• Title/Summary/Keyword: C/A code

Search Result 1,655, Processing Time 0.029 seconds

Development of an MCNP-Based Cone-Beam CT Simulator (MCNP 기반의 CBCT 전산모사 시스템 개발)

  • Lim, Chang-Hwy;Cho, Min-Kook;Han, Jong-Chul;Youn, Han-Bean;Yun, Seung-Man;Cheong, Min-Ho;Kim, Ho-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.351-359
    • /
    • 2009
  • We have developed a computer simulator fur cone-beam computed tomography (CBCT) based on the commercial Monte Carlo code, MCNP. All the functions to generate input files, run MCNP, convert output files to image data, reconstruct tomographs were realized in graphical user-interface form. The performance of the simulator was demonstrated by comparing with the experimental data. Although some discrepancies were observed due to the ignorance of the detailed physics in the simulation, such as scattered X-rays and noise in image sensors, the overall tendency was well agreed between the measured and simulated data. The developed simulator will be very useful for understanding the operation and the better design of CT systems.

Occupational radiation exposure control analyses of 14 MeV neutron generator facility: A neutronic assessment for the biological and local shield design

  • Swami, H.L.;Vala, S.;Abhangi, M.;Kumar, Ratnesh;Danani, C.;Kumar, R.;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1784-1791
    • /
    • 2020
  • The 14 MeV neutron generator facility is being developed by the Institute for Plasma Research India to conduct the lab scale experiments related to Indian breeding blanket system for ITER and DEMO. It will also be utilized for material testing, shielding experiments and development of fusion diagnostics. Occupational radiation exposure control is necessary for the all kind of nuclear facilities to get the operational licensing from governing authorities and nuclear regulatory bodies. In the same way, the radiation exposure for the 14 MeV neutron generator facility at the occupational worker area and accessible zones for general workers should be under the permissible limit of AERB India. The generator is designed for the yield of 1012 n/s. The shielding assessment has been made to estimate the radiation dose during the operational time of the neutron generator. The facility has many utilities and constraints like ventilation ducts, accessible doors, accessibility of neutron generator components and to conduct the experiments which make the shielding assessment challenging to provide proper safety for occupational workers and the general public. The neutron and gamma dose rates have been estimated using the MCNP radiation transport code and ENDF -VII nuclear data libraries. The ICRP-74 fluence to dose conversion coefficients has been used for the assessment. The annual radiation exposure has been assessed by considering 500 h per year operational time. The provision of local shield near to neutron generator has been also evaluated to reduce the annual radiation doses. The comprehensive results of radiation shielding capability of neutron generator building and local shield design have been presented in the paper along with detailed maps of radiation field.

Characteristics of Smoke Propagation in Railway Tunnels with Rescue Station (구난역을 갖는 철도 터널 내부의 연기거동 특성)

  • Jang, Won-Cheol;Kim, Dong-Woon;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.13-18
    • /
    • 2009
  • The main objective of the present study is to investigate smoke propagation in railway tunnels with rescue stations. In particular, based on measurement of HRR (heat release rate) for pool fires formed at different locations, the influence of fire source location on smoke behavior is examined. The fuel is n-heptane and pool fires are generated with a square length 4cm. With the use of MVHS (Modified Volumetric Heat Source) model for fire source, extensive numerical simulations are performed by using the commercial code FLUENT (Ver.6.3) Predicted smoke temperatures and smoke propagation are discussed. From numerical predictions, it is found that ventilation systems may be necessary in the railway tunnels because the smoke moves along the tunnel, and consequently it enters the non-accident tunnel. It is also confirmed that the cross-passage and fire protection wall systems contribute to control the smoke.

