• Title/Summary/Keyword: CAM work

Search Result 166, Processing Time 0.024 seconds

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

Observation of Castability of Dental DLP 3D Printer Materials (치과용 DLP 3D Printer 가공체의 주조성 관찰)

  • Song, Joon-boo;Park, Yu-jin;Choi, Sung-min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.255-262
    • /
    • 2019
  • Purpose: Recently, the production technology of dental prosthesis using 3D Printer workpeices has been developed. However, the lack of information on the work processes and casting techniques of materials for 3D printing casting is expected to require research. Therefore, in this study, we intend to cast a Dental DLP 3D Printer workpiece, which is being commercialized, to identify its appearance and internal clearance, and to observe its castability. Methods: Castability of the 3D Printer workpiece was evaluated. The specimen is prepared in a cylindrical shape and in a 1 mm thick coping shape. The control specimen is made of wax and the experimental specimen is made of resin using two types of 3D printers. After casting, the appearance of the casting body was observed and the internal clearance of the coping was measured. Results: RP1 and RP2, cylindrical specimens, were partially cast or fin. When coping-type specimens were measured before casting, the internal clearance of PE2 was more accurate than that of PC and PE1. When coping-type specimens were measured after casting, CE1 was the most accurate in occlusal clearance and CE2n was the most accurate in axial clearance. Conclusion: 1. Exterior observations of the casting body indicated casting defects and fins. 2. Internal clearance observations show that the occlusal clearance of the castings is larger after casting, and the axial clearance of the castings is smaller after casting. 3. It is judged that the RP2 specimen is more likely to be applied for casting than the RP1 specimen.

Comparison of the Internal Fitness of Prostheses Fabricated with Non-Contact Extra-Oral Scanner and Intra-Oral Video Scanner (비접촉식 구강외 스캐너와 비디오방식 구강내 스캐너를 이용하여 제작된 보철물의 내면정확도 비교)

  • Park, Jin-Young;Kim, Ji-Hwan;Jeong, Il-Do;Lee, Gwang-Young;Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.263-269
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.

Evaluation on Pharmacological Activities of 2,4-Dihydroxybenzaldehyde

  • Jung, Hyun-Joo;Song, Yun-Seon;Lim, Chang-Jin;Park, Eun-Hee
    • Biomolecules & Therapeutics
    • /
    • v.17 no.3
    • /
    • pp.263-269
    • /
    • 2009
  • 4-Hydroxybenzaldehyde, a phenolic compound found in a variety of natural sources, was previously shown to contain anti-inflammatory and related anti-angiogenic and anti-nociceptive activities. The present work was designed to assess some pharmacological activities of 2,4-dihydroxybenzaldehyde (DHD), an analogue of 4-hydroxybenzaldehyde. DHD exhibited a significant inhibition in the chick chorioallantoic membrane (CAM) angiogenesis, and its $IC_{50}$ value was $2.4\;{\mu}g/egg$. DHD also contained in vivo anti-inflammatory activity using acetic acid-induced permeability and carrageenan-induced air pouch models in mice. In the air pouch model, DHD showed significant suppression in exudate volume, number of polymorphonuclear leukocytes and nitrite content. DHD showed an anti-nociceptive activity in the acetic acid-induced writhing test in mice. It also suppressed enhanced production of nitric oxide (NO) and elevated expression of inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2) in lipopolysaccharide (LPS)-stimulated RAW264.7 macrophage cells. It was able to slightly decrease the level of reactive oxygen species in the stimulated macrophages. DHD at the used concentrations couldn't modulate the viabilities of RAW264.7 cells. Taken together, like 4-hydroxybenzaldehyde, DHD contains anti-angiogenic, anti-inflammatory and anti-nociceptive activities.

A Behavior Ana1ysis of Clayey Foundation Improved with Pack Drain (Pack-Drain으로 개량된 점토지반의 거동해석)

  • 오재화;남기현;이문수;허재은;김영남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.1
    • /
    • pp.116-127
    • /
    • 1996
  • This paper dealt with FEM analysis of foundation improved with pack drain. The theory on pack drain was scrutinized and observed values in the field were compared with numerical results. Work site of Kwangyang container pier was selected as a ease study in which measurement of settlement and pore water pressure was accurately carried out. Biot's consolidation equation was selected as governing One, coupled with modified Camclay model as constitutive one. Christian and Boehmer's numerical technique was adopted. Behavior of foundation with pack drain is not simple but very complicated. Discontinuity resulted from rigidity difference between adjacent materials, smear effect and complicated boundary conditions should be considered in the behavior analysis of foundation behavior. The results of numerical analysis were influenced by smear zone. In relevant to this effect, finite element analysis was carried out using the reduced horizontal coefficient of permeability in the smear zone; The numerical results were compared with observed values in surface settlement. including pore water pressure. However only lateral di5plaoement by numerical ana1Ysis was shown since its measurement was not performed in the field. The predication of settlement to be developed later can be effectively employed for the obtimization of construction. The predication of residual settlement using the data measured in the field was made by Hoshino, Asaoka and hyperbolic method. Among them, the hyperbolic method proved best one. Settlements accorded well between numsrical and observed values while pore pressure showed a slight difference. Lateral displacement showed largest values at constant distance from ground surface. The validation of foundation analysis improved with pack drain by computer program employed in this study selecting modified Cam-clay model was satisfactorily secured.

