• 제목/요약/키워드: CAD reference model

검색결과 58건 처리시간 0.027초

3D모델을 이용한 비만체형 여성의 허리-배 부위 패턴 특성 연구 (Pattern Development of Waist / Abdominal Area of Obese Womem Using 3D Geometrical Model)

  • 김소영;홍경희
    • 한국의류학회지
    • /
    • 제29권7호
    • /
    • pp.1018-1026
    • /
    • 2005
  • Recent development of 3D scanner and software is regarded as a promising method of acquiring replicas from human body indirectly. It would be very helpful if we could predict the characteristics of 2D pattern from the simple parameters related to 3D shape for ordinary user. Therefore, in this study, investigation of 2D pattern of waist/abdominal area from the 3D geometrical model was conducted for the pattern development of waist nipper. To create body models and develop the surface of them, one ortho commonly used CAD/CAM program, IDEAS(UGS-plm solutions, USA) was used. As for the size of the models, the width, thickness, and circumference ranges of adult women's torso reported in National Anthropometric Survey of Korea (1997) were used as a standard model. Seven size variations were made by changing the width of the waist only, from 19 cm to 40 cm. Therefore, simulated body models include not only the normal body but also obese body who has wider waist and abdomen width than hip width. As results, it was found that the curvature of the unfolded 2D pattern around the abdominal area decreases as the waist width increases. As the width of the waist increases more and more, so that the comparative ratios around the torso becomes in abnormal ranges, there appears inflection points and the direction of curvature was changed. 2D Patterns obtained in this research were quantified by curvature, length of the curve and angle of deflection in the reference frame box for the convenience of the actual pattern making process. It was also possible to find that the shape of patterns of abnormal body resulted in a quite interesting change in the curves of 2D pattern, which could be applied to the custom made waist nipper for obese women.

DFSS에 의한 FPD용 높이 조절기구 설계 (Design of Height Adjustment Mechanism for Flat Panel Display by DFSS)

  • 조규열;정선환;최성대
    • 한국공작기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.92-97
    • /
    • 2007
  • This study was carried out to minimize the lifting force and to design the slim sized frame of a height adjustment mechanism. This unit is designed for the display devices in order to enhance the ergonomics for effective height adjustment as well as to achieve much slimmer frame for the pedestal. A tolerance analysis of 6 sigma was applied to achieve smooth lift at design stage not to change the tolerance specification of gap several times in a roller type of lifting mechanism at mass production stage. The specification of minimum gap and the target of production yield ratio were agreed with a quality team before tooling. A DFSS simulation on drawings had been done with reasonable tolerance and achievable standard deviation(${\sigma}$) several times until the target specification of gap and yield ratio was met. Once tolerance and deviation(${\sigma}$) were fixed tooling start was done successfully. A CAE method was applied to achieve a slim design. Design parameters were frozen when those parameters matched the reference strength data of standard model. Through those tolerance analysis and CAE simulation the number of tool modification was reduced and production yield ratio was raised up without arguing quality specification at production stage in the end.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologies

  • Leonardo Ciocca;Mattia Maltauro;Valerio Cimini;Lorenzo Breschi;Angela Montanari;Laura Anderlucci;Roberto Meneghello
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권1호
    • /
    • pp.22-32
    • /
    • 2023
  • PURPOSE. Digital technology has enabled improvements in the fitting accuracy of denture bases via milling techniques. The aim of this study was to evaluate the trueness and precision of digital and analog techniques for manufacturing complete dentures (CDs). MATERIALS AND METHODS. Sixty identical CDs were manufactured using different production protocols. Digital and analog technologies were compared using the reference geometric approach, and the Δ-error values of eight areas of interest (AOI) were calculated. For each AOI, a precise number of measurement points was selected according to sensitivity analyses to compare the Δ-error of trueness and precision between the original model and manufactured prosthesis. Three types of statistical analysis were performed: to calculate the intergroup cumulative difference among the three protocols, the intergroup among the AOIs, and the intragroup difference among AOIs. RESULTS. There was a statistically significant difference between the dentures made using the oversize process and injection molding process (P < .001), but no significant difference between the other two manufacturing methods (P = .1227). There was also a statistically significant difference between the dentures made using the monolithic process and the other two processes for all AOIs (P = .0061), but there was no significant difference between the other two processes (P = 1). Within each group, significant differences among the AOIs were observed. CONCLUSION. The monolithic process yielded better results, in terms of accuracy (trueness and precision), than the other groups, although all three processes led to dentures with Δ-error values well within the clinical tolerance limit.

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.

