• Title/Summary/Keyword: C-plate

Search Result 2,751, Processing Time 0.028 seconds

Mutagenic Activity of Smoke Flavoring Processed from Oak and Apple Wood on Manufacturing Temperature (굴참나무와 사과나무로부터 제조한 훈연액의 제조온도에 따른 돌연변이원성에 관한 연구)

  • 강희곤;이경호;홍희선;박상진;김창한
    • Food Science of Animal Resources
    • /
    • v.18 no.3
    • /
    • pp.203-208
    • /
    • 1998
  • The study was carried out to screen mutagenicity of smoking materials for the determination of optimum smoking temperature for meat products. Wood materials employed for smoking were oak and apple trees. Temperatures of the generator for manufacturing of smoke flavoring were set to 250$^{\circ}C$, 400$^{\circ}C$ and 500$^{\circ}C$, respectively. Mutagenic activities of smoke flavoring were assayed according to Ames test using Salmonella typhimurium TA98 and TA 100. In oak wood smoke flavoring, Salmonella typhimurium TA98 without S-9 mix showed strong mutagenic activities at the concentration of 6$\mu\textrm{g}$/plate(250$^{\circ}C$), 4$\mu\textrm{g}$/plate(400$^{circ}C$) and 6$\mu\textrm{g}$/plate(500$^{\circ}C$). Salmonella typhimurium TA100 with S-9 mix showed strong mutagenic activities at the concentration of 10$\mu\textrm{g}$/plate(250$^{\circ}C$), 20$\mu\textrm{g}$/plate(400$^{\circ}C$) and 10$\mu\textrm{g}$/plate(500$^{\circ}C$). Salmonella typhimurium TA98 with S-9 mix showed strong mutagenic activities at the concentration of 30$\mu\textrm{g}$/plate(250$^{\circ}C$), 40$\mu\textrm{g}$/plate(400$^{\circ}C$) and 20$\mu\textrm{g}$/plate(500$^{\circ}C$). Salmonella typhimurium TA100 with S-9 mix showed strong mutagenic activities at the concentration of 30$\mu\textrm{g}$/plate(250$^{\circ}C$), 50$\mu\textrm{g}$/plate(400$^{\circ}C$) and 20$\mu\textrm{g}$/plate(500$^{\circ}C$). Salmonella typhimurium TA100 without S-9 mix showed strong mutagenic activities at the concentration of 10$\mu\textrm{g}$/plate(250$^{\circ}C$), 20$\mu\textrm{g}$/plate(400$^{\circ}C$) and 20$\mu\textrm{g}$/plate(500$^{\circ}C$). Salmonella typhimurium TA98 with S-9 mix showed strong mutagenic activities at the concentration of 30$\mu\textrm{g}$/plate(250$^{\circ}C$), 40$\mu\textrm{g}$/plate(400$^{\circ}C$) and30$\mu\textrm{g}$/plate(500$^{\circ}C$). Salmonella typhimurium TA100 with S-9 mix showed strong mutagenic activities at the concentrations 30$\mu\textrm{g}$/plate(500$^{\circ}C$). Salmonella typhimurium TA100 with S-9 mix showed strong mutagenic activities at the concentration of 30$\mu\textrm{g}$/plate(250$^{\circ}C$), 20$\mu\textrm{g}$/plate(400$^{\circ}C$) and 30$\mu\textrm{g}$/plate(500$^{\circ}C$). From these results, it could be concluded that optimum smoking temperature for meat products should be set below 400$^{\circ}C$, that the compounds like benzo[a]pyrene etc. contain a variety of mutagenic potentials, which could be generated at the higher smoking temperature.

  • PDF

Developments of Parking Control System Using Color Information and Fuzzy C-menas Algorithm (컬러 정보와 퍼지 C-means 알고리즘을 이용한 주차관리시스템 개발)

  • 김광백;윤홍원;노영욱
    • Journal of Intelligence and Information Systems
    • /
    • v.8 no.1
    • /
    • pp.87-101
    • /
    • 2002
  • In this paper, we proposes the car plate recognition and describe the parking control system using the proposed car plate recognition algorithm. The car plate recognition system using color information and fuzzy c-means algorithm consists of the extraction part of a car plate from a car image and the recognition part of characters in the extracted car plate. This paper eliminates green noise from car image using the mode smoothing and extract plate region using green and white information of RGB color. The codes of extracted plate region is extracted by histogram based approach method and is recognized by fuzzy c-means algorithm. For experimental, we tested 80 car images. We shows that the proposed extraction method is better than that from the color information of RGB and HSI, respectively. So, we can know that the proposed car plate recognition method using fuzzy c-means algorithm was very efficient. We develop the parking control system using the proposed car plate recognition method, which showed performance improvement by the experimental results.

