• Title/Summary/Keyword: By-pass Flow Rate

Search Result 79, Processing Time 0.026 seconds

Effect of processing parameters on TiO2 film by room temperature granule spray in vacuum (상온진공과립분사에 의한 TiO2 코팅층에 미치는 공정변수의 영향)

  • Kim, Han-Gil;Park, Yoon-Soo;Bang, Kook-Soo;Park, Dong-Soo;Park, Chan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • $TiO_2$ films, thickness of $1{\sim}30{\mu}m$ were deposited on glass substrate at room temperature by room temperature granule spray in vacuum. The starting powder was calcinated at $600^{\circ}C$ for 4 h using $Al_2O_3$ crucible in the furnace. The particle size of the $TiO_2$, $1.5{\mu}m$ was measured by a particle size analyzer. The effect of different process parameters such as number of pass, gas flow rate and feeder voltage was studied. As the number of passes increased, the film thickness increased proportionally due to adequate kinetic energy conserved. The effect of three different flow rates (i.e. 15, 25, and 35 LPM) on deposited film was investigated. As gas flow rate increased, the film thickness increased up to 25 LPM and then decreased. Higher feeder voltage with low flow rate of 15 LPM resulted in unsufficient coating thickness due to insufficient kinetic energy. Microstructure of $TiO_2$ films was investigated by scanning electron microscope and high resolution tramission electron microscope.

Vacuum Plasma Sprayed NiTiZrSiSn Coating (진공 열 플라즈마 용사공정을 통한 NiTiZrSiSn 벌크 비정질 코팅 형성)

  • Yoon, Sang-Hoon;Kim, June-Seob;Kim, Soo-Ki;Lee, Chang-Hee
    • Journal of Welding and Joining
    • /
    • v.25 no.4
    • /
    • pp.42-48
    • /
    • 2007
  • An inert gas atomized NiTiZrSiSn bulk metallic glass feedstock was sprayed onto the copper plate using vacuum plasma spraying process. In order to change the in-flight particle energy, that is, thermal energy, the hydrogen gas flow rate in plasma gas mixture was increased at the constant flow rate of argon gas. Coating and single pass spraying bead were produced with the least feeding rate. Regardless of the plasma gas composition, fully melted through unmelted particle could be observed on the overlay coating. However, the frequency of the unmelted particle number density was increased with the decrease of the hydrogen gas flow rate. The amorphous phase fraction within coating was also affected by the number density of the unmelted particle.

Experiment and Assessment of Ascending Capability for Management of Exotic Fish Species (외래어종 관리를 위한 소상 실험 및 평가)

  • Kang, Joon-Gu;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.265-278
    • /
    • 2016
  • In this study, an ascending capability experiment was performed with largemouth bass and bluegill, which are exotic fish species inhabiting (the freshwaters) in Korea. The experiment was performed by dividing the subject fish into four groups according to their size and at four flow rates for each group. The number of fish passing through a reference line was analyzed by recording videos, and their swimming and ascending capabilities were observed by the naked eye. The number of fish passing through the reference line did not include those returning downstream within five minutes due to the high flow rate. The flow rate used for the analysis was the mean of the flow rate values measured at the left bank, the right bank, and in the middle of the stream. The results showed that the number of exotic fish migrating upstream decreased as the flow rate increased, regardless of the species and size of the fish. The comparison between the fish species showed that the ascending capability of bass was higher than that of bluegill, but the difference was not significant when considering the difference in the size of the fish. In addition, the upper limit flow velocity allowing the ascending of the exotic fish species was 1.11 m/s, when considering the fish returning to the downstream after the upstream migration and experimental error. The results of the experiment may be used as fundamental data for the blocking of fish and the management of exotic fish species by means of a high flow rate current. Further experiments, verification, and monitoring may need to be conducted continuously to determine whether the fish are able to pass through the reference line at a high flow rate, when they attain a high or cruising velocity. Additionally, the reaction of the fish species should be investigated by considering the response to external forces as well as pressure differences due to the flow rate.

The study of catalytic combustion of VOCs (휘발성 유기염소화합물의 촉매연소 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.169-177
    • /
    • 2006
  • In this study, it was studied that the removal rate of VOC by the catalytic combustion. The combustion temperature was changed by the contact type of VOC(space velocity and catalyst depth) and the space velocity(SV) was defined by the rate of gas volume flow rate(Q, $m^3/hr$) over volume(V, $m^3$) of catalyst (SV=Q/V). The space velocity of catalytic combustor is maintained $10,000{\sim}50,000hr^{-1}$. it was studied that the conversion rate of VOC by the catalytic combustion. The combustion temperature was changed by the contact type of VOC and catalyst and the space velocity was defined by the rate of gas volume flow rate over volume of catalyst. The VOC which pass thru the heat exchanger was measured by the hydro ionic detector and measured the VOC removal rate by the activated catalyst in the reaction temperature range of 373K-423K. The removal rate was measured over 100 times. In the automobile painting booth The VOC concentration was 63.37ppm and the removal rate was 70 % at 373K and 78.92% at 423K. The removal rate was increased as increased the temperature.

  • PDF

Preparation of Storage-Stable Liquid Dyes by Membrane Separation Technology (막분리 기술을 위한 액체염료 제조에 관한 연구)

  • Cho, Jung Hee;Lee, Chung Hak
    • Applied Chemistry for Engineering
    • /
    • v.3 no.2
    • /
    • pp.349-359
    • /
    • 1992
  • Studies were carried out on the selective removal of inorganic salts such as NaCl and $Na_2SO_4$ from dye solution, using counter diffusion-reverse osmosis and nanofiltration, respectivey. For the dye solution used in the experiments, 1 to 30% of salts were removed by counter diffusion while the loss of dye molecules was less than 0.3%. The separation factors by one pass operation were 10-500 according to ionic species. In five successive operations, removals of anion($Cl^-$) increased but those of cation($Na^+$) decreased due to the Donnan effect. Effects of feed flow rate on removal efficiencies of various ions were also observed at constant flow rate of stripping water. Reverse osmosis of desalted dye solution by counter diffusion was conducted to prepare highly concentrated liquid dyes. The rejection efficiency of dye molecules was greater than 99%. For the rejection efficiency of chloride ion, experimental values were compared with theoretical ones based on solution-diffusion model. Two stage diafiltration was performed in nanofiltration. The rejection efficiency of chloride ion was continuously decreased due to the Donnan dialysis and even negative rejection was observed. The Donnan effect was more pronounced in the second diafiltration.

  • PDF

A Design Process for Reduction of Pressure Drop of Air-cooled Condenser for Waste Heat Recovery System (폐열 회수 시스템용 공랭식 응축기의 압력 손실 저감 설계)

  • Bae, Sukjung;Heo, Hyungseok;Park, Jeongsang;Lee, Hongyeol;Kim, Charnjung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.81-91
    • /
    • 2013
  • A novel design process of a parallel multi-flow type air-cooled condenser of a dual-loop waste heat recovery system with Rankine steam cycles for improving the fuel efficiency of gasoline automobiles has been investigated focusing on reduction of the pressure drop inside the micro-tubes. The low temperature condenser plays a role to dissipate heat from the system by condensing the low temperature loop working fluid sufficiently. However, the refrigerant has low evaporation temperature enough to recover the waste from engine coolant of about $100^{\circ}C$ but has small saturation enthalpy so that excessive mass flow rate of the LT working fluid, e.g., over 150 g/s, causes enormously large pressure drop of the working fluid to maintain the heat dissipation performance of more than 20 kW. This paper has dealt with the scheme to design the low temperature condenser that has reduced pressure drop while ensuring the required thermal performance. The number of pass, the arrangement of the tubes of each pass, and the positions of the inlet and outlet ports on the header are most critical parameters affecting the flow uniformity through all the tubes of the condenser. For the purpose of the performance predictions and the parametric study for the LT condenser, we have developed a 1-dimensional user-friendly performance prediction program that calculates feasibly the phase change of the working fluid in the tubes. An example is presented through the proposed design process and compared with an experiment.

Two-dimensional numerical experiment considering cohort size and wood jam characteristic on driftwood (유목의 유입규모와 군집특성을 고려하는 2차원 수치모의 실험)

  • Kang, Taeun;Jang, Chang-Lae
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.6
    • /
    • pp.407-418
    • /
    • 2021
  • In this study, the two-dimensional flow model, Nays2DH, and driftwood dynamics model were combined to analyze the flow and driftwood behavior depending on the characteristics of the inflow of driftwood and the length of the driftwood stem. In particular, the Dashpot-spring model was added to the driftwood dynamics model to simulate the collision motion of the driftwood, and the wood jam characteristics by the collision of the driftwood were compared. As a result of the simulation, the pass rate of the obstacle section, the travel distance of wood jam, and the mean position of the wood pieces were respondent sensitively by the length of the driftwood stem, but the cohort size of the driftwood supply was insignificant excepting for the pass rate. Through this study, we could understand the interaction between hydraulic structures and driftwood, and through this, it is believed that it will be helpful in establishing a durable maintenance plan for hydraulic structures by predicting the transport and jam formation phenomena of driftwood in advance.

Glass Dissolution Rates From MCC-1 and Flow-Through Tests

  • Jeong, Seung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.257-258
    • /
    • 2004
  • The dose from radionuclides released from high-level radioactive waste (HLW) glasses as they corrode must be taken into account when assessing the performance of a disposal system. In the performance assessment (PA) calculations conducted for the proposed Yucca Mountain, Nevada, disposal system, the release of radionuclides is conservatively assumed to occur at the same rate the glass matrix dissolves. A simple model was developed to calculate the glass dissolution rate of HLW glasses in these PA calculations [1]. For the PA calculations that were conducted for Site Recommendation, it was necessary to identify ranges of parameter values that bounded the dissolution rates of the wide range of HLW glass compositions that will be disposed. The values and ranges of the model parameters for the pH and temperature dependencies were extracted from the results of SPFT, static leach tests, and Soxhlet tests available in the literature. Static leach tests were conducted with a range of glass compositions to measure values for the glass composition parameter. The glass dissolution rate depends on temperature, pH, and the compositions of the glass and solution, The dissolution rate is calculated using Eq. 1: $rate{\;}={\;}k_{o}10^{(ph){\eta})}{\cdot}e^{(-Ea/RT)}{\cdot}(1-Q/K){\;}+{\;}k_{long}$ where $k_{0},\;{\eta}$ and Eaare the parameters for glass composition, pH, $\eta$ and temperature dependence, respectively, and R is the gas constant. The term (1-Q/K) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_{0},\;{\eta}\;and\;E_{a}$ are the parameters for glass composition, pH, and temperature dependence, respectively, and R is the gas constant. The term (1-Q/C) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_0$, and Ea are determined under test conditions where the value of Q is maintained near zero, so that the value of the affinity term remains near 1. The dissolution rate under conditions in which the value of the affinity term is near 1 is referred to as the forward rate. This is the highest dissolution rate that can occur at a particular pH and temperature. The value of the parameter K is determined from experiments in which the value of the ion activity product approaches the value of K. This results in a decrease in the value of the affinity term and the dissolution rate. The highly dilute solutions required to measure the forward rate and extract values for $k_0$, $\eta$, and Ea can be maintained by conducting dynamic tests in which the test solution is removed from the reaction cell and replaced with fresh solution. In the single-pass flow-through (PFT) test method, this is done by continuously pumping the test solution through the reaction cell. Alternatively, static tests can be conducted with sufficient solution volume that the solution concentrations of dissolved glass components do not increase significantly during the test. Both the SPFT and static tests can ve conducted for a wide range of pH values and temperatures. Both static and SPFt tests have short-comings. the SPFT test requires analysis of several solutions (typically 6-10) at each of several flow rates to determine the glass dissolution rate at each pH and temperature. As will be shown, the rate measured in an SPFt test depends on the solution flow rate. The solutions in static tests will eventually become concentrated enough to affect the dissolution rate. In both the SPFt and static test methods. a compromise is required between the need to minimize the effects of dissolved components on the dissolution rate and the need to attain solution concentrations that are high enough to analyze. In the paper, we compare the results of static leach tests and SPFT tests conducted with simple 5-component glass to confirm the equivalence of SPFT tests and static tests conducted with pH buffer solutions. Tests were conducted over the range pH values that are most relevant for waste glass disssolution in a disposal system. The glass and temperature used in the tests were selected to allow direct comparison with SPFT tests conducted previously. The ability to measure parameter values with more than one test method and an understanding of how the rate measured in each test is affected by various test parameters provides added confidence to the measured values. The dissolution rate of a simple 5-component glass was measured at pH values of 6.2, 8.3, and 9.6 and $70^{\circ}C$ using static tests and single-pass flow-through (SPFT) tests. Similar rates were measured with the two methods. However, the measured rates are about 10X higher than the rates measured previously for a glass having the same composition using an SPFT test method. Differences are attributed to effects of the solution flow rate on the glass dissolution reate and how the specific surface area of crushed glass is estimated. This comparison indicates the need to standardize the SPFT test procedure.

  • PDF

Flow Analysis of a Low-Noise Turbo Fan for a Vacuum Cleaner (진공청소기용 저소음 터보팬 내부 유동 해석)

  • Lee, Ki-Choon;Kim, Chang-Jun;Hur, Nahmkeon;Jeon, Wan-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.4 s.21
    • /
    • pp.14-20
    • /
    • 2003
  • In this study an analysis of the flow characteristics in three types of turbo-fans for a vacuum cleaner was performed by using CFD. The characteristics of three models calculated for various rotating speed for flow rates are obtained and compared with measured data. The mixing plane approach is applied to compute the flow between impeller and diffuser. The results show that the model that is modified to reduce fan noise gives stable flow characteristics in operating range than the original model, with both models show similar performance characteristics at the range of high flow rate. Since in the modified model it takes much longer for an impeller blade to pass a diffuser blade than in the original model, and the peak pressure at BPF can be relieved, it is anticipated that the modified model give much lower noise level with similar performance than the original one, which remains to be verified by unsteady computation and measurements. The good agreement between the predictions and measurement results confirms the validity of this study.

Flow Analysis of a Low-Noise Turbo Fan for a Vacuum Cleaner (진공청소기용 저소음 터보팬 내부 유동 특성 해석)

  • Lee Ki-Choon;Kim Chang Jun;Hur Nahmkeon;Jeon Wan Ho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.631-634
    • /
    • 2002
  • The study of the flow characteristics in two types of turbo-fans for a vacuum cleaner was performed in a previous study. In present study an analysis of a new modified model to reduce fan noise was performed by using CFD. The characteristics of three models calculated for various rotating speeds and flow rates are obtained and compared with available measured data. The results show that the modified model gives stable flow characteristics in operating range than the original model, while both models show similar performance characteristics at the range of high flow rate. Since in the modified model it takes much longer for an impeller blade to pass a diffuser blade than in the original model, and thus the peak pressure at BPF can be relieved, it is anticipated that the modified model gives much lower noise level with similar performance than the original one, which remains to be verified by unsteady computation and measurements.

  • PDF