• Title/Summary/Keyword: C-correction

Search Result 712, Processing Time 0.032 seconds

Distortion Correction of Boundary Lines in a Tunnel Image Captured by Fisheye Lens (어안렌즈 터널영상의 경계선 왜곡 보정)

  • Kim, Gi-Hong;Jeong, Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.55-63
    • /
    • 2011
  • Having a wide angle of view, a fisheye lens is useful for obtaining images of the inside wall of a tunnel. A circular fisheye tunnel image can be transformed into a familiar rectangular image by applying the concept of cylindrical projection. This projection transformation causes several types of distortions in the projected image. This paper discusses the distortion on the boundary lines between smoothly curved wall and flat ground. We analyzed the cause of this boundary distortion, developed transformation model, and derived a correction formular. A distortion correction software programmed in Visual C++ applied to projected image. Consequently, boundary-corrected image could be obtained. Research into other distortions of projected image will helpful in obtaining tunnel image that resembles real tunnel from fisheye tunnel image.

Direct Calculation of TRS-398 Quality Correction Factors for High Energy Photons (고에너지 광자선에 대한 TRS-398 선질보정인자의 직접 계산)

  • Shin Kyo-Chul;Oh Young-Kee;Kim Jeung-Kee;Kim Jhin-Kee;Kim Ki-Hwan;Jeong Dong-Hyeok
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.54-60
    • /
    • 2006
  • In order to apply the TRS-398 dosimetry protocol developed by IAEA we directly calculated the quality correction factors for high energy photons. The calculations were peformed for seven commercial cylindrical chambers (A12, IC70, N23333, N30001, N30006, NE2571, PR06C/G). In comparison with quality correction factors given by TRS-398 our results were in good agreement within ${\pm}0.3%$ (maximum ${\pm}0.3%$) for all chambers and photon qualities.

  • PDF

1.6 Tb/s (160x10 Gb/s) WDM Transmission over 2,000 km of Single Mode Fiber (1.6 Tb/s (160x10 Gb/s) WDM 신호의 단일 모드 광섬유 2,000 km 전송)

  • 한진수;장순혁;이현재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.712-718
    • /
    • 2004
  • We report 1.6 Tb/s (160${\times}$10 Gb/s) WDM transmission over 2,000 km of single mode fiber using distributed hybrid(distributed Raman amplifier+Erbium-doped fiber amplifier) optical amplifiers. After transmission over 2,000 km of single mode fiber, average optical signal to noise ratios of C/L-band were 20.5 dB, 21.9 dB, respectively. The minimum Q-factors of each band were 14.65 dB (BER=5.8e-8) in C-band, 13.75 dB (BER=5.0e-7) in L-band without forward error correction. We performed 1.6 Tb/s error-free transmission over 2,000 km of single mode fiber using Reed-Solomon (255, 239) forward error correction code.

Analysis of Lead in Blood using SR(self-reversal) and $D_2$ Arc Background Correction Methods (SR 바탕보정법과 $D_2$ 바탕보정법에 의한 혈액 중 Pb 분석)

  • Lee, Seokki;Kim, Poongzag
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.427-434
    • /
    • 1994
  • For the analysis of the relatively volatile lead in blood by GFAAS(graphite furnace atomic absorption spectrophotometer), one can not raise the ashing temperature beyond certain degree due to the elevation of the baseline. Previous investigations showed that background is stabilized when the ashing temperature is raised to $700^{\circ}C$ using a matrix modifier. In this study, same result was obtained at the ashing temperature of around $550^{\circ}C$ even when the matrix modifier is not used and only Triton X-100 is used as a diluent, on an instrument which is equipped with both temperature and current controller(Shimadzu, AA-6501S) and thus the temperature control is fast and accurate. Background correction methods of $D_2$ arc and SR(self reversal) were reviewed. The results show that the absorbance is higher for the $D_2$ arc method, but the background correction is higher for the SR method.

