• Title/Summary/Keyword: Building regulations

Search Result 523, Processing Time 0.022 seconds

The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling (사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석)

  • Choi, Seon woo;Kim, Ji Yeon;Park, Hyo soon;Kim, Jun Tae
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.

A Study on the Improvement of Building Administration by Local Government (지방자치단체 건축행정 개선방안에 관한 연구)

  • Kim, Min-Ji;Ryu, Su-Yeon;Cho, Young-Jin;Yu, Kwang-Heum
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.3-11
    • /
    • 2017
  • The non-mandatory guidance and illogical ordinance of local government generate complicated and vague regulations and procedures. These cause inconvenience in building administration, and give rise to unnecessary social and administrative expenses. The purpose of this study is to suggest the improvement of building administration by local government from an institutional point of view through the literature review and the specialist survey focusing on the problems arising from the building ordinances and non-mandatory guidance. The results of this study are as follows; In the first place, the connection between law and ordinance should be improved in a systematic, definitude manner and high-degree of completion. Second, the monitoring management system should be arranged in order to excavate and improve the non-mandatory guidance. Third, the effort should go into improving ability and disposition of building official. Fourth, it is necessary to materialize and clarify the regulatory contents and adjust them to fit the legal system. Lastly, it is important to reinforce incentives and procedures of verification in order to manage building ordinances of legal government's own free will. In order to improve of building administration by local government, it is necessary to make the structure of sustainable improvement and discuss not only institutional aspect but also elements of building administration in later study.

Prevalence and Predictors of Support for the Implementation of Smoke-free Regulations in the Home Environment among Residents of Multi-unit Housing in Seoul (서울시내 공동주택 거주자의 주거환경 내 금연정책 시행에 대한 지지와 영향요인)

  • Kim, Jeonghoon;Lee, Kiyoung;Kim, KyooSang
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.130-142
    • /
    • 2017
  • Objectives: Although the Korean government is able to implement smoke-free regulations for shared areas in multi-unit housing (MUH), such regulations are limited for private homes. The purpose of this study was to determine the prevalence and predictors of support for the implementation of smoke-free regulations for homes and near the outsides of building among residents in MUH. Methods: A population-based sample of 2,600 residents among a web-based panel in Seoul was included. The residents completed questionnaires including smoking status, voluntary smoke-free home rules, and support for the implementation of smoke-free regulations for homes and near the outsides of building. The presence of a voluntary smoke-free home rule was determined when residents declared that no one smoked inside their homes. Results: Among the 2,600 MUH residents, prevalence of support for the implementation of smoke-free regulations for homes was higher (83.2%) than for near the outsides of buildings (75.1%). Support for the implementation of smoke-free regulations for homes was higher when residents were non-smokers, had voluntary smoke-free home rules, lived with children, lived with more residents, lived in owned homes, lived in apartments, and lived in homes with more frequent secondhand smoke (SHS) incursion. Support for the implementation of smoke-free regulations near the outsides of buildings was higher when residents were women, non-smokers, more educated, had a voluntary smoke-free home rule, lived with children, lived in homes with more frequent SHS incursion, and lived in a commercial area. Conclusions: The majority was supportive of the implementation of smoke-free regulations for homes. Predictors identified in the study can be useful for promoting implementation of smoke-free regulations for homes in MUH.

Proposal of Legislation of Smoke Compartment for Prevention and Control of Smoke Diffusion in Buildings (건축물의 연기확산 방지 및 제어를 위한 방연구획의 법제화 제안)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Kim, Hye-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.96-97
    • /
    • 2019
  • According to building law, there are only regulations on the fire prevention compartments that can perform the function of partial smoke compartment, but the building law management of the smoke compartment for effective smoke diffusion prevention and control is not possible. The lack of control on the smoke compartment such as leakage rate on the penetrating part, and the lack of leakage rate in the design of smoke control of fire safety law resulted in the absence of fundamental safety technology. Therefore, this study seeks to find solutions to domestic problems after reviewing relevant domestic laws and regulations.

