• Title/Summary/Keyword: CAST

Search Result 3,551, Processing Time 0.026 seconds

A Nonlinear Structural Analysis for a Composite Structure Composed of Spent Nuclear Fuel Disposal Canister and Bentonite Buffer: Symmetric Rock Movement (고준위폐기물 처분용기와 벤토나이트 버퍼로 이루어진 복합구조물에 대한 비선형 구조해석: 대칭 암반 전단력)

  • 권영주;최석호;최종원
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.4
    • /
    • pp.369-376
    • /
    • 2003
  • In this paper, a nonlinear structural analysis for the composite structure composed of the spent nuclear fuel disposal canister and the 50㎝ thick bentonite buffer is carried out to predict the collapse of the canister while the horizontal symmetric sudden rock movement of 10㎝ is applied on the composite structure. This sudden rock movement is anticipated by the earthquake etc. at a deep underground. Elastoplastic material model is adopted. Drucket-Prager yield criterion is used for the material yield prediction of the bentonite buffer and von-Mises yield criterion is used for the material yield prediction of the canister(cast iron, copper). Analysis results show that even though very large deformations occur beyond the yield point in the bentonite buffet, the canister structure still endures elastic small strains and stresses below the yield strength. Hence, the 50㎝ thick bentonite buffet can protect the canister safely against the 10㎝ sudden rock movement by earthquake etc.. Analysis results also show that bending deformations occur in the canister structure due to the shear deformation of the bentonite buffer.

Characteristic of Fish Community in the Stream Flowing into the Han River in Seoul, Korea (서울시 한강으로 유입되는 하천의 어류 군집 특성)

  • Byeon, Hwa-Keun
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.3
    • /
    • pp.261-273
    • /
    • 2018
  • This study investigated the characteristics of fish communities in the streams flowing into the Han river in Seoul in May 2016 through April 2017. The investigated streams were Ui stream, Danghyeon stream, Cheonggye stream, Yangjae stream, Mokgam stream, Dorim stream, and Hongje stream, which were restored to their natural form. We collected 41 species of 10 families using skimming nets and cast nets from 21 points during the investigation period. There were 7 Korean endemic species, or 17.1% in collected species, such as Acheilognathus yamatsutae, Acheilognathus gracilis, Scrcocheilichthys nigripinnis morii, Squalidus japonicus coreanus, Zacco koreanus, Coreoperca herzi, and Odontobutis interruta. There were 5 (12.2%) exotic species: Cyprinus carpio (fancy type), Carassius auratus (goldfish), Carassius cuvieri, Lepomis macrochirus, and Micropterus salmoides. The dominant species were Zacco platypus, Carassius auratus, Acheilognathus lanceolatus, Acheilognathus gracilis, and Oryzias sinensis. The Yangjae stream showed more stable fish community than other streams as it showed higher species diversity, and evenness and richness indices. Regarding the fish tolerance guild according to water quality, there were 3 (7.3%) sensitive species, 16 (39.0%) intermediate species, and 22 (56.7%) tolerant species. Twelve (29.3%) were insectivore species, 23 (56.1%) were omnivore species, and 6 (14.6%) were carnivore species, indicating the dominating presence of omnivore fish species.

Reliability and Validity of the Korean Version of the Short Michigan Alcoholism Screening Test for Fathers and Mothers (부모의 음주문제를 선별하는 도구의 신뢰도 및 타당도 분석 -한국어판 Short Michigan Alcoholism Screening Test for Fathers and Mothers의 평가-)