  • PDF

Effect of Ambient Temperature on Bovine Erythrocyte Sedimentation Rate as Measured by Angled Capillary Method (경사모세관법에 의한 우의 적혈구침강 속도에 미치는 환경온도의 영향)

  • Kim Kyeong-Jin;Lee Bang-Whan
    • Journal of Veterinary Clinics
    • /
    • v.4 no.1
    • /
    • pp.395-401
    • /
    • 1987
  • In this study, the effect of ambient temperature on the 45$^{\circ}$micro ESR/hr of cattle blood were observed, and a correction chart for correcting observed values at any ambient temperature to standard values at 20$^{\circ}C$ was plotted. Besides, the effect of storage temperature of blood on the 45$^{\circ}$micro ESR/hr was surveyed. The results were as follows: 1. The values of the 45$^{\circ}$micro ESR/hr were increased as the ambient temperature were elevated(P<0.01), and lower the value of PCV, higher the effect of temperature on the 45$^{\circ}$micro ESR/hr was observed(P<0.01). 2. Regression of values of 45$^{\circ}$micro ESR to ambient temperature in all the group of different level of blood PCV showed linear regression with the highly significant coefficient of correlation. With the results, correction chart was drawn as in Fig. 1. 3. In the purpose to verify the reliability of correction chart, observed values of 45$^{\circ}$micro ESR/hr in field(out door) were corrected to values at 20$^{\circ}C$ by the correction chart(Fig. 1), comparing with the observed values at 20$^{\circ}C$ of standard temperature. No significant differences were found between two groups mentioned above. 4. In the study on the effect of storage temperature of the blood on the 45$^{\circ}$micro ESR/hr, group of storage temperature at 5$^{\circ}C$ showed statistically no significant differences untill 24 hours in contrast with standard control group.

  • PDF

Marine Reservoir Corrections $({\Delta}R)$ for Southern Coastal Waters of Korea (한국 남부 연안해역의 탄소동위원소연대 보정)

  • KONG, GEE SOO;LEE, CHI WON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.10 no.2
    • /
    • pp.124-128
    • /
    • 2005
  • Marine reservoir correction $({\Delta}R)$ values are measured using two species of mollusk tests collected by NFRDI in 1942 before nuclear bomb testing to convert the radiocarbon age to calendar age in Korean coastal waters more accurately. The ${\Delta}R$ values are calculated to be $-117\pm45\;^{14}C\;yr$ in the southwestern coast of Korea and $-160\pm35\;^{14}C\;yr$ in southeastern coast. These values are similar to those in Chinese coast of the Yellow Sea $(-81\pm60\~-178\pm50\;^{14}C\;yr$, indicating that regional reservoir $^{14}C$ ages of these areas are lower than mean global reservoir $^{14}C$ age. The lower ${\Delta}R$ values in these areas are presumed to be mainly caused by influence of fresh-water inflow. The ${\Delta}R$ values presented In this study enhance the accuracy in converting radiocarbon age to calendar age in Korean coastal waters.

Uncertainty in Regional Climate Change Impact Assessment using Bias-Correction Technique for Future Climate Scenarios (미래 기상 시나리오에 대한 편의 보정 방법에 따른 지역 기후변화 영향 평가의 불확실성)

  • Hwang, Syewoon;Her, Young Gu;Chang, Seungwoo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.4
    • /
    • pp.95-106
    • /
    • 2013
  • It is now generally known that dynamical climate modeling outputs include systematic biases in reproducing the properties of atmospheric variables such as, preciptation and temerature. There is thus, general consensus among the researchers about the need of bias-correction process prior to using climate model results especially for hydrologic applications. Among the number of bias-correction methods, distribution (e.g., cumulative distribution fuction, CDF) mapping based approach has been evaluated as one of the skillful techniques. This study investigates the uncertainty of using various CDF mapping-based methods for bias-correciton in assessing regional climate change Impacts. Two different dynamicailly-downscaled Global Circulation Model results (CCSM and GFDL under ARES4 A2 scenario) using Regional Spectial Model for retrospective peiod (1969-2000) and future period (2039-2069) were collected over the west central Florida. Total 12 possible methods (i.e., 3 for developing distribution by each of 4 for estimating biases in future projections) were examined and the variations among the results using different methods were evaluated in various ways. The results for daily temperature showed that while mean and standard deviation of Tmax and Tmin has relatively small variation among the bias-correction methods, monthly maximum values showed as significant variation (~2'C) as the mean differences between the retrospective simulations and future projections. The accuracy of raw preciptiation predictions was much worse than temerature and bias-corrected results appreared to be more significantly influenced by the methodologies. Furthermore the uncertainty of bias-correction was found to be relevant to the performance of climate model (i.e., CCSM results which showed relatively worse accuracy showed larger variation among the bias-correction methods). Concludingly bias-correction methodology is an important sourse of uncertainty among other processes that may be required for cliamte change impact assessment. This study underscores the need to carefully select a bias-correction method and that the approach for any given analysis should depend on the research question being asked.

