• Title/Summary/Keyword: CAD/CAM 지대주

Search Result 32, Processing Time 0.025 seconds

A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment (기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교)

  • Kim, Jong-Wook;Heo, Yu-Ri;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.276-283
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the fit and screw joint stability between Ready-made abutment and CAD-CAM custom-made abutment. Materials and methods: Osstem implant system was used. Ready-made abutment (Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea), CAD-CAM custom-made abutment (CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea) and domestically manufactured CAD-CAM custom-made abutment (Myplant, Raphabio Co., Seoul, Korea) were fabricated five each and screws were provided by each company. Fixture and abutments were tightening with 30Ncm according to the manufacturer's instruction and then preloding reverse torque values were measured 3 times repeatedly. Kruskal-Wallis test was used for statistical analysis of the preloading reverse torque values (${\alpha}=.05$). After specimens were embedded into epoxy resin, wet cutting and polishing was performed and FE-SEM imaging was performed, on the contact interface. Results: The pre-loading reverse torque values were $26.0{\pm}0.30Ncm$ (ready-made abutment; Transfer abutment) and $26.3{\pm}0.32Ncm$ (CAD-CAM custom-made abutment; CustomFit abutment) and $24.7{\pm}0.67Ncm$ (CAD-CAM custom-made abutment; Myplant). The domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) presented lower pre-loading reverse torque value with statistically significant difference than that of the ready-made abutment (Transfer abutment) and CAD-CAM custom-made abutment (CustomFit abutment) manufactured from the same company (P=.027) and showed marginal gap in the fixture-abutment interface. Conclusion: Within the limitation of the present in-vitro study, in domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) showed lower screw joint stability and fitness between fixture and abutment.

Fit analysis of CAD-CAM custom abutment using micro-CT (Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석)

  • Min, Gwang-Seok;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.370-378
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate screw joint stability and sagittal fit between internal connection implant fixtures of two different manufacturers and customized abutments. Materials and methods: Internal connection implant systems from two different manufacturers (Biomet 3i system, Astra Tech system) were selected for this study (n=24 for each implant system, total n=48). For 3i implant system, half of the implants were connected with Ti ready-made abutments and the other half implants were connected with Ti CAD-CAM custom ones of domestic-make (Myplant, Raphabio Co., Seoul, Korea) and were classified into Group 1 and Group 2 respectively. Astra implants were divided into Group 3 and Group 4 in the same way. Micro-CT sagittal imaging was performed for fit analysis of interfaces and preloading reverse torque values (RTV) were measured. Results: In the contact length of fixture-abutment interface, there were no significant differences not only between Group 1 and Group 2 but also between Group 3 and Group 4 (Mann-Whitney test, P>.05). However, Group 2 and Group 4 showed higher contact length significantly than Group 1 and Group 3 in abutment-screw interface as well as fixture-screw one (Mann-Whitney test, P<.05). In addition, RTV was lower in CAD-CAM custom abutments compared to ready-made ones (Student t-test, P<.05). Conclusion: It is considered that domestically manufactured CAD-CAM custom abutments have similar fit at the fixture abutment interface and it could be used clinically. However, RTV of CAD-CAM custom abutments should be improved for the increase of clinical application.

Radiographic evaluation of computer aided design/computer aided manufacturing (CAD/CAM) customized abutment of implant (CAD/CAM으로 제작된 임플란트 맞춤형 지대주의 방사선학적 평가)

  • Yun, Tae-Gyeong;Lee, Gyeong-Je;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.258-263
    • /
    • 2017
  • Purpose: In this study, the retrospective radiographic study is executed to evaluate amount of bone loss of various conditions in patients using customized abutment for 4 years of follow-up. Materials and methods: The subjects of this study were implant fixed dental prosthesis using CAD/CAM customized abutments. CAD/CAM customized abutment and fixed dental prosthesis were manufactured by the Prosthodontics Department of Chosun University Dental Hospital from August 1, 2011 to July 31, 2012. Radiological assessments were performed on the patients who were treated by the fixed prosthodontics. After each treatment, a retrospective study was performed for a total of 4 years at 3 months, 6 months, 1 year, 2 years, 3 years, and 4 years. Results: As a result of the study, the customized abutment using CAD/CAM showed less bone loss than the results of existing research. There was no statistically significant differences at alveolar bone loss between splinting group and non-splinting group (respectively 0.27 mm, 0.5 mm). Also, there were statistically significant differences at alveolar bone loss in mx. anterior, mx. posterior, mn. anterior and mn. posterior part (respectively 1.37 mm, 0.39 mm, 0.00 mm, 0.30 mm). Conclusion: The customized abutment using CAD/CAM showed less bone loss than the results of existing research, there were statistically significant differences at alveolar bone loss in implant positions.