  • PDF

A Study on the Development of a Ultra-Strength Precast Concrete Bearing Concrete Bearing Plate (초고강도 ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$) P.C Bearing Plate 개발에 관한 연구)

  • 소현창;정병욱;김재우;문성규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.643-648
    • /
    • 1997
  • P.C Bearing Plate method, corresponding to the existing steel plate build-up method, is developed by the very first in domestic and is applied to the foundation in the HYUNDAI building at Kang-Nam. P. C Bearing Plate produced in ourself P.C plant can stand against vertical load of 7,000ton obtaining allowable force of soil. It is possible to minmize cost expediting, do site assembling and omit unnecessary excavation work by plant prefabrication of foundation member. The purpose of this paper is to study the optimum mixing design of Ultra-high strength concrete ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$), crack control through measuring the heat of hydration, mock up test for the optimum curing method. As mentioned above, developing the Ultra-high strength Precast Concrete Bearing Plate set up successfully in the site foundation work of the HYUNDAI Building at Kang-Nam.

  • PDF

Ductility of Column-Slab eoint in R/C Flat Plate System (플랫 플레이트 구조의 기둥.슬래브 접합부 연성에 관한 연구)

  • 김형기;박복만
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.113-119
    • /
    • 2000
  • The R/C flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problems in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab joint. Recently, the flat plate system accompanied with shear walls to resist the lateral loads is applied to high-rise buidings. Although the flat plate system is not considered in design as part of the lateral load-resisting system, it is required that this system keeps the ductile behavior for the lateral displacement of the building. However, it is unclear whether the column-slab joint possesses ductility enough to survive the lateral deformation. The objective of this paper is to investigate the major parameters that influence the ductility of R/C flat plate system by examining the existing experiments on column-slab joint. The effects of gravity load and shear reinforcement on the ductility of the flat plate system are presented.

Static strength of collar-plate reinforced tubular T-joints under axial loading

  • Shao, Yong-Bo
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.323-342
    • /
    • 2016
  • To study the effect of collar-plate reinforcement on the static strength of tubular T-joints under axial loading, fundamental research work is carried out from both experimental test and finite element (FE) simulation. Through experimental tests on 7 collar-plate reinforced and 7 corresponding un-reinforced tubular T-joints under axial loading, the reinforcing efficiency is investigated. Thereafter, the static strengths of the above 14 models are analyzed by using FE method, and it is found that the numerical results agree reasonably well with the experimental data to prove the accuracy of the presented FE model. Additionally, a parametric study is conducted to analyze the effect of some geometrical parameters, i.e., the brace-to-chord diameter ratio ${\beta}$, the chord diameter-to-chord wall thickness ratio $2{\gamma}$, collar-plate thickness to chord wall thickness ratio ${\tau}_c$, and collar-plate length to brace diameter ratio $l_c/d_1$, on the static strength of a tubular T-joint. The parametric study shows that the static strength can be greatly improved by increasing the collar-plate thickness to chord wall thickness ratio ${\tau}_c$ and the collar-plate length to brace diameter ratio $l_c/d_1$. Based on the numerical results, parametric equations are obtained from curving fitting technique to estimate the static strength of a tubular T-joint with collar-plate reinforcement under axial loading, and the accuracy of these equations is also evaluated from error analysis.