  • PDF

A chord error conforming tool path B-spline fitting method for NC machining based on energy minimization and LSPIA

  • He, Shanshan;Ou, Daojiang;Yan, Changya;Lee, Chen-Han
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.4
    • /
    • pp.218-232
    • /
    • 2015
  • Piecewise linear (G01-based) tool paths generated by CAM systems lack $G_1$ and $G_2$ continuity. The discontinuity causes vibration and unnecessary hesitation during machining. To ensure efficient high-speed machining, a method to improve the continuity of the tool paths is required, such as B-spline fitting that approximates G01 paths with B-spline curves. Conventional B-spline fitting approaches cannot be directly used for tool path B-spline fitting, because they have shortages such as numerical instability, lack of chord error constraint, and lack of assurance of a usable result. Progressive and Iterative Approximation for Least Squares (LSPIA) is an efficient method for data fitting that solves the numerical instability problem. However, it does not consider chord errors and needs more work to ensure ironclad results for commercial applications. In this paper, we use LSPIA method incorporating Energy term (ELSPIA) to avoid the numerical instability, and lower chord errors by using stretching energy term. We implement several algorithm improvements, including (1) an improved technique for initial control point determination over Dominant Point Method, (2) an algorithm that updates foot point parameters as needed, (3) analysis of the degrees of freedom of control points to insert new control points only when needed, (4) chord error refinement using a similar ELSPIA method with the above enhancements. The proposed approach can generate a shape-preserving B-spline curve. Experiments with data analysis and machining tests are presented for verification of quality and efficiency. Comparisons with other known solutions are included to evaluate the worthiness of the proposed solution.

A Study on the Development and Surface Roughness of Roller Cam SCM415 by 5-Axis Machining (5축 가공에 의한 SCM415 롤러 캠 개발과 표면조도 연구)

  • Kim, Jin Su;Lee, Dong Seop;Kang, Seong Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • In this study, we carried out the each lines of section, using GC (green silicon carbide) whetstone, the SCM415 material which separated by after and before heat treatments process, in 3+2 axis machining centers for integrated grinding after cutting end mill works, the spindle speed 8000 rpm and feed rate 150 mm/min. For the analysis of the centerline average roughness (Ra), we measured by 10 steps stages. Using Finite element analysis, we found the result of the load analysis effect of the assembly parts, when applied the 11 kg's load on both side of the ATC (Automatic tool change) arm. The result is as follows. For the centerline average roughness (Ra) in the non-heat treatment work pieces, are appeared the most favorable in the tenth section are $0.510{\mu}m$, that were shown in the near the straight line section which is the smallest deformation of curve. In addition, the bad surface roughness appears on the path is to long by changing angle, the more inclined depth of cut, because the chip discharging is not smoothly.

A STUDY OF DWARF GALAXIES EMBEDDED IN A LARGE-SCALE Hɪ RING IN THE LEO I GROUP

  • KIM, MYO JIN;CHUNG, AEREE;LEE, JONG CHUL;LIM, SUNGSOON;KIM, MINJIN;KO, JONGWAN;LEE, JOON HYEOP;YANG, SOUNG-CHUL;LEE, HYE-RAN
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.517-519
    • /
    • 2015
  • A large-scale neutral hydrogen ($H\small{I}$) ring serendipitously found in the Leo I galaxy group is 200 kpc in diameter with $M_{H\small{I}}{\sim}1.67{\times}10^9M_{\odot}$, unique in size in the Local Universe. It is still under debate where this $H\small{I}$ ring originated - whether it has formed out of the gas remaining after the formation of a galaxy group (primordial origin) or been stripped during galaxy-galaxy interactions (tidal origin). We are investigating the optical and $H\small{I}$ gas properties of the dwarf galaxies located within the gas ring in order to probe its formation mechanism. In this work, we present the photometric properties of the dwarfs inside the ring using the CFHT MegaCam $u^{\ast}$, $g^{\prime}$, $r^{\prime}$ and $i^{\prime}$-band data. We discuss the origin of the gas ring based on the stellar age and metal abundance of dwarf galaxies contained within it.

VR Image Shooting Considering Post-Production based Raw Format (원규격 기반 후반작업을 고려한 실사 VR 영상 촬영)

  • Kim, Chulhyun
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.866-875
    • /
    • 2018
  • With the popularity of VR content, actual image based VR 360-degree video production using various shooting devices has attracted attention in recent years. Requiring a lot of work, the existing VR content production was possible only at the level of the research institute, but the recent miniaturization of cameras has made the VR actual image shooting more common to the content creators. In this paper, we compare and study various VR contents distribute in today's context and analyze the strengths and weaknesses of robust actual image-based 360 video production in terms of cost. We are to point out the disadvantages that make it difficult for existing video shooting experts to use and suggest a solution for this. The experiment shooting proved that it can be operated more manually than action cam or integrated camera and 360-degree shooting on a raw format support camera is more suitable for film type post-production.

A Study on the Design of Multiple Object Movements Using Few Power Units and Machanisms (소수의 동력장치와 메커니즘을 이용한 다수의 객체움직임 디자인에 관한 연구)

  • Kang, Hee-Ra
    • Journal of Digital Convergence
    • /
    • v.18 no.12
    • /
    • pp.543-548
    • /
    • 2020
  • The purpose of this study is to implement various movements of multiple objects using a small number of power devices in producing a kinetic design, achieving an effect similar to a work comprised of multiple objects controlled using multiple power devices. While it is more typical to control various objects using multiple power devices, the use of multiple devices leads to higher costs and heavier overall weight. In addition, more power is required to operate the multiple power devices. This study applied a mechanism that allows multiple objects to perform various movements using a small number of power devices. The mechanism significantly reduces overall weight and power consumption. In addition, various movements could be expressed by increasing the rows and columns of objects through the use of the camshaft structure that changed the position and shape of the cam and the use of bevel gears. The significance of this study lies in presenting a new method of controlling multiple objects for designers involved in kinetic design.