2
    • /
    • pp.98-105
    • /
    • 2013
  • The purpose of this study was to investigate the mesiodistal widths at the cervical level of primary second molars in Korean children, and to compare them with commercial rubber dam clamps commonly used in pediatric dentistry. Dental casts of 115 primary and mixed dentition children were studied. Cervical mesiodistal width (C-MD) was measured at the clinical cervical level of each primary second molar from buccal and lingual sides using a digital caliper (Absolute, Mitutoyo, Kawasaki, Japan). The data were compared with mesiodistal widths of rubber dam clamps #203/204, #10/11, and #205 (Dentech, Japan). C-MDs of primary mandibular second molars were larger than those of primary maxillary second molars, and C-MDs at buccal sides were larger than those of lingual sides. All C-MDs showed statistically significant discrepancies to corresponding widths on clamps (p < 0.05). However the amount of discrepancy was mild in maxillary teeth, while up to 1 mm of discrepancy was shown in mandibular teeth. In conclusion, C-MDs measured in this study imply a relatively fair fit of #10/#11 or #203/#204 clamps on primary maxillary second molars, while suggesting our need for a better clamp with proper size for primary mandibular second molars.

The Effect of Human Appendage Muscle Strength on Increase in Vertical Dimension from Intercuspal Position of Mandible (교두감합위로부터 출발한 수직교합고경의 단계적 증가가 사지 근력에 미치는 영향에 관한 연구)

  • Hong, Dong-Hee;Lee, Sung-Bok;Choi, Dae-Kyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.169-183
    • /
    • 2003
  • According to our recent investigation that the increase in the occlusal vertical dimension made the appendage muscle strength got higher, the occlusal appliances were made by increasing the occlusal vertical dimension "from the centric relation" position of the mandible. In this experiment, the authors tried to study the change in the appendage muscle strength due to increase in occlusal vertical dimension from intercuspal position(ICP) of mandible with the same subjects and manner as the former experiment. For this study, ten male athletes in a mean age of 23 year who were joined the former study were selected. All the subjects had a complete or almost complete set of natural teeth and reported no subjective symptoms of temporomandibular disorders. Upper and lower casts were mounted on the semi-adjustable articulator at the intercuspal position and a point was marked on the attached gingival area between the right canine and the right 1st. premolar in each upper and lower cast. From the points, the occlusal vertical dimension was increased by 2mm, 3.5mm and 5mm, and then each 10 maxillary type occlusal splint at each 3-increased position were fabricated with heat curing clear acrylic resin. Including the intercuspal position, the 3 kinds of occlusal splints were placed on the subjects individually, and then isokinetic muscle strength on 7 parts of the human appendage which are shoulder, knee, ankle, wrist, forearm, elbow and hip was measured with the CYBEX 6000 SYSTEM (Lumex, NewYork, USA). The results were as follows: The highest mean value in muscular strength was shown at the position of 2mm-increased vertical dimension. The muscle strength during internal/external rotation of shoulder and knee, plantarflexion of ankle, flexion of elbow, and flexion and extension of hip at the increased occlusal vertical dimension position were significantly higher than them at the intercuspal position (p<0.05). Only in view of the increase in the appendage muscle strength, regardless of the way of making the occlusal splints by elevating the occlusal vertical dimension from the centric relation position or intercuspal position, the occlusal splints had an effect on the increase of isokinetic muscle strength at the occlusal vertical dimension which increased within the proper range on the habitual arc of closure.

