• Title/Summary/Keyword: C-4

Search Result 70,455, Processing Time 0.079 seconds

A Study on the Corrosion Properties and Microstructure of the Nitrocarburized and Oxidized Low Carbon Steel according to the Treatment Atmospheres (저탄소강의 질화침탄과 산화처리시 분위기 변화에 따른 조직 및 부식특성에 관한 연구)

  • Shin, P.W.;Lee, K.H.;Nam, K.S.;Park, Y.M.;Jo, H.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.2
    • /
    • pp.87-93
    • /
    • 2004
  • Nitrocarburizing was carried out with various $CH_4$ gas composition with 4 torr gas pressure at $570^{\circ}C$ for 3 hours and post oxidation was carried out with 100% $O_2$ gas atmosphere with 4 torr at different temperatures for various time. In the case of plasma nitrocarburizing, It is that the ratio of ${\varepsilon}-Fe_{2-3}$(N, C) and ${\gamma}^{\prime}-Fe_4$(C, N), which comprise the compound layer phase, depend on concentrations of $N_2$ gas and $CH_4$ such that when the concentration of $N_2$ and $CH_4$ increased, the ratio of ${\gamma}^{\prime}-Fe_4$(C, N) decreased, but the ratio of ${\varepsilon}-Fe_{2-3}$(N, C) increased. The thickness of compound layer consistently increased as gas concentration increased regardless of $N_2$ and $CH_4$ expect when the concentration of $CH_4$ was 3.5 volume%, it decreased insignificantly. When oxidizing for 15min in the temperature range of $460{\sim}570{^\circ}C$, the study found small amount of $Fe_3O_4$ at the temperature of $460{^\circ}C$ and also found that amounts of $Fe_2O_3$. and $Fe_3O_4$ on the surface and amount of ${\gamma}^{\prime}-Fe_4$(C, N) in the compound layer increased as the increased over $460^{\circ}C$, but the thickness of the compound layer decreased. Corrosion resistance was influenced by oxidation times and temperature.

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

Effects on the Thermal Changes of Hap-Kok(LI4) and Chun-Choo(ST25) Following Acupuncture on Hap-Kok(LI4) in Man (합곡(合谷)(LI4) 자침(刺鍼)이 합곡(合谷)(LI4)과 천추(天樞)(ST25) 영역(領域) 온도변화(溫度變化)에 미치는 영향(影響))

  • Sohn, In-Chul;Kim, Dong-Min;Kim, Jae-Hyo;Kim, Kyung-Sik;Lee, Ho-Seop
    • The Journal of Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.66-88
    • /
    • 1998
  • This study was performed from March to September 1997 on 95 healthy students to observe the effects of acupuncture at Hap-kok (LI4) according to the meridian and qi-xue(氣血) phenomenon of oriental medicine's theory. Skin temperature on the Hap-kok (LI4) and Chun-Choo (ST25) were measured by D. 1. T. I. (Digital Infrared Thermograph Imaging) before acupuncture stimulation and 1min, 10 min after acupuncture stimulation. 1. In healthy students, the left and right mean temperature of LI4 and ST25 was $29.04\;^{\circ}C,\;29.12\;^{\cir}C\;and\;30.29\;^{\circ}C,\;30.22\;^{\circ}C$ respectively. 2. In control group, the time dependent changes for 10 min of LI4 and ST25 were $-0.32\;^{\circ}C,\;-0.36\;^{\circ}C\;and\;-0.5\;^{\circ}C,\;-0.46\;^{\circ}C$ respectively, however, the thermal differences of both sides LI4 and ST25 were not changed for 10 min. 3. In acupuncture stimulation of both sides LI4, the time dependent changes of ST25 were $-0.13\;^{\circ}C,\;-0.06\;^{\circ}C$, and the thermal differences of both sides ST25 were reduced, but not changed significantly. In acupuncture stimulation of right side LI4, the time dependent changes of LI4 were $-0.1\;^{\circ}C,\;-0.32\;^{\circ}C$ respectively, and the thermal differences of both sides LI4 were increased more than control, but not significantly. Also, that of ST25 were changed by $-0.69\;^{\circ}C,\;-0.63\;^{\circ}C$ respectively, but not significantly. 4. In acupuncture stimulation group, it was classified following the thermal differences of both sides LI4 and ST25, and the effects of acupuncture were observed by changes of classification. The acupuncture of both sides LI4 results in temperature of the left side ST25 to be high after acupuncture. The acupuncture of right side LI4 results in increased ratio of the left side higher than right LI4. The above results indicates that D. I. T. I. was a useful method to observe follow-up the effects and changes by acupuncture stimulation on objective evaluation of phenomenon for the meridian system. Thus, acupuncture on LI4 affects to thermal changes of ST25 and LI4, but exact examination of thermal changes on ST25 will have to be.

  • PDF

Fabrication of Polycrystalline SiC Doubly Clamped Beam Micro Resonators and Their Characteristics (양단이 고정된 빔형 다결정 3C-SiC 마이크로 공진기의 제작과 그 특성)

  • Chung, Gwiy-Sang;Lee, Tae-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.4
    • /
    • pp.303-306
    • /
    • 2009
  • This paper describes the characteristics of polycrystalline 3C-SiC doubly clamped beam micro resonators. The polycrystalline 3C-SiC doubly clamped beam resonators with $60{\sim}100{\mu}m$ lengths, $10{\mu}m$ width, and $0.4{\mu}m$ thickness were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonant frequency was measured by a laser vibrometer in vacuum at room temperature. For the $60{\sim}100{\mu}m$ long cantilevers, the fundamental frequency appeared at $373.4{\sim}908.1\;kHz$. The resonant frequencies of doubly clamped beam with lengths were higher than simulated results because of tensile stress. Therefore, polycrystalline 3C-SiC doubly clamped beam micro resonators are suitable for RF MEMS devices and bio/chemical sensor applications.

Thermal Rearrangement of 1,1-Disubstituted 2-Vinylcyclopropanes to 4,4-Disubstituted Cyclopentenes (두 치환체를 가진 비닐시클로프로판의 시클로펜텐으로의 열적자리 옮김반응)

  • Iwhan Cho;Kwang-Duk Ahn
    • Journal of the Korean Chemical Society
    • /
    • v.22 no.3
    • /
    • pp.158-163
    • /
    • 1978
  • The four 1,1-disubstituted 2-vinylcyclopropanes, 1,1-diphenyl-2-vinylcyclopropane (1a), 1,1-dicyano-2-vinylcyclopropane(1b), ethyl 1-cyano-2-vinylcyclopropanecarboxylate(1c), and diethyl 2-vinylcyclopropane-1,1-dicarboxylate(1d) rearranged below $300{\circ}C$ to the corresponding 4,4-disubstituted cyclopentenes, 4,4-diphenylcyclopentene(2a), 3-cyclopentene-1,1-dicarboxylate(2d). Diphenpyl derivative 1a rearranged almost quantitatively to 4,4-diphenylcyclopentene(2a) at the temperature of $250{\circ}C$. Although dicyano derivative 1b in solution underwent the thermal rearrangement at rather low temperature of $170{\circ}C$, the other vinylcyclopropanes, 1c and 1d, in solution rearranged thermally above $220{\circ}C$. In the thermal reaction of 1b, 1c, and 1d considerable amounts of polymers 3 were also produced. Also detected product was the ring-opened diene, ethyl 2-cyano-2,4-hexadienoate(4), in case of the pyrolysis of 1c. The observed facile rearrangement of disubstituted vinylcyclopropanes was explained by the radical stabilization effect of substituents on the diradical intermediates 5.

  • PDF

C4I Maintenance Priority Decision using fault analysis methods (결함분석 기법을 활용한 C4I체계 유지보수 관리 우선순위 선정)

  • Kim, Kiwang;Kang, DongSu
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.07a
    • /
    • pp.25-28
    • /
    • 2017
  • 네트워크 중심전에서 C4I체계의 안정적 운용을 통한 전장에서의 정보우위 달성을 위해 체계의 신뢰성 확보가 필요하여 각 군 C4I체계는 외주 용역업체를 통해 유지보수를 수행 중에 있다. 유지보수는 C4I체계의 수명 주기 중 가장 오랜 기간을 차지하고 있으며 결함 데이터 등의 실증적인 자료를 확보할 수 있는 기간이다. 따라서 유지보수 기간 중 수집한 결함 데이터를 결함분석기법을 통해 분석(치명도, 발생빈도)하고, 주요기능별 활용도를 이용하여 C4I체계 유지보수 관리 우선순위 선정기법을 제안한다. 이 후 제안 기법을 해군 C4I체계의 군적용 사례연구를 통해 유지보수 관리 우선순위를 선정함으로써 유지보수의 제한된 자원(예산, 인력, 시간 등)을 효율적으로 활용하기 위한 판단의 근거로 사용이 가능함을 보인다. 뿐만 아니라 체계화된 결함분석과정을 통해 축적된 자료를 활용하여 유지보수의 연속성 보장과 향후 성능개량사업간 시스템 분석의 참고자료로 활용함에 따라 궁극적으로 C4I체계의 신뢰성을 향상시킬 수 있다.

  • PDF

Deep UV 마이크로 리소그라피를 위한 새로운 4-반사경 광학계에 관한 수차해석

  • 김종태;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1993
  • A design of four-mirror optical system with reduction magnification 5X for deep UV ($\lambda$=248 nm of KrF excimer laser) submicron lithography is presented. Initially by using the paraxial quantities, the domain of solution for $t=d_1+d_2+d_3$<0 (d;: distance between the mirror $c_i$ and $c_{i+1}$ is found for the system which is free from the four off-axial Seidel first order aberrations that are coma, astigmatism, field curvature, and distortion. The solution with $d_5$=2.95 (normalized with respect to $c_i$= -1) is choosen and the aspherization is carried out to the spherical mirror surfaces ($c_3$ and $c_4$ in order to reduce the axial and residual off-axial higher order aberrations. The numerical aperture of the final system is as large as 0.4, which gives Rayleigh resolution of 0.38 $\mu\textrm{m}$.

  • PDF

A study on ESD Protection circuit based on 4H-SiC MOSFET (4H-SiC MOSFET기반 ESD보호회로에 관한 연구)

  • Seo, Jeong-Ju;Do, Kyoung-Il;Seo, Jeong-Ju;Kwon, Sang-Wook;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1202-1205
    • /
    • 2018
  • In this paper, we proposed ggNMOS based on 4H-SiC material and analyzed its electrical characteristics. 4H-SiC is a wide band-gap meterial, which is superior in area contrast and high voltage characteristics to Si material, and is attracting attention in the power semiconductor field. The proposed device has high robustness and strong snapback characteristics. The process consisted of SiC process and electrical characteristics were analyzed by TLP measurement equipment.

Review on fabrication of graphitic carbon nitride based efficient nanocomposites for photodegradation of aqueous phase organic pollutants

  • Sudhaik, Anita;Raizada, Pankaj;Shandilya, Pooja;Jeong, Dae-Yong;Lim, Ji-Ho;Singh, Pardeep
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.28-51
    • /
    • 2018
  • Graphitic carbon nitride ($g-C_3N_4$) as a fascinating visible light active semiconductor photocatalyst has medium band gap, non-toxic nature, stable chemical structure and high thermal stability. Recently, intensive researches are focused on photocatalytic activity of $g-C_3N_4$ for wastewater treatment. This review demonstrates latest progress in fabrication of graphitic carbon nitride $C_3N_4$ incorporated nanocomposite to explore photocatalytic ability for water purification. The $g-C_3N_4$-based nanocomposites were categorized as $g-C_3N_4$ metal-free nanocomposite, noble metals/$g-C_3N_4$ heterojunction, non-metal doped $g-C_3N_4$, transition and post transition metal based $g-C_3N_4$ nanocomposite. Apart from fabrication methods, we emphasized on elaborating the mechanism of activity enhancement during photocatalytic process.

Crystal Structure Analysis of 3-(4-ethylphenyl)-3H-chromeno[4,3-c]isoxazole-3a(4H)-carbonitrile

  • Malathy, P.;Ganapathy, Jagadeesan;Srinivasan, J.;Manickam, Bakthadoss
    • Journal of Integrative Natural Science
    • /
    • v.8 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • The crystal structure of the potential active 3-(4-ethylphenyl)-3H-chromeno[4,3-c]isoxazole-3a(4H)-carbonitrile ($C_{19}H_{16}N_2O_2$) has been determined from single crystal X-ray diffraction data. In the title compound crystallizes in the monoclinic space group $P2_1/c$ with unit cell dimension a=6.6869 (8) ${\AA}$, b=15.8326 (19) ${\AA}$ and c= 15.237 (2) ${\AA}$ [${\alpha}=90^{\circ}$, ${\beta}=100.663^{\circ}$ and ${\gamma}=90^{\circ}$]. In the structure chromene, isoxazole and carboxylate are almost coplanar each other. All geometrical parameters revelled that chromene ring of pyran ring adopt sofa conformation. The crystal packing is stabilized by intermolecular C-H...N and C-H...O hydrogen bond interaction.