DOI QR코드

DOI QR Code

Restoration of partial removable dental prosthesis after fabricating of surveyed crowns utilizing electronic surveying: a case report

전자 서베잉을 이용한 서베이드 크라운 제작 후 국소의치 수복: 증례보고

  • Min, Byungkwee (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Jun, Daejeon (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Yang, Hongso (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Park, Sangwon (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Lim, Hyunpil (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Yun, Kwidug (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Park, Chan (Department of Prosthodontics, School of Dentistry, Chonnam National University)
  • 민병귀 (전남대학교 치의학전문대학원 보철학교실) ;
  • 전대전 (전남대학교 치의학전문대학원 보철학교실) ;
  • 양홍서 (전남대학교 치의학전문대학원 보철학교실) ;
  • 박상원 (전남대학교 치의학전문대학원 보철학교실) ;
  • 임현필 (전남대학교 치의학전문대학원 보철학교실) ;
  • 윤귀덕 (전남대학교 치의학전문대학원 보철학교실) ;
  • 박찬 (전남대학교 치의학전문대학원 보철학교실)
  • Received : 2016.11.28
  • Accepted : 2017.04.10
  • Published : 2017.06.30

Abstract

Adoption of CAD/CAM milling in dentistry has allowed production of more analytic and precise prosthesis. Such precision enables definite path of insertion and undercut to be provided in removable partial denture especially when designing a surveyed crown on an abutment tooth. This case is about the production of surveyed crown with proper path of insertion utilizing CAD/CAM electronic surveying method on a patient with edentulous maxilla. Resulting removable partial denture fit well and showed acceptable stability and retention with no clinical problem.

컴퓨터를 이용한 CAD/CAM milling 방식이 치과 분야에도 적용됨에 따라 보다 분석적이고 정밀한 보철물이 제작 가능하게 되었다. 특히, 국소의치의 지대치로 사용되는 서베이드 크라운을 제작하는데 있어 이러한 디지털 방식의 정밀함은 국소의치의 삽입철거로와 언더컷 등이 정확하게 부여될 수 있게 한다. 본 증례는 상악의 다수 치아 상실을 보이는 환자에서 CAD/CAM을 이용하여 전자 서베잉을 통해 적절한 삽입철거로를 부여하고 지르코니아 서베이드 크라운을 제작하였다. 국소의치의 적합도는 우수했으며, 장착 후 안정성과 착탈 시의 유지력 또한 임상에서 적용하는 데에 문제가 없었다.

Keywords

References

  1. Maroso DJ, Schmidt JR, Blustein R. A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms. J Prosthet Dent 1981;45:14-7. https://doi.org/10.1016/0022-3913(81)90005-6
  2. Bezzon OL, Mattos MG, Ribeiro RF. Surveying removable partial dentures: the importance of guiding planes and path of insertion for stability. J Prosthet Dent 1997;78:412-8. https://doi.org/10.1016/S0022-3913(97)70051-9
  3. Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based threeunit fixed partial dentures: a laboratory study. Int J Prosthodont 2001;14:231-8.
  4. Christel P, Meunier A, Heller M, Torre JP, Peille CN. Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. J Biomed Mater Res 1989;23:45-61. https://doi.org/10.1002/jbm.820230105
  5. Han J, Wang Y, Lu P. A preliminary report of designing removable partial denture frameworks using a specifically developed software package. Int J Prosthodont 2010;23:370-5.
  6. Eggbeer D, Bibb R, Williams R. The computeraided design and rapid prototyping fabrication of removable partial denture frameworks. Proc Inst Mech Eng H 2005;219:195-202.
  7. Miyazaki T, Nakamura T, Matsumura H, Ban S, Kobayashi T. Current status of zirconia restoration. J Prosthodont Res 2013;57:236-61. https://doi.org/10.1016/j.jpor.2013.09.001
  8. Baldissara P, Llukacej A, Ciocca L, Valandro FL, Scotti R. Translucency of zirconia copings made with different CAD/CAM systems. J Prosthet Dent 2010;104:6-12. https://doi.org/10.1016/S0022-3913(10)60086-8
  9. Williams RJ, Bibb R, Eggbeer D, Collis J. Use of CAD/CAM technology to fabricate a removable partial denture framework. J Prosthet Dent 2006; 96:96-9. https://doi.org/10.1016/j.prosdent.2006.05.029
  10. Yadroitsev I, Bertrand P, Smurov I. Parametric analysis of the selective laser melting process. Appl Surf Sci 2007;253:8064-9. https://doi.org/10.1016/j.apsusc.2007.02.088
  11. Hong YS, Park EJ, Kim SK, Koak JY, Heo SJ, Park JM. Surveyed restoration and RPD framework design utilizing electronic surveying. J Korean Acad Prosthodont 2011;49:354-61. https://doi.org/10.4047/jkap.2011.49.4.354