• Title/Summary/Keyword: Building Performance

Search Result 6,355, Processing Time 0.03 seconds

A Basic Study of Legal Standards for Building Health Performance (건축물의 건강성능에 관한 법적 기준의 기초연구)

  • Lee, Hyun-Min;Ryu, Sang-Yeon;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.19-26
    • /
    • 2009
  • In modern architecture, the air-tight construction aimed at saving the energy rather causes ventilation problems and the artificial materials for cost reduction worsen the residential quality. To deal with such negative effect, the study on evaluating the health performance becomes increasingly critical. Among the various factors such as design quality, selected material, construction method and mechanical system that shall be subject to evaluation to identify the health performance of the building, the study was aimed at investigating the legal standards associated with healthy building in various countries. Such evaluation items will provide inputs for an attempt to build legal criteria for a building health performance rating system in Korea.

A Study on the Protection of Smoke Control Performance in Building Enclosure to Prevent the Expansion of Smoke in Fire (화재시 연기확대 방지를 위한 건축물 구획공간에서의 방연성능 확보에 관한 조사 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.91-92
    • /
    • 2019
  • In case of fire in a compartmentalized building area, a number of casualties are caused by smoke production. Accordingly, openings, penetrations and joints in compartmentalized spaces should be secured not only for fire resistance but also for smoke-proofing. However, domestic test regulations stipulate test methods for refractory performance of penetrations and joints, but do not specify separate deferral performance. In the case of openings, the test for the smoke performance exists at room temperature, but the smoke performance at high temperature is not secured, so countermeasures are needed.

  • PDF

A Study on the Improvement of Inspection System for Building Maintenance (건축물 유지관리점검 체계화를 위한 제도 개선방안)

  • Yu, Kwang-Heum;Kim, Min-Ji
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.10
    • /
    • pp.63-73
    • /
    • 2018
  • As the life cycle of buildings is expected to increase, new constructions will decrease and the proportion of remodeling and repair will increase. Therefore, there is an increasing need for overall performance management of old buildings. In 2020, the proportion of buildings over 30 years old is expected to reach a half. As a result, the demand for securing and improving the performance in the stage of using the building is increasing due to the change in the demand for the building, such as the decrease in the construction permit and the increase in the use of the existing building. From this perspective, the study sought to consider institutional measures to organize the preventive and conservative maintenance of buildings. For this purpose, the conceptual goals of inspection for building maintenance were set through a literature review, and the status and problems associated with building maintenance were analyzed to suggest ways to improve the inspection system for building maintenance.

A Study on the Performance Increase in Building Energy Technology according to the Korea's Zero Energy Building Policy (한국의 제로에너지건축 정책 추진에 따른 건축물 에너지기술 성능 연구)

  • Shim, Hong-Souk;Lee, Sungjoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.543-553
    • /
    • 2021
  • As a key policy for achieving the goal of reducing GHG in the building sector, Korea has enforced the mandatory certification of zero-energy buildings for new buildings in the public sector from 2020. This study evaluated a policy to achieve Net Zero by identifying the trend of changes in building energy performance according to policy and presenting a methodology to analyze the current performance state of energy technology applied to buildings. The final goal was to help stakeholders apply appropriate energy technologies for new buildings. For this study, data collected on building energy efficiency certification over the last four years have shown a gradual increase in energy performance. In addition, K-means cluster analysis was used to analyze the performance status of energy technologies applied to buildings. The high and low clusters of education and office facilities were used to analyze the comparative group (2016-2020, 2020). As a result, the solar module area in both high and low clusters of education facilities increased by 261.1% and 283.5%. In contrast, the solar module area decreased by both high and low clusters of office facilities. The most passive and active technologies showed an increase in energy performance.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

The experimental study on the Evaluation of fire-proof performance and bond characteristics for development of 3hours Fire-Proof paint (3시간 내화도료의 개발을 위한 내화성능 및 부착특성 평가에 관한 실험적 연구)

  • Kim, Soo-Young;Kim, sung-kil;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.63-64
    • /
    • 2012
  • Recently, Fire-proof performance of buildings becomes important to ensure safety. As a result, fire-proof paint is required for 3 hours. However, Experiments are only performed by standard KS F 2271 for estimation of fire-proof paint. Because there is no domestic estimation standard for performance of fire-proof paint as well. So estimation standard of fire-proof paint is needed to guarantee their performance for establishing quality system and to assure same performance for safety of people in the building from unpredicted fire accident. Owing to these reasons, we studied comparative estimation for quality performance of two kinds of fire-proof paint and bond performance.

