• Title/Summary/Keyword: C$_{18}$ SPE cartridge

Search Result 23, Processing Time 0.024 seconds

tans-Resveratrol Content of Varieties and Growth Period in Peanut (땅콩 품종 및 생육기별 trans-Resveratrol 함량)

  • Lee, Mi-Ja;Cheong, Young-Keun;Kim, Hyung-Soon;Park, Ki-Hun;Doo, Hong-Soo;Suh, Duck-Yong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.6
    • /
    • pp.429-433
    • /
    • 2003
  • trans-Resveratrol(3,5,4'-trihydroxystilbene) is phenolic compound present in grapes, wines, and peanuts, has been reported to have health benefits including anticarcinogenic effects, protection against cardiovascular diseases and reduced cancer risk. A simple method for the quantitative extraction of trans-resveratrol from peanut has been developed. Optimal conditions for extraction were investigated. Type of solvent, time, and temperature assayed influenced trans-resveratrol yield. Adequate extraction condition was decided to ethanol/water (80:20v/v) maintained at $25^{\circ}C$ for 45 min. After extraction, the protocol consists of sample preparation using a $\textrm{C}_{18}$ solid-phase extraction (SPE) cartridge after concentrate with rotary evaporator and quantified by reversed phase HPLC using a $\textrm{C}_{18}$ column at 308 nm. Analytical methods for measuring trans-resveratrol in peanut were adapted to isolate, identify, and quantify trans-resveratrol in 11 peanut varieties by HPLC (high-performance liquid chromatography) with UV detector, The 11 peanut varieties content ranged from 0.018 to 1.125 $\mu\textrm{g}/\textrm{g}$ with an average of 0.289 $\mu\textrm{g}/\textrm{g}$. The contents were higher in the seeds with than without testa, regardless of varieties. The trans-resveratrol content was Higher in 110, 130 days after sowing than that of other period.

Analysis of Phoxim Residue in Animal Food Production (Cattle and Pig) by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 식육(소, 돼지)중 잔류 phoxim 분석)

  • Park, Mi-Sun;Lee, Jin-Joo;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.626-632
    • /
    • 2011
  • Phoxim, which is one of veterinary drugs, is a well-known antiparasitic agent in wide use. In this paper, phoxim was extracted from cattle and pig tissue using solid-phase extraction (SPE) employing a silica cartridge with acetonitrile. Liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for the analysis of phoxim from animal tissue was presented. Phoxim was detected on a $C_{18}$ column ($2.1{\times}100\;mm$, $3.5\;{\mu}m$) using a mobile phase of 0.1% formic acid in water and acetonitrile. A linear correlation observed in the calibration curves for cattle (0.0048~2.0 mg/kg) and pig (0.0055~2.0 mg/kg) showed above $r^2$=0.995. Accuracy measured at concentrations ranging from 0.0048 to 0.2 mg/kg was the range of 68.2~106.9%. Limit of detection (LOD) and limit of quantitation (LOQ) were the range of 0.0014~0.0017 mg/kg and 0.0048~0.0055 mg/kg, respectively. The precision (RSD%) was below 11.2%.

An analysis of benzoic acid, methyl paraben and butyl paraben in soy sauce using isotope dilution liquid chromatography mass spectrometry (동위원소희석 질량분석법을 이용한 간장 중의 안식향산, 메틸파라벤, 부틸파라벤의 분석)

  • Ahn, Seonghee
    • Analytical Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.225-231
    • /
    • 2018
  • Benzoic acid, methyl paraben, and butyl paraben are preservatives that have been used in pharmaceutical, cosmetic, and food products. However, as their toxicities for human have been reported, many nations and organizations including Korea have established a regulation limit for thier usage of these preservatives in food products. The present study developed the isotope dilution liquid chromatography mass spectrometry method for accurate determination of three target preseratives in soysauce. In this study, the isotope dilution liquid chromatography mass spectrometry method was developed for accurate determination of three target preservatives in soy sauce. LC separation was optimized considering the pKa of benzoic acid which is lower than those of methyl and butyl parabens. A C18 column was used with 5 mM ammonium acetate and methanol as mobile phases. Mass spectrometry was operated in negative mode and selected reaction monitoring mode (SRM). Soy sauce sample was cleaned-up with C18 SPE cartridge for removing matrix inferences and color material. Optimized conditions and the method were validated with soy sauce reference materials for the analysis of food preservatives from Health Science Authority in Singapore. The measured values of benzoic acid, methyl and butyl paraben agreed well with reference values within their uncertainties.

