• 제목/요약/키워드: Bushing model

검색결과 52건 처리시간 0.023초

고속주행용 궤도차량의 동적해석 (Dynamic Anlaysis of High Mobility Tracked Vehicles)

  • 김상두;이승종
    • 한국자동차공학회논문집
    • /
    • 제9권1호
    • /
    • pp.205-215
    • /
    • 2001
  • In this study, modeling and analysis procedure for the dynamic analysis of a high mobility tracked vehicle system were studied. The vehicle model used in this investigation is assumed to be consist of two kinematically decoupled subsystems. The chassis subsystem consists of chassis frame, sprocket, support rollers, road wheels, idler wheel, road wheel arms and idle wheel arm, while the track subsystem is represented as a closed kinematic chain consisting of track links and end connectors interconnected by revolute joints with bushing. Nonlinear contact force module describing the interaction between track link, and sprocket, idler wheel, road wheel, support roller, ground was used. The effects of road wheel arms and idler wheel arm due to tension adjuster are also considered.

  • PDF

17.5 kV Recloser용 Bushing 2종에 대한 전계강도 연구 (A Study on the Electric Field Strength of Two Bushings for 17.5 kV Recloser)

  • 신영준;오연호;김민규;이정기;김수정;김진기;김귀식;정정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.392-395
    • /
    • 2003
  • The study of electric field analyses has been conducted on two kinds of bushings for 17.5kV $SF_6$ gas insulated recloser. In this paper, two model bushings and input conditions for the analyses are described in detail. The results of the electric field analyses are presented and compared with to find out the better design in two bushings. Finally some suggestions are given for improving the insulation characteristics of the bushings.

  • PDF

변압기 부분방전 상시 감시기법에 관한 연구 (A Study on the on Line Monitoring Techniques of the Partial Discharge for Transformer)

  • 권동진;박재준
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.1032-1040
    • /
    • 2001
  • In order to apply the partial discharge measuring technique utilizing electrical pulse to the transformer at sites, this paper describes the measuring technique obtaining only the signals due to internal partial discharge in the transformer, but the noises due to external corona which has been a major problem so far. At first, partial discharge and corona noise were simultaneously generated in the model transformer by using needle-plane electrodes and rod-sphere electrodes out of it in a high voltage laboratory, respectively. It was verified that only the partial discharge signals in the transformer could be measured by removing the noise signals from the superposed signals of partial discharges and noises on the grounding wire of the model transformer. By application to a 345kV transformer in service, it was also confirmed that the partial discharge could be on-line monitored by removing the noise signals measured by the inductance sensor on the grounding wire of a 154kV lightning arrester from the superposed signals of internal partial discharge and external corona noise measured by bushing tap coupler of the transformer.

  • PDF

보조동력장치 연료 공급용 서보밸브 토크모터의 기초 수치모사 연구 (Priliminary Numerical Simulation of the Torque Motor for a Servo Valve in the Fuel Supply System of APU)

  • 장세명;정헌술;장강원;양인영;이원중
    • 유공압시스템학회논문집
    • /
    • 제6권2호
    • /
    • pp.1-6
    • /
    • 2009
  • The APU(Auxiliary Power Unit) needs a set of complex pipeline for the fuel supply system where some of the main valves controlling the flow rate consist of the servo valve worked with a torque motor. The input electric current produces an induced magnetic field almost perpendicular to the background magnetic filed generated by fixed permanent magnets. The induced torque deforms the tubular bushing, and directly rotates an armature, which can open and close the valve. In this study, we start from a basic analytic model using a simple electro-magneto-statics, and expand our model to the three-dimensional one computationally applying a commercial code named COMSOL. The result is compared with each other, and reasonable numerical data are obtained for the dynamic behavior and multi-physics system.

  • PDF

EMTP/RV를 이용한 22.9kV GIS 모델링과 과도회복전압 해석 (22.9kV GIS Modeling and Transient Recovery Voltage Analysis Using EMTP/RV)

  • 정태영;백영식;정기석;박지호;서규석
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1199-1205
    • /
    • 2010
  • The recent power system is required to a large size of facilities and high power technology according to increasing power demand. However, it could lead to spoiling the beauty of city and environment problem. The miniaturized facilities with large capacity such as GIS have been required in recent power system. The GIS(Gas Insulated Substation) using the SF6 insulation gas enables to miniaturize facilities with large capacity with high insulation performance. However, the substation installed GIS has required to new design model which is different from the conventional substation. The TRV(Transient Recovery Voltage) analysis on simple circuit may applied by differential equation. However, in case of relatively complicated system, EMTP(Electro Magnetic Transients Program) mainly has been used to design and simulate for transient analysis. This paper mainly design the 22.9 kV GIS system and analyze the transient recovery voltage of main circuit breaker using EMTP/RV. It also enables to easily design the other substation installed GIS with same maker and voltage level because the proposed GIS model consists of separated modules such as busbar, circuit breaker, bushing, CT, PT etc. Eventually, it contributes to comfortably compare the interrupting performance of circuit breaker and system TRV corresponding to the substation system configuration.

