• Title/Summary/Keyword: Bulk sampling

Search Result 63, Processing Time 0.038 seconds

Inspection and Sampling for Bulk Materials (집합체의 검사와 샘플링)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.305-309
    • /
    • 2007
  • This study introduces acceptance sampling plans and procedures for the inspection of bulk materials. This paper also presents statistical aspects of sampling bulk materials such as general principles and sampling of particulate materials.

  • PDF

An Accelerated Life Test Sampling Plan for Bulk Material (벌크재료 가속시험샘플링검사방식설계)

  • Kim Jong-Geol;Kim Dong-Cheol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.04a
    • /
    • pp.411-419
    • /
    • 2006
  • This paper aims at designing an accelerated life test sampling plan for bulk material and showing its application for an arc-welded gas pipe. It is an integrated model of the accelerated life test procedure and bulk sampling procedure. The accelerated life tests were performed by the regulation, RSD 0005 of ATS at KITECH and bulk sampling was used for acceptance. Design parameters might be total sample size(segments and increments), stress level and so on. We focus on deciding the sample size by minimizing the asymptotic variance of test statistic as well as satisfying consumer's risk under Weibull life time distribution with primary information on shape parameter.

  • PDF

A Bulk Sampling Plan for Reliability Assurance (벌크재료의 신뢰성보증을 위한 샘플링검사 방식)

  • Kim, Dong-Chul;Kim, Jong-Gurl
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.2
    • /
    • pp.123-134
    • /
    • 2007
  • This paper focuses on the in-house reliability assurance plan for the bulk materials of each company. The reliability assurance needs in essence a long time and high cost for testing the materials. In order to reduce the time and cost, accelerated life test is adopted. The bulk sampling technique was used for acceptance. Design parameters might be total sample size(segments and increments}, stress level and so on. We focus on deciding the sample size by minimizing the asymptotic variance of test statistics as well as satisfying the consumer's risk. In bulk sampling, we also induce the sample size by adapting the normal life time distribution model when the variable of the lognormal life time distribution is transformed and adapted to the model. In addition, the sample size for both the segments and increments can be induced by minimizing the asymptotic variance of test statistics of the segments and increments with consumer's risk met. We can assure the reliability of the mean life and B100p life time of the bulk materials by using the calculated minimum sample size.

High-Gain Double-Bulk Mixer in 65 nm CMOS with 830 ${\mu}W$ Power Consumption

  • Schweiger, Kurt;Zimmermann, Horst
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.457-459
    • /
    • 2010
  • A low-power down-sampling mixer in a low-power digital 65 nm CMOS technology is presented. The mixer consumes only 830 ${\mu}W$ at 1.2 V supply voltage by combining an NMOS and a PMOS mixer with cascade transistors at the output. The measured gain is (19 ${\pm}$1 dB) at frequencies between 100 MHz and 3 GHz. An IIP3 of -5.9 dBm is achieved.

Estimation and Characteristics of Atmospheric Deposition Flux of Polycyclic Aromatic Hydrocarbons (PAHs) into the Masan and Haengam Areas of Korea (마산과 행암 지역으로 유입되는 다환방향족탄화수소(PAHs)의 대기 침적 플럭스 산정과 특성)