Establishment of Analytical Method for Pymetrozine Residues in Crops Using Liquid-Liquid Extraction(LLE) (액-액 분배법을 활용한 작물 중 pymetrozine의 잔류분석법 확립)

  • Yoon, Ji-Young;Moon, Hye-Ree;Park, Jae-Hun;Han, Ye-Hoon;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.107-116
    • /
    • 2013
  • Polar pesticides like pymetrozine (log $P_{ow}$: -0.18) are known to be difficult to analyze. The analytical method of pymetrozine using hydromatrix included in the official method of KFDA was uncommon and provided ambiguous evidence to confirm both the identity and the quantity. Therefore, precise single residue analytical method was developed in representative crops for using liquid-liquid extraction (LLE). The pymetrozine residue was extracted with methanol from 11 representative crops which comprised apple, blueberry, broccoli, cabbage, cherry, crown daisy, hulled rice, Korean cabbage, potato, rice and watermelon. The extract was purified serially by liquid-liquid extraction (LLE) and silica solid phase extraction (SPE). For rice and hulled rice samples, n-hexane partition was additionally adopted to remove nonpolar interferences, mainly lipids. The residue levels were analyzed by HPLC with DAD, using $C_8$ column. LOQ (limit of quantitation) of pymetroizinie was 1 ng (S/N > 10) and MQL (method quantitation limit) was 0.01 mg/kg. Mean recoveries from 11 crop samples fortified at three levels (MQL, 10 ${\times}$ MQL and 50 ${\times}$ MQL) in triplicate were in the range of 83.1~98.5% with coefficients of variation (CV) of less than 10%, regardless of sample type, which satisfies the criteria of KFDA. The method established in this study could be applied to most of crops as an official and general method for analysis of pymetrozine residue.

Determination of tetracycline antibiotics in food (식품 중 테트라싸이클린계 항생물질의 분석)

  • Park, Dongmi;Jeong, Jiyoon;Chang, Moonik;Im, Moohyeog;Park, Kunsang;Hong, Mooki
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.250-256
    • /
    • 2005
  • A selective method of high performance liquid chromatography with UV detector has been applied to determine 4 tetracycline antibiotics in the animal food, simultaneously. The targets were chlortetracycline (CTC), doxycycline (DC), oxytetracycline (OTC), and tetracycline (TC) that are used routinely in veterinary medicine for prevention and control of disease. Food samples were beef, pork, chicken, milk, whole egg, flatfish (Limanda yokohamae), jacopever (Sebastes hubbsi), seabream (Chrysophrys major), eel (Anguilla japonica) and lobster (Hommarus americanus). After extracting food samples with 20% trichloroacetic acid and McIlvaine buffer, they were purified by a $C_18$ SPE cartridge with 0.01M methanolic oxalic acid solution. The concentrated residue was re-dissolved in methanol, filtered, cleaned up and analyzed on a $C_18$ column. The mobile phase was a mixture of 0.01M oxalic acid and acetonitrile with a gradient ratio from 85:15 to 60:40. The UV wavelength was 365 nm. The overall recoveries were ranged from 71% to 98% and the limit of detections were 0.022 for CTC, 0.012 for DC and OTC and 0.009 mg/kg for TC at signal/noise > 3, respectively. As results, CTC, DC and TC were not detected in all selected food samples, however, OTC was detected in meat and fishes. The determined level of OTC was 0.04 ppm for pork, 0.17 ppm for flatfish and 0.05 and 0.08 ppm for jacopever, that were within the Maximum Residue Limits (MRLs) in the food.