  • Kim, Yong-Seok
    • Korean Journal of Social Welfare
    • /
    • v.56 no.3
    • /
    • pp.37-59
    • /
    • 2004
  • Short Michigan Alcoholism Screening Test for Fathers(F-SMAST) and Mothers(M-SMAST) is to measure the presence of an alcohol use disorder in one's father and/or mother. The purpose of this study is to evaluate the Korean version of the F-SMAST and M-SMAST. A total of 241 college students, who resided in Seoul and two other cities, participated in this study. The internal consistency of the Korean version of the F-SMAST and M-SMAST was assessed using alpha coefficient. The alpha coefficient of both the F-SMAST and the M-SMAST was 0.82. Standard Errors of Measurement(SEM) were also computed. SEMs of the F-SMAST and the M-SMAST were quite low. With a cut-off score of 3, the F-SMAST correctly identified 91 percent of respondents who were presumed to be children of alcoholics and correctly identified 81 percent of respondents who were presumed not to be children of alcoholics. Sensitivity and specificity of the M-SMAST with a cut-off score of 1 are 0.33 and 0.81, respectively. Several variables were examined in relation to the F-SMAST and the M-SMAST to examine convergent and discriminant validity. It was found that the F-SMAST and the M-SMAST were significantly correlated with most of convergent variables(average amount of drinking per day, AUDIT, distress) and had not statistically significant relationships with discriminant variables(demographic variables). This study suggests that the Korean version of the F-SMAST and the M-SMAST be repeatedly assessed across different sample in order to confirm the findings of this study.

  • PDF

Clinical features of the gingiva according to maxillary anterior teeth form in adult (성인 상악 전치 형태에 따른 치은의 임상적 소견)

  • An, Chi-Hyun;Heo, Soo-Rye;Cho, Ik-Hyun;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.359-369
    • /
    • 2005
  • It has been suggested that morphologic characteristics of the periodontium are partly related to the shape and form of the teeth. Furthermore, the severity of symptoms of periodontal disease have been proposed to differ among these various morphologic entities or "biotypes". The purpose of the present study was to examine the relationship between the form of the crowns in the maxillary anterior tooth segment and (1) a group of morphological characteristics and (2) the thickness of the gingiva. The thickness of gingiva was measured by ultrasonic device(SDM). 100 subjects devoid of symptoms of destructive periodontal disease were examined regarding, e.g., probing depth, gingival recession, width of keratinized gingiva, thickness of the keratinized gingiva. From maxillary study cast, the width(at the apical third-CW) and the length(CL) of the crowns of the 6 anterior teeth were determined. A CW/CL-ratio was calculated for each tooth and averaged for each tooth region. The individual mean CW/CL-ratio values for the central incisors were ranked. The 10 subjects ranked highest and the 10 ranked lowest were selected as having either a long-narrow(group N) or a short-wide(group W) form of the crown of the tooth. The data for each of the examined parameters were averaged for each tooth region in each subject and mean values for subjects in groups W and N were compared using the Student t-test. Stepwise multiple regression analysis, including data from the whole sample, was performed for each tooth region with the thickness of the free gingiva as the dependent variable. The results from the analyses demonstrated that individuals with a long-narrow form of the central incisors displayed, compared to individuals with a short-wide crown, form (l) a narrow zone of keratinized gingiva, (2) a pronounced "scalloped" contour of the gingival margin. There was no significant difference between groups N and W with respect to the thickness of the keratinized gingiva. The CW/CL-ratio data revealed that a certain form of the crowns in the central incisors was accompanied by a similar form in the lateral incisors and canine tooth region. The regression analyses demonstrated that the thickness of the keratinized gingiva in central, lateral incisors and canines was significantly related to the width of the keratinized gingiva.

AN ANALYSIS OF FAILURE MODE OF TEETH RESTORED WITH FIBER-REINFORCED POSTS UNDER THE CONDITION OF BONY RESORPTION (치주지지가 감소된 상태에서 섬유강화형 포스트로 수복한 치아의 실패양상 분석)

