A Study on the Innovation of an Office Space by Post Occupancy Evaluation (거주후평가(P.O.E)에 의한 오피스공간의 개선방안에 관한 연구)

  • 한혜련
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.188-194
    • /
    • 2001
  • Increasing the user's need in the building facilities, the architects, engineers, and building managers must consider the user's opinion when they plan and construct the buildings. When planning and managing of the buildings, accepting the user's opinion is desirable and indispensible to solve the Problems about the architectural facilities between suppliers and users. To supply the efficient working environments, use the check listing tools and operate the post occupancy evaluation. The real estate and development company is selected for the evaluation. It is renovated in 2000 to fit in its working environment. The process of the evaluation is proceeded both private and group working spaces and facility and management of the buildings with 10 categories. Following the result of Post occupancy evaluation, the users of the building are mostly satisfied with their working environments after the renovation. However, the categories in thermal environment and indoor air and supply for office work need to be improved in advance.

  • PDF

Deep Learning-Based Occupancy Detection and Visualization for Architecture and Urban Data - Towards Augmented Reality and GIS Integration for Improved Safety and Emergency Response Modeling - (건물 내 재실자 감지 및 시각화를 위한 딥러닝 모델 - 증강현실 및 GIS 통합을 통한 안전 및 비상 대응 개선모델 프로토타이핑 -)

  • Shin, Dongyoun
    • Journal of KIBIM
    • /
    • v.13 no.2
    • /
    • pp.29-36
    • /
    • 2023
  • This study explores the potential of utilizing video-based data analysis and machine learning techniques to estimate the number of occupants within a building. The research methodology involves developing a sophisticated counting system capable of detecting and tracking individuals' entry and exit patterns. The proposed method demonstrates promising results in various scenarios; however, it also identifies the need for improvements in camera performance and external environmental conditions, such as lighting. The study emphasizes the significance of incorporating machine learning in architectural and urban planning applications, offering valuable insights for the field. In conclusion, the research calls for further investigation to address the limitations and enhance the system's accuracy, ultimately contributing to the development of a more robust and reliable solution for building occupancy estimation.

Validating a Building Prototype: A Post-Occupancy Evaluation of a Women's Medical Center (여성전문병원의 거주후 평가에 관한 연구)

  • Lee, Hyung-Sook;Shepley, Mardelle McCuskey
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.4 no.6
    • /
    • pp.95-102
    • /
    • 1998
  • The validity of new building prototypes must be confirmed to support the design process for comparable future projects. This project invovled a post-occupancy study at a new women's health center that provides LDR/P (labor, delivery, recovery, postpartum). The study's objectives were to test whether the intentions of the designers were effectively executed, to provide feedback to the hospital about the new facility, and to provide design guidelines.

  • PDF

Operating Mode of Thermally Activated Building System (TABS) for Residential Buildings According to their Cooling Load Profile (주거건물의 냉방 부하 패턴에 따른 구체축열시스템 운전 방안)

  • Park, Sang-Hoon;Yeo, Myoung-Souk;Yoo, Mi-Hye;Lee, Yu-Ji;Chung, Woong-June;Kim, Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.23 no.2
    • /
    • pp.99-106
    • /
    • 2012
  • Compared to Packaged Terminal Air Conditioning Systems, Radiant Cooling Systems have the advantage of energy saving and thermal comfort. Thermally Activated Building System (TABS) is one of the radiant heating and cooling systems. The main difference between TABS and other radiant systems lies in the usage of the time-lag effect of storing heat energy in the concrete. Current energy usage in summer time is concentrated within a specific time by using Packaged Terminal Air-Conditioner (PTAC). Due to the time-lag effect of TABS, energy usage can be distributed to other time zones. To maximize this effect, it is important to determine the appropriate operating mode, which for TABS is dependent upon the cooling load generated by the occupancy schedule. In this study, occupancy schedules are determined for various residential types. The operating modes of TABS for these residential types are estimated by using a dynamic computational simulation method. The results indicate that the operating modes of TABS can be determined by residential type and occupancy schedule. The load handled ratio by TABS is set up differently according to the cooling load profile obtained from residential type and occupancy schedule. By using TABS, energy consumption could be reduced by 20% compared to PTAC.

Building of Occupancy Grid Map of an Autonomous Mobile Robot Based on Stereo Vision (스테레오 비전 방식을 이용한 자율 이동로봇의 격자지도 작성)

  • Kim, Jong-Hyup;Choi, Chang-Hyuk;Song, Jae-Bok;Park, Sung-Kee;Kim, Mun-Sang
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.330-334
    • /
    • 2001
  • This paper presents the way of building an occupancy grid map which a mobile robot needs to autonomously navigate in the unknown environment. A disparity map resulting from stereo matching can be converted into the 2D distance information. If the stereo matching has some errors, however, the subsequent map becomes unreliable. In this paper, a new morphological filter is proposed to reject 'spikes' of the disparity map due to stereo mismatch by considering the fact that these spikes occur locally. The new method has advantages that it is simpler and more easily realized than existing similar algorithms.

  • PDF

Building of Occupancy Grid Map of an Autonomous Mobile Robot Based on Stereo Vision (스테레오 비전 방식을 이용한 자율 이동로봇의 격자지도 작성)

  • Kim, Jong-Hyup;Choi, Chang-Hyuk;Song, Jae-Bok;Park, Sung-Kee;Kim, Mun-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.36-42
    • /
    • 2002
  • This paper presents the way of building an occupancy grid map which a mobile robot needs to autonomously navigate in the unknown environment. A disparity map resulting from stereo matching can be converted into the 2D distance information. If the stereo matching has some errors, however, the subsequent map becomes unreliable. In this paper, a new morphological filter is proposed to reject 'spikes