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

Regeneration of emergence profile with soft tissue graft and wide computer aided design/computer aided mamufacturing abutments: a clinical report (연조직 이식술과 넓은 computer aided design/computer aided mamufacturing 지대주를 이용한 임플란트 고정성 보철물의 출현윤곽 재현)

  • Kim, Min-Kyung;Lee, Ji-Hun;Ahn, Seung-Geun;Kim, Kyung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.364-370
    • /
    • 2015
  • Fixed restoration using implants for patients with posterior partial edentulism is generalized technique. As patient demands increase, the functional and esthetic implant restoration to achieve similar results to lost natural teeth is becoming an important issue. It is inevitable to use customized CAD/CAM abutments rather than ready-made abutments for the creation of implant prosthesis which closely resembles natural teeth. Using CAD/CAM abutment made it possible to obtain natural emergency profiles for posterior implant prostheses, ensuring more comfortable, efficient management of oral hygiene. However, keratinized gingiva with sufficient width and height for a natural emergence profile is required to use a large diameter CAD/CAM abutment which ensures stability and esthetics of hard/soft tissue around the implants. In this case, for esthetical and functional implant zirconia prosthesis, soft tissue graft was performed and customized CAD/CAM abutments were used following ridge augmentation, sinus graft and implantation. Satisfactory results were obtained functionally and esthetically through periodic clinical evaluation, and I hereby report this case.

Rehabilitation of edentulous maxilla with implant-supported milled bar overdenture using CAD/CAM customized abutment: A case report (CAD/CAM 맞춤형 지대주를 이용한 milled-bar 피개의치 증례)

  • Ji, Woon;Chang, Jae-Seung;Kwon, Joo-Hyun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.146-151
    • /
    • 2016
  • In patients with fully edentulous maxilla, fabrication of implant-supported overdenture can be a viable treatment option, when a minimum of six implants were strategically placed. Among several attachment systems used for implant-supported overdentures, milled-bars prevent rotational movement of denture, thus showing great stability, and have the advantage of splinting multiple implants with each other. In this case report, a milled-bar supported overdenture was fabricated for a patient suffering from condition of fully edentulous maxilla with severe ridge resorption in the anterior residual ridge. Seven implants composed of three different systems were effectively utilized by CAD/CAM customized abutment and cement-retained milled bar.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

Submucosal zirconia implant prosthesis fabricated with CAD/CAM (CAD/CAM으로 제작한 점막하 지르코니아 임플란트 보철 수복 증례)

  • Chang, Jae-Seung;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.352-358
    • /
    • 2014
  • They have been recently introduced many aesthetic implant prosthesis using with zirconia and CAD/CAM. However, there are many limitations in their gingival and occlusal region. In this case, submucosal zirconia implant prosthesis were fabricated with CAD/CAM system. The connection of these screw cement retained prosthesis and titanium abutment was designed to 1mm above the fixture. The clinical results were satisfactory on the aesthetics and function.

Evaluation on machining accuracy according to convergence angle and radius of curvature value used for fabricating custom abutments (맞춤형 지대주 제작에 사용되는 수렴 각과 곡률 반경의 값에 따른 가공 정확도 평가)

  • Hong, Min-Ho;Choi, Sung-Min;Kwon, Tae-Yub
    • Korean Journal of Dental Materials
    • /
    • v.44 no.4
    • /
    • pp.329-336
    • /
    • 2017
  • This study evaluates the machining accuracy of the custom abutment design according to the selected convergence angle and radius of curvature value in the CAD program. Ten custom abutments were designed based on dental CAD. And then, the fabricated custom abutment was scanned ten times using a contact scanner. The data of the scanned custom abutment was saved as "Test STL" file. The Geomagic studio software was used to superposition each exported as an "Test STL" file with the CAD-reference-model STL file (CRM) specified by the same name. In the experimental results, the A8 group (convergence angle $8^{\circ}$) showed lower error than the A4 group (convergence angle $4^{\circ}$) . In addition, the higher the radius of curvature, the less error in the top and chamfer regions of the custom abutment (p< 0.05). Overall, the convergence angle and radius of curvature value in the custom abutment design were found to affect the machining accuracy.

The use of zirconia hybrid abutment for the anterior esthetic restoration and anterior implant utilizing CAD/CAM technology (캐드캠 기능을 이용한 전치부 심미 수복 및 전치부 임플란트에서 지르코니아 링크 지대주(Hybrid abutment)의 사용)

  • Kim, Jongyub
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.9-21
    • /
    • 2013
  • Aesthetics means differ from cultures and times and also differ from each person's own thinking. But as a restorative dentist who works for esthetic areas, we need to have certain principles and rationale. Some functions in CAD/CAM looks very useful to match harmonious shape to adjacent teeth and also very effective and efficient when compare to the traditional laboratory technics. Also we will discuss about link abutment (Titanium-Zirconia abutment) which we need for dental implant placed anterior area where the soft tissue is thin.