  • PDF

Seismic performance of RC buildings subjected to past earthquakes in Turkey

  • Inel, Mehmet;Meral, Emrah
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.483-503
    • /
    • 2016
  • This study aims to evaluate seismic performance of existing low and mid-rise reinforced concrete buildings by comparing their displacement capacities and displacement demands under selected ground motions experienced in Turkey as well as demand spectrum provided in 2007 Turkish Earthquake Code for design earthquake with 10% probability of exceedance in 50 years for soil class Z3. It should be noted that typical residential buildings are designed according to demand spectrum of 10% probability of exceedance in 50 years. Three RC building sets as 2-, 4- and 7-story, are selected to represent reference low-and mid-rise buildings located in the high seismicity region of Turkey. The selected buildings are typical beam-column RC frame buildings with no shear walls. The outcomes of detailed field and archive investigation including approximately 500 real residential RC buildings established building models to reflect existing building stock. Total of 72 3-D building models are constructed from the reference buildings to include the effects of some properties such as structural irregularities, concrete strength, seismic codes, structural deficiencies, transverse reinforcement detailing, and number of story on seismic performance of low and mid-rise RC buildings. Capacity curves of building sets are obtained by nonlinear static analyses conducted in two principal directions, resulting in 144 models. The inelastic dynamic characteristics are represented by "equivalent" Single-Degree-of- Freedom (ESDOF) systems using obtained capacity curves of buildings. Nonlinear time history analysis is used to estimate displacement demands of representative building models idealized with (ESDOF) systems subjected to the selected ground motion records from past earthquakes in Turkey. The results show that the significant number of pre-modern code 4- and 7-story buildings exceeds LS performance level while the modern code 4- and 7-story buildings have better performances. The findings obviously indicate the existence of destructive earthquakes especially for 4- and 7-story buildings. Significant improvements in the performance of the buildings per modern code are also obvious in the study. Almost one third of pre-modern code buildings is exceeding LS level during records in the past earthquakes. This observation also supports the building damages experienced in the past earthquake events in Turkey.

Impact by Estimation Error of Hourly Horizontal Global Solar Radiation Models on Building Energy Performance Analysis on Building Energy Performance Analysis

  • Kim, Kee Han;Oh, John Kie-Whan
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.3-10
    • /
    • 2014
  • Impact by estimation error of hourly horizontal global solar radiation in a weather file on building energy performance was investigated in this study. There are a number of weather parameters in a given weather file, such as dry-bulb, wet-bulb, dew-point temperatures; wind speed and direction; station pressure; and solar radiation. Most of them except for solar radiation can be easily obtained from weather stations located on the sites worldwide. However, most weather stations, also including the ones in South Korea, do not measure solar radiation because the measuring equipment for solar radiation is expensive and difficult to maintain. For this reason, many researchers have studied solar radiation estimation models and suggested to apply them to predict solar radiation for different weather stations in South Korea, where the solar radiation is not measured. However, only a few studies have been conducted to identify the impact caused by estimation errors of various solar radiation models on building energy performance analysis. Therefore, four different weather files using different horizontal global solar radiation data, one using measured global solar radiation, and the other three using estimated global solar radiation models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM) were packed into TRY formatted weather files in this study. These were then used for office building energy simulations to compare their energy consumptions, and the results showed that there were differences in the energy consumptions due to these four different solar radiation data. Additionally, it was found that using hourly solar radiation from the estimation models, which had a similar hourly tendency with the hourly measured solar radiation, was the most important key for precise building energy simulation analysis rather than using the solar models that had the best of the monthly or yearly statistical indices.

A Study on the Service life of the Building Components in the Apartment Housing (공동주택 구성재의 내용년수 산정방법에 관한 연구)

  • Lee Kang-Hee;Chang Jung-Hee;Chae Chang-U
    • Journal of the Korean housing association
    • /
    • v.16 no.5
    • /
    • pp.67-74
    • /
    • 2005
  • The performance of building should be deteriorated with time while the building would maintain and manage the function and performance to get a living condition. For the efficient maintenance of the building, the repair cycle would be provided and applied during the service-life time. The service-life time of the building components would be needed to determine the repair time and the repair scope. The service-life time of the building components would be calculated with the 1st repair time and the recovery rate of the performance, considering the recovery rate after repaired. In this paper, the 1st repair time would be estimated with the normal probability distribution, choice probability and 3rd quadratic function. The recovery rate of the building components assumes various level according to the research target and utility area. The results of this study are as follows ; first, most of the components of the building work would range about 30 years in the service-life time and the components of the mechanical works range from 28 years to 37 years, those of the electrical works would be about 31 years.