• 제목/요약/키워드: CASTS

검색결과 387건 처리시간 0.021초

Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study

  • Jo, Si-Hoon;Kim, Kyoung-Il;Seo, Jae-Min;Song, Kwang-Yeob;Park, Ju-Mi;Ahn, Seung-Geun
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.128-133
    • /
    • 2010
  • PURPOSE. The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS. The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with $10^{\circ}$ of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (${\alpha}$= .05), and the statistical significance was set at P < .05. RESULTS. The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION. Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and $10^{\circ}$ mesial angulated groups.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

노.사.정 사회적 합의가 장애인 복지정책에 주는 함의 (Social Consensus among Two sides of Industry and the Government and its Implication for Disability Policy)

  • 이성규
    • 한국사회복지학
    • /
    • 제36권
    • /
    • pp.259-283
    • /
    • 1998
  • 98. 2. 6 노사정 사회적 합의를 IMF 자금지원으로 인한 국가적 경제위기가 만들어낸 계기적 산물로 보아서는 합의구조의 향후 방향성과 견고성을 평가하는데 한계를 가질 수 밖에 없다. 따라서 본 연구는 '98.2.6 합의를 도출시킬 수 있었던 한국의 사회적 합의구조의 뿌리를 분석하여 역사적 연원을 밝혀 내었다. 이 과정에는 사회적 합의정신에 바탕을 두고 형성된 정치 사회적인 모델인 사민주의 또는 조합주의의 적용가능성을 분석하는 한편, 도니슨(D. Donnison)의 복지국가적 사회적합의 모델의 조건들을 한국의 역사적 관점에 입각하여 분석하였다. 위에서 도출된 사회적 합의의 역사성을 장애인, 사업주, 정부를 변수로 하는 장애인 고용정책에 적용하여 봄으로써, 사회정책과정에서의 사회적 합의모형의 설명력과 예측력을 분석하여 보았다. 분석 결과 장애인 고용 문제 역시 사회 문제의 한 부분이므로 진공 속에서 해결하기는 불가능하며 사회적 합의구조와 비슷한 구조인 장 사 정(障 事 政) 합의구조 속에서 좀더 효과적인 정책수행이 가능함을 추론할 수 있었다. 이에따라 IMF자금지원 이후에 새롭게 발생된 장애인 고용 정책상의 문제를 진단 처방해보는 것도 연구의 실천성을 평가해볼 수 있는 소득이었다.

  • PDF

의료이용(醫療利用)에 영향(影響)을 미치는 요인(要因)에 관(關)한 분석(分析) (On Determinants of Physician Utilization -A causal analysis-)

  • 배상수
    • Journal of Preventive Medicine and Public Health
    • /
    • 제18권1호
    • /
    • pp.13-24
    • /
    • 1985
  • This study seeks to provide a framework for understanding differential access to medical care. The framework is provided by Anderson Model, a model of health services utilization which suggests a sequence of predisposing, enabling, illness-morbidity characteristics that determine the number of times people will visit a physician. The framework in this study is composed of two models, one is for Adults and the other is for Non-Adults. Models are operationalized using stepwise multiple regression analysis and path analysis. The data come from a national health survey conducted in 1983. The findings of the analysis can be summarized as follows : First, the causal models used in this study are able to explain only a small amount of the variance in medical care utilization(Adjusted $R^2$ is .144 in the Model for Adults and .243 in that for Non-Adults). This finding suggests that we reconsider the utility of such existing model using the predisposing, enabling, and illness-morbidity characteristics in light of their poor correspondence with these data. Second, while small amount of the valiance in medical care utilization is explained, most of the explained variance is due to the illness-morbidity characteristics. The path coefficients of study variables except illness-morbidity variables show these characteristics to be substantially unrelated to medical care utilization, and the indirect effects of the predisposing and edabling characteristics on medical care utilization are also negligible. This casts doubt on the importance of the predisposing and enabling characteristics in explaining medical care utilization. Third, among the predisposing and enabling characteristics, Medical Security variable is the only one having significant direct effect on medical care utilization in both models for Adults and for Non-Adults. Fourth, the amount of the variance explained in the Model for Non-Adults is more than in the Model for Adults. This suggests that medical care utilization of adults is more influenced by behavioral factors than that of children.

  • PDF

음선이론을 이용한 백령도 부근해역 다중빔 수심측량 자료의 수직.수평 오차 분석 (A precision analysis of Baengnyeongdo Multi-beam echosounder data using acoustic ray theory)

  • 유승기;주종민;최지웅;김영배;정현;김서철;박성규
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2009년도 학술대회 초록집
    • /
    • pp.167-173
    • /
    • 2009
  • 2009년 국립해양조사원은 백령도 부근 해역에 대해 바다로 1호에 장착된 Simrad EM3000 다중빔 음향측심기를 이용한 수심측량조사를 실시하였으며 정확한 음속보정을 위해 1일 $7{\sim}10$회 이상의 음속을 관측하였다. 백령도 주변해역은 계절에 따라 여러 질 수괴(쿠로시오 난류, 황해 연안수 등)가 복잡하게 분포하여 여러 형태의 수온 전선이 형성되어 수층 음속 깊이가 최대 10m/s 이상의 차이를 나타냈다. 또한 난수괴 유입으로 인해 수온약층의 깊이가 지역별로 다르게 분포 하였다. 이러한 음속의 국지적 변화는 다중빔을 이용한 수심측량 자료의 정확도를 저하시키는 요인으로 작용한다. 따라서 다중빔을 이용한 수심측량 자료의 정확도를 저하시키는 요인으로 작용한다. 따라서 백령도 주변해역 수심측량 자료의 수평 수직 변화를 음선추적 이론을 이용하여 확인하였다.