미국 공동주택의 건물 외피 에너지코드 검증을 위한 BIM 에너지 계획 방안 -뉴욕시 에너지 코드를 기준으로- (BIM Energy Efficiency Plan for Verification of Building Envelop Energy Code of Housing in USA - Based on the NYC Energy Conservation Code -)

  • 허진우
    • 문화기술의 융합
    • /
    • 제8권4호
    • /
    • pp.313-322
    • /
    • 2022
  • BIM의 생산성과 효율성 때문에 건축설계 방식으로 BIM을 선택하는 건축가들이 증가하고 있다. 또한 건물의 에너지 사용량에 대한 인식 제고와 환경에 대한 관심이 높아지면서 빌딩에너지 코드의 필요성에 대한 요구가 증가하고 있다. 현재 많이 사용하고 있는 2D CAD 설계방식으로는 건물 외피 에너지코드를 검정하는데 많은 시간과 노력이 소요되며 디자인 변경에 다른 즉각적인 대응이 어렵다. 이 연구의 목적은 BIM을 통한 건물 외피 에너지 모델링의 효율성을 보여주는 데 있다. 우리는 BIM을 통해 설계과정에서 디자인 변경에 따른 정보 값을 누락이나 재계산 과정 없이 동시에 산출할 수 있기 때문에 건물 외피 에너지코드 검증에서 생산성과 효율성을 높이는 데 기여할 수 있다. 연구의 절차는 다음과 같다. Revit 2011으로 만든 the Goldin at Essex Crossing 공동주택의 BIM을 사례 모델로 하여, 뉴욕시의 에너지 코드에 부합하기 위한 에너지 계획의 기준을 분석한다. Revit 모델의 설정을 통해 나온 결과 값과 뉴욕시의 에너지코드에서 요구하는 기준 값을 비교한다. 최종적으로 미국 에너지국 (U.S. Department of Energy)에서 제공하는 에너지 검증 프로그램인 COMcheck에 데이터값을 입력하여 건물 외피 에너지 성능이 뉴욕시 에너지 코드에 부합하는 지 여부를 체크한다.

CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구 (Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM)

  • 김서랑;김명주;박지만;김성균;허성주;곽재영
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.1-17
    • /
    • 2023
  • 목적: 본 연구의 목적은 레이져 신터링, 컴퓨터 밀링, 주조의 세 가지 방법으로 제작된 비귀금속 합금 코핑의 변연 형태에 따른 변연 적합도의 변화를 관찰하는 데 있다. 재료 및 방법: 서로 다른 두 개의 변연 형태를 정확히 재현하기 위해 3D Computer-aided Design을 이용하여 지대치 삭제의 원칙에 따라 지대치를 디자인한 다음, 티타늄 블럭을 컴퓨터 밀링하여 주모델을 제작하였다. 각각의 모델에 대하여 위의 3가지 제작 방식으로 비귀금속 합금 코핑을 12개씩 제작하여, 총 72개의 코핑을 제작하였다. 각 코핑은 지대치에 적합시켜서 공초점 레이저 주사 현미경으로 근심, 협측, 원심, 설측 변연의 변연 적합도를 150배율로 측정하였다. 결과: 레이져 신터링으로 제작한 코핑의 평균 변연 오차는 deep chamfer margin에서 11.8 ± 7.4 ㎛, rounded shoulder margin에서 6.3 ± 3.5 ㎛ 였고, 그 차이는 통계적으로 유의했다 (P < .0001). 컴퓨터 밀링으로 제작한 그룹에서는 deep chamfer margin에서 53.9 ± 27.8 ㎛, rounded shoulder margin에서 48.6 ± 30.0 ㎛였고, 변연 형태에 따른 유의한 차이가 없었다 (P = .279). 주조 방법으로 제작한 그룹은 deep chamfer margin에서 18.8 ± 20.2 ㎛, rounded shoulder margin 에서 30 ± 20.5 ㎛ 였고, 그 차이는 통계적으로 유의했다 (P = .0004). 결론: 이번 실험을 통하여, 다음과 같은 결론을 얻었다. 1. 변연의 형태에 따른 변연 적합도는 레이져 신터링이나 주조 방법으로 제작된 금속 코핑의 경우 변연 형태에 따라 유의한 차이가 있었다. 2. 레이져 신터링으로 제작한 금속 코핑에서 rounded shoulder margin이 deep chamfer margin보다 우수한 변연 적합도를 보였다. 3. 주조 방법으로 제작한 금속 코핑의 경우는 deep chamfer margin이 rounded shoulder margin보다 우수한 변연 적합도를 보였다. 4. 제작 방식에 따른 코핑의 변연 적합도는 레이져 신터링이 가장 양호하였고, 그 다음 주조 방법과 밀링 방법 순으로 변연 적합도 양호하였다. 이번 연구를 통해, 지대치의 변연 형태에 따른 금속 코핑의 변연 적합도의 변화를 관찰하였으며, 레이져 신터링으로 제작하거나 디지털 밀링한 왁스 패턴을 캐스팅한 경우에는 상관 관계가 있음을 확인하였다. 임상에 적용함에 있어 지대치의 변연 형태를 고려하여 제작 방식을 결정하는 것이 추천된다.