  • PDF

A Study on the Height Limitation of a Building in Building Law - Focusing on the Standard of the Ground Level Calculation - (건축법(建築法)에서의 건축물(建築物) 높이제한규정(制限規定) - 지표면산정기준(地表面算定基準)을 중심(中心)으로 -)

  • Kim, Soo-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.29-38
    • /
    • 2003
  • The articles on building height limitation are very important to form buildings to be. The application of the articles is based on the surface of the building site ground, that is, the definite judgment of ground level should ensure the correctness of building height limitation. This study surveyed the recognition degree of practitioners about the building height limitation regulations by questionnaires, and analyzed its results and compared them to related building laws and letter of reply from the office to practitioners' inquiry on related regulation. The study summarized the results as follows; 1. It is not clear to judge the ground level. Especially in cases of pilotis structure, there would be various interpretations to define its ground level. 2. According to present building regulations, the site would be confused to define by practitioners whether it is stiff or plain. 3. In case of regulation of a right to enjoy sunshine, it is hard to calculate the average horizontal level(ground level) with neighboring sites. 4. If there were a manual with illustrations for judging and calculating the ground level of various cases, civil petitions would be reduced.

  • PDF

Comparison of Domestic and Foreign Standard Specifications on Form Design (국내외 표준 시방서의 거푸집 설계 관련 규정의 비교)

  • Jeon, Kyu-Nam;Choi, Sung-Yong;Baek, Dae-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.29-31
    • /
    • 2010
  • This study investigated the typical standards of B kind of standard specification related to home and abroad forms design and compared them, and the results can be summarized as follows. In case of domestic standards, regulations on most forms design was described relatively in detail. and in case of CTEA among them, it included detailed contents of load conditions, lifting and subsidence. In case of abroad standards, the design regulations are only simply mentioned, not in detail, in ACI, CEB-FIP and BS, and JCI and JASS were similar to domestic KCI and KASS regulations. As to structural calculation in forms design regulations, most of domestic regulations included detailed matters on structural calculation, among them, CTEA shows the most detailed matters on it. On the other hand, it could be known that in case of abroad standards, most standards do not include matters on structural calculation except ACI, JCI and JASS.

  • PDF

High-rise buildings in the general direction of the Fire Safety Management Study (초고층 건축물 소방안전관리의 기본방향에 관한 연구)

  • Choe, Man-Cheol;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.79-93
    • /
    • 2011
  • Unlike a general building high-rise buildings itself has a kind of risk. In this study, the risk of a number of high-rise buildings have fire safety management of the particular risks associated with looking for ways to minimize focused. Theoretical Study of the United States since the collapse of the WTC buildings, and be the center of the authentic country was. outside of the high-rise building fire safety and related issues, and measures were based on the theory of reference. Issues include voluntary arson. disaster management, building codes and fire regulations of the discrepancies, such as fire safety aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high-rise buildings. Although differences of opinion between departments will not be easy to fire and building regulations regarding conflicts of laws among other things, require immediate resolution, and high-rise buildings to create a standard for effective crisis management manual countermeasures will also be ensured.

  • PDF

Accident Prevention and System Improvement Strategies for small and medium-sized construction sites (중소규모 건설현장 재해원인 분석 및 제도적 개선방안)

  • Yi, Kyoo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.3
    • /
    • pp.59-64
    • /
    • 2009
  • This study is to analyse the causes of accident in small and medium-sized construction sites and to provide prevention strategies and system improvement guidance. Although occupational safety and health act regulates the standards and installations of temporary structures, about an half of construction accidents were caused by poor temporary structures such as guardrails, scaffolds, work platforms, etc. It investigated 51 construction sites which is located in metropolitan area by asking a series of questions including their knowledge about regulations and opinions about prevention strategies. The result shows that many of the respondents do not have sufficient understandings about the regulations, and it implies that education and training must be reinforced in order to enhance the safety-awareness and to develop the comprehension of regulations.

Basic Research for Reducing Fine Dust in Urban Construction Sites Using Water Fog (미분무수를 활용한 도심지 건설현장 미세먼지 저감을 위한 기초연구)

  • Han, Jae Goo;Kim, Young Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.209-210
    • /
    • 2019
  • This paper investigates and analyzes related systems, policies, and research trends that are used to prepare the operating regulations for drone-based fine dust monitoring and water fog injection systems in small-sized construction site. As a result of the study, we have drawn a total of six major items to consider when drafting the drone related operational regulations. It will also be used as a basis for future development system operation regulations.

  • PDF