RBR Based Network Configuration Fault Management Algorithms using Agent Collaboration (에이전트들 간의 협력을 통한 RBR 기반의 네트워크 구성 장애 관리 알고리즘)

  • Jo, Gwang-Jong;An, Seong-Jin;Jeong, Jin-Uk
    • The KIPS Transactions:PartC
    • /
    • v.9C no.4
    • /
    • pp.497-504
    • /
    • 2002
  • This paper proposes fault diagnosis and correction algorithms using agent collaboration, and a management model for managing network configuration faults. This management model is composed of three processes-fault detection, fault diagnosis and fault correction. Each process, based on RBR, operates on using rules which are consisted in Rule-based Knowledge Database. Proposed algorithm selves the complex fault problem that a system could not work out by itself, using agent collaboration. And the algorithm does efficiently diagnose and correct network configuration faults in abnormal network states.

Statistical Atmospheric Correction of Lake Surface Temperature from Landsat Thermal Images

  • Han, Hyang-Sun;Lee, Hoon-Yol
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.418-421
    • /
    • 2005
  • In this study, we analyzed surface temperature of lakes in the Han River system, using Landsat-5 and -7 time-series images. Surface temperature was extracted using NASA equation and compared with in situ 10m-depth temperature in Lake Soyang and surface temperature on five other dam lakes downstream. The 24 images out of 29 showed standard deviation of temperature difference less than $2^{\circ}C$, to which a novel statistical atmospheric correction could be applied. The correlation coefficients were 0.950 at Lake Soyang and 0.979-0.997 at the other lakes after atmospheric correction.

  • PDF

Correction Coeffecient for Tensile Adhesive Strength of the Bridge Decks Waterproofing Systems with Different Temperature Conditions (온도조건에 따른 교면방수재의 인장접착강도 보정계수에 관한 실험적 연구)

  • Lee, Byung-Duck;Yun, Byung-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.794-797
    • /
    • 2004
  • In this study, tensile adhesive strength(TAS) test was carreid out for evaluated the effects of temperature conditions (-20, -10, 0, 5, 10, 20, 30, $40^{\circ}C$) on the tensile adhesive characteristics about 4 type waterproofing membranes which were commercially used in bridge decks. And, failure appeariences of waterproofing systems in each temperature after TAS test were observed the sawing surfaces of waterproofing systems for whether or not damaged of waterproofing membranes. Also, correction coefficient of TAS with temperature were calculated using 4 type waterproofing membrane. It could be shown that the higher TAS and shear adhesive strength, the lower temperature, regardless of the type of waterproofing membrane. Temperature sensibility of TAS was especially remarkable in epoxy membrane. Failure type was occurred the ductile failure in $30^{\circ}C\;and\;40^{\circ}C$. From these results, it was shown that if ambient temperature above $30^{\circ}C$ maintains for a long time, waterproofing membrane will be deformed by softening. Otherwise, waterproofing membrane in temperature below $20^{\circ}C$ shown that occurred the brittle failure. From the results of visual observation of cutting surface for specimen, the thin waterproofing membranes shown indented by hot aggregate of the asphalt mixtures. Therefore, it could be known that the specification of waterproofing membrane thickness is necessary by waterproofing membrane type. As temperature change varied with pavement depth, the interface temperature was more important than ambient temperature in TAS test. Now, TAS test results were limited only in $-10^{\circ}C\;and\;20^{\circ}C$ temperature, but correction coefficient of TAS by ambient temperature could be used as a solution to deal with this problem.

  • PDF