• Title/Summary/Keyword: C1-2 instability

Search Result 173, Processing Time 0.026 seconds

A Case of Intradiscal Oxygen-ozone Injection Therapy for Cervical Herniated Intervertebral Disc in a Dog (개에서 탈출된 경추디스크에 대한 디스크내 오존가스 주입 치료)

  • Jang, Ha-Young;Lee, Jun-Sub;Lee, Bo-Ra;Kim, Kyung-Hee;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.3
    • /
    • pp.273-275
    • /
    • 2009
  • A 6-year-old castrated male Shih-tzu was presented because of a 1-month history of progressive tetraplegia. On the basis of the findings of neurological examination, radiographs and magnetic resonance imaging, herniated intervertebral disc of C4-C5, C5-C6 and C6-C7 compressed spinal cord. The oxygen-ozone was intra-operatively injected into the C4-C5 and C6-C7 intervertebral disc and a ventral decompression performed at C5-C6 intervertebral space. Immediately after the surgery, neck pain was disappeared and three weeks after surgery, there was complete resolution of the neurological deficits with normal gaits. On magnetic resonance images at 2-month after surgery, herniated disc materials of C5-C6 and C6-C7 were completely removed and that of C4-C5 remarkably reduced. Consequently decompression which was performed at all of the three lesions resulted in good clinical outcome without additional internal fixation for minimizing postoperative instability.

Clinical Experiences and Usefulness of Cervical Posterior Stabilization with Polyaxial Screw-Rod System

  • Hwang, In-Chang;Kang, Dong-Ho;Han, Jong-Woo;Park, In-Sung;Lee, Chul-Hee;Park, Sun-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.311-316
    • /
    • 2007
  • Objective : The objective of this study is to investigate the safety, surgical efficacy, and advantages of a polyaxial screw-rod system for posterior occipitocervicothoracic arthrodesis. Methods : Charts and radiographs of 32 patients who underwent posterior cervical fixation between October 2004 and February 2006 were retrospectively reviewed. Posterior cervical polyaxial screw-rod fixation was applied on the cervical spine and/or upper thoracic spine. The surgical indication was fracture or dislocation in 18, C1-2 ligamentous injury with trauma in 5, atlantoaxial instability by rheumatoid arthritis (RA) or diffuse idiopathic skeletal hyperostosis (DISH) in 4, cervical spondylosis with myelopathy in 4, and spinal metastatic tumor in 1. The patients were followed up and evaluated based on their clinical status and radiographs at 1, 3, 6 months and 1 year after surgery. Results : A total of 189 screws were implanted in 32 patients. Fixation was carried out over an average of 3.3 spinal segment (range, 2 to 7). The mean follow-up interval was 20.2 months. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-7 lateral masses, as well as the lower cervical and upper thoracic pedicles. Satisfactory bony fusion and reduction were achieved and confirmed in postoperative flexion-extension lateral radiographs and computed tomography (CT) scans in all cases. Revision surgery was required in two cases due to deep wound infection. One case needed a skin graft due to necrotic change. There was one case of kyphotic change due to adjacent segmental degeneration. There were no other complications, such as cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, or implant failure, and there were no cases of postoperative radiculopathy due to foraminal stenosis. Conclusion : Posterior cervical stabilization with a polyaxial screw-rod system is a safe and reliable technique that appears to offer several advantages over existing methods. Further biomechanical testings and clinical experiences are needed in order to determine the true benefits of this procedure.

Improvement of the performance of SPPCM using mixed polarized beam and cylindrical lens (혼합 편광빔과 원주면렌즈를 사용한 SPPCM의 성능 개선)

  • Yi, Eun-Hyeong;Kim, Seong-Wan;Kim, Cheol-Su;Kim, Jong-Yun;Lee, Seung-Hee;Lee, Soo-Joong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.56-63
    • /
    • 1999
  • Conventional method to improve the response time of the Cat-SPPCM was to increase fanning beam using cylindrical lens. But, in this case the temporal instability of this SPPCM is increased, and fanning beam plays a role as noise, so that it decreases the reflectivity. Thus, fanning beam must be controlled to improve the properties of SPPCM. In this paper, we propose the method to increase the reflectivity of SPPCM and decrease the response time by focusing line-shaped input beam into photorefractive crystal using cylindrical lens and decrease the temporal instability of output beam by using mixed-polarized beam instead of simple extraordinary polarized beam. Optical experiments show that the reflectivity of proposed SPPCM is increased twice and the response time is reduced by 15 times. Also, we observed that the temporal instability of SPPCM is reduced when the polarization angle of the mixed-polarized beam is between $10^{\circ}$ and $30^{\circ}$ . We used a $45^{\circ}-cut\;BaTiO_3$ crystal which has high electro-optical coefficients in optical experiments.

