• Title/Summary/Keyword: Building use

Search Result 4,945, Processing Time 0.031 seconds

The Pedestrian Integrated Circulation System in Mixed-use Building based on User Behavior (이용자 행태 기반 복합건축 보행자 통합동선계획)

  • Lee, Jin-Kyoung;Kim, Chan-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.12
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of the study is to be the pedestrian integrated circulation system of malling route and the third route in Mixed-use Building based on User Behavior. The study has performed by the following approaches: Initially, literature reviews are performed related to a pedestrian route by user in mixed-use building. Second, general and stroller users moving route are analyzed based on the outcome of the case study. Finally, the study develops the efficient pedestrian integrated circulation system of malling route and the third route in Mixed-use Building. According to the study, the following conclusions were made: First, An integrated plan for escalators and EVs, which are accessible to both users and strollers, is needed. Second, The entrance automatic door and circulation elements should be connected for continuous move by the stroller users. Finally, The circulation system of complex buildings should be a simple spatial structure and route plan that users can easily recognize.

A Study on the Improvement Direction of Housing Use Classification in Korea (우리나라 주택용도분류체계 개선 방향 연구)

  • Hwang, Eun-Kyoung;Lee, Seong-Ok;Kim, Soo-Am
    • Journal of architectural history
    • /
    • v.22 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • Because of the demographic and economic changes and the lifestyle diversification, the new housing types such as the Quasi-housing and urban small-size multi-unit housing are appeared in korea. The current housing use classifications are regulated in accordance with the housing divided ownership, horizontal and vertical size of housing, and the number of units. However, there is a limit to accommodate the new housing type. Therefore, this study proposed the direction of improvement of the housing use classifications through comparative analysis of foreign housing use classifications. Also, building regulations are applied according to the building use classifications. Therefore, the new housing types in building act are very urgent and important. So this study is derived the problems of the current housing use classifications and is proposed the improvement direction of it through the expert opinion survey.

A Proposal of Planning Direction of Eco-Friendly Multi-Use Housing and Commercial Complex (주상복합건물의 환경친화적 계획방향에 관한 기초 연구)

  • Lee, Eun Jung;Park, Myung Kyug;Park, Young Ki
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • Multi-use housing and commercial buildings have been emerged according to social and economic changes of CBD in Seoul Metropolitan Areas. The purpose of this study is to clarify the characteristics of the multi-use building, to analyze the problems on the base of survey and to suggest the solutions for architectural planning, focusing on eco-friendly dwelling environment. A field survey with 46 subjects has been carried out with structured questionnaire. Some problems in planning of the complex building have been discussed in terms of environmental issues and design criteria. In conclusion, basic planning directions for improving the building environmental quality have been suggested.

A study on the quality improvement plan of recycled aggregate concrete for the use of building materials (건축자재 활용을 위한 순환골재 콘크리트의 품질개선 방안 연구)

  • Kim, Tae-Hyun;Hong, Sung-In;Choi, Yun-Jeong;An, Jae-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.162-163
    • /
    • 2022
  • Recycled aggregate has structural limitations in that it cannot be actively used for use as a structural building material due to quality deviations such as increase in cracks, decrease in constructability during in-situ casting, and decrease in strength. Although the government gives incentives to use recycled aggregate concrete for major structural parts of buildings to revitalize recycled aggregate concrete, there is a perception that the quality control of recycled aggregate producers that produce raw materials is insufficient. In this study, recycled aggregate, I checked the quality of the company that handles the quality. We are working on this.

  • PDF

Prediction of City-Scale Building Energy and Emissions: Toward Sustainable Cities

  • KIM, Dong-Soo;Srinivasan, Ravi S.
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.723-727
    • /
    • 2015
  • Building energy use estimation relies on building characteristics, its energy systems, occupants, and weather. Energy estimation of new buildings is considerably an easy task when compared to modeling existing buildings as they require calibration with actual data. Particularly, when energy estimation of existing building stock is warranted at a city-scale, the problem is exacerbated owing to lack of construction drawings and other engineering specifications. However, as collection of buildings and other infrastructure constitute cities, such predictions are a necessary component of developing and maintaining sustainable cities. This paper uses Artificial Neural Network techniques to predict electricity consumption for residential buildings situated in the City of Gainesville, Florida. With the use of 32,813 samples of data vectors that comprise of building floor area, built year, number of stories, and range of monthly energy consumption, this paper extends the prediction to environmental impact assessment of electricity usage at the urban-scale. Among others, one of the applications of the proposed model discussed in this paper is the study of urban scale Life Cycle Assessment, and other decisions related to creating sustainable cities.

  • PDF

A Basic Study on the Fire Risk by Building Use based Growth Fire Statistics (성장화재통계 기반 건축물 용도별 화재위험도에 관한 기초연구)

  • Seo, Dong-Goo;Lee, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.218-219
    • /
    • 2020
  • The risk of a fire in a building is closely related to the usage of the building. In particular, all fires that occur in a building are not risky to safety of human life, and it is associated with the combustion area and the increase of total floor area of the building. Therefore, this study focused on safety of human life in terms of the statistics of fire with considering the aspect of growing fires and analyzed the statistical data of fire for 10 years. As for the analysis on fire, the time of occurrence by usages of buildings, frequency of occurrence and the ratio of casualties etc. were analyzed. It is expected that results of this study could be used for evaluations on a variety of parts in terms of design, construction and maintenance of buildings.

  • PDF

Emergy-Simulation Based Building Retrofit

  • Hwang, Yi
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.5-13
    • /
    • 2014
  • This paper introduces emergy(spelled with "m") that is a new environmental indicator in architecture, aiming to clarify conflicting claims of building design components in the process of energy-retrofit. Much of design practitioners' attention on low energy use in operational phases, may simply shift the lowered environmental impact within the building boundary to large consumption of energy in another area. Specifically, building energy reduction strategies without a holistic view starting from natural formation, may lead to the depletion of non-renewable geobiological sources (e.g. minerals, fossil fuels, etc.), which leaves a building with an isolated energy-efficient object. Therefore, to overcome the narrow outlook, this research discusses the total ecological impact of a building which embraces all process energy as well as environmental cost represented by emergy. A case study has been conducted to explore emergy-driven design work. In comparison with operational energy-driven scenarios, the results elucidate how energy and emergy-oriented decision-making bring about different design results, and quantify building components' emergy contribution in the end. An average-size ($101.9m^2$) single family house located in South Korea was sampled as a benchmark case, and the analysis of energy and material use was conducted for establishment of the baseline. Adoption of the small building is effective for the goal of study since this research intends to measure environmental impact according to variation of passive design elements (windows size, building orientation, wall materials) with new metric (emergy) regardless of mechanical systems. Performance simulations of operational energy were developed and analyzed separately from the calculation of emergy magnitudes in building construction, and then the total emergy demand of each proposed design was evaluated. Emergy synthesis results verify that the least operational energy scenario requires greater investment in indirect energy in construction, which clearly reveals that efficiency gains are likely to be overwhelmed by increment of material flows. This result places importance on consideration of indirect energy use underscoring necessity of emergy evaluation towards the environment-friendly building in broader sense.

A Survey on Operating State of ISWTP according to Building Use Type (건물용도에 따른 개별오수처리시설의 운영실태에 관한 연구)

  • Gwon, Eun-Mi;Kim, Jong-Seok;Chung, Wook-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.337-341
    • /
    • 2005
  • It is difficult to use average sewage water quality as a design parameter for the individual sewage wastewater treatment plant(ISWTP), because sewage water quality is very various according to the building use type. So, in this study, we estimated daily, seasonal and weekly trend of sewage water quality and flow rate in various kind of building to comprehend operating state of ISWTP. The sewage water quality and flow rate were higher in the business building than household building. The seasonal difference of the water quality was not detected but that of flow rate was high. The flow rate of the sewage in the business building was higher in summer than in other seasons and in weekend than in weekday. The treatment efficiency of IWSTP was about $70{\sim}80%$ with BOD, $40{\sim}50%$ with TN and TP, which was very low. The unit loads of the individual house were 36.05 gpcd with BOD, 37.91 gpcd with SS, 23.91 gpcd with T-N, and 7.90 gpcd with T-P respectively, and those values were higher than other studies. It is because, as distinct from other studies, sewage water quality was monitored at the inlet point of the IWSTP in this study. We can use this results as an one of basic parameters for the design of IWSTP.

The Advanced Case Study for Investigation on Application of BIPV on Tall Building (초고층빌딩의 BIPV 적용성 검토를 위한 선진 사례 조사)

  • Lee, Jong-Min;Seok, Ho-Tae;Yang, Jeong-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.155-160
    • /
    • 2009
  • The increasingly high prices for oil, the exhaustion of fossil fuels as well as concern about global warming are driving rapid growth of alternative sources of energy in the world. The active solution for global environment and exhaustion of energy sources is to develop and popularize the technologies to use natural energy such as sunlight, wind, and water. PV(Photovoltaic) modules are efficient devices that has been considered a logical material for use in buildings. Recent advanced BIPV(Building Integrated PV) technology have rapidly made PVs suitable for direct integration into construction in the world. Recently, building has been higher and higher. Tall buildings have many advantages for BIPV such as wide facade area and no shading effect by the surrounding buildings. However. BIPV has not been applied for tall building facade yet. Therefore, the purpose of the research is to develop suitable BIPV for tall buildings and to put these technologies to practical use. Therefore, the purpose of the study is to investigate unification of BIPV to curtain wall to apply BIPV on tall building through research into advanced application of overseas BIPV cases.

  • PDF

An Analysis on the Energy Consumption Unit of the Public buildings in Daegu (대구시 공공건축물의 에너지 소비 원단위에 관한 연구)

  • Choe, Jeong-Hui;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.319-322
    • /
    • 2005
  • An energy problem has become one of the many Problems awaiting solution to human society. Energy needs to support not only industry, but also building in city. The types of residential building, office building and public building account for much proportion among the totally amount used energy. A public institution shows a fine example for an energy conservation in the present situation. But, the amount used energy of electricity, air-conditioning and heating is different from a building use and condition. Because the building data of the energy consumption by a load is insufficient, it is unable to select a proper energy source. According to this study, it analyzed an energy load by each building that had investigated the actual conditions of energy consumption about public buildings in Daegu City. In order to plan the efficient energy use both existing buildings and new buildings, this study will present the efficient energy use plan, which has operated to new buildings of a public institution, at present.

  • PDF