전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향 (The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression)

  • 김기백;이경탁;김혜영;김재홍
    • 치위생과학회지
    • /
    • 제12권6호
    • /
    • pp.617-623
    • /
    • 2012
  • 본 연구는 치과용 모형재 중 4형(type IV)석고와 스캔용(scannable)석고를 이용하여 작업모형을 제작한 후, 치과용 백색광 스캐너를 이용하여 3차원 디지털 모형으로 전환한 데이터의 계측지점간 거리를 측정하여, 그 결과 값을 토대로 이종의 치과용 석고가 3차원 디지털 모형의 크기재현 시 정확성여부를 비교하였다. 본 실험을 통하여 치과용 모형재에 따른 3차원 디지털 모형의 정확도를 확인함으로써 임상 적용의 가능성을 평가하였으며, 제한된 조건 하에서 수행된 본 연구에서 다음과 같은 결론을 얻었다. 1. 치과용 백색광 스캐너를 사용하여 주 모형과 두 종류의 모형재로 제작한 작업모형을 3차원 디지털 모형으로 전환한 후, 선계측의 값을 비교한 결과 전체적인 계측지점에서 모두 모형재로 제작된 작업모형이 작게 계측되는 경향을 보였다. 2. 각 모형별 동일한 계측지점의 계측값의 차이가 있는지 알아보기 위해 paired t-test의 시행결과, 모든 계측지점에서 통계적으로 유의한 차이를 보였다(p<0.05). 결론적으로 두 가지 석고 모두 통계적으로 적정한 수준의 정확성을 나타내지 않았으나, 오차 수준이 선행연구에 비추어 볼 때 임상적으로 수용 가능한 수준이라 생각된다. 전악 인상채득을 통한 디지털 모형의 정확성은 검증이 되었으나, 스캔용(scannable)석고에 대한 임상 효용성을 판단하기 위해 타 제품과의 성분 분석 비교연구나 실질적인 보철물 제작을 통한 적합도 평가를 통해 CAD/CAM 보철물 제작 시장점을 부각할 수 있는 연구가 뒷받침되어야 할 것으로 사료된다.

다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교 (Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods)

  • 이혁준;이하빈;노미준;김지환
    • 대한치과기공학회지
    • /
    • 제45권2호
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

정확한 기생 성분을 고려한 ITRS roadmap 기반 FinFET 공정 노드별 회로 성능 예측 (Circuit Performance Prediction of Scaled FinFET Following ITRS Roadmap based on Accurate Parasitic Compact Model)

  • 최경근;권기원;김소영
    • 전자공학회논문지
    • /
    • 제52권10호
    • /
    • pp.33-46
    • /
    • 2015
  • 본 논문에서는 ITRS(International Technology Roadmap for Semiconductors)를 따라 스케일 다운된 FinFET 소자의 디지털 및 아날로그 회로의 성능을 예측했다. 회로 성능의 정확한 예측을 위해 기생 커패시턴스와 기생 저항 모델을 개발해 3D Technology CAD 해석 결과와 비교해 오차를 2 % 미만으로 달성했다. 기생 커패시턴스 모델은 conformal mapping 방식을 기반으로 모델링 되었으며, 기생 저항 모델은 BSIM-CMG에 내장된 기생 저항 모델을 핀 확장 영역 구조 변수($L_{ext}$) 변화에 따른 기생 저항 성분 변화를 반영 할 수 있도록 개선했다. 또한, 공정 단위 변화에 대해 소자의 전압전류의 DC 특성을 반영하기 위해 BSIM-CMG 모델의 DC 피팅을 진행하는 알고리즘을 개발했다. BSIM-CMG에 내장된 기생 모델을 본 연구에서 개발한 저항과 커패시턴스 모델로 대체해 압축 모델 내부에 구현하여, SPICE 시뮬레이션을 통해 스케일 다운된 FinFET 소자의 $f_T$, $f_{MAX}$, 그리고 링 오실레이터와 공통 소스 증폭기의 기생 성분으로 인한 특성변화를 분석했다. 정확한 기생 성분 모델을 적용해 5 nm FinFET 소자까지 회로 특성을 정량적으로 제시했다. 공정 단위가 감소함에 따라 소자의 DC 특성이 개선될 뿐만 아니라 기생 성분의 영향이 감소하여, 회로 특성이 향상됨을 예측했다.