  • Lee Su-Jeong;Moon Hyo-Bang;Choi Min-kyu
    • Journal of Environmental Science International
    • /
    • v.15 no.2
    • /
    • pp.121-131
    • /
    • 2006
  • Atmospheric bulk (wet and dry) samples were monthly collected in Masan and Heangam areas of Korea, to assess the deposition flux and seasonal variation of polycyclic aromatic hydrocarbons (PAHs). Deposition fluxes of PAHs in bulk samples were determined using gas chromatography coupled to mass spectrometer detector (GC/MSD). Particle deposition fluxes from Masan and Haengam areas varied from 13 to $87\;g/m^2/year$ and from 5 to $52\;g/m^2/year$, respectively. PAHs deposition fluxes in atmospheric bulk samples in Masan and Haengam areas ranged from 135 to $464\;{\mu}g/m^2/year$ and from 62.2 to $194\;{\mu}g/m^2/year$, respectively. Atmospheric deposition fluxes of particles and PAHs in this study were comparable to or slightly lower values than those from different locations in Korea and other countries. PAHs profiles of atmospheric deposition bulk samples showed slightly different from two sampling areas, however the predominant species of PAHs were similar. Indeno (1,2,3-c,d)pyrene, benzo(g,h,i)perylene, phenanthrene compounds were the most detected PAHs in deposition bulk samples. Carcinogenic PAHs occupied the contribution of approximately $30-40\%$ of the total PAHs deposition fluxes. The non-metric multi-dimensional scaling (MDS) was used, to assess the differentiation of PAHs source between two sampling areas. The result suggests that PAHs contamination sources were different according to the location and season surveyed. There was no an apparent relationship between the PAHs deposition flux against temperature and rainfall amount, even though summer season with the highest temperature and the largest amount of precipitation showed the lowest PAHs deposition flux. Benzo(e)pyrene/benzo(a)pyrene ratio indicated that the photo-degradation process was one of important factors to the seasonal variation of PAHs with the lower deposition fluxes.

The Study of Improvement of Measurement Precision on Bulk Density, Soil Hardness and Air Permeability in Upland Soils

  • Ok, Jung-hun;Han, Kyung-hwa;Cho, Hee-rae;Zhang, Yong-seon;Seo, Young-ho;Jung, Kang-ho;Lee, Hyub-sung;Kim, Gi-sun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.5
    • /
    • pp.482-488
    • /
    • 2017
  • The measurement based on reliable standard operating procedures (SOPs) is important for consistent information. The objective of this study is to investigate reliable SOPs of soil physical methods, including core method for bulk density, Yamanaka hardness, and air permeameter method for air permeability. The coefficients of variation in bulk density (core method), Yamanaka hardness, and air permeability were ranged of 1~6%, 8~13%, and 10~84%, respectively. The variation in situ measurement such as bulk density, hardness, and air permeability due to spatial variability at measuring site was larger due to the number of replicates, organic matter content, and soil texture. Nevertheless, air permeability had different values as different number of replicates, and thus, it is thought that more replicates can result in higher reliability. It suggested that investigation of soil physical properties for the target sites should required to consider about soil texture, organic matter content, and number of replications before measurement. In conclusion, core sampling for bulk density measurement in upland soil recommended to perform in 3 repetitions with 2 inch core, and 3 inch core sampling for higher organic matter content.

Condition assessment of raking damaged bulk carriers under vertical bending moments

  • Kim, Do Kyun;Yub, Su Young;Choi, Han Suk
    • Structural Engineering and Mechanics
    • /
    • v.46 no.5
    • /
    • pp.629-644
    • /
    • 2013
  • This paper concerns about the raking damages on the ultimate residual hull girder strength of bulk carriers by applying the modified R-D diagram (advanced method). The limited raking damage scenarios, based on the IMO's probability density function of grounding accidents, were carried out by using sampling technique. Recently, innovative method for the evaluation of the structural condition assessment, which covers the residual strength and damage index diagram (R-D diagram), was proposed by Paik et al. (2012). This concept is applied in the present study and modified R-D diagram, which can be considered vessel size effect, is then proposed. Four different types of bulk carrier structures, i.e., Handysize (37K), Supramax (57K), Kamsarmax (82K) and Capesize (181K) by Common Structural Rule (CSR), were applied to draw the general tendency. The ALPS/HULL, intelligent supersize finite element method, was employed for the ultimate longitudinal strength analysis. The obtained empirical formulas will be useful for the condition assessment of bulk carrier structures. It can also cover different sizes of the bulk carriers in terms of ultimate longitudinal strength. Important insights and findings with useful guidelines developed in this study are summarized.

The Third-generation Synchrotron Radiation Technique for Single Particle Analysis

  • Ma, Chang-Jln
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.49-50
    • /
    • 2003
  • To know the properties of single aerosol particle is an essential prerequisite for understanding its chemical reactions in the atmosphere. Single particle analysis has the advantage of providing a great amount of information that cannot otherwise be obtained using methods of bulk analysis. And single particle analysis needs the short sampling time and the small sampling mass for analysis. This allows for a better determination of the temporal variation of the component concentrations in aerosol particles. (omitted)

  • PDF

A study on the Analysis Method and Pollution Measure of existed VOCs during the Bulk Liquid Cargo Operation at Vessels (산적 액체 화물 작업중 배출되는 VOCs 분석방법 및 오염 측정 연구)

  • Cheong, Kwang-Hyun;Lee, In-Ho
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.21-26
    • /
    • 2007
  • The Protocol adopted in Sep. 1997 included the new Annex VI of MARPOL 73/78, which entered into force on 19 May 2005. Revision for the accept MARPOL Annex VI with make public on 29 Dec. 2005 and enforce on 29 Jun. 2006. For all that not installation at oil terminal or if installed do not used. The purpose of this study is to research and evaluate the methods of sampling and analysis, and the pollution measure of existed VOCs during the bulk liquid cargo operation at vessels. As the sampling instrument of VOCs, Tedlar bag has the effect of decrease in concentration by the chemical reaction and absorption, and the method using the solvent extraction has error cause because of the extraction, the absorption tube has error by the breakthrough. But canister is the best sampling instrument because of having no sampling mistake. The study on VOCs emission is not sufficient for the research on the pollution cause and the analysis data on the HAP during the bulk liquid cargo operation at vessels. Hence, monitoring on the management hazardous VOCs need to be continued during the cargo operation at vessels and VOCs management field must be study for the make progress at a good pace for reason of crew's health.

  • PDF

Diurnal Variations in Milk and Blood Urea Nitrogen and Whole Blood Ammonia Nitrogen in Dairy Cows

  • Hwang, Sen-Yuan;Lee, Mei-Ju;Peh, Huo-Cheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.12
    • /
    • pp.1683-1689
    • /
    • 2001
  • The levels of urea nitrogen both in blood (BUN) and milk (MUN), and milk protein (MP) reflect protein and energy intake in dairy herd feeding. Blood and milk constituents may be changes rhythmically and influence by different sampling time within a day and after feeding. Trials were conducted using five dietary treatments in both lactating and dry cows to study the effects of sampling time on concentrations of BUN, MUN and whole blood ammonia nitrogen (BAN) in practical dairy cow feeding in Taiwan. The conventional feed ingredients and forages including corn silage, alfalfa hay, timothy or pangola hay and corn grain were used as major source of the diet to follow practical dairy cow feeding. Five different diets were varying in amounts (low=L; standard=S; high=H) of crude protein (P) and energy (E) according to the NRC (1989). The energy to protein ratios in kcal/kg for the PSES, PLES, PHES, PSEH and PSEL were 10.82, 12.54, 9.41, 12.53 and 9.13 in lactating cows, and 11.38, 13.33, 9.78, 13.28 and 9.74 in dry cows, respectively. Results showed that after feeding at 9:30, BUN reached peak at 13:30 and was significantly higher than those to that sampled at 14:30 to 18:30 (p<0.05) in dry cows. Therefore the best blood sampling time for urea nitrogen assay in dry cows is 4 hours after morning feeding. In lactating cows, BUN of 13:30 was significantly higher than those of 8:30 to 11:30 (p<0.05), but there were no significant difference between the BUN values of other sampling time. Hence the suitable blood sampling time for BUN value in lactating cows was located on 3 to 8 hours after morning feeding, but the best time was 4 hours after morning feeding. MUN content is significantly higher in the afternoon collected bulk milk than the fore-strip morning milk (p<0.05), therefore the best sampling time for MUN is from afternoon collected bulk milk. Diurnal BAN changed without traceable rhythmic pattern and was negatively correlated to the BUN (r = -0.78). It is suggested that BAN may not be a good indicator for monitoring dairy cow feeding.