• Title/Summary/Keyword: Bus model

Search Result 729, Processing Time 0.027 seconds

Modelling of Transfer Impedance of based an Express Bus Terminal use Behavior (고속버스터미널 이용자의 환승행태에 기반을 둔 환승저항 모형 구축 연구)

  • Kim, Hwang Bae;Kwon, Young Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2D
    • /
    • pp.99-103
    • /
    • 2010
  • It is necessary to improve transfer impedance of express bus terminal users in order to increase the usage of public transportation. This study constructed a model for calculating transfer impedance based on bodily sensational transfer time in express bus terminal and calculated transfer impedance on major express bus terminals in Korea. The study results show that the addition of 100 meter exterior walking distance increases 3 minute travel time, 100 meter interior walking distance increases 5 minute travel time, 100 stairways increase 13 minute travel time, and escalators decreases 3 minute travel time. The calculated transfer impedance based on bodily sensational transfer time in this study can be utilized as objective criteria to compare transfer conditions of different bus terminals and to prioritize them for facility improvement. The calculated transfer impedance also can be used as facility guidelines for designing a new transit center.

Study on Safety Evaluation Process for Hydrogen Storage System of Hydrogen Bus (수소버스 수소저장용기의 측면충돌 안전성 평가방법 연구)

  • Kyungjin, Kim;Jaeho, Shin;Kyeonghee, Han;Hyeon Min, Han;Jeong Min, In;Siwoo, Kim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.4
    • /
    • pp.113-119
    • /
    • 2022
  • The structural safety of hydrogen buses is being evaluated for the successful introduction of hydrogen buses. The crash test methodology, for example, side impact test procedure is being discussed for hydrogen bus structure safety with a compressed hydrogen storage system located under the bus floor. Thus this study describes a new experiment method for side impact test with compressed hydrogen storage system independently based on finite element analysis instead of side impact test using full hydrogen bus. A side crash procedure of conceptual compressed hydrogen storage structure was investigated and impact simulations were performed. The finite element models of hydrogen bus, simplified structures, fuel tank system and side impact moving barrier were set up and simulation results reported model performance and result comparison of three different simplified models. Computational results and research discussion proposed the fundamental test framework for safety assessment of the compressed hydrogen storage system.

A Study of Contingency Screening Method Considering Voltage Security (전압안전도를 고려한 상정사고 스크린닝에 관한 연구)

  • 송길영;김영한;최상규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.2
    • /
    • pp.133-141
    • /
    • 1990
  • In the operation of an electric power system, the voltage security of the system has acquired more significant importance after the occurrence of large system black-outs caused by voltage collapse several times. This paper describes a fast contingency screening method concerning voltage security. The method defines a voltage-sensitive buses where significant voltage changes would occur as a result of the contingency to reduce the number of bus voltages to be solved for continngency screening. This method is based on the observation that it is not necessary to solve the entire network in most contingency cases because boltage changes actually occur around the contingency. The P-Q decoupled linearized model and the fast error correction method are also adopted in the method to define voltage-sensitive buses and to calculate voltage magnitude on the selected voltage-sensitive buses fastly and reliably. The method suggested in this papaer has been tested in IEEE 30-bus model system and KEPCO 130-bus actual system and its effectiveness for practical use has also been confirmed.

  • PDF

Load Characteristic Experiment for Reliability Verification of Load Model in 22.9[kV] Bus (부하모델의 신뢰성 검증을 위한 22.9[kV] 부하모선 선정 및 현장 전압특성실험)

  • Lee, J.P.;Wee, W.S.;Han, M.H.;Kim, K.D.;Park, S.W.;Ji, P.S.;Lim, J.Y.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.322-324
    • /
    • 1999
  • This paper presents the methodology of measuring the 22.9[kV] bus load characteristics for verifying the bus load model developed with equivalent load aggregation of load components, and the analysis of 22.9[kV] load data.

  • PDF

Power Flow Solution Using an Improved Fitness Function in Genetic Algorithms

  • Seungchan Chang;Lim, Jae-Yoon;Kim, Jung-Hoon
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.51-59
    • /
    • 1997
  • This paper presets a methodology of improving a conventional model in power systems using Genetic Algorithms(GAs) and suggests a GAs-based model which can directly solve the real-valued optimum in an optimization procedure. In applying GAs to the power flow, a new fitness mapping method is proposed using the proposed using the probability distribution function for all the payoffs in the population pool. In this approach, both the notions on a way of the genetic representation, and a realization of the genetic operators are fully discussed to evaluate he GAs' effectiveness. The proposed method is applied to IEEE 5-bus, 14-bus and 25-bus systems and, the results of computational experiments suggest a direct applicability of GAs to more complicated power system problems even if they contain nonlinear algebraic equations.

  • PDF

Comparative Analysis of Urban Public Transportation Systems with Emphasis on Subway-Feeder Bus System

  • Lee, Seung-Hawn
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.4 no.1
    • /
    • pp.33-47
    • /
    • 1978
  • This paper attempts to develop a method which combines a subway system with a feeder bus system in order to increase the efficiency of the performance of the subway system. The 'feasible region' where a subway system is more desirable than a conventional bus in its travel time far the CBD-bound trip is determined and the service-specification models of the two systems in this region have been formulated and analyzed in an aggregate manner. The model developed in this study is applied to the Subway Line No. 1 in Seoul. The result obtained in the analysis indicates that the combined system can be guaranteed as a desirable mode in the point of travel time and cost within the feasible region. The concept of the model will lead to a proper assessment of the system's potentials for the choice of an optimal combination of the existing transport technologies.

  • PDF

A Study on Topology Processor for Substation Automation (변전소 자동화를 위한 위상구조 처리에 관한 연구)

  • Lee, H.J.;Wang, I.S.;Kang, H.J.;Lee, S.G.;Hong, J.H.;Kim, D.J.;Kang, M.C.;Lim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.21-22
    • /
    • 2007
  • Topology processing is indispensable basic function as it generate a real-time BUS-BRANCH model in Energy Management Systems because most application softwares such as state estimation, power flow, etc., require BUS-BRANCH circuit data. This paper propose an expert system to generate BUS-BRANCH circuit model using Artificial Intelligence technology and it is applied to 154kV distribution substations.

  • PDF

Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems (부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안)

  • 이유정;김규호;이상근;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.5
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

Research on the Continuous Use Intention of Mobile Bus Payment App from the Perspective of user Quality Perception

  • Li, Shuo;Sun, Cong-Ying
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.9
    • /
    • pp.217-224
    • /
    • 2022
  • Based on the success model and Expectation Confirmation model of information system, the concept model of mobile bus payment App users' willingness to continue using is constructed by introducing function quality and interface design quality. A total of 264 valid questionnaires are obtained by issuing online questionnaires, and the model is tested by SmartPLS3.0 software The results show that users' perceptions of information quality, system quality and interface design quality will affect users' perceived usefulness and satisfaction through the scene, and then affect users' willingness to continue to use; Perceived functional quality has a significant impact on perceived usefulness, but has no significant impact on satisfaction. Perceived usefulness has a significant impact on user satisfaction.

Matching Simulations with Tests of Cruise Bus Using Multi-body Dynamics Technology (다물체동역학기법을 이용한 고급버스의 전차량 시뮬레이션과 시험의 매칭)

  • Choi, So-Hae;Park, Seong-Jun;Lee, Jeong-Han;Yoo, Wan-Suk;Sohn, Jeong-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.14-22
    • /
    • 2010
  • In this study, a large bus is tested for measuring the steering response based on the slarom test and step steer test. A full car model by using ADAMS/Car is established for computer simulation. For bus modeling, user defined templates are made and used in the simulation. Simulation results according to the slarom and step steer test are compared to the physical experiments, in which several sensors are installed to measure vehicle responses. The results obtained from the comparison show a good agreement with regard to the vehicle velocity and steering angle.