• Title/Summary/Keyword: C.T image analysis

Search Result 101, Processing Time 0.027 seconds

Simulation of Energy Resolution of Time of Flight System for Measuring Positron-annihilation induced Auger Electrons (양전자 소멸 Auger 전자 에너지 측정을 위한 Time of Flight의 분해도 향상에 관한 이론적 연구)

  • Kim, J.H.;Yang, T.K.;Lee, C.Y.;Lee, B.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.311-316
    • /
    • 2008
  • Since the presence of the chemical impurities and defect at surfaces and interfaces greatly influence the properties of various semiconductor devices, an unambiguous chemical characterization of the metal and semiconductor surfaces become more important in the view of the miniaturization of the devices toward nano scale. Among the various conventional surface characterization tools, Electron-induced Auger Electron Spectroscopy (EAES), X-ray Photoelectron Spectroscopy (XPS) and Secondary Electron Ion Mass Spectroscopy (SIMS) are being used for the identification of the surface chemical impurities. Recently, a novel surface characterizaion technique, Positron-annihilation induced Auger Electron Spectroscopy (PAES) is introduced to provide a unique method for the analysis of the elemental composition of the top-most atomic layer. In PAES, monoenergetic positron of a few eV are implanted to the surface under study and these positrons become thermalized near the surface. A fraction of the thermalized positron trapped at the surface state annihilate with the neighboring core-level electrons, creating core-hole excitations, which initiate the Auger process with the emission of Auger electrons almost simultaneously with the emission of annihilating gamma-rays. The energy of electrons is generally determined by employing ExB energy selector, which shows a poor resolution of $6{\sim}10eV$. In this paper, time-of-flight system is employed to measure the electrons energy with an enhanced energy resolution. The experimental result is compared with simulation results in the case of both linear (with retarding tube) and reflected TOF systems.

Quantitative Assessment using SNR and CNR in Cerebrovascular Diseases : Focusing on FRE-MRA, CTA Imaging Method (뇌혈관 질환에서 신호대 잡음비와 대조도대 잡음비를 이용한 정량적평가 : FRE-MRA, CTA 영상기법중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.493-500
    • /
    • 2017
  • In this study, data analysis has been conducted by INFINITT program to analyze the effect of signal to noise ratio(SNR) and contrast to noise ratio(CNR) of flow related enhancement(FRE) and computed tomography Angiography(CTA) on cerebrovascular diseases for qualitative evaluations. Based on the cerebrovascular image results achieved from 63 patients (January to April, 2017, at C University Hospital), we have selected 19 patients that performed both FRE-MRA and CTA. From the 19 patients, 2 were excluded due to artifacts from movements in the cerebrovascular image results. For the analysis conditions, we have set the 5 part (anterior cerebral artery, right and left Middle cerebral artery, right and left Posterior cerebral artery) as the interest area to evaluate the SNR and CNR, and the results were validated through Independence t Test. As a result, by averaging the SNR, and CNR values, the corresponding FRE-MRA achieved were: anterior cerebral artery ($1500.73{\pm}12.23/970.43{\pm}14.55$), right middle cerebral artery ($1470.16{\pm}11.46/919.44{\pm}13.29$), left middle cerebral artery ($1457.48{\pm}17.11/903.96{\pm}14.53$), right posterior cerebral artery ($1385.83{\pm}16.52/852.11{\pm}14.58$), left posterior cerebral artery ($1318.52{\pm}13.49/756.21{\pm}10.88$). by averaging the SNR, and CNR values, the corresponding CTA achieved were: anterior cerebral artery ($159.95{\pm}12.23/123.36{\pm}11.78$), right middle cerebral artery ($236.66{\pm}17.52/202.37{\pm}15.20$), left middle cerebral artery ($224.85{\pm}13.45/193.14{\pm}11.88$), right posterior cerebral artery ($183.65{\pm}13.47/151.44{\pm}11.48$), left posterior cerebral artery ($177.7{\pm}16.72/144.71{\pm}11.43$) (p < 0.05). In conclusion, MRA had high SNR and CNR value regardless of the cerebral infarction or cerebral hemorrhage observed in the 5 part of the brain. Although FRE-MRA consumed longer time, it proved to have less side effect of contrast media when compared to the CTA.

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF

Analysis of Health Functional Foods Advertisements Effects according to the Delivery Tool for Efficacy Information and Consumers' Attitudes (기능성 정보 전달 방법 및 소비자 태도에 따른 건강기능식품 광고 효과 분석)

  • Lee, Yeonkyung;Kim, Ji Yeon;Kwon, Oran;Hwang, In-Kyeong
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.6
    • /
    • pp.835-848
    • /
    • 2016
  • The purpose of this study was to find efficient and customized tools for delivering the benefit of health functional foods (HFFs). Delivery tools which could influence the impact of advertising were images, explanations of ingredients, diagrams of health benefit, patents, and comments from authority. Six advertisements were developed using these tools: "A": relevant image + explanation of ingredients + scientific diagram of efficacy; "B": relevant image + explanation of ingredients; "C": relevant image; "D": irrelevant image; "E": irrelevant image + explanation of ingredient + patent; "F": irrelevant image + explanation of ingredient + comments from authority. To analyze the consumer perceptions on HFFs and advertisement effects, 300 respondents were requested to answer a questionnaire comprising of the following questions: 5 questions of attitudes (necessity of HFFs, trust in HFFs, gathering information, watching advertisements and trust in advertisement claims) and 6 questions on the 6 developed advertisements (attention, understanding, sufficiency of information, sympathy, trust, and purchase). Scoring was done as per the 5 Likert scale. There was a higher proportion of females and the elderly, as compared to males and youngsters. The overall consumer attitudes were positive. Explanation of ingredients, scientific diagram of health benefit, patents and expert comments were helpful factors in increasing the advertisement evaluation by consumer, but the images were not. Advertisement evaluation of consumer did not differ with gender and age. However, differences were observed between some of the consumer attitudes (necessity of HFFs, trust in HFFs, gathering information and trust in advertisements claim) and advertisement evaluations (attention, understanding, sympathy and purchase). Our results indicate that for consumers utilizing the HFFs, advertisements with concrete tools such as diagrams, patent, and expert comments are more helpful. However, for consumers who do not have interest in HFFs, the scientific information was irrelevant. We believe that to maximize the effect of health information in advertisements, consumers should be segmented, and customized tools for each segment needs to be developed.

Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model

  • Kim, So-Yeun;Lee, So-Hyoun;Cho, Seong-Keun;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • PURPOSE. The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero$^{TM}$ digital impression system. MATERIALS AND METHODS. The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group). The reference tooth and experimental models were scanned using a 3 shape convince$^{TM}$ scan system. Each GM and PM image was superimposed on the registered reference model (RM) and 2D images were obtained. The discrepancies of the points registered on the superimposed images were measured and defined as GM-RM group and PM-RM group. Statistical analysis was performed using a Student's T-test (${\alpha}=0.05$). RESULTS. A comparison of the absolute value of the discrepancy revealed a significant difference between the two groups only at the occlusal surface. The GM group showed a smaller mean discrepancy than the PM group. Significant differences in the GM-RM group and PM-RM group were observed in the margins (point a and f), mesial mid-axial wall (point b) and occlusal surfaces (point c and d). CONCLUSION. Under the conditions examined, the digitally fabricated polyurethane model showed a tendency for a reduced size in the margin than the reference tooth. The conventional gypsum model showed a smaller discrepancy on the occlusal surface than the polyurethane model.

A Study on Citizen Perceptions of the Gwangyang Steel and Iron Company: focus on CFI (광양제철소에 대한 지역 시민들의 기업이미지 분석: CFI를 이용하여)

  • Kim, Chang-Gon;Kim, Myung-Soo
    • Journal of Distribution Science
    • /
    • v.11 no.1
    • /
    • pp.35-44
    • /
    • 2013
  • Purpose - This study aims to (a) analyze local citizens' perception of a local company, the Gwangyang Steel and Iron Company (GSIC); (b) compare the perception toward the local company with that of national citizens' perceptions towards many other unspecified companies, which were surveyed biannually by The Korea Chamber of Commerce and Industry (KCCI); and (c) analyze how such companies evaluate perceptions towards them, in relation to citizens' socioeconomic position, such as their education status. Research design, data, methodology - The data were collected using a questionnaire, which was given to a sample of local citizens in cities. To test the hypotheses, factor analyses, a t-test, and an ANOVA were conducted. The total number of respondents was 1798. The data gathered from the respondents of the sample were analyzed using SPSS Win 19.0 software. Perception towards the company was evaluated on the corporate favorite index (CFI). The CFI index shows how positive citizens feel towards a company. It is calculated using five leading factors, consisting of the following: contribution to the economy, productivity, international competitiveness, social contribution, and ethical management. The higher the level of positive feelings exhibited, the closer the index will come to 100. Results - As a result of the analysis, the CFI index towards the GSIC stood at 67.3. The CFI index towards the company is 16.5 points higher than that of the index towards the many other unspecified companies, which were surveyed by the bi-annual KCCI study in the first half of 2011. The other five indexes stood as follows: contribution to the economy, productivity, social contribution, and ethical management was 69.2, 71.2, 64.6, and 58.6, respectively. These indexes are 18.3, 4.6, 27.6, and 35.6, respectively, higher than those found by the KCCI study. However, international competitiveness is 73.0 (9.8 points lower than that of the KCCI study). This survey thus shows that the CFI of the local citizens towards the global company GSIC is very high when compared with the CFI index towards the many other unspecified companies that was determined by the KCCI survey. Conclusions - This survey shows that local citizens have high expectations of economic activity, increasing working opportunities, and regional cooperation projects from the local company, GSIC. In addition, the CFI index towards GSIC evaluates results depending on the respondent's relationship with the company, and their educational status. Respondents, whose family or relatives were working as employees of GSIC, have relatively positive perceptions of GSIC, and respondents with a relatively higher educational status also share positive perceptions. Local citizens expect the profit-making of the company to operate in accordance with management activities, and at the same time, they expect that the wealth generated by the company will return to wider society.

  • PDF

Effect of Cosmetics Contained Isotonic Water Mimicked Body Fluid on Cell Activities and Skin (생체 모사수 화장품이 세포 활성과 피부에 미치는 효과)

  • Park, Sun Young;Lee, Sung Hoon;Kim, Eun Joo;Choi, So Woong;Kim, Ji Young;Cho, Seong A;Cho, Jun Cheol;Lee, Hae Kwang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.2
    • /
    • pp.195-201
    • /
    • 2014
  • Body fluid has been studied for diverse fields like Ringer's solutions, artificial joint fluids, cell growth culture media because it plays a crucial role in controlling body temperature and acts as a solvent for diverse metabolite processes in the body and delivery media of mineral, energy source, hormone, signal and drug from and to cell via blood or lymphatic vessel by osmotic pressure or active uptake. Stratum corneum containing extracellular lipids and NMF (natural moisturizing factor) absorbs atmospheric water residing outside of cells and utilize it to hydrate inside of their own. This process is related to skin barrier function. In this study, we conducted the cell viability test with Cell Bio Fluid $Sync^{TM}$, which mimicks body fluids including amino acids, peptides, and monosaccharides to strengthen skin barrier, and the clinical skin improvement test with cosmetics containing Cell Bio Fluid $Sync^{TM}$. In the cell viability test, HaCaT cell was treated with PBS for 3 hours, followed by the treatment of a cell culture medium (DMEM) and isotonic solution (PBS) and Cell Bio Fluid $Sync^{TM}$ for 3 hours each. Then, MTT assay and image analysis were conducted. In the clinical skin improvement test, twenty-one healthy women participated. Participants applied cosmetics containing Cell Bio Fluid $Sync^{TM}$ on their face for a week and evaluated the skin hydration, skin roughness, brightness and evenness. All measurements were conducted after they washed off their face and took a rest under the constant temperature ($22{\pm}2^{\circ}C$) and constant humidity conditions ($50{\pm}5%$) for 20 minutes. All the data were analyzed by SPSS (version 21) software program. Results showed that Cell Bio Fluid $Sync^{TM}$ improved both the cell viability and in vivo skin conditions such as skin hydration, roughness, brightness and evenness.

Clinical Implication of Cyclooxygenase-2 Expression for Rectal Cancer Patients with Lymph Node Involvement (림프절 전이를 동반한 직장암 환자들에서 Cyclooxygenase-2 발현의 임상적 의미)

  • Lee, Hyung-Sik;Choi, Young-Min;Hur, Won-Joo;Kim, Su-Jin;Kim, Dae-Cheol;Roh, Mee-Sook;Hong, Young-Seoub;Park, Ki-Jae
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.210-217
    • /
    • 2009
  • Purpose: To assess the influence of cyclooxygenase-2 (COX-2) expression on the survival of patients with a combination of rectal cancer and lymph node metastasis. Materials and Methods: The study included rectal cancer patients treated by radical surgery and postoperative radiotherapy at the Dong-A university hospital from 1998 to 2004. A retrospective analysis was performed on a subset of patients that also had lymph node metastasis. After excluding eight of 86 patients, due to missing tissue samples in three, malignant melanoma in one, treatment of gastric cancer around one year before diagnosis in one, detection of lung cancer after one year of diagnosis in one, liver metastasis in one, and refusal of radiotherapy after 720 cGy in one, 78 patients were analyzed. The immunohistochemistry for COX-2 was conducted with an autostainer (BenchMark; Ventana, Tucson, AZ, USA). An image analyzer (TissueMine; Bioimagene, Cupertino, CA, USA) was used for analysis after scanning (ScanScope; Aperio, Vista, CA, USA). A survival analysis was performed using the Kaplan Meier method and significance was evaluated using the log rank test. Results: COX-2 was stained positively in 62 patients (79.5%) and negatively in 16 (20.5%). A total of 6 (7.7%), 15 (19.2%), and 41 (52.6%) patients were of grades 1, 2, and 3, respectively for COX-2 expression. No correlation was found between being positive of COX-2 patient characteristics, which include age (<60-year old vs. $\geq$60), sex, operation methods (abdominoperineal resection vs. lower anterior resection), degrees of differentiation, tumor size (<5 cm vs. $\geq$5 cm), T stages, N stages, and stages (IIIa, IIIb, IIIc). The 5-year overall and 5-year disease free survival rates for the entire patient population were 57.0% and 51.6%, respectively. The 5-year overall survival rates for the COX-2 positive and negative patients were 53.0% and 72.9%, respectively (p=0.146). Further, the 5-year disease free survival rates for the COX-2 positive and negative patients were 46.3% and 72.7%, respectively (p=0.118). The 5-year overall survival rates were significantly different (p<0.05) for the degree of differentiation, N stage, and stage, whereas the 5-year disease free survival rates were significant for N stage and stage. Conclusion: Being positive for and the degree of COX-2 expression did not have a significant influence on the survival of rectal cancer patients with lymph node metastasis. However, N stage and stage did significantly influence the rateof survival. Further analysis of a greater sample size is necessary for the verification of the effect of COX-2 expression on the survival of rectal cancer patients with lymph node involvement.

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF