• Title/Summary/Keyword: C-계획

Search Result 1,341, Processing Time 0.069 seconds

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

The Historical Research of the Future Housing Planning Concept(1) -Focused on the Future Housing Planning Concept proposed from the 19C to the beginning of the 20C- (미래주거 계획개념의 전개과정에 대한 역사적 고찰(1) -19세기-20세기 전반기에 제시된 미래주거 계획개념을 중심으로-)

  • 김미경;박영순
    • Korean Institute of Interior Design Journal
    • /
    • no.14
    • /
    • pp.90-98
    • /
    • 1998
  • At the threshold of the 21st century People have been exploring the future of each field. Accordingly In the area of housing the increase in income level and high-technology development facilitated full scale research on the future housing. The purpose of this research is to try to set up a systematic theory on the future housing by investigating theoretical backgrounds of the future housing and development of the future housing planning concept, A document research method was used to analyze the development of the future housing planning concept of three periods from its origin in the 19th century to present : the burgeoning period growing period and maturing period. In particulary this research examines development of the future housing planning concept from the 19th century in which future housing planning concept was emerged to the early part of the 20th century: the burgeoning period. The future housing planning concepts of this period are analyzed as follows ; In order to solve the social problems arising in the process of the Industrial Revolution, the concept such as ; "ideal city", "high rise apartment housing" and "industrialized housing" was formulated. housing" was formulated.ated.

  • PDF

Review of Acceptance Sampling Plans for Parts Per Million Fraction of Defectives (PPM 부적합품률의 샘풀링 검사 계획의 고찰)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.4
    • /
    • pp.137-142
    • /
    • 2007
  • This paper is to introduce attribute acceptance sampling plan based on statistical inference of binomial proportions such as PPM or PPB. In addition, this paper presents three variable sampling acceptance sampling plans based on $C_{pm},\;C_{pmk}$, and Taguchi's loss function. Producers are able to consider as not only external vendors but also internal customers.

Study on The Generation Expansion Planning Considering Emission Trading and LOLP (배출권거래와 공급신뢰도(LOLP)를 고려한 설비계획 방법론에 관한 연구)

  • Shin, Hye-Kyeong;Chung, Gu-Hyung;Hong, Hee-Jung;Han, Seoc-Man;Kang, Dong-Ju;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.214-216
    • /
    • 2007
  • Post 2012 기후변화협약 체제의 토래 및 강화되는 기후변화협약으로 인해 우리나라의 온실가스 의무감축이 확실하게 예견되고 있는 현 시점에서 우리나라의 온실가스 감축이행을 위한 대응책의 필요성이 증가하고 있다. 특히 발전부문은 우리나라의 온실가스 배출의 약 30%를 차지하고 있으며, 경제성장에 따라 온실가스 배출량이 빠른 속도로 증가하고 있으므로 Post 2012 기후변화협약 체제의 대응책이 보다 필요하다. 본 연구에서는 향후 발전부문에 온실가스 감축의무가 부담될 것을 고려하여 온실가스 배출량 제약 및 배출권거래제를 고려한 설비계획을 도출하고자 한다. 현재 우리나라의 전원 개발계획에서 사용되고 있는 전산모형(WASP, POWERSYM 등)은 온실가스 배출량 제약 및 배출권거래제를 고려하지 못하므로 MEFISET 모형을 이용하여 이를 고려하고자 한다. 그러나 MEFISET 모형은 설비예비력 제약조건을 통해 공급신뢰도를 만족하고 있다. 이러한 설비계획 결과는 공급신뢰도 기준 을 만족시키기 위해 과도한 설비계획 결과를 도출한다. 따라서 본 연구에서는 이를 보완하기 위해 Visual C를 통해 구현한 LOLP 프로그램을 통해 공급신뢰도 기준을 만족시키기 위한 적정 설비예비력을 추정하고자 한다.

  • PDF