Design of an Automatic Generation System of Device Drivers Using Templates (템플릿을 이용한 디바이스 드라이버 자동생성 시스템 설계)

  • Kim, Hyoun-Chul;Lee, Ser-Hoon;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.9C
    • /
    • pp.652-660
    • /
    • 2008
  • Applications running under embedded systems require various device drivers designed for different types and versions of the OS to manage resources effectively. In this paper, an automated device driver generator system which can generate the device drivers to be used in newer versions the target OS is proposed. In the proposed system, the structures of device drivers of specific OS are designed in the templates and stored in a library, and the target device drivers are generated by adding codes to the stored templates. Once device drivers are generated, they are registered into the kernel. The experimental results show that data transfer time has been slightly increased when compared against manually created drivers for TFT-LCD driver, USB interface keyboard/mouse driver, and AC'97 controller drivers. The code size for the generated drivers after compilation has also been increased slightly when compared with manually designed device drivers.

The Effects of Coating Treatments on Enteric Coating of the Soft Capsules Containing Omega-3 Fatty Acids (오메가-3 연질캡슐의 코팅 조건에 따른 장용성 코팅품질에 미치는 영향)

  • Ko, Won-Hwa;Hong, Jun-Kee;Lee, Sung-Wan;Cha, Ja-Hyun;Cha, Jae-Uk;Baek, Hyon-Ho;Park, Hyun-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.168-172
    • /
    • 2012
  • This article presents an evaluation of the effects of coating conditions on the enteric coating quality of soft gelatin capsules containing Omega-3 fatty acids. Three conditions were controlled: concentration of hydroxypropyl methylcellulose phthalate (6, 8, and 10 wt% in solution), temperature of the inlet air (32, 35, and $38^{\circ}C$), and the coating solution feed rate (7.5, 11.25, and 15.0 g/min). The transparency of the enteric coated soft gelatin capsules was evaluated by measuring the degree of whiteness of the surface using a spectrophotometer. Results showed that the most important parameter in the enteric coating process was the coating solution feed rate. As the coating solution feed rate decreased and inlet air temperature increased, the degree of whiteness of coating surfaces decreased. We also evaluated the disintegration properties of the enteric coated capsules in accordance with the Korea Health Functional Food Code.

Design Automation of Slab System by the Finite Element Method (유한요소법을 이용한 슬래브 시스템의 설계자동화)

  • 이성우
    • Computational Structural Engineering
    • /
    • v.4 no.4
    • /
    • pp.79-89
    • /
    • 1991
  • New design method of R/C slab system based on finite element method has been presented. The proposed method can substitute inaccurate existing method, which has limitation in its application, and provide accurate and efficient design results for any type of slab system. Isoparametric plate element used in the slab design has been efficiently formulated to save computational time. Reinforcement has been determined by strength design method and compared with code minimum values. Graphical output through comprehensive contour map for resulting moments and designed steel areas has considerably facilitated design process. Accurate shear results from isoparametric plate element enabled to check punching shear in a proper manner. In addition to strength design criteria, serviceability has also been checked by utilizing newly developed inelastic deflection multiplier method. An example for circular slab with opening showed that the proposed method could be applied to design of irregular slab without any difficulty.

  • PDF

Confirmation of Chestnut Powdery Mildew, Erysiphe castaneigena, in Korea with Morphological Characteristics and Molecular Analyses (형태적 특징 및 분자적 분석에 의한 밤나무 흰가루병균 Erysiphe castaneigena의 확인)

  • Cho, Sung-Eun;Lee, Sang-Hyun;Lee, Sun Keun;Shin, Hyeon-Dong
    • The Korean Journal of Mycology
    • /
    • v.45 no.2
    • /
    • pp.145-152
    • /
    • 2017
  • The powdery mildew on Castanea crenata in South Korea was first recorded as Microsphaera alni in 1958. On the basis of its morphological characteristics and host range, the mildew was determined as Microsphaera sinensis in 1988. According to the rules of The International Code of Botanical Nomenclature, M. sinensis was renamed Erysiphe castaneigena in 2006. Nevertheless, taxonomic re-consideration of the morphological and molecular characteristics for the Castanea powdery mildew in Korea has not been performed. In the present study, we studied 34 powdery mildew samples collected from C. crenata in the Korea University Herbarium. On the basis of microscopic examinations of the holomorph and phylogenetic analysis of the internal transcribed spacer regions, we confirmed the powdery mildew fungus as E. castaneigena. In addition, sequence comparison between E. castaneigena and E. alphitoides ex Castanea sp. suggested a close phylogenetic affinity.