Quantitative analyses of ricinoleic acid and ricinine in Ricinus communis extracts and its biopesticides

  • Choi, Geun Hyoung;Kim, Leesun;Lee, Deuk Yeong;Jin, Cho long;Lim, Sung-Jin;Park, Byung Jun;Cho, Nam-Jun;Kim, Jin-Hyo
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.2
    • /
    • pp.165-169
    • /
    • 2016
  • The quantitative analytical method for the bioactive substance, 3-cyano-4-methoxy-N-methyl-2-pyridone (ricinine) and an index compound, ricinoleic acid in castor plant (Ricinus communis) extract or oil was developed. For the determination of a pyridone alkaloid compound, ricinine, successive cartridge cleanup method combined with ultra-performance liquid chromatography was set up with $ENVI-Carb^{TM}$ (0.5 g) and $C_{18}$ SPE cartridges. Accuracy and precision were evaluated through fortification studies of one biopesticide (PE) at 10 and $100mg\;kg^{-1}$. Mean recoveries of ricinine were 98.7 and 96.0 % associated with less than 10 % RSD, respectively. For the determination of ricinoleic acid in castor extract and oil, saponification and methylation were optimized using gas chromatography-time of flight mass spectrometry. Recovery was more than 84.8 % associated with 6.2 % RSD after derivatization procedure. Both methodologies developed were applied to analyze real samples including three castor oil products and six commercially available biopesticides containing R. communis, collected at Korean market. The contents of ricinine and ricinoleic acid in most commercial biopesticides were less than the oil or extract contents indicated by label.

Study for Residue Analysis of Fluxametamid in Agricultural Commodities

  • Kim, Ji Young;Choi, Yoon Ju;Kim, Jong Soo;Kim, Do Hoon;Do, Jung Ah;Jung, Yong Hyun;Lee, Kang Bong;Kim, Hyochin
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • BACKGROUND: Accurate and simple analytical method determining Fluxametamid residue was necessary in various food matrices. Additionally, fulfilment of the international guideline of Codex (Codex Alimentarius Commission CAC/GL 40) was required for the analytical method. In this study, we developed Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method to determine the Fluxametamid residue in foods. METHODS AND RESULTS: Fluxametamid was extracted with acetonitrile, partitioned and concentrated with dichloromethane. To remove the interferences, silica SPE cartridge was used before LC-MS/MS (Liquid Chromatography-Tandem Mass Spectrometry) analysis with $C_{18}$ column. Five agricultural commodities (mandarin, potato, soybean, hulled rice, and red pepper) were used as a group representative to verify the method. The liner matrix-matched calibration curves were confirmed with coefficient of determination ($r^2$) greater than 0.99 at calibration range of 0.001-0.25 mg/kg. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. Mean average accuracies were shown to be 82.24-115.27%. The precision was also shown to be less than 10% for all five samples. CONCLUSION: The method investigated in this study was suitable to the Codex guideline for the residue analysis. Thus, this method can be useful for determining the residue in various food matrices as routine analysis.

Comparative Study of the Efficiency of GC with Large Volume Injector and SPE Clean-up Process Applied in QuEChERS Method (GC-대용량 주입장치와 SPE를 적용한 QuEChERS 잔류농약 분석법의 효율성 비교)

  • Park, Young Jun;Hong, Su Myeong;Kim, Taek Kyum;Kwon, Hye Young;Hur, Jang Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.4
    • /
    • pp.370-393
    • /
    • 2015
  • This study was conducted to compare STQ method, multi-residue method in Korean food code and QuEChERS method for validated selected and accuracy, reproducibility and efficiency. A total of 45 selected and targeted pesticides were the analyzed by GC and 5 of them were crops (apple, potato, green pepper, rice, soy bean). $R^2$ values were calculated in the standard calibration curve was over 0.990. Recovery tests were performed by three replications in two levels and the relative standard deviation of the repeated experiments was less than 30%. The average percentage of recoveries in the multi-residue method in Korean food code was 89.13%, QuEChERS method was 92.45% and STQ method was 85.28%. In addition, matrix effects in multi-residue method in Korean food code was 24.61%, QuEChERS method was 23.98% and STQ method showed 11.24%. The STQ method is easy and showed high clean-up effect in extracting the sample solution than the QuEChERS method and clean-up with C18, PLS, PSA cartridge columns. A large volume of the sample was injected in order to compensable for the problem, that occurred due to high detection limit in the analyser. When the STQ method was applied using a large volume injector, the standard calibration curve showed a higher linearity $R^2=0.990$, and method detection limit was 0.01 mg/kg. It showed an average recovery of 91.84% and the relative standard deviations of three replications repeated in two level process was less than 30% and had an average matrix effect of 17.90%.