Variations in the Cusps of Mandibular Molars in Koreans (한국인 아래턱큰어금니 교두 변이에 관한 연구)

  • Yoo, Hong-Il;Kim, Ji-Hye;Kim, Sun-Hun
    • Anatomy & Biological Anthropology
    • /
    • v.27 no.3
    • /
    • pp.155-163
    • /
    • 2014
  • This study aimed to investigate the cusp size and morphological characteristics of permanent mandibular molars in Koreans with reference to the hypoconulid, and to analyze the differences and correlations between both sexes as well as between first and second mandibular molars. We obtained data from dental casts of 110 adults (78 males and 32 females). Mesiodistal and buccolingual diameters of first and second mandibular molars, the area of five cusps (protoconid, metaconid, hypoconid, entoconid, and hypoconulid), as well as the total cusp area and occlusal table area were measured. Paired t-test was performed to analyze the morphological differences between first and second mandibular molars and the sex differences between both sexes using SPSS program. Crown diameters and cusp areas of mandibular first molars were larger than those of mandibular second molars in both sexes. The hypoconulid was the most variable in size and morphological pattern among the five cusps, and the first molars showed a higher incidence of hypoconulid than the second molars. Except for the entoconid area of the first molar (p=0.06) and the hypoconulid area of the second molar (p=0.24), all other mean values were larger in males than in females, demonstrating a significant sexual dimorphism. These data suggest that the teeth which develop late in ontogeny tend to be smaller in size and more variable in morphological characteristics.

Turbine Blading Performance Evaluation Using Geometry Scanning and Flowfield Prediction Tools

  • Zachos, Pavlos K.;Pappa, Maria;Kalfas, Anestis I.;Mansour, Gabriel;Tsiafis, Ioannis;Pilidis, Pericles;Ohyama, Hiroharu;Watanabe, Eiichiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.89-96
    • /
    • 2008
  • This paper investigates the effect of blade deformation, caused by manufacturing inaccuracies, on the performance of a 2-stage axial steam turbine. A high fidelity 3D coordinate Measurement Machine has been employed to obtain the exact geometrical model of the blades. A Streamline Curvature solver was used to predict the overall performance of the turbine. During the manufacturing process of the casts and of the blades themselves, several types of errors can occur which lead to a different geometry from that envisaged by the designer. The main objective of this study is to investigate the effect of those errors on the performance of a 2-stage experimental axial steam turbine. A high fidelity measurement of the actual geometry of both stator and rotor blades has been carried out, using a 3D Coordinate Measurement Machine. The cross sections of the blades obtained by the measurement were compared with those produced by the design process to evaluate the change in blade inlet/exit angles. In addition, the geometrical deviations from the initial design have been subjected to a statistical study in order to locate the nature of the error. The actual(measured) model has been used as input into a Streamline Curvature solver to evaluate its performance. Finally, a comparison with the performance plots of the original geometry has been carried out. A measurable change of efficiency as well as in the total power delivered by the turbine was found. This suggests that the accumulated error caused during the manufacturing procedure plays a significant role in the overall performance of the machine by making it less efficient by more than 1%. Reverse engineering techniques are proposed to predict and alleviate these errors leading thereby to a final design of each stage with improved performance.

  • PDF

A Study on Over-Valuation of Agreed Value in Marine Insurance -Focussed on Comparison of MIA, Japan and Korean Commercial Code- (해상보험에 있어서 협정보험가액의 과대평가에 관한 연구 -영국, 일본, 한국상법의 비교를 중심으로-)

  • Choi, Young-Bong;Park, Won-Hyung
    • International Area Studies Review
    • /
    • v.12 no.2
    • /
    • pp.277-295
    • /
    • 2008
  • Insurable value agreed by the parties shall be presumed specified at the time of the accident. It is nevertheless provided that where agreed value considerably exceeds certain amount evaluated at the time of insured accident, the amount shall be insurable value. It casts doubt on what constitutes such an excess in valuation in marine insurance. Because of the relatively short periods and less volatile economies, maritime insurance, with the statutory insurance value, has deemed insurable value conclusive. In other ways, the provision of default rule substitutes the amount evaluated at the time of insured accident for statutory insurance value. However, over-valuation of agreed value determined by the comparison of statutory insurance value leads to non sequitur in valued policy. Maritime insurance, in the case of over-valuation of agreed value, construes certain amount evaluated at the time of insured accident as insurable value. Accordingly, beyond the application of statutory insurance value, the amount should be considered for over-valuation of agreed value.

