• Title/Summary/Keyword: CAM(Computer-Aided Manufacturing)

Search Result 240, Processing Time 0.023 seconds

Chair-side CAD/CAM fabrication of a single-retainer resin bonded fixed dental prosthesis: a case report

  • Jurado, Carlos Alberto;Tsujimoto, Akimasa;Watanabe, Hidehiko;Villalobos-Tinoco, Jose;Garaicoa, Jorge Luis;Markham, Mark David;Barkmeier, Wayne Walter;Latta, Mark Andrew
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.15.1-15.7
    • /
    • 2020
  • This clinical report describes designing and fabricating a single-retainer resin-bonded fixed dental prosthesis with a chair-side computer-aided design/computer-aided manufacturing system. The whole procedure, from tooth extraction to final placement of the prosthesis, was completed in one day, and a single clinic visit. No clinical complications were found at the 2-year follow-up after placement of the restoration, and satisfactory functional and esthetic results were achieved.

Endocrown restorations for extensively damaged posterior teeth: clinical performance of three cases

  • Tzimas, Konstantinos;Tsiafitsa, Maria;Gerasimou, Paris;Tsitrou, Effrosyni
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.38.1-38.9
    • /
    • 2018
  • The restoration of endodontically treated teeth (ETT) with more than one cusp missing and thin remaining walls is challenging for the general practitioner. The use of posts combined with full coverage restorations is a well-established approach, yet not following the minimal invasive principles of adhesive dentistry. Endocrowns are indirect monoblock restorations that use the pulp chamber of the ETT for retention. In this study the fabrication of 4 endocrowns and their clinical performance will be discussed. Two clinical cases include computer-aided design/computer-aided manufacturing manufactured molar endocrowns (one feldspathic ceramic and one hybrid composite-ceramic restoration) and the other two are dental laboratory manufactured resin composite premolar endocrown restorations. The modified United States Public Health Service criteria were used to assess the clinical behavior of the restorations at different follow up periods. Endocrown restorations present a satisfactory clinical alternative, either by the use of resin composite or glass ceramic and hybrid materials. Specific guidelines with minimal alterations should be followed for an endocrown restoration to be successful. Due to limited evidence regarding the long term evaluation of this restorative technique, a careful selection of cases should be applied.

Review of clinical studies applying yttrium tetragonal zirconia polycrystal-based esthetic dental restoration (치과용 지르코니아로 제작된 심미보철물의 임상적 예후에 관한 문헌고찰)

  • Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.307-312
    • /
    • 2020
  • Application of ceramic materials for fabrication of dental restoration materials has been a focus of interest in the field of esthetic dentistry. The ceramic materials of choice are glass ceramics, spinel, alumina, and zirconia. The development of yttrium tetragonal zirconia polycrystal (YTZP)-based systems is a recent addition to all-ceramic systems that have high strength and are used for crowns and fixed partial dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-produced, YTZP-based systems are popular with respect to their esthetic appeal for use in stress-bearing regions. The highly esthetic nature of zirconia and its superior physical properties and biocompatibility have enabled the development of restorative systems that meet the demands of today's patients. Many in vitro trials have been performed on the use of zirconia; however, relatively fewer long-term clinical studies have been published on this subject. The use of zirconia frameworks for long-span fixed partial dentures is currently being evaluated; in the future, more in vivo research and long-term clinical studies are required to provide scientific evidence for drawing solid guidelines. Further clinical and in vitro studies are required to obtain data regarding the long-term clinical use of zirconia-based restorations.

Case series of implant-supported fixed prostheses using a high-performance polymer (PEKK) framework veneered with three different materials for six years (고기능성 폴리머(PEKK)를 프레임워크로 하는 임플란트 지지 고정성 보철물의 6년 경과관찰 증례)

  • Yeon-Kyung Park;Ji-Suk Shim;Jeong-Yol Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.20-27
    • /
    • 2024
  • As a high-performance polymer, Polyetherketoneketone (PEKK) has good biocompatibility and excellent physical properties and is used in several areas, including dentistry. Many successful cases of implant-supported fixed prostheses with a PEKK framework have been reported; however, a long-term observation of the reported cases and discussion of complications are not available. In this case report, we present three cases of implant-supported fixed prostheses with a PEKK framework veneered with composite resin, lithium disilicate crown, and high-impact polymethyl methacrylate (PMMA), and discuss their 6-year follow-up results.

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

Complete denture rehabilitation utilizing digital process: A case report (디지털 방식을 활용한 양악 총의치 수복 증례)

  • An, Yoojin;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.313-319
    • /
    • 2022
  • Complete dentures are one of the most basic treatment methods for the treatment of edentulous patients. The manufacturing process of traditional complete dentures goes through the steps of taking primary impressions, secondary impressions, jaw relation record, trying in wax denture, and final denture insertion. Multiple visits and complex manufacturing procedures are required, and errors may occur in each step. With the development of digital technology, manufacturing steps have been reduced by introducing digital technology to the denture treatment process. In the process of manufacturing dentures by introducing a digital process, a more precise work is possible using Computer-Aided Design, and it is possible to shorten the period of labor and reduce the number of visits. In this case, the anterior teeth arrangement of the patient's existing dentures was transferred to the final dentures using a digital method. After taking impression, try-in dentures were digitally fabricated and tried in the oral cavity to evaluate their retention in the oral cavity. Final dentures were manufactured by milling process. The number of visits was reduced, satisfactory retention and stability of dentures were obtained, and aesthetic recovery was achieved.

