• Title/Summary/Keyword: C형

Search Result 257, Processing Time 0.025 seconds

Precast Shear Wall Systems with C Type Connections (C형 접합부를 이용한 프리캐스트 전단벽 시스템에 관한 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.217-224
    • /
    • 2006
  • This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC wails require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.

  • PDF

Double Tension Band Osteosynthesis in Intra-articular Fractures of the Distal Humerus (AO type C) in Elderly Osteoporotic Patients (고령 환자의 상완골 원위부 AO-C형 골절에서 이중 강선 장력대 고정술)

  • Cheon, Sang Jin;Lee, Dong Ho;Goh, Tae Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the clinical result of intra-articular fractures of the distal humerus (AO type C) in elderly osteoporotic patients treated with double tension band osteosynthesis. Materials and Methods: From January 2006 to December 2010, 10 elderly osteoporotic patients(1 male, 9 females) with intra-articular fractures of the distal humerus (AO type C) were treated with double tension band osteosynthesis. The mean age of patients at the time of surgery was 74.6(66~84) years and the mean follow-up period was 39.2(20~74) months. The fracture union and complications were assessed and the functional result was evaluated by the rating system of Jupiter et al. and the Mayo elbow performance index. Results: Bone union was achieved in all patients with no secondary displacement. The mean time for union was 16.6(13~22) weeks. The average postoperative arc of elbow flexion was 119(100~140) degrees with a mean flexion contracture of 8.5(0~15) degrees. The recovery in two patients was rated as excellent, in 7 as good, and in 1 as fair in terms of the Mayo elbow performance index with average value of 82(70~90) points. Seven patients were rated as excellent, 1 as good, and 2 as fair in terms of the rating system of Jupiter et al. Changing tension band wiring was performed in one patient as skin irritation was noticed due to tension band knots. Heterotopic ossification developed in one patient but had no symptom. Conclusion: Double tension band osteosynthesis in intra-articular fractures of distal humerus (AO type C) in elderly osteoporotic patients can provide sufficient and secure stability to allow early rehabilitation.

STRESS DISTRIBUTION IN ESTHETIC ORTHODONTIC BRACKETS : AN ANALYSIS USING THE FINITE ELEMENT METHOD (유한요소 분석을 통한 심미적 교정 브라켓의 응력 및 구조분석에 관한 연구)

  • Lee, Won-You;An, Ju-Sam;Park, Young-Cheol;Park, Myeong-Kyun;Sohn, Hong-Bum;Jeong, Si-Dong
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.43-49
    • /
    • 1998
  • The aim of this study were to measure and compare the stress level on three type brackets and each other material (stainless steel, ceramic) with tipping and torquing forces by using the finite element analysis and to design biomechanically favorable brackets. For this study, three kinds of brackets were selected(A:Transcend-RMO, B:Signature-Unitek, C:PAW: plain archwire appliance-applied for a patent in Yonsei Udiversity). The slot size of bracket was 0.022inch and the size of archwire was 0.0175x0.025inch and taper shaped archwire was used in PAW. Loading force in tipping was 4.27N and torquing force was 32.858N applied by archwire torsion with 19.7degree and 11.3 degree in C type bracket. The conclusions were that (1) The finite element method proved to be a useful tool in the stress analysis of orthodontic bracket subjected to various forces. (2) With tipping, the stresses were concentrated at the gingival wall of the wire slot where it meets the mesial bracket surface and the incisal wall of the wire slot where it meets the distal bracket surface and with torquing, the stresses were concentrated at the junction of the gingival or incisal wall and base of the slot. (3) The maximum stress value was higher in torquing force than tipping force and therefore it is desirable to design on the basis of torquing force. (4) It was considered that the change in material might be affect on the diminish of stress value in the place of stess concentration. (5) The maximum stress value was highest on PAW bracket when the tipping and torquing force was applied and therefore it would be desirable to use mechanically favorable material on PAW bracket.

  • PDF

Clinical Features of Non-A, B, C Viral Hepatitis in Children (소아에서 발생한 비-A, B, C형 바이러스성 간염의 임상 고찰)

  • Son, Seung Kook;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2005
  • Purpose: Non-A, B, C viral hepatitis is the name given to the disease with clinical viral hepatitis, but in which serologic evidence of A, B, C hepatitis has not been found. Little is known about the etiology and clinical features of non-A, B, C viral hepatitis in children. Methods: A clinical analysis of 45 cases with non-A, B, C viral hepatitis who were admitted to the Department of Pediatrics, Pusan National University Hospital, from January 2001 to June 2004 was carried out retrospectively. Patients who were positive for HBsAg, anti-HAV and anti-HCV and had toxic, metabolic, autoimmune, or neonatal hepatitis were excluded in this study. Results: Among 45 cases of non-A, B, C viral hepatitis, the etiology was unknown in 26 (57.8%), CMV (cytomegalovirus) in 14 (31.1%), EBV (Epstein Barr virus) in 2 (4.4%), HSV (herpes simplex virus) in 2 (4.4%) and RV (rubella virus) in 1 (2.2%). Twenty seven out of 45 (60.0%) patients were under 1 year of age. Sixteen (33.3%) patients had no specific clinical symptoms and were diagnosed incidentally. On physical examination, twenty seven out of 45 patients (60.0%) had no abnormal findings. Forty three out of 45 patients (95.6%) showed classic clinical course of acute viral hepatitis, whereas fulminant hepatitis developed in two patients. Mean serum ALT (alanine aminotransferase) level was $448.7{\pm}771.9IU/L$. Serum ALT level was normalized in 31 out of 45 patients (81.6%) within 6 months and all patients within 18 months. Aplastic anemia was complicated in a case. Conclusion: Although most patients with non-A, B, C viral hepatitis showed a good prognosis, a careful follow-up would be necessary because some of them had a clinical course of chronic hepatitis, fulminant hepatitis and severe complication such as aplastic anemia.

  • PDF

An Experimental Study on Development of the Opening Apparatus for Oil Boom (오일펜스 전개장치 개발에 관한 실험적 연구)

  • Jang Duck-Jong;Na Sun-Chol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.45-54
    • /
    • 2006
  • The study was to review methods by which a ship can unfold and tow an oil boom by attaching the opening apparatus to an oil boom through experiments. The shape and dimension of the opening apparatus were designed with the measurement value of the towing tension load of the oil boom and the dimension of winch drum of the oil boom installed in the ship considered. For the field experiment to identify the performance of the opening apparatus, opening apparatuses were prepared to have the dimension of $3.0m^2$ and $6.0m^2$ which is 91% and 75% of the calculation value for type B and C respectively. As a result, T(kg), the value of tension in type B oil boom according to the towing speed(v) change when two ships are towed together were proved to be $T=920v^{1.1}\;and\;T=500v^{0.9}$ in case the distance is 100 m and 50 m. Based on the result, the dimension of the opening apparatus for type B and C oil boom was calculated as $3.3m^2$ and $8.0m^2$ respectively. When unfolding and towing by attaching the opening apparatus and 200 m of towing line at both ends of type B and type C oil boom, the maximum width of the opening apparatus was shown as 114 m and 95 m in average(width of opening/total length of oil boom: 33% and 57%) in the towing speed of 1.5 kt. It was evaluated that the opening apparatus could concentrate the spilled oil in a good performance. However as far as the increase rate of oil boom opening width according to the length of the towing line is debatable, the increase rate is remarkably reduced when it is lengthened from 100 m to 150 m and to 200 m although it showed extreme increase of 31% and 40% when the length of the towing line was changed from 50 m to 100 m. Therefore, it is inferred that the towing line should be maintained more or less 100 m to get good spread efficiency of the opening apparatus. Additionally, if the towing speed is faster than 1.5 kt, the opening width was narrowed because of the reduced spread efficiency and the shape of the oil boom can be unstable because of the partial sinking of the oil boom, run over waves, or flap of skirt. Thus the reasonable towing speed can be within 1.5 kt for the operation of the opening apparatus.

  • PDF

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Hepatitis C Virus Core Protein Activates p53 to Inhibit E6-associated Protein Expression via Promoter Hypermethylation (C형 간염바이러스 코어 단백질에 의한 p53 활성화와 프로모터 과메틸화를 통한 E6AP 발현 억제)

  • Kwak, Juri;Jang, Kyung Lib
    • Journal of Life Science
    • /
    • v.28 no.9
    • /
    • pp.1007-1015
    • /
    • 2018
  • The E6-associated protein (E6AP) is known to induce the ubiquitination and proteasomal degradation of HCV core protein and thereby directly impair capsid assembly, resulting in a decline in HCV replication. To counteract this anti-viral host defense system, HCV core protein has evolved a strategy to inhibit E6AP expression via DNA methylation. In the present study, we further explored the mechanism by which HCV core protein inhibits E6AP expression. HCV core protein upregulated both the protein levels and enzyme activities of DNA methyltransferase 1 (DNMT1), DNMT3a, and DNMT3b to inhibit E6AP expression via promoter hypermethylation in HepG2 cells but not in Hep3B cells, which do not express p53. Interestingly, p53 overexpression alone in Hep3B cells was sufficient to activate DNMTs in the absence of HCV core protein and thereby inhibit E6AP expression via promoter hypermethylation. In addition, upregulation of p53 was absolutely required for the HCV core protein to inhibit E6AP expression via promoter hypermethylation, as evidenced by both p53 knockdown and ectopic expression experiments. Accordingly, levels of the ubiquitinated forms of HCV core protein were lower in HepG2 cells than in Hep3B cells. Based on these observations, we conclude that HCV core protein evades ubiquitin-dependent proteasomal degradation in a p53-dependent manner.

Production of a Phospholipase C by Bacillus cereus and Its Characterization (Bacillus cereus에 의한 C형 인지질 분해효소의 생산과 특성 고찰)

  • 서국화;임용식;이종일
    • KSBB Journal
    • /
    • v.19 no.4
    • /
    • pp.250-256
    • /
    • 2004
  • In this work we have cultivated several B. cereus strains in a complex LB medium in order to study the production of phospholipase C (PLC), and among them B. cereus 318 showed the highest productivity of PLC. Some components, i.e., 5 g/L glucose, 5 g/L yeast extract, 5 g/L peptone, 0.5∼1.0 g/L K$_2$HPO$_4$, 0.02∼0.04 g/L ZnSO$_4$$.$7H$_2$O and 3 g/L NaHCO$_3$ were found to be optimal for the high production of PLC by B. cereus 318. Optimal culture temperature and pH were found to be 30$^{\circ}C$ and pH 7.5 for the PLC production, respectively. Optimum reaction temperature and pH of the PLC produced by B. cereus 11 and 318 were 45$^{\circ}C$ and pH 4.0, while they were 50$^{\circ}C$ and pH 7.0 for the PLC by B. cereus 559. The PLC produced by B. cereus was activated by Mn$\^$2+/, Co$\^$2+/ and dimethyl sulfoxide (DMSO), but its activity was inhibited by Cu$\^$2+/ and partially by glycerol, isopropanol and sodium dodecyl sulfate (SDS).

Secretory and Sensory Receptor Cells in the Sucker of Korean Octopus minor II (한국산 낙지(Octopus minor) 흡반(Sucker)내 분비 및 감각수용세포 II)

  • Chang, Nam-Sub
    • Applied Microscopy
    • /
    • v.30 no.3
    • /
    • pp.295-301
    • /
    • 2000
  • Five kinds of sensory cells, called A1-, A2-, B-, C-, and D-type cell, respectively, are observed in the epithelial tissue of suker's infundibulum of Cephalopoda, Octopus minor. The A1-type cells lie side by with the B-type cell in the epithelium of sucker's infundibulum. In the A1-type, the nucleus shapes irregularly and the karyolymph appears dark due to its high electron density. The cytoplasm is filled with many vacuoles of various sizes ($0.04\sim0.4{\mu}m$ in diameter), which move to the apical portion of the cell to be secreted via glycocalyx. The A2-type cells are mainly found at the basal portion of the epithelium. The shape of its nucleus is similar to that in the A1-type cell, and the cytoplasm, filiform or in reticular form, shows high electron density. The B-type cell contains an ovoid nucleus and the cytoplasm where lots of vacuoles which resemble the endoplasmic reticulum and electron-dense round granules of various sizes $(0.25\sim0.6{\mu}m)$ are found. The vacuoles and granules are secreted into the free surface via glycocalyx. The C- and D-type cells in simple or stratified layer are observed at the folded portion of the sucker's epithelium. The C-type cell contains a low electron-dense elliptical nucleus, while the D-type cell has an irregular nucleus where beterochromatin is well developed.

  • PDF

Streptococcal Toxic Shock Syndrome Occurred during Postoperative Radiotherapy in a Cancer Patient with Preexisting Lymphedema and Chronic Illness -Case Report- (수술 후 림프부종과 만성질환을 동반한 종양 환자에서 방사선치료 기간 동안 발생한 연쇄구균독소충격증후군 예)

  • Jang, Ji-Young;Oh, Yoon-Kyeong;Kim, Dong-Min
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.317-321
    • /
    • 2006
  • A case is reported of a man with malignant fibrous histiocytoma (MFH) in right thigh who developed streptococcal toxic shock syndrome (STSS) during postoperative radiotherapy. Before radiotherapy, a patient complained wax and wane lymphedema following wide excision of tumor mass which was confirmed as MFH. He took some nonsteroidal antiinflammatory drug (NSAID) for about one month. He suffered preexisting hepatitis C virus (HCV) infection, diabetes and well-controlled hypertension. The patient received conventional radiotherapy to right thigh with a total dose of 32.4 Gy at 1.8 Gy per day. At last radiotherapy fraction, cutaneous erythematous inflammation was suddenly developed at his affected thigh. At that time, he also complained of oliguria, fever and chills. The patient was consulted to internal medicine for adequate evaluation and management. The patient was diagnosed as suggested septic shock and admitted without delay. At admission, he showed hypotension, oliguria, constipation, abnormal renal and liver function. As a result of blood culture, Streptococcus pyogenes was detected. The patient was diagnosed to STSS. He was treated with adequate intravenous antibiotics and fluid support. STSS is one of oncologic emergencies and requires immediate medical intervention to prevent loss of life. In this patient, underlying HCV infection, postoperative lymphedema, prolonged NSAID medication, and radiotherapy may have been multiple precipitating factors of STSS.