• Title/Summary/Keyword: CAD/CAM dentistry

Search Result 455, Processing Time 0.031 seconds

Implant stability installed with CAD-CAM assisted flapless surgery : A pilot study (CAD-CAM assisted flapless 수술법으로 식립된 임플란트의 안정성 : 기초연구)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Kashiwagi, Kosuke;Kawazoe, Takayoshi;Tanaka, Masahiro
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.405-413
    • /
    • 2011
  • It was proposed that technologies derived from CAD-CAM and computed tomography may be useful for flapless implant treatment procedures. The aims of this study were to validate the reliability of this concept in a prospective 12-month clinical study. Twelve patients with fully edentulous areas in their mandibles were included in this study. A total of 71 implants were inserted in interforaminal regions by use of a CAD/CAM drill template($NobelGuide^{TM}$), specially designed for flapless implant surgery. To assess the degree of pain and discomfort, the patients were examined at 2 days and 1 week after surgery. Patient satisfaction and implant functionality were further evaluated at follow-up intervals of 1, 3, 6, and 12 months postoperatively. One implant failed early in 1 patient. All of the other implants were in a good functional state throughout the study. The mean marginal bone loss after 1 year of follow-up was 0.3 mm (SD, 0.1) at center, 0.5 mm (SD, 0.1) at canine and 0.7 mm (SD, 0.2) at distal fixtures, respectively. Statistically, there was not significant differences among each sites(P>.05)The mean ISQ change after 1 year of follow-up was -1.05 (SD, 2.76) at center, -0.85 (SD, 2.59) at canine and -1.27 (SD, 2.18) at distal fixtures, respectively. This prospective pilot study showed that the use of CAD/CAM technology and flapless implant surgery may be considered reliable for fully edentulous mandible of patients.

Maxillar implant-retained overdenture using CAD/CAM milled zirconia bar with PEKK sleeve: a case report (상악 무치악 환자에서 가공 지르코니아 바와 PEKK 슬리브를 이용한 임플란트 피개의치 증례)

  • Ju, Jin-Seok;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.307-313
    • /
    • 2017
  • The object of this case report is to introduce milled zirconia bar and PEKK female part made by CAD/CAM technology for bar attachment implant supported overdenture in maxillary edentulous patients. For over 2 years, in terms of function and esthetics, satisfactory result was obtained. Esthetically and functionally satisfactory results were obtained in periodic follow up check.

Restoration of partial removable dental prosthesis after fabricating of surveyed crowns utilizing electronic surveying: a case report (전자 서베잉을 이용한 서베이드 크라운 제작 후 국소의치 수복: 증례보고)

  • Min, Byungkwee;Jun, Daejeon;Yang, Hongso;Park, Sangwon;Lim, Hyunpil;Yun, Kwidug;Park, Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.135-142
    • /
    • 2017
  • Adoption of CAD/CAM milling in dentistry has allowed production of more analytic and precise prosthesis. Such precision enables definite path of insertion and undercut to be provided in removable partial denture especially when designing a surveyed crown on an abutment tooth. This case is about the production of surveyed crown with proper path of insertion utilizing CAD/CAM electronic surveying method on a patient with edentulous maxilla. Resulting removable partial denture fit well and showed acceptable stability and retention with no clinical problem.

Microtensile bond strength of CAD/CAM-fabricated polymer-ceramics to different adhesive resin cements

  • Sadighpour, Leyla;Geramipanah, Farideh;Ghasri, Zahra;Neshatian, Mehrnoosh
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.40.1-40.10
    • /
    • 2018
  • Objectives: This study evaluated the microtensile bond strength (${\mu}TBS$) of polymer-ceramic and indirect composite resin with 3 classes of resin cements. Materials and Methods: Two computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated polymer-ceramics (Enamic [ENA; Vita] and Lava Ultimate [LAV; 3M ESPE]) and a laboratory indirect composite resin (Gradia [GRA; GC Corp.]) were equally divided into 6 groups (n = 18) with 3 classes of resin cements: Variolink N (VAR; Vivadent), RelyX U200 (RXU; 3M ESPE), and Panavia F2 (PAN; Kuraray). The ${\mu}TBS$ values were compared between groups by 2-way analysis of variance and the post hoc Tamhane test (${\alpha}=0.05$). Results: Restorative materials and resin cements significantly influenced ${\mu}TBS$ (p < 0.05). In the GRA group, the highest ${\mu}TBS$ was found with RXU ($27.40{\pm}5.39N$) and the lowest with VAR ($13.54{\pm}6.04N$) (p < 0.05). Similar trends were observed in the ENA group. In the LAV group, the highest ${\mu}TBS$ was observed with VAR ($27.45{\pm}5.84N$) and the lowest with PAN ($10.67{\pm}4.37N$) (p < 0.05). PAN had comparable results to those of ENA and GRA, whereas the ${\mu}TBS$ values were significantly lower with LAV (p = 0.001). The highest bond strength of RXU was found with GRA ($27.40{\pm}5.39N$, p = 0.001). PAN showed the lowest ${\mu}TBS$ with LAV ($10.67{\pm}4.37N$; p < 0.001). Conclusions: When applied according to the manufacturers' recommendations, the ${\mu}TBS$ of polymer-ceramic CAD/CAM materials and indirect composites is influenced by the luting cements.