  • Lee Byung-Woo;Yi Yang-Jin;Cho Lee-Ra;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.232-242
    • /
    • 2003
  • Statement of problem : Fiber-reinforced posts have lower modulus of elasticity than titanium post or cast post-core. With this similar elasticity to that of dentin, fiber-reinforced posts have been known to have a tendency to reduce the risk of root fracture. However, there were few studies on the teeth restored with fiber-reinforced posts under the condition of reduced periodontal support. Purpose : The purpose of this study was to evaluate the fracture strength and failure mode of endodontically treated teeth restored with fiber-reinforced posts and titanium posts under the condition of reduced periodontal support. Material and method : Extracted human maxillary incisor roots were divided into 3 groups (group 1 carbon fiber post, group 2 : glass fiber post, and group 3 : titanium alloy post). After coronectomy and endodontic treatment, teeth were restored with each post systems and resin core according to the manufacturer's recommendation. Then, teeth with simulated periodontal ligament were embedded in the acrylic resin blocks at the level of 4 mm below the cemento-enamel junction. Each specimen was exposed to $10^5$ load cycles with average 30 N force in $36.5^{\circ}C$ water using a computer-controlled chewing simulator. Loads were applied at $45^{\circ}$ angle to the long axis of the teeth. After cyclic loading, teeth were subjected a compressive load until failure at a crosshead speed of 0.5 mm/min. Fracture strength (N) and failure mode were examined. The fracture strength was analyzed with one-way ANOVA and the Scheffe adjustment at the 95% significance level. Results and conclusion : The results were as follows. 1. There was no statistically significant difference in the mean fracture strength among the groups (P<.05). 2. Carbon fiber post and glass fiber post group showed less root fracture tendency than control group. 3. All specimens with root fractures showed fracture lines above the level of acrylic resin block, except for only one specimen in group 3.

COMPARISON OF MECHANICAL PROPERTIES OF VARIOUS POST AND CORE MATERIALS

  • Ahn Seung-Geun;Sorensen John A.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.288-299
    • /
    • 2003
  • Statement of problem: Many kinds of post and core systems are in the market, but there are no clear selection criteria for them. Purpose: The purpose of this study was to compare the flexural strength and modulus of elasticity of core materials, and measure the bending strength of post systems made of a variety of materials. Material and Methods: The flexural strength and elastic modulus of thirteen kinds core buildup materials were measured on beams of specimens of $2.0{\times}2.0{\times}24{\pm}0.1mm$. Ten specimens per group were fabricated and loaded on an lnstron testing machine at a crosshead speed of 0.25mm/min. A test span of 20 mm was used. The failure loads were recorded and flexural strength calculated with the measured dimensions. The elastic modulus was calculated from the slopes of the linear portions of the stress-stram graphs. Also nine kinds commercially available prefabricated posts made of various materials with similar nominal diameters, approximately 1.25mm, were loaded in a three-point bend test until plastic deformation or failure occurred. Ten posts per group were tested and the obtained data were anaylzed with analysis of variance and compared with the Tukey multiple comparison tests. Results: Clearfil Photo Core and Luxacore had flexural strengths approaching amalgam, but its modulus of elasticity was only about 15% of that of amalgam. The strengths of the glass ionomer and resin modified glass ionomer were very low. The heat pressed glass ceramic core had a high elastic modulus but a relatively low flexural strength approximating that of the lower strength composite resin core materials. The stainless steel, zirconia and carbon fiber post exhibited high bending strengths. The glass fiber posts displayed strengths that were approximately half of the higher strength posts. Conclusion: When moderate amounts of coronal tooth structure are to be replaced by a post and core on an anterior tooth, a prefabricated post and high strength, high elastic modulus core may be suitable. CLINICAL IMPLICATIONS In this study several newly introduced post and core systems demonstrated satisfactory physical properties. However when the higher stress situation exists with only a minimal ferrule extension remaining a cast post and core or zirconia post and pressed core are desirable.

Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy

  • Minesaki, Yoshito;Murahara, Sadaaki;Kajihara, Yutaro;Takenouchi, Yoshihisa;Tanaka, Takuo;Suzuki, Shiro;Minami, Hiroyuki
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS. Disk-shaped specimens ($2.5{\times}10.0mm$) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using $110{\mu}m$ alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (${\alpha}=.05$). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS. There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION. Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys.

