• Title/Summary/Keyword: Burn-in-test

Search Result 203, Processing Time 0.044 seconds

Scheduling of Wafer Burn-In Test Process Using Simulation and Reinforcement Learning (강화학습과 시뮬레이션을 활용한 Wafer Burn-in Test 공정 스케줄링)

  • Soon-Woo Kwon;Won-Jun Oh;Seong-Hyeok Ahn;Hyun-Seo Lee;Hoyeoul Lee; In-Beom Park
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.107-113
    • /
    • 2024
  • Scheduling of semiconductor test facilities has been crucial since effective scheduling contributes to the profits of semiconductor enterprises and enhances the quality of semiconductor products. This study aims to solve the scheduling problems for the wafer burn-in test facilities of the semiconductor back-end process by utilizing simulation and deep reinforcement learning-based methods. To solve the scheduling problem considered in this study. we propose novel state, action, and reward designs based on the Markov decision process. Furthermore, a neural network is trained by employing the recent RL-based method, named proximal policy optimization. Experimental results showed that the proposed method outperformed traditional heuristic-based scheduling techniques, achieving a higher due date compliance rate of jobs in terms of total job completion time.

  • PDF

Hardware Burn-in and Software Testing (하드웨어 번인과 소프트웨어 시험)

  • 유영관;이종무
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.05a
    • /
    • pp.77-81
    • /
    • 2001
  • Burn-in is a test procedure to find and eliminate the inherent initial failure of a product during or at the final stage of production process. Software testing is the validation and verification process which is used to cut off the faults from a software. The two have the common function and objective of "debugging". This article summarizes some significant models on the optimal hardware and software burn-in time, and provides the relevant paper lists. The need for the development of the unified burn-in policy of a hardware-software system is addressed.addressed.

  • PDF

Cardiorespiratory Fitness Is Associated with Gait Changes among Firefighters after a Live Burn Training Evolution

  • Colburn, Deanna;Suyama, Joe;Reis, Steven E.;Hostler, David
    • Safety and Health at Work
    • /
    • v.8 no.2
    • /
    • pp.183-188
    • /
    • 2017
  • Background: Recommendations have been proposed for minimum aerobic fitness among firefighters but it is unclear if those criteria relate to performance on the fireground. Less fit individuals fatigue more quickly than fit individuals when working at comparable intensity and may have gait changes, increasing risk of falls. We evaluated the effect of fatigue during a live burn evolution on gait parameters and functional balance comparing them to aerobic fitness levels. Methods: A total of 24 firefighters had gait and balance tested before and after a live burn evolution. Data were stratified by aerobic fitness of greater/less than 14 metabolic equivalents (METs). Results: Analysis of gait cycles measurements before and after the live burn evolution revealed that single leg stance, cycle, and swing time decreased (p < 0.05) but there were no differences in the other measures. There were no differences in time to complete the functional balance test, or errors committed before or after a live burn evolution. When firefighters were sorted by fitness level of 14 METs, there were no differences for errors or time before or after the live burn evolution. Balance data were analyzed using a linear regression. Individuals with lower fitness levels required more time to complete the test. Conclusion: A 14-MET criterion failed to distinguish gait or balance characteristics in this group. However, less fit firefighters did require more time to complete the balance test (p = 0.003). Aerobic fitness alone does not predict gait changes among firefighters following a live burn evolution but does appear to influence functional balance.

Evaluation of the Corrosion Protection Coating in Accordance with Burn Damage (Burn Damage에 따른 도막의 방청성 평가)

  • Seo, ChangHo;Park, JinHwan
    • Corrosion Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.290-296
    • /
    • 2016
  • This study was conducted in order to examine the effect of burn damage and the resultant anti-corrosion performance. The breakdown and defect of the paint film caused by burn damage are considered to affect not only the macroscopic appearance but also the adhesive force and the anti-corrosion performance of the paint film. The material of the paint film was epoxy paint that is used most widely for heavy-duty coating, and in order to induce burn damage, heat treatment with a torch was applied to the other side of the paint film. Surface and chemical structure changes according to aging were analyzed using FE-SEM and infrared absorption spectroscopy, and variation in the anti-corrosion performance was analyzed through the AC impedance test.

Performance Evaluation of Hinge Driving Separation Nut-type Holding and Releasing Mechanism Triggered by Nichrome Burn Wire

  • LEE, Myeong-Jae;LEE, Yong-Keun;OH, Hyun-Ung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.4
    • /
    • pp.602-613
    • /
    • 2015
  • As one of the mission payloads to be verified through the cube satellite mission of Cube Laboratory for Space Technology Experimental Project (STEP Cube Lab), we developed a hinge driving separation nut-type holding and releasing mechanism. The mechanism offers advantages, such as a large holding capacity and negligible induced shock, although its activation principle is based on a nylon cable cutting mechanism triggered by a nichrome burn wire generally used for cube satellite applications for the purpose of holding and releasing onboard appendages owing to its simplicity and low cost. The basic characteristics of the mechanism have been measured through a release function test, static load test under qualification temperature limits, and shock measurement test. In addition, the structural safety and operational functionality of the mechanism module under launch and on-orbit environments have been successfully demonstrated through a vibration test and thermal vacuum test.

Development of Burn Ointment using Algin (Algin을 이용한 화상연고제의 개발)

  • Jung, Duck-Chae;Lee, Ki-Chang
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.187-191
    • /
    • 1999
  • Burns can be caused by fire, chemicals, heated object and fluids. Distinguishing a minor burn from a more serious burn involves determining the degree of damage to the tissues of the body. Algin is known as natural polymer marine plants, we prepared the official burn ointment which is made by Algin. This burn ointment was covered on the skin wound of artificial burned and their effect of healing was investigated by the evaluation of histological and hematological change as a function of time. The result of rats test showed that burn ointments made from Algin was effective in formation of the new tissue and reduction of inflammation.

Application of Rats According to Molecular Weight of Chitosan (키토산의 분자량에 따른 랫드에서의 적용)

  • Jung, Duck-Chae;Lee, Ki-Chang;Yoon, Cheol-Hun;Kim, Pan-Gyi;Shin, Dong-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.58-63
    • /
    • 1999
  • Biodegradable films were prepared by solution blend method in the weight ratio of chitosan for the purpose of useful biomaterials. The possibility of biomaterials prepared from natural polymer as a skin substitute was evaluated by measuring biocompatibility. These films were inserts in the back of rat and their biodegradability was investigated by the film weight and hematology as a function of time for the biotransformation. The result of rat test showed that medium, high viscosity chitosan induced some suspects of inbiocompatibility in the tissue by goreign body reaction 48 and 72 hours after implantation. Also, we prepared the official burn ointment which is made by low viscosity chitosan. This burn ointment was covered on the skin wound of artificial burn and their effect of healing was investigated by the evaluation of the naked eye and hematological change as a function of time. The result of rats test showed that burn ointments made from chitosan was effective reductio of inflammation than negative group.

  • PDF

Evaluation of the Effects of Self-Managed Percussion Therapy Using Video Education: A One-Group Pretest-Posttest Pilot Study for Burn Patients' Pruritus Management (화상환자의 소양증 관리를 위한 경타법 적용 효과)

  • Kim, Kyung Ja;Kim, Hye Youn;Seo, Cheong Hoon;Kim, Dohern;Oh, Hyunjin
    • Journal of Home Health Care Nursing
    • /
    • v.30 no.2
    • /
    • pp.194-201
    • /
    • 2023
  • Purpose: Post-burn pruritus is one of the most prevalent complications experienced by burn patients. Though medications are prescribed for pruritus, managing this condition can prove challenging. The aim of this research was to develop and disseminate non-pharmacological self-management educational resources, and subsequently evaluate the effectiveness of implementing a percussion therapy approach. Methods: A one-group pretest-posttest design was employed to evaluate the effect of percussion therapy on one hundred patients, all of whom had suffered deep second-degree burns and undergone skin graft surgery. Variables such as the severity of pruritus, distress caused by pruritus, and satisfaction with pruritus treatment were scrutinized. A paired t-test was conducted to compare these variables before and after the intervention. Results: The majority of participants were diagnosed with third-degree burns, and the average Total Body Surface Area (TBSA) affected was 25.2%. Post-test results revealed a marked reduction in both severity and distress caused by pruritus. The intervention led to significant decreases in average severity and pain due to itchiness, and an increase in the satisfaction level following the application of percussion therapy. Conclusions: The implementation of the percussion was identified as effective in diminishing post-burn pruritus, alleviating pruritus-associated pain, and enhancing satisfaction with pruritus treatment. The percussion approach presents itself as a non-invasive, non-pharmacological strategy for managing pruritus in burn patients.

Thermal Performance Evaluations of Tungsten/Yttria as Nozzle Throat Insert Material for Long Duration Firing (장시간 연소 텅스텐/이트리아 노즐목 삽입재의 내열성능 평가)

  • Kang, Yoon-Goo;Park, Jong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.200-205
    • /
    • 2010
  • Heat-resistance of W/$Y_2O_3$ as throat insert material was evaluated to develop rocket motor keeping thrust uniformly under condition of high-temperature, high-pressure and long-burn time. Test was conducted with varying burn time, and test results were compared with CIT. Test showed that ablation rate was decreased according as burn time was increased, and that ablation rate of W/$Y_2O_3$ was about 55 % of CIT. Macro/micro structures of throat insert did not show a peculiar phenomenon by increased burn time. In addition, the vacuum heat treatment is effective for the prevention of crack in throat insert.

Bee venom reduces burn-induced pain via the suppression of peripheral and central substance P expression in mice

  • Kang, Dong-Wook;Choi, Jae-Gyun;Kim, Jaehyuk;Park, Jin Bong;Lee, Jang-Hern;Kim, Hyun-Woo
    • Journal of Veterinary Science
    • /
    • v.22 no.1
    • /
    • pp.9.1-9.11
    • /
    • 2021
  • Background: Scalding burn injuries can occur in everyday life but occur more frequently in young children. Therefore, it is important to develop more effective burn treatments. Objectives: This study examined the effects of bee venom (BV) stimulation on scalding burn injury-induced nociception in mice as a new treatment for burn pain. Methods: To develop a burn injury model, the right hind paw was immersed temporarily in hot water (65℃, 3 seconds). Immediately after the burn, BV (0.01, 0.02, or 0.1 mg/kg) was injected subcutaneously into the ipsilateral knee area once daily for 14 days. A von Frey test was performed to assess the nociceptive response, and the altered walking parameters were evaluated using an automated gait analysis system. In addition, the peripheral and central expression changes in substance P (Sub P) were measured in the dorsal root ganglion and spinal cord by immunofluorescence. Results: Repeated BV treatment at the 2 higher doses used in this study (0.02 and 0.1 mg/kg) alleviated the pain responses remarkably and recovered the gait performances to the level of acetaminophen (200 mg/kg, intraperitoneal, once daily), which used as the positive control group. Moreover, BV stimulation had an inhibitory effect on the increased expression of Sub P in the peripheral and central nervous systems by a burn injury. Conclusions: These results suggest that a peripheral BV treatment may have positive potency in treating burn-induced pain.