Purification and Characterization of Antibacterial Compound Produced by Bacillus subtilis MJP1 (Bacillus subtilis MJP1이 생산하는 항세균 물질의 분리.정제 및 특성규명)

  • Yim, Eun-Jung;Yang, Eun-Ju;Chang, Hae-Choon
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.1
    • /
    • pp.84-92
    • /
    • 2010
  • Antibacterial compound from Bacillus subtilis MJP1 was purified using C18 Sep-Pak cartridge, ion exchange chromatography, and gel filtration chromatography. The purified antibacterial compound showed antibacterial activity against Listeria monocytogenes, Bacillus subtilis, Staphylococcus aureus subsp. aureus, and Enterococcus faecalis. The purified antibacterial compound was found to be stable at $100^{\circ}C$ for 5 min and in the pH range of 3.0~9.0, but it was unstable at pH 10.0. It was inactivated by proteinase K and pronase E, and heat treatment at $121^{\circ}C$ for 15 min, but it was stable with lipase and $\alpha$-amylase treatment, which indicated its proteineous nature. Ultra performance liquid chromatography and electrospray ionization tandem mass spectrometry analysis were used to identify the purified antibacterial compound and confirmed the existence of two peptides (3356.54 Da, 3400.5244 Da).

Automated Synthesis of [$^{18}F$]Fallypride for Routine Clinical Use (자동합성장치를 이용한 [$^{18}F$]Fallypride의 합성)

  • Park, Jun-Hyung;Moon, Byung-Seok;Lee, Hong-Jin;Lee, Hyo-Jun;Lee, In-Won;Lee, Byung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.104-109
    • /
    • 2010
  • Purpose: $[^{18}F]$Fallypride plays an effective radiotracer for the study of dopamine $D_2/D_3$ receptor occupancy, neuropsychiatric disorders and aging in humans. This tracer has the potential for clinical use, but automated labeling efficiency showed low radiochemical yields about 5~20% with relatively long labelling time of fluorine-18. In present study, we describe an improved automatic synthesis of [$^{18}F$]Fallypride using different base concentration for routine clinical use. Materials and Methods: Fully automated synthetic process of [$^{18}F$]Fallypride was perform using the TracerLab $FX_{FN}$ synthesizer under various labeling conditions and tosyl-fallypride was used as a precursor. [$^{18}F$]Fluoride was extracted with various concentration of $K_{2.2.2.}/K_2CO_3$ from $^{18}O$-enriched water trapped on the ion exchange cartridge. After azeotropic drying, the labeling reaction proceeded in $CH_3CN$ at $100^{\circ}C$ for 10 or 30 min. The reaction mixture was purified by reverse phase HPLC and collected organic solution was exchanged by tc-18 Sep-Pak for the clinically available solution. Results: The optimal labeling condition of [$^{18}F$]Fallypride in the automatic production was that 2 mg of tosyl-fallypride in acetonitrile (1 mL) was incubated at $100^{\circ}C$ for 10 min with $K_{2.2.2.}/K_2CO_3$ (11/0.8 mg). [$^{18}F$]Fallypride was obtained with high radiochemical yield about $66{\pm}1.4%$ (decay-corrected, n=28) within $51{\pm}1.2$ min including HPLC purification and solid-phase purification for the final formulation. Conclusion: [$^{18}F$]Fallypride was prepared with a significantly improved radiochemical yield with high specific activity and shorten synthetic time. In addition, this automated procedure provides the high reproducibility with no synthesis failures (n=28).

  • PDF