The Effect of Human Appendage Muscle Strength on Increase in Vertical Dimension from Intercuspal Position of Mandible (교두감합위로부터 출발한 수직교합고경의 단계적 증가가 사지 근력에 미치는 영향에 관한 연구)

  • Hong, Dong-Hee;Lee, Sung-Bok;Choi, Dae-Kyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.169-183
    • /
    • 2003
  • According to our recent investigation that the increase in the occlusal vertical dimension made the appendage muscle strength got higher, the occlusal appliances were made by increasing the occlusal vertical dimension "from the centric relation" position of the mandible. In this experiment, the authors tried to study the change in the appendage muscle strength due to increase in occlusal vertical dimension from intercuspal position(ICP) of mandible with the same subjects and manner as the former experiment. For this study, ten male athletes in a mean age of 23 year who were joined the former study were selected. All the subjects had a complete or almost complete set of natural teeth and reported no subjective symptoms of temporomandibular disorders. Upper and lower casts were mounted on the semi-adjustable articulator at the intercuspal position and a point was marked on the attached gingival area between the right canine and the right 1st. premolar in each upper and lower cast. From the points, the occlusal vertical dimension was increased by 2mm, 3.5mm and 5mm, and then each 10 maxillary type occlusal splint at each 3-increased position were fabricated with heat curing clear acrylic resin. Including the intercuspal position, the 3 kinds of occlusal splints were placed on the subjects individually, and then isokinetic muscle strength on 7 parts of the human appendage which are shoulder, knee, ankle, wrist, forearm, elbow and hip was measured with the CYBEX 6000 SYSTEM (Lumex, NewYork, USA). The results were as follows: The highest mean value in muscular strength was shown at the position of 2mm-increased vertical dimension. The muscle strength during internal/external rotation of shoulder and knee, plantarflexion of ankle, flexion of elbow, and flexion and extension of hip at the increased occlusal vertical dimension position were significantly higher than them at the intercuspal position (p<0.05). Only in view of the increase in the appendage muscle strength, regardless of the way of making the occlusal splints by elevating the occlusal vertical dimension from the centric relation position or intercuspal position, the occlusal splints had an effect on the increase of isokinetic muscle strength at the occlusal vertical dimension which increased within the proper range on the habitual arc of closure.

Full Mouth Rehabilitation with a Overlay Denture (피개의치를 이용한 지적장애인의 완전구강회복)

  • Ko, Kyung-Ho;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.385-395
    • /
    • 2012
  • This clinical report presents the case using overlay dentures to treat a patient with cleft lip and palate and malocclusion. This patient requires vigorous treatment such as orthodontic treatment and combined orthodontic/oral surgery procedures. Overlay denture can be used as an alternative treatment option. Intraoral and radiographic examinations were done. The vertical dimension of occlusion was evaluated for proper prosthetic procedures and the surveying in the diagnostic cast was done. Considering the tissue and teeth undercut, the alterations of teeth shape were done. Final preparation and impression was performed. After the evaluation of vertical dimension and occlusion with wax-denture, the dentures were polymerized. Clinical remounting and occlusal adjustment were done on the articulator. Overlay dentures were delivered and the patient was recalled for relining. The overlay dentures satisfied patient's esthetic and functional requirements and provided a stable occlusion. Overlay dentures in this case were a reversible and relatively inexpensive treatment for this patient, however the potential possibilities of caries and periodontal disease as a result of poor oral hygiene should be prevented with periodic recall.

Performance Evaluation of Long Span Bridge Columns Strengthened with High-Performance Glass Fiber (고성능 유리섬유로 보강된 해상장대교량 교각의 보강성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok;Lee, Jae-Uk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.1
    • /
    • pp.125-133
    • /
    • 2010
  • Researches and studies which have been conducted so far on external confinement of long span concrete columns have mainly concentrated on concentric loading. But, long span bridge concrete columns over the sea are mainly subjected to concentrated axial load, and at the same time lange amount of moment by eccentric load. This paper experimentally investigates the performance of externally confined high-strength concrete columns subjected to loading mechanism and evaluates the effectiveness of two confinement materials carbon fibre and high performance glass fibre. Twelve short columns with the same dimensions were cast and tested Six columns were reinforced with hoop bars, the remaining six columns were reinforced with spiral bars and wrapped with three layers of carbon failure and high performance glass FRP sheets. Test variables considered were the shape of internal reinforcement and strengthening materials according to loading location. The experimental results showed that eccentric load could obviously lower down the maximum failure load of FRP-confined concrete columns, compared with the columns under concentric load. And compared with the carbon FRP-confined reinforced concrete columns, high performance glass FRP-confined columns displayed a higher load capacity and ductility, when tested both concentrically and eccentrically.