Detailed Abundance Analysis for Plant Host Stars

  • Kang, Won-Seok;Lee, Sang-Gak;Kim, Kang-Min
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.27.1-27.1
    • /
    • 2011
  • We obtained the spectra of 93 Planet host stars and 73 normal field stars in F, G, K type using BOES at BOAO. We measured the equivalent width of Fe and 25 elements lines using the automatic EW measurement program, TAME(Tools for Automatic Measurement of Equivalent-widths) and estimated the elemental abundances by synth and abfind driver of MOOG code. Since the absence of planets in the normal field stars cannot be "completely" proved, this work focused on the chemical abundances and planet properties of planet host stars, which have the massive planets close to the parent star relatively. We carried out an investigation for the difference of abundances between stars with "Hot Jupiter" and normal field stars with no known planets. We examined the chemical composition of 25 elements, such as C, N, O, S, Na, Mg, Al, Si, K, Ca, Sc, Ti, V, Cr, Mn, Co, Ni, Cu, Zn, Sr, Y, Zr, Ba, Ce, Nd, and Eu by EW measurements, and the S abundances were estimated using synthetic spectrum. We have found that [Mg/Fe] and [Al/Fe] for planet host stars have lower limit comparing with those of comparison stars, and [Ca/Fe] of host star with Neptunian planets is relatively lower than the other host stars with massive planets. We have performed the Kolmogorov-Smirnov test, and examined the ratio of planet host stars to all stars for each bin of [X/H]. As a result, we noted that the O, Si, and Ca abfor undances are strongly related with the presence of planets.

  • PDF

Seismic Performance of Precast Concrete Beam-Column Connections Using Ductile Rod (연성 강봉을 사용한 프리캐스트 콘크리트 보-기둥 접합부의 내진성능)

  • Lee, Sang-Jin;Hong, Sung-Gul;Lim, Woo-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.695-705
    • /
    • 2014
  • Precast concrete (PC) beam-column connections using ductile rods are proposed for earthquake zone. An existing beam-column connection, two PC specimens designed by considering failure modes and a conventional RC specimen were tested under cyclic loading to evaluate the seismic performance. The specimens were designed to satisfy the requirements of current design code. The variables are the yield strength of longitudinal reinforcing bars of PC beams. The test results showed that the proposed system applying smaller yield strength of the longitudinal reinforcing bars at the PC beams than the ductile rods was satisfied with seismic criteria. The deformation capacity and energy dissipation capacity of the proposed PC beam-column connections were greater than those of the existing DDC system.

Conjugate Heat Transfer Analysis for High Pressure Cooled Turbine Vane in Aircraft Gas Turbine (항공기용 가스터빈의 고압 냉각터빈 노즐에 대한 복합열전달 해석)

  • Kim, Jinuk;Bak, Jeonggyu;Kang, Young-Seok;Cho, Jinsoo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.60-66
    • /
    • 2015
  • Conjugate heat transfer analysis was performed to investigate the flow and cooling performance of the high pressure turbine nozzle of gas turbine engine. The CHT code was verified by comparison between CFD results and experimental results of C3X vane. The combination of k-${\omega}$ based SST turbulence model and transition model was used to solve the flow and thermal field of the fluid zone and the material property of CMSX-4 was applied to the solid zone. The turbine nozzle has two internal cooling channels and each channel has a complex cooling configurations, such as the film cooling, jet impingement, pedestal and rib turbulator. The parabolic temperature profile was given to the inlet condition of the nozzle to simulate the combustor exit condition. The flow characteristics were analyzed by comparing with uncooled nozzle vane. The Mach number around the vane increased due to the increase of coolant mass flow flowed in the main flow passage. The maximum cooling effectiveness (91 %) at the vane surface is located in the middle of pressure side which is effected by the film cooling and the rib turbulrator. The region of the minimum cooling effectiveness (44.8 %) was positioned at the leading edge. And the results show that the TBC layer increases the average cooling effectiveness up to 18 %.