The biodegradation experiment, the TOD analysis and the element analysis for dispersant, Bunker-A oil and Bunker-B oil were conducted to study the biodegradation characteristics of a mixture of Bunker-A oil with dispersant and a mixture of Bunker-B oil with dispersant in the seawater. The results of biodegradation experiment showed 1mg of dispersant to be equivalent to 0.26 mg of $BOD_5$ and to 0.60 mg of $BOD_{20}$ in the natural seawater. The results of TOD analysis showed each 1 mg of dispersant, Bunker-A oil and Bunker-B oil to be equivalent to 2.37 mg, 2.94 mg and 2.74 mg of TOD, respectively. The results of element analysis showed carbon, hydrogen, nitrogen and phosphorus contents of dispersant to be $82.1\%,\;13.8\%,\;1.8\%\;and\;2.2\%$, respectively. Carbon and hydrogen contents of Bunker-A oil were found to be $73.3\%\;and\;13.5\%$, respectively, and carbon, hydrogen and nitrogen contents of Bunker-B oil to be $80.4\%,\;12.3\%\;and\;0.7\%$, respectively. Accordingly, the detection of nitrogen and phosphorus in dispersant shows that dispersants should be used with caution in coastal waters, with relation to eutrophication. The biodegradability of dispersant expressed as the ratio of $BOD_5/TOD$ was found to be $11.0\%$. As the mix ratios of dispersant to Bunker-A oil (3 mg/l) and a mixture of Bunker-B oil (3mg/l) were changed from 1 : 10 to 5 : 10, the biodegradabilities of a mixture of Bunker-A oil with dispersant and Bunker-B oil with dispersant increased from $2.1\%\;to\;7.2\%$ and from $1.0\%\;to\;4.4\%$, respectively. Accordingly, the dispersant belongs to the organic matter group of middle-biodegradability while mixtures in the mix ratio range of $1:10\~5:10$ belong to the organic matter group of low-biodegradability. The deoxygenation rate constant $(K_1)$ and ultimate biochemical oxygen demand $(L_0)$ obtained from the biodegradation experiment and Thomas slope method were found to be 0.125/day and 2.487 mg/l for dispersant (4 mg/l), respectively. $K_1\;and\;L_0$, were found to be $0.079\~0.131/day$ and $0.318\~2.052\;mg/l$ for a mixture of Bunker-A oil with dispersant and to be $0.106\~0.371/day$ and $0.262\~1.106\;mg/l$ for a mixture of Bunker-B oil with dispersant, respectively, having $1:10\~5:10$ mix ratios of dispersant to Bunker-A oil and Bunker-B oil. The ultimate biochemical oxygen demands of the mixtures increased as the mix ratio of dispersant to Bunker-A, B oils changed from 1 : 10 to 5 : 10. This suggests that the more dispersants are applied to the sea for the cleanup of Bunker-A oil or Bunker-B oil, the more decreases the dissolved oxygen level in the seawater.
Kim, Hee-Goo;Park, Geun-Tae;Son, Hong-Joo;Lee, Sang-Joon
Environmental Sciences Bulletin of The Korean Environmental Sciences Society
/
v.4
no.4
/
pp.227-230
/
2000
Bunker-A oil-degrading microorganisms were isolated from a marine environment using an enrichment culture technique. The isolated strain EL-081K was identified as the genus Acinetobacter based on the results of morphological, culture, and biochemical tests. The optimal temperature and initial pH for bunker-A oil degradation were $25^{\circ}C$ and 7.0, respectively, including aeration. The optimal medium composition for the degradation of bunker-A oil by Acinetobacter sp. EL_O81K was 10 ml/l bunker-A oil as the carbon source and 0.1% (NH$_4$)$_2$SO$_4$as the nitrogen source. Under the above conditions, the biodegradability of bunker-A oil was 38% after 96 hours of incubation. The addition of detergent did not increase the bunker-A oil degradation.
Proceedings of the Korea Society for Energy Engineering kosee Conference
/
1996.04a
/
pp.88-96
/
1996
The characteristic analysis of fly ash generated from a fired power plant using bunker-C oil has been investigated. Ash size distribution by an optical microscopy with image processing technique, morphological shape by a scanning electron microscope(SEM) and microscope, chemical composition by the inductively coupled plasma emission spectrometry(ICP), and resistivity measurement as a function of temperature and moisture content by the resistivity meter are performed. A study of physical, chemical and electrical characteristics of bunker-C fly ash plays an important role of improving the performance of an electrostatic precipitator and protecting air pollution. The samples of bunker-C fly ash for analysis were collected from the electrostatic precipitator hopper of Ulsan Power Plant Unit 1 and Pusan Power Plant Unit 1. Mass median diameter(MMD) of bunker-C fly ash was measured 12.7${\mu}{\textrm}{m}$, while MMD of fly ash generated from the mixture of bunker-C oil(40%) and domestic anthracitic coal(60%) was 25.7${\mu}{\textrm}{m}$. The morphological structure of bunker-C fly ash consisted of fine particles of non-spherical shape. The primary chemical components of bunker-C fly ash were composed of SiO2(2.36%), Al2O3(4.91%), Fe2O3(14.33%) and C(11.84%). Resistivity of bunker-C fly ash was found to be increased with increasing temperature at the range of 100~15$0^{\circ}C$ and was measured 103~104 ohm-cm.
Journal of Advanced Marine Engineering and Technology
/
v.40
no.9
/
pp.859-867
/
2016
Bunker oil is an essential expense, and it is a high cost in ships' operations. Therefore, it forms an important part of the work shipowners do to minimize losses during operations. With bunkering disputes consistently occurring, bunker surveyors could be employed by shipowners through them and bunker survey companies signing a contract for a bunker surveyor service. Bunker surveyors could play the role of independent contractors and issue statements of fact in relation to bunkering. However, it would be impossible for bunker surveyors to immediately resolve a bunkering dispute since their role and the legal status is not clear while bunker surveys are being conducted on ships. Thus, this study sets out to define the legal status and liability of bunker surveyors and to seek an additional role for them when bunkering disputes occur.
This study performs a factor analysis that affects the bunker oil price using the Co-integration model and Vector Error Correction Model (VECM). For this purpose, we use data from Clarkson and the analysis results show 17.6% decrease in bunker oil price when the amount of crude oil production increases at 1.0%, 10.3% increase in bunker oil price when the seaborne trade volume increases at 1.0%, 1.0% decrease in bunker oil price when total volume of vessels increases at 1.0%, and 0.003% increase in bunker oil price when 1.0% increase in world GDP, respectively. This study is meaningful in that this study estimates the speed of convergence to long-term equilibrium and identifies the price adjust mechanism which naturally exists in bunker oil market. And it is expected that the future study can provide statistically more meaningful econometric results if it can obtain data during more long-periods and use more various kinds of explanatory variables.
The biodegradation experiment, the TOD analysis and the element analysis for dispersant, Bunker-C and dispersant/Bunker-C oil mixtures were conducted for the purposes of evaluating the biodegradability of dispersnat/Bunker-C oil mixtures and studying the consumption of dissolved oxygen with relation to biodegradation in the seawater. The results of biodegradation experiment showed the mixtures with $1:10{\sim}5:10$ mix ratios of dispersant to 4mg/l of Bunker-C oil to be $0.34{\sim}2.06mg/l$ of $BOD_5$ and to be $1.05{\sim}5.47mg/l$ of $BOD_{20}$ in natural seawater. The results of TOD analysis showed 1mg of Bunker-C oil to be 3.16mg of TOD. The results of element analysis showed the contents of carbon and hydrogen to be $87.3\%\;and\;11.5\%$ for Bunker-C oil, respectively, but nitrogen element was not detected in Bunker-C oil. The biodegradability of dispersant/Bunker-C oil mixture shown as the ratio of $BOD_5$/TOD was increased from $3\%\;to\;11\%$ as a mix ratio of dispersant to 4mg/l of Bunker-C oil changed from 1:10 to 5:10, and the mixtures were found to belong in the organic matter group of low-biodegradability. The deoxygenation rates($K_1$) and ultimate oxygen demands($L_o$) obtained through the biodegration experiment and Thomas slope method were found to be $0.072{\sim}0.097/day$ and $1.113{\sim}6.746mg/l$ for the mixtures with $1:10{\sim}5:10$ mix ratios of dispersant to 4mg/l of Bunker-C oil, respectively. The ultimate oxygen demand of mixture was increased as a mix ratio of dispersant to Bunker-C oil changed from 1:10 to 10:5. This means that the more dispersants are applied to the sea for Bunker-C oil cleanup, the more decreases the dissolved oxygen level in the seawater.
A marine bacterium Achromobacter sp. M-1220 was isolated from enrichment culture for emulsification of Bunker-C oil. The bacterium can emulsify approximately 7.5g of Bunker-C oil per liter in sen water medium within 1 drys at 18$^{\circ}C$ and multiply from 8$\times$10$^5$ cells to 9$\times$10$^9$ cells per mi. Optimum pH and salt concentration were pH 7.5 and 3% for the emulsification of Bunker-C oil. Emulsification takes place actively in both high sulfur-containing Bunker-C oil and high sulfur-con-taming crude oil. The amount of emulsification depends on the exogenous addition of nitrogen and phosphate sources. The bacterium can also utilize n-hexndecane, n-paraffin me benzene among the petroleum compounds as a sole carbon source.
The purpose of this study is to utilize the system dynamics to carry out a medium and long-term forecasting analysis of the bunker price. In order to secure accurate bunker price forecast, a quantitative analysis was established based on the casual loop diagram between various variables that affects bunker price. Based on various configuration variables such as crude oil price which affects crude oil consumption & production, GDP and exchange rate which influences economic changes and freight rate which is decided by supply and demand in shipping and logistic market were used in accordance with System Dynamics to forecast bunker price and then objectivity was verified through MAPEs. Based on the result of this study, bunker price is expected to rise until 2029 compared to 2016 but it will not be near the surge sighted in 2012. This study holds value in two ways. First, it supports shipping companies to efficiently manage its fleet, offering comprehensive bunker price risk management by presenting structural relationship between various variables affecting bunker price. Second, rational result derived from bunker price forecast by utilizing dynamic casual loop between various variables.
Journal of the Korean Society of Fisheries and Ocean Technology
/
v.46
no.4
/
pp.487-494
/
2010
In order to test the applicability of bunker-A in a diesel engine for small-fishing boat, the investigation of the engine performance and the exhaust emission was performed under various conditions of fuel property, intake air pressure and fuel temperature. It was also performed based on IMO NOx Technical code. At high load, the energy consumption rate of bunker-A was lower than that of diesel oil, and the characteristics of exhaust emission of bunker-A were similar to those, and NOx emission rates of both fuels satisfied the IMO NOx emission regulation limits. The energy consumption rate and characteristics of exhaust emission were improved as the intake air pressure was increased, but these were not improved remarkably as the temperature of bunker-A was heated. However, at low load the energy consumption rate, CO emission rate and HC emission rate of bunker-A were higher than those of diesel oil, but NOx emission rates of the fuels were about the same. In addition, at low load the energy consumption rate and CO emission rate of bunker-A were increased as the intake air pressure and the temperature were higher than normal conditions. Accordingly, it is thought that the use of bunker-A in a kind of test engine is possible at high load. On the other hand, it is thought that more research is needed to improve the combustion efficiency under low temperature and low load condition.
Journal of Korean Society for Atmospheric Environment
/
v.31
no.4
/
pp.368-377
/
2015
Bunker C fuel oil is a high-viscosity oil obtained from petroleum distillation as a residue. The sulfur content of bunker C fuel oil is limited to 4.0% or even lower to protect the environment. Because bunker C fuel oil is burned in a furnace or boiler for the generation of heat or used in an engine for the generation of power, carbon dioxide is emitted as a result of combustion. The objective of this study is to investigate $CO_2$ emission characteristics of bunker C fuel oil by sulfur contents. Calorific values and carbon contents of the fuels were measured using the oxygen bomb calorimeter method and the CHN elemental analysis method, respectively. Sulfur and hydrogen contents, which were used to calculate the net calorific value, were also measured and then net calorific values and $CO_2$ emission factors were determined. The results showed that hydrogen content increases and carbon content decreases by reducing sulfur contents for bunker C fuel oil with sulfur contents less than 1.0%. For sulfur contents between 1.0% and 4.0%, carbon content increases as sulfur content decreases but there is no evident variation in hydrogen content. Net calorific value increases by reducing sulfur contents. $CO_2$ emission factor, which is calculated by dividing carbon content by net calorific value, decreases as sulfur content decreases for bunker C fuel oil with sulfur contents less than 1.0% but it showed relatively constant values for sulfur contents between 1.0% and 4.0%.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.