  • PDF

Molecular Cloning of cDNA Encoding a Putative Eugenol Synthase in Tomato (Solanum lycopersicum 'Micro-Tom') and Prediction of 3D Structure and Physiochemical Properties (토마토 'Micro-Tom' 과실의 eugenol synthase 유전자 클로닝, 단백질의 3차 구조 및 생리화학적 특성 예측)

  • Kang, Seung-Won;Seo, Sang-Gyu;Lee, Tai-Ho;Lee, Gung-Pyo
    • Journal of agriculture & life science
    • /
    • v.46 no.4
    • /
    • pp.9-20
    • /
    • 2012
  • Eugenol is a volatile compound synthesized by eugenol synthase in various plants and belongs to phenylpropene compounds. However, characteristics of eugenol synthase in tomato has not been known. Therefore, we cloned a full length cDNA of a putative eugenol synthase from tomato 'Micro-Tom' using rapid amplification of cDNA ends (RACE) technique and named a clone SlEGS. Open reading frame of SlEGS was 921bp long and its deduced amino acid sequence was 307bp. The BLAST analysis indicated that SlEGS shared high similarity with PhEGS1 (67.1%) and CbEGS2 (69.4%). Amino acid composition of SlEGS was determined by CLC genomics workbench tool and 3D structure of SlEGS was constructed by homology modeling using Swiss-PDB viewer and validated using PROCHECK and ProSA-web tool. In addition, the physiochemical properties of SlEGS was evaluated using ExPASy's ProtParam tool. Molecular weight was 33.93kDa and isoelectric point was 5.85 showing acidic nature. Other properties such as extinction coefficient, instability index, aliphatic index, and grand average hydropathy was also analyzed.

Performance Assessment on Temperature Calibration Capability of the Calibration Laboratories Using High-Precision Platinum Resistance Thermometers (고정밀 백금저항온도계를 이용한 교정기관의 온도교정능력 수행평가)

  • Gam, Kee Sool;Lee, Young Hee;Yang, Inseok
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.415-420
    • /
    • 2013
  • Calibration capabilities for thermometer calibration by comparison method were assessed using high-precision industrial platinum resistance thermometers (IPRT). It was found in the performance assessment that out of 31 laboratories who participated, 28 laboratories resulted magnitude of En number less than 1 at every calibration points they submitted results in the range from 50 to $500^{\circ}C$. The results of about 75% of the laboratories showed the difference from the assigned values less than 1/10 of the tolerance level of the class B IPRT. This indicates that the participating calibration laboratories performed with satisfactory level that was enough to calibrate IPRTs to significant precision. The sensors used in this work were manufactured and chosen by the criteria of long-term instability less than 4 mK and hysteresis less than 8 mK in the temperature range used in this work. Furthermore, the change in the resistance of the sensors in the calibration temperature range were less than the uncertainty of the calibration, 25 mK (k=2).

Review of Contraindications for Oncology Acupuncture (암 환자의 침치료 금기증에 대한 고찰)

  • Bang, Sun-Hwi;Yoo, Hwa-Seung;Lee, Yeon-Weol;Cho, Chong-Kwan
    • Journal of Korean Traditional Oncology
    • /
    • v.16 no.2
    • /
    • pp.9-17
    • /
    • 2011
  • Objectives : Contradictions for Oncology acupuncture were searched and reviewed to establish fundamentals for the appropriate contraindication guideline. Methods : In order to search contraindications for oncology acupuncture, domestic journals, books and online database of Pubmed were searched using the terms, cancer, tumor, acupuncture, safety, contraindications and guideline were below. Results : We found 7 papers and 1 book by the above methods. We reviewed and suggested the contraindications. Contraindications for oncology acupuncture are neutropenia (absolute neutrophil count : ANC less than $500/mm^3$), thrombocytopenia (platelets less than $50,000/mm^3$), anticoagulant use, spinal instability, tumour nodule, lymphedema, prosthesis, intracranial deficits, confused patients, significant arrhythmia, patient refusal to treatment, severe neurotic patients and intracardiac defribillator. Contraindications for using semi-permanent needles are neutropenia (ANC less than $500/mm^3$), splenectomy, valvular heart disease, B, C hepatitis and keloids. Conclusions : Acupuncture for cancer patients pose significant risks but these guidelines are proposed in the hopes of providing certain boundaries in practicing oncology acupuncture. A more systematic and rigorous research is needed to establish a more reliable oncology acupuncture guidelines.