Modern transformation phrase of (<공무도하가>의 현대적 변용 양상)

  • Ha, Gyoung Sook
    • (The)Study of the Eastern Classic
    • /
    • no.43
    • /
    • pp.93-123
    • /
    • 2011
  • is a work of art that was composed through fluid and laminating by being passed down orally for a long time like other ancient songs. As well as, it is given a history of literature's value in the point that it is a Korea's first poetry work, it is considered it casts a long shadow to establishing traditionality of our country's poetry. Even today, has been transformed and recreated into a variety of genres because its literary subject carry the universal emotions and win the sympathy. This manuscript examines modern poetry, modern novel and modern songs that consist of changed ancient song and looks modern writers' perspective about through characteristic that each of works has and then aims checking special situation and meaning that is implicit and recognizing the value of the original. As the has been recreated as modern poetry, it shows the current chaotic situation specifically by embodying it and actively seeks expressing human character, agony and longing, etc, by excluding factor of the original mythical interpretation. Also it rouses situation of reality as detained and repressed. , recreated as modern novel, expands narrative structure and shows portrait of various characters and speaks diverse human condition about reality and suggests plan for dealing with that. Basic emotions of the original is strongly passed to modern popular song . It makes us know that universal emotions which human has across generations can touch people transcending time and space and it is a fresh discovery and possibility that reaffirms the emotion of our people. Ancient song has been studied with emphasis on resignation and grief by focusing on the subject, simply parting and death. But recently, through transformation between a wide range of genres. it carries the spirit of the times that author toward, showing realistic and specific situations. Flexibility of ancient song is expected to continue its vitality transcending generations. Ancient song is assured that it can lead various aspects through active groping in era of change with a various possibility, that the original has, through communication between genres.

Comparison of Reproducibility of Linear Measurements on Digital Models among Intraoral Scanners, Desktop Scanners, and Cone-beam Computed Tomography

  • Jo, Deuk-Won;Kim, Mijoo;Kim, Reuben H.;Yi, Yang-Jin;Lee, Nam-Ki;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Purpose: Intraoral scanners, desktop scanners, and cone-beam computed tomography (CBCT) are being used in a complementary way for diagnosis and treatment planning. Limited patient-based results are available about dimensional reproducibility among different three-dimensional imaging systems. This study aimed to evaluate dimensional reproducibility among patient-derived digital models created from an intraoral scanner, desktop scanner, and two CBCT systems. Materials and Methods: Twenty-nine arches from sixteen patients who were candidates for implant treatments were enrolled. Different types of CBCT systems (KCT and VCT) were used before and after the surgery. Polyvinylsiloxane impressions were taken on the enrolled arches after the healing period. Gypsum casts were fabricated and scanned with an intraoral scanner (CIOS) and desktop scanner (MDS). Four test groups of digital models, each from CIOS, MDS, KCT, and VCT, respectively, were compared to the reference gypsum cast group. For comparison of linear measurements, intercanine and intermolar widths and left and right canine to molar lengths were measured on individual gypsum cast and digital models. All measurements were triplicated, and the averages were used for statistics. Bland-Altman plots were drawn to assess the degree of agreement between each test group with the reference gypsum cast group. A linear mixed model was used to analyze the fixed effect of the test groups compared to the reference group (α=0.05). Result: The Bland-Altman plots showed that the bias of each test group was -0.07 mm for CIOS, -0.07 mm for MDS, -0.21 mm for VCT, and -0.25 mm for KCT. The linear mixed model did not show significant differences between the test and reference groups (P>0.05). Conclusion: The linear distances measured on the digital models created from CIOS, MDS, and two CBCT systems showed slightly larger than the references but clinically acceptable reproducibility for diagnosis and treatment planning.