A Method for Generation of Grinding Map based on Automatic Mold Measurement (금형 자동측정에 의한 사상맵 생성)

  • Jeoung, Nam-Yeoung;Cho, Jin-Hyung;Oh, Hyun-Seung;Lee, Sae-Jae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.248-255
    • /
    • 2018
  • Ensuring the quality of molds is one of the major issues in mass production. In general, securing the quality of the molds is achieved by repeating grinding and die spotting after machining the molds based on engineer's decision. However, this heuristic method is affected by the engineer's skill and working environment. Therefore, a lot of time and resources are needed in order to ensure quality. In this study, ensuring the quality of molds using grinding map which is generated using automatic measurement is proposed. An automatic measuring system based on CMM (Coordinate Measuring Machine) is developed for measuring the molds. This system generates the measurement path automatically using the 3D CAD model of products. CAD (ComputerAided-Design), CAM (Computer-Aided-Manufacturing), and CAQ (Computer-Aided-Quality) technology is integrated using DMIS (Dimensional Measuring Interface Standard) format in the automatic measuring system. After measuring the molds, a grinding map is generated using the gap between the CAD model and measured values of mold. The grinding map displays the machining tendency and the required amount of grinding with values on a 3D map. Therefore, the quality of molds can be ensured with exactness and quickness based on the grinding map. This study shows that integrating the planning, measuring, and analyzing based on computer technology can solve the problem of quality assurance of mold using the proposed method, therefore the productivity can be increased.

Esthetic Restoration of Complicated Crown-Root Fractures Utilizing Orthodontic Extrusion (복합 치관-치근 파절의 교정적 정출술을 이용한 심미적 수복)

  • Kim, Minji;Kim, Jinyoung;Kim, Suhyun;Lim, Sumin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.60-69
    • /
    • 2016
  • Complicated crown-root fracture of permanent incisors cause esthetic, functional, and psychological problems to patients. Therefore, treatment is important and multidisciplinary treatment is required. This case report describes the clinical procedures involved in the treatment of trauma-induced complicated crown-root fractures in the maxillary incisor of two young patients. Conventional root canal treatment and apexification were performed in each patient. To expose the fracture margins to the supragingival level and to reestablish the biologic width, orthodontic extrusions with fixed appliances were performed followed by a retention period. During the retention period, fiber-optic posts and cores were built up and provisional crowns were placed. Finally, ceramic crowns manufactured using a computer-aided design/computer-aided manufacturing (CAD/CAM) system were placed. In both patients, the teeth presented satisfactory functional and esthetic outcomes without relapse. The periodontal tissues were healthy.

Practicality and prospect of full-zirconia restoration (풀지르코니아 수복물의 실용성과 전망)

  • Hwang, Jung-Won
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.2
    • /
    • pp.101-121
    • /
    • 2015
  • Zirconia polycrystalline (Y-TZP) showed better mechanical properties and superior resistance to fracture than other conventional dental ceramics. Zirconia-based ceramics have been successfully introduced into the clinic to fabricate fixed dental prostheses (FDPs), along with a dental computer-aided/computer-aided manufacturing (CAD/CAM) system. It has been clinically available as an alternative to the metal framework for fixed dental prostheses (FDPs). The most frequent clinical complication with zirconia-based FDPs was chipping of the veneering porcelain that was affected by many factors. Another option was full-contour zirconia FDPs using high translucent zirconia. Full-contour zirconia FDPs has many clinical advantages but it caused concern about the wear of antagonist enamel, because the hardness of Y-TZP was over double that of porcelain. However, many articles demonstrates that highly polished zirconia yielded lower antagonist wear compared with porcelains. In this article (1) advantages of full zirconia restorations, (2) clinical applications of zirconia restorations, (3) abutment preparation, (4) surface finish of zirconia restoration and antagonist enamel wear, (5) bond of zirconia with resin-based luting agents, (6) communication in clinical & lab.procedures for full zirconia restorations are reviewed.

Digital workflow of single visit full contour monolithic zirconia restoration with CEREC Omnicam intraoral scanner and fast zirconia sintering process (구강스캐너와 급속 지르코니아 소결을 이용한 당일 풀지르코니아 보철수복)

  • Lee, Soo Young
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.79-87
    • /
    • 2016
  • Single visit monolithic restoration can be proceed with digital workflow which consist of intraoral scanning, dental CAD(computer aided design) and restoration milling with CAM(Computer aided manufacturing). While zirconia has more than 900MPa of flexural strength compared with 400MPa for lithium disilicate, shortened fabricating time of lithium disilicate is considered to be a better choice for fabricating single visit full contour monolithic restoration. However, new zirconia materials which are TZI C(Dentsply Sirona) and LUXEN Enamel(Dental Max), new induction heating method of sintering furnace, and new sintering protocols for MoSi2 heating elements sintering furnace offer significantly reduction of full contour monolithic zirconia restoration fabrication time with greater translucency. These new developments lead single visit zirconia restoration in reality.