An Experimental Study on the Strength and Deformation of Reinforced Concrete Columns Strengthed with Epoxy-Bonded Steel Plate (강판접착으로 보강된 철근콘크리트 기둥의 내력 및 변형에 관한 실험적 연구)

  • Kim, Jin-Bai;Lee, Si-Woo;Jang, Hwa-Kyun;Cho, Chul-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.1
    • /
    • pp.147-155
    • /
    • 1999
  • The purpose of this study is to investigate the strength and ductility of reinforced concrete columns subject to axial load experimentally for several variables of reinforcements and propose foundational research date for reinforcement design of column. In the test a total of eleven specimens, which are all $20{\times}20{\times}60cm$ in size and differently reinforced with steel plate, has been used. The main variables of reinforcement considered in the test are the width of steel plate, the thickness of steel plate. Based on the test results, the effect of the main variables on the strength and ductility of reinforced concrete column have been scrutinized. The strength of reinforced concrete columns are that C-2 series on strengthed with 2mm thickness steel plate are smaller than C-4 series on strengthed with 4mm steel plate. Thick steel plate of reinforced expected utilizer than the other on strength increase and specimens to be large width steel plate of each system are the utiltzer on strength increase. Ductility of C-0 specimen is 1.60, C-2 series is 2.38, C-4 series 2.63 Compare efficiency of ductility increase with each specimens, in narrow width condition (2cm, 4cm) C-2 series is more efficiency, in wide width condition (8cm, 10cm) C-4 series is more efficiency.

  • PDF

Structural analysis and wearability evaluation of a vehicle's swash plate A/C compressor (자동차용 에어컨 컴프레서의 구조해석과 내마모성 평가)

  • Kim, Jin-Woo;Ha, Sun-Ho;Kim, Sang-Jin;Kim, Chang-Uk;Song, Jung-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.109-115
    • /
    • 2013
  • In this study, a variable swash plate compressor has been used in a vehicle to improve its fuel efficiency. To manufacture the swash plate, either SCM 435 or UNS C67300 was used. The effects of using different materials for the structural reliability of compressor have been investigated. Static analysis was carried out on swash plate A/C compressor by using commercial software ANSYS 13.0v. The results showed that the Max. stress occurred on the swash plate made of UNS C67300 was lower than that made of SCM435, which indicated that UNS C67300 is more suitable for producing the safe swash plate.

An Analysis of the Reinforced Concrete Circular Ring Sector Plates with Arbitrary Boundary Conditions (I) - Part I Effects of open-angle - (임의의 경계조건을 갖는 철근 콘크리트 선형판의 해석 -제1보 개각의 영향)

  • 조진구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.2
    • /
    • pp.94-103
    • /
    • 1991
  • This study was carried out to investigate the engineering characteristics of the R.C circular ring sector plate with various boundary conditions and then to propose a rational and paraical method for application of finite element method to R.C structures. The stiffness matrix of the circular ring sector plate was obtained by using the multi-base coordinate system in which the base-coordinate systems were constructed for each nodal point of the quadrilateral element in order to reflect the complicated boundary conditions conveniently and correctly. The R.C element stiffness matrix was constructed by adding the stiffness coefficients of the steel-bar element into the plate bending element stiffness matrix. Herein, the steel-bar element was treated as the common beam element. Using the above method, the effects of steel-bar can be considered without increasing of the numbers of element and nodal points.

  • PDF

Treatment for Distal Humeral Fractures by Modified Anatomical Y-Plate (변형된 Y형 해부학적 금속판을 이용한 상완골 원위부 골절의 치료)

  • Moon Eun Sun;Park Jae Hyung;Lee Young Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.51-57
    • /
    • 1998
  • Comminuted fracture of the distal end of the humerus in adults is very rare and difficult to treat. In operative treatment, an implant which can achieve accurate anatoraical reduction and rigid fixation is needed. But the pre­existing Y -shaped plate had wide and thick limbs and some problems in fixation for most distal humeral fractures. So we devised a modified plate which is more narrow and th1n and has a different hole distance and wing length (long lateral wing). The aim of the study was to evaluate the clinical result of this modified anatomical Y -plate. From 1991 to 1997, we treated 23 cases of distal humeral fractures using modified anatomical plate and the results were as follows. 1. Fracture type in 18 patients(78%) was C-type(C1,C2,C3) which were intraarticular and mostly displaced or comminuted. 2. Bony union was obtained in 22 patients(96%) through rigid fixation and observed radiologically at 3.5 months(2-6months) on the average. 3. In 23 patients, 19 patients(82%) showed satisfactory results after 34 months(6-73months) follow-up. So if the modified anatomical Y-plate is used in the treatment of distal humeral fracture, a satisfactory result can be obtained through a more accurate, easy, and rigid fixation than preexisting plate.

  • PDF

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF