• Title/Summary/Keyword: C Generation

Search Result 3,484, Processing Time 0.037 seconds

Chinese Prosody Generation Based on C-ToBI Representation for Text-to-Speech (음성합성을 위한 C-ToBI기반의 중국어 운율 경계와 F0 contour 생성)

  • Kim, Seung-Won;Zheng, Yu;Lee, Gary-Geunbae;Kim, Byeong-Chang
    • MALSORI
    • /
    • no.53
    • /
    • pp.75-92
    • /
    • 2005
  • Prosody Generation Based on C-ToBI Representation for Text-to-SpeechSeungwon Kim, Yu Zheng, Gary Geunbae Lee, Byeongchang KimProsody modeling is critical in developing text-to-speech (TTS) systems where speech synthesis is used to automatically generate natural speech. In this paper, we present a prosody generation architecture based on Chinese Tone and Break Index (C-ToBI) representation. ToBI is a multi-tier representation system based on linguistic knowledge to transcribe events in an utterance. The TTS system which adopts ToBI as an intermediate representation is known to exhibit higher flexibility, modularity and domain/task portability compared with the direct prosody generation TTS systems. However, the cost of corpus preparation is very expensive for practical-level performance because the ToBI labeled corpus has been manually constructed by many prosody experts and normally requires a large amount of data for accurate statistical prosody modeling. This paper proposes a new method which transcribes the C-ToBI labels automatically in Chinese speech. We model Chinese prosody generation as a classification problem and apply conditional Maximum Entropy (ME) classification to this problem. We empirically verify the usefulness of various natural language and phonology features to make well-integrated features for ME framework.

  • PDF

Implementation of an Over-Current Relaying Algorithm with TMS320C32 (TMS320C32를 이용한 한시 과전류 계전기의 구현)

  • Yoo, Sung-Rok;Yoon, Byung-Wook;Park, Byung-Woo;Choi, Chang-Yung;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2193_2194
    • /
    • 2009
  • A digital over current relay(OCR) is realized by using TMS320C32 microprocessor. Fourier Transform is used to obtain the phasor of a current signal and a 2nd low pass filter is adopted to prevent aliasing error. H/W test shows almost same results with those of the S/W test. It could be possible that confirm simularity between H/W and S/W test in this paper.

  • PDF

An Experimental Study on the Small Power Generation of Temperature difference using the Freon-22 as Working Fluid (프레온-22를 작동유체로 사용한 소용량 온도차 발전에 관한 실험적 연구)

  • Jhoun, C.S.;Shin, I.H.;Huh, C.S.
    • Solar Energy
    • /
    • v.8 no.2
    • /
    • pp.26-38
    • /
    • 1988
  • If proper design and selection of the working fluid are made the power generation system of temperature difference could achieve more efficient results than others. This paper is to analysis the production of its power generation due to several parameters. Making the power generation system, the characteristics of power output are investigated to obtain its basic data for design. This results of this experiment are as follows. 1. The most proper working fluid in the system is Freon-22 having high stability and difference between the outlet pressure, $P_E$ of evaporator and outlet pressure, $P_c$ of Condenser. 2. With the increase of temperature difference between evaporator and condenser, the output in the system increases linearly. 3. The generation efficiency is largely dependent on the type or form of propeller, nozzle and optimum design of heat exchanger.

  • PDF

Implementation of an Over-Current Relaying Algorithm Using 80C196KC (80C196KC를 이용한 과전류 계전 알고리즘 구현)

  • Kim, Hyung-Kyu;Lee, Bong-Hyun;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.495-496
    • /
    • 2007
  • An Over Current Relayng algorithm using 80c196kc micro processor was realized in this paper. This OCR Algorithm was verified with simulated fault signal. The fault signal was made by EMTP and realized by DOBLE to compare H/W test with S/W test. This simulations showed similar result between H/W and S/W test.

  • PDF

바이러스 외피단백질 유전자로 형질전환된 연초 식물체의 TMV 저항성 발현 및 유전자 안정성

  • 박성원;이기원;이청호;이영기;강신웅;최순용
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.1
    • /
    • pp.77-81
    • /
    • 1999
  • Tobacco plants(Nicotiana tabacum cv. NC82) transformed with TMV CP cDNA were self-fertilized until 8th generation (R$_{8}$), and the transgenic plants from 6th to 8th generation were analized for their resistance to tobacco mosaic virus(TMV) and stability of the gene expression. The 6th generation of the plants(R$_{6}$) showed high resistance(81-91 %) to TMV at eight weeks after artificial inoculation with the virus. The transgenic cell line 601 was the most prominant in the expression of resistance. 98 % of the plants showed no symptom without any agronomic phynotepe variation when they were inoculated with the virus in a experimental field. However, 2% of the plants were revealed as delay type of symptom with mild mosaic on a few leaves. The viral resistance in greenhouse tests of the 7th generation (R$_{7}$) was 54-64%, and the number of delay type plants were increased than that of 6th generation plants. In the 8th generation, 81 % of the plants was complete resistant to the virus. The TMV CP cDNA of the transgenic plants of each generation was also confirmed by genomic PCR, and there was no systemic viral multiplication in the resistant plants. It suggests that the viral resistance and gene expression of the transgenic plants might be stable through the generations.ons.s.

  • PDF

A Study on V-C Interoperability Test and Methodology of V-C Interoperation Analysis for Next Generation Maritime Warfighting Experimentation Systems (차세대 해상전투실험체계 구현을 위한 V-C 연동실험 및 연동분석 방법론 연구)

  • Shin, Hyunsoo;Kim, Junghoon;Choi, Bongwan;Yim, Dongsoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.84-94
    • /
    • 2016
  • The warfighting experimentation is the most important for the weapon acquisition process because the warfighting experimentation shall support the operation effectiveness as well as acquisition logicality. Therefore, ROK Navy is starting to set up the next generation warfighting experimentation systems. According to literature studies, there have been many studies regarding the interoperability of Simulators(Virtual) and Exercising models(Constructive), but not for studies regarding interoperability between Simulators(Virtual) and Analysis models(Constructive) that is the core component of next generation maritime warfighting experimentation systems. This study is dealing with the V-C(Analysis model) interoperability test and methodology of interoperation analysis. The purpose of the study is to provide the new analysis methodology through V-C(Analysis model) interoperation, which can be applied for the concept of operations(CONOPS) of next generation maritime warfighting experimentation systems. In addition to that, the study validates the suggested analysis methodology by the case study of a naval operation.

INTERACTION STUDIES OF CERAMIC VACUUM PLASMA SPRAYING FOR THE MELTING CRUCIBLE MATERIALS

  • Kim, Jong Hwan;Kim, Hyung Tae;Woo, Yoon Myung;Kim, Ki Hwan;Lee, Chan Bock;Fielding, R.S.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.683-688
    • /
    • 2013
  • Candidate coating materials for re-usable metallic nuclear fuel crucibles, TaC, TiC, ZrC, $ZrO_2$, and $Y_2O_3$, were plasmasprayed onto a niobium substrate. The microstructure of the plasma-sprayed coatings and thermal cycling behavior were characterized, and U-Zr melt interaction studies were carried out. The TaC and $Y_2O_3$ coating layers had a uniform thickness, and high density with only a few small closed pores showing good consolidation, while the ZrC, TiC, and $ZrO_2$ coatings were not well consolidated with a considerable amount of porosity. Thermal cycling tests showed that the adhesion of the TiC, ZrC, and $ZrO_2$ coating layers with niobium was relatively weak compared to the TaC and $Y_2O_3$ coatings. The TaC and $Y_2O_3$ coatings had better cycling characteristics with no interconnected cracks. In the interaction studies, ZrC and $ZrO_2$ coated rods showed significant degradations after exposure to U-10 wt.% Zr melt at $1600^{\circ}C$ for 15 min., but TaC, TiC, and $Y_2O_3$ coatings showed good compatibility with U-Zr melt.

DC Micro-Grid Operational Analysis with a Detailed Simulation Model for Distributed Generation

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon;Jeong, Yu-Seok;Yang, Hyo-Sik;Cha, Han-Ju
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.350-359
    • /
    • 2011
  • This paper describes the operational analysis results of a DC micro-grid using a detailed model of distributed generation. A detailed model of wind power generation, photo-voltaic generation and fuel cell generation was implemented with an userdefined model created with PSCAD/EMTDC software and coded in C-language. The operational analysis was carried out using PSCAD/EMTDC software, in which the power circuit is implemented by a built-in model and the controller is modeled by an user-defined model that is also coded in C-language. Various simulation results confirm that a DC micro-grid can operate without any problems in both the grid-tied mode and in the islanded mode. The operational analysis results confirm that the DC micro-grid makes it feasible to provide power to the load stably. It can also be utilized to develop an actual system design.

The Relationship between Domain Switching and Acoustic Emission in (Pb,La)$TiO_3$ Ferroelectric Ceramacs ((Pb,La)$TiO_3$ 강유전체 세라믹에서 분역반전과 Acoustic Emission의 관계)

  • 최동구;최시경
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.6
    • /
    • pp.672-678
    • /
    • 1996
  • The relationship between domain switching and acoustic emission (AE) during poling was investigated using the tetragonal ferroelectric ceramics with composition of (Pb,La)TiO3+0.01MnO2 The amount of AE generation during poling increased with increasing dc electric field and raising temperature. It was confirmed that the change of the amount of AE generation with poling condition resulted from the difference of the amount of 90$^{\circ}$ domain switching and total amount of AE generation for 10 minutes was approximately proportional to the amount of 90$^{\circ}$domain switching. The A generations of two specimens which have different tetragonality rations(c/s rations) 15 at% and 24at% La-doped were also investigated. The sample with c/a ratio of 1.012 where 90$^{\circ}$ domains are dominate had larger amount of AE generation and 90$^{\circ}$ domain switching compared with the sample with c/a ratio of 1.004 where 180$^{\circ}$ domains are dominant.

  • PDF