  • PDF

Effects of Vermicompost on Growth of Fall-Cropping Potato in Volcanic Ash Soil

  • Kang Bong Kyoon
    • 한국작물학회지
    • /
    • 제49권4호
    • /
    • pp.305-308
    • /
    • 2004
  • Recently, with increasing concern for sustainable agriculture and safe agricultural products, organic farming has become widely adapted as an alternative to conventional farming. This study was conducted to investigate the effects of earthworm casts (EWC) with $100\%$ organic compost on the growth and yield characteristics of fall-cropping potato (Solanum tuberosum L. cv. Dejima) in Jeju. The treatments consisted of seven plots: 2-, 4-, 6-, 8-, and 10-ton $ha^{-1}$ EWC-treated plots, 1.2-ton $ha^{-1}$ complex fertilizer $(N-P_2O_5-K_2O,\;10-10-14)-for-potato$ (CEP)-treated plot as conventional practices, and a control plot. The plant heights were greater in the plots where EWC and CFP were applied than in the control plot. Tuber diameter, number of stems per plant, and chlorophyll level tended to increase in the plots where 8-10 tons $ha^{-1}$ of EWC were applied. The application of CFP and EWC showed an increment in the average tuber weight per plant, but there was minimal significant difference. The application of 8-10 tons $ha^{-1}$ of EWC resulted in an increase in the total tuber yield (21.61-21.87 tons $ha^{-1}$) as compared to the other plots. The highest yield of market able tubers was $69.8\%$ of the total yield from the 10-ton $ha^{-1}$ EWC-treated plot. Consequently, with regard to the growth and yield characteristics of fall-cropping potato, the effects of EWC application were more favorable than the effects of the application of a chemical fertilizer.

黃海水 와 循環에 관한 考察 (A Note on Water Masses and General Circulation in the Yellow Sea (Hwanghae))

  • 이흥재
    • 한국해양학회지
    • /
    • 제19권2호
    • /
    • pp.187-194
    • /
    • 1984
  • 黃海에서 水塊와 循環에 대해 간략히 檢討, 討議하였다. 水塊는 黃海冷水, 黃海溫流水, 沿岸水, 陽子江 稀釋수 네가지로 分類된다. 黃海冷水는 長技 海洋觀測資料와 최근 CTD로 資料부터 32.0~33.0%의 鹽分, 1$0^{\circ}C$이하의 水溫을 갖고 있는 것으로 定義할 수 있다. 海水循環은 南部海域에서 年中 反時計方向의 海水循環이 存在한다. 겨울철에는 中國沿岸을 따라 南向하는 沿岸流流가 北風, 北西風으로 인해 强하게 나타나며 濟州道 西部 海域에 강한 水溫.鹽分前線이 잘 보여주듯 黃海暖流는 弱해진다. 반면에 여름철에는 陽子江 釋수가 濟州道 쪽을 향해 北東쪽으로 擴張하며 中國 沿岸流가 상당히 減少하게 된다. 지금 까지 여름철 東南黃海에서 北向流를 黃海暖流로 分類하였으나 류의 延長이 아니라 沿岸水와 黃海冷水사이 境界面을 따라 形成되는 密度流로 보는 것이 더욱 妥當하다.

  • PDF

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

Ridge preservation using basic fibroblast growth factor-2 and collagenated biphasic calcium phosphate in beagle dogs

  • Sohn, Byungjin;Hwang, Minkyoon;Kim, Sungtae;Kim, Hyeong-Il;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • 제47권6호
    • /
    • pp.381-387
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate volumetric and histologic changes in edentulous alveolar ridge areas after ridge preservation using basic fibroblast growth factor-2 (bFGF-2) in combination with collagenated biphasic calcium phosphate (BCP). Methods: The experiments were performed in 6 adult male beagle dogs. The following 3 groups were created: 1) ridge preservation with bFGF-2 and collagenated BCP (experimental group), 2) ridge preservation with collagenated BCP (positive control group), and 3) a negative control group in which no ridge preservation procedure was performed. Volumetric change analysis was performed using an optical scanner and casts. Histological observations were made using light microscopy. Results: After the initial swelling subsided, the magnitude of the volumetric change in the experimental group and positive control group was smaller than in the negative control group. In the experimental group, a distinct trend was observed for the resorption of residual bone and collagen fibers at 4 weeks and for more mature bone and faster healing at 12 weeks. Conclusions: Based on the findings of the present study, bFGF-2 may be considered for use as a therapeutic molecule in ridge preservation procedures.