Full mouth rehabilitation in edentulous patient with unstable mandibular position using flat table treatment dentures and CAD-CAM technology (치료의치와 CAD-CAM 기술을 이용한 불안정한 하악위를 가진 완전 무치악 환자의 치료 증례)

  • Kim, Yuyeon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.330-338
    • /
    • 2022
  • For edentulous patients with unstable mandibular movements and abnormal facial features due to condylar fractures and morphological abnormalities, it is important to find a stable mandibular position. In this case, the patient's facial improvement, mandibular movement stability, and denture stability were improved by using flat table treatment dentures. In addition, computer-aided design/manufacturing (CAD-CAM) technology was used in denture fabrication to maintain the vertical dimension and lip support of flat table treatment dentures, we report good results in improving the patient's discomfort.

Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns

  • Pak, Hyun-Soon;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • PURPOSE. Marginal fit is a very important factor considering the restoration's long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system). MATERIALS AND METHODS. 20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test. RESULTS. The means and standard deviations of the marginal fit were $61.52{\pm}2.88{\mu}m$ for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and $83.15{\pm}3.51{\mu}m$ after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of $62.22{\pm}1.78{\mu}m$ before porcelain veneering and $82.03{\pm}1.85{\mu}m$ after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well. CONCLUSION. The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.

Space maintainer using CAD/CAM system without a band: a case report (CAD/CAM 시스템을 이용하여 band 없이 공간유지 장치를 제작한 증례)

  • Eun-Sook Kang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.100-106
    • /
    • 2024
  • Early interceptive orthodontic interventions are often started in the developing dentition to guide normal occlusion. The simplest way to prevent eruption failure from deciduous tooth loss is to fix a space maintainer such as a band and loop. Band and loop space maintainer has several problems like cement loss, demineralization, locking of the adjacent tooth, and needs to take a pickup impression of the band. Computer-assisted design/computer-assisted manufacturing (CAD/CAM) space maintainer without band was developed to solve these problems. This case report describes successful eruption of the mandibular second premolar using CAD/CAM without a band.

A study on the accuracy of zirconia copings using dental CAD / CAM system (치과용 CAD/CAM 시스템을 이용한 지르코니아 코핑의 정확성에 관한 연구)

  • Yoon, Seong-Geun;Choi, Byung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.137-145
    • /
    • 2011
  • Purpose: To evaluate the accuracy of zirconia copings in terms of clinical verified for the clinical application of CAD/CAM. Methods: Zirconia copings (n=5) were prepared using CAD/CAM system and were sintered using the relevant electrical induction furnace, which uses a 2h sintering program with a maximum temperature of $1500^{\circ}C$. The copings placed at the models and the interval values were measured. Results: The meas interval values between the die and the zirconia copings were $44.14{\mu}m$(A), $44.57{\mu}m$(B), $44.72{\mu}m$(C). 51.05 ${\mu}m$(D). Conclusion: The maximum interval values between the die and the zirconia copings were $51.3{\mu}m$ which is acceptable for clinical use. ${\mu}m$ Proper understanding of the test conditions will help enhancing the accuracy of zirconia coping.

A study on the Flexural strength of zirconia CAD/CAM block (지르코니아 CAD/CAM block의 강도에 관한 연구)

  • Lee, Jung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.65-69
    • /
    • 2008
  • Recently, zirconia is widely used in the field of dental ceramics thanks to the proliferation of CAD/CAM systems. Accordingly, different types of zirconia block are being solid in the market. However, there are no precise, objective standards for properties of zirconia. This study concerns the flexural strength of zirconia ceramic for CAD/CAM block. The test specimens used for this study were ZirBlank(Acucera), ZirBlank shade(Acucera), VITA, Cercon(Densply) and Cerasys. The test results suggest that ZirBlank shade block shows the highest flexural strength and density among the zirconia blocks tested. Its flexural strength was $971{\pm}58MPa$ and its density was 99.89%. On the other hand, Cerasys block shows the lowest flexural strength of $576{\pm}36MPa$ and the lowest density of 94.85%. Given all, the density of the specimens is found to be directly proportional to strength and inversely to grain size.

  • PDF

Treatment of upper and lower 3D printing CAD-CAM dentures using the POP (PNUD Occlusal Plane) Bow system, a prefabricated occlusal plane transfer device: A case report (조립식 교합 평면 인기 장치 POP (PNUD Occlusal Plane) Bow 시스템을 이용한 3D 프린팅 CAD-CAM 의치치료 증례)

  • Seol-Hwa Lee;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.44-54
    • /
    • 2023
  • In order to manufacture functional and esthetic prostheses, it is essential to accurately transmit information about the patient's occlusal plane. In particular, in the case of a completely edentulous patient, the occlusal plane is very important to correctly support the soft tissue, to achieve aesthetic harmony with the facial appearance, and to properly pronounce it, and to form a balanced occlusal relationship for stable mastication. In the conventional method, various facebow systems were used to transmit patient's information from the clinic to the laboratory, but there were several limitations in the process of transferring them to CAD. To simplify this process, a prefabricated POP (PNUD Occlusal Plane) Bow system was recently developed. In this case, a CAD-CAM (Computer-aided design-computer-aided manufacturing) treatment dentures reflecting the patient's occlusal plane information was manufactured using the POP Bow system during the treatment of a completely edentulous patient, and aesthetic and functional satisfaction was obtained.