Cervico-Thoracic Intradural Extramedullary Lipoma

  • Jun, Young-Hoon;Kim, Se-Hoon;Kim, Sang-Dae;Lim, Dong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.316-319
    • /
    • 2005
  • A 42-year-old female was admitted with an 11-month history of progressive spastic paraparesis and ataxic gait. Magnetic resonance imaging showed intraspinal space occupying lesion compressing the spinal cord posteriorly, located from C5 to T2 with iso to high signal intensity at T2-weighted images and high signal intensity at T1-weighted images. The patient underwent surgery for decompression of the affected spinal cord because of the progressive neurological deficit. At surgery, the lesion was intradural extramedullary lipoma composed with mature adipose tissue. Partial tumor removal to decompress the neural structures and laminoplasty to avoid postoperative instability and deformity were performed. Postoperatively, she demonstrated improvement in paraparesis and was able to walk without assistance. Though attempts to decrease the size of or even to totally remove a lipoma are not required to achieve satisfactory results and carry considerable risks of surgical morbidity, a careful and limited decompression of the affected spinal cord through a partial removal of the tumor and laminoplasty could result in a significant neurological improvement.

Grain Refinement and Microstructural Instability of an AZ31 Mg Alloy by Severe Plastic Deformation Using ECA Pressing (ECAP 강가공에 의한 마그네슘 AZ31합금의 결정립 미세화 및 미세조직 불안정성)

  • Kim, H.K.;Chung, K.;Hyun, C.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.3
    • /
    • pp.139-145
    • /
    • 2004
  • Equal channel angular pressing (ECAP) technique had been adapted to the Mg alloy (AZ31) for achieving effective grain refinement through severe deformation. The average grain size of $2.5{\mu}m$ could be obtained after 4 passes. The stability of the ECAPed structure at elevated temperatures was examined by annealing the ECAPed materials over a wide range of temperature between 473 and 748 K. The average activation energy, Q, for static grain growth of 1, 2 and 3 passes was 33.7 kJ/mole (=0.25QL, activation for lattice diffusion). The abnormally low Q value in the lower temperature range may indicate that grain growth occurs in the unrecrystallized microstructure where non-equilibrium grain boundaries containing a large number of extrinsic dislocations exist. The yield stresses of the ECAPed alloys decreased whereas the elongations increased after the ECAP process. These results should be related to the modification of texture for easier slip on basal plane.

Effects of opening distance on liquid-gas spray of pintle injector under atmospheric condition (핀틀 인젝터의 개도가 액체-기체 상압 분무에 미치는 영향)

  • Yu, Kijeong;Son, Min;Koo, Jaye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.7
    • /
    • pp.585-592
    • /
    • 2015
  • Effects of opening distance on liquid-gas spray of pintle injector were experimentally investigated under atmospheric condition by using water and air as simulants of propellants. Discharge coefficients($C_d$) and mass flow rates were calculated with various injection conditions; 0.1 bar - 1.0 bar for water pressures and 0.2 mm - 1.0 mm for the pintle opening distances. Spray angles were measured from the spray images that were obtained by a shadowgraphy method. When opening distance is 0.2 mm, liquid sheet is not formed properly and it show non-uniform spray. than it can result in combustion instability. it has a weak correlation between the momentum flux ratio and the spray angle, while it has a strong correlation between the momentum ratio and spray angle. Finally the spray angles reduced exponentially when the momentum ratio increased and the spray angles converged to about 40 degrees.

Detection of Gelation in Ultra-high Temperature Treated Milks During Storage (초고온 멸균유의 저장중 겔 형성의 추적)

  • Park, In-Duck;Hong, Youn-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.404-406
    • /
    • 1993
  • In order to detect the gelation of ultrahigh temperature (UHT) treated market milks during storage at 20+1C, the free amino groups were quantified with 2,4,6-trinitrobenzene sulfonic acid, and the measurement of pH values and the alcohol test were monthly carried out. The average tree amino groups were $0.94{\sim}1.11{\mu}M$ at 1 month, $1.95{\sim}2.17{\mu}M\;at\;5{\sim}6$ month and $4.95{\sim}6.36{\mu}M$ at 12 month. The pH values at the same time as above were $6.72,\;6.49{\sim}6.55\;and\;6.14{\sim}6.16$, respectively. The alcohol test showed positive results at $5{\sim}6$ month, which could indicate the casein instability and beginning of gelation. These results suggest that the gelation of UHT market milks could he predicted through checking some chemical parameters weekly and be helpful for quality control.

  • PDF