가상시험을 위한 소프트웨어 기반 3채널 가진기 개발 (Development of 3-ch. Vibration Generator S/W for Virtual Test)

  • 김광석
    • 한국융합학회논문지
    • /
    • 제12권1호
    • /
    • pp.205-210
    • /
    • 2021
  • 본 연구에서는 대상 시스템의 목표 값과 동일한 응답 특성을 얻기 위한 가진 입력 데이터의 생성 방법에 대해 연구하였다. 입력-출력 사이의 전달함수인 주파수 응답함수를 사용하여 가진 입력을 재구성하는 방법에 대해 논하였다. 이를 위하여 수치모델로 세 점에서 부싱으로 연결된 엔진 마운트 모델을 사용하였다. 3 방향의 입력에 대한 응답을 시험값과 비교하고, 목표 값과 동일한 응답을 얻을 수 있도록 가진 입력을 보정하였다. 오차함수를 계산한 다음 이 값이 수렴하는지 판단하여 반복 시뮬레이션을 수행하였다. 반복과정을 통해 시험과 동일한 응답을 가질 수 있도록 조정된 가진 입력 값을 얻을 수 있었다.

점탄성 제진 요소의 복소동강성계수 산출을 위한 상용유한요소 코드 이용시 복소탄성계수의 정하중 의존성 반영 방법 (Consideration of Static-strain-dependent Dynamic Complex Modulus in Dynamic Stiffness Calculation of Viscoelastic Mount/Bushing by Commercial Finite Element Codes)

  • 김광준;신윤호
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.372-379
    • /
    • 2006
  • Little attention has been paid to static-strain-dependence of dynamic complex modulus of viscolelastic materials in computational analysisso far. Current commercial Finite Element Method (FEM) codes do not take such characteristics into consideration in constitutive equations of viscoelastic materials. Recent experimental observations that static-strain-dependence of dynamic complex modulus of viscolelastic materials, especially filled rubbers, are significant, however, require that solutions somehow are necessary. In this study, a simple technique of using a commercial FEM code, ABAQUS, is introduced, which seems to be far more cost/time saving than development of a new software with such capabilities. A static-strain-dependent correction factor is used to reflect the influence of static-strains in Merman model, which is currently the base of the ABAQUS. The proposed technique is applied to viscoelastic components of rather complicated shape to predict the dynamic stiffness under static-strain and the predictions are compared with experimental results.

고속 운영을 위한 능동거니플랩 설계 변경 및 고유진동수 예측 (Active Gurney Flap Design Modification for High Speed Operation and Natural Frequency Estimate)

  • 김태주;김도형;백승길
    • 한국소음진동공학회논문집
    • /
    • 제25권10호
    • /
    • pp.667-676
    • /
    • 2015
  • Working displacement variation by elastic deformation of active Gurney flap which was operated on high frequency was observed. Flap-wise natural frequency was lower than mode analysis result and hinge boundary condition was identified to be the cause through the simple modal test. Design modification for increasing natural frequency was conducted for minimizing the elastic deformation at maximum 35 Hz operating condition which was design requirement condition. Brass bushing was applied instead of rotating bearing for gap minimization and Gurney flap design modification was conducted to increase of the flap-wise natural frequency. Design modification effect was validated by natural frequency comparison with mode analysis result and modal test result of design modification model.

구강스캐너를 이용한 임플란트 수술 계획 및 왁스 기반 쾌속조형법으로 제작한 수술용 가이드 증례 (A case report of a surgical guide fabricated via intraoral scanning-based implant planning and wax-based rapid prototyping)

  • 신종훈;박은진;박지만
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.244-249
    • /
    • 2015
  • 최근 디지털 기술이 발달하면서 임플란트 식립 시 가이드 템플릿을 이용하는 컴퓨터 가이드 수술이 활발하게 이루어지고 있으며, 임플란트 보철시 구강스캐너를 이용하는 방법이 소개되고 있다. 가이드 템플릿의 제작방법은 크게 RP 제작 시스템과 벡터 밀링 시스템으로 나눌 수 있는데, 각각은 우수한 정확성에도 불구하고 임상적 적용에 있어 약간의 아쉬운 점을 보이고 있다. 이에 본 증례에서는 CBCT 및 구강스캐너로 획득한 디지털 영상을 이용하여 쾌속조형법으로 왁스재료의 작업모형을 제작하고 그 위에 교정용 레진으로 금속애관을 픽업해 내는 방법을 사용하여 임플란트 수술용 가이드 템플릿을 제작하여 수술에 사용하였으며, 임상적으로 임플란트 식립 및 최종보철물 제작 시 만족스러운 결과를 얻을 수 있어서 이를 보고하고자 한다.

변압기의 내진성능 향상을 위한 마찰진자 면진장치의 시험 연구 (Experimental Study of Friction Pendulum System to Improve the Seismic Capacity of Transformer)

  • 장정범;김정기;황경민;함경원;박진완;이찬욱
    • 한국지진공학회논문집
    • /
    • 제12권2호
    • /
    • pp.1-8
    • /
    • 2008
  • 본 연구에서는 전력설비 중 그 중요도가 가장 큰 변압기를 대상으로, 지진 발생 시 변압기의 파손을 방지하기 위하여 마찰진자 면진장치를 개발하고, 진동대시험을 통하여 그에 대한 내진성능을 입증하였다. 본 연구에서 개발한 마찰진자 면진장치에 대해 압축재하시험 및 마찰시험을 수행한 결과, 변압기의 면진장치로서 적용 가능한 것으로 나타났으며, 특히 변압기 축소모형을 대상으로 진동시험대에 의한 내진성능시험을 수행한 결과, 기존의 일반 고정기초형식보다 변압기 기초부의 최대 응답가속도는 약30%, 부싱 상단의 최대 응답가속도는 약 59% 감소하였다. 또한, 마찰진자 면진장치 설치 후, 변압기의 고유진동수가 약 82% 감소하며 장주기로 이동함을 확인할 수 있었다. 이와 같이 변압기에 마찰진자 면진장치를 적용하는 경우, 지진으로 인한 변압기의 파손을 효과적으로 방지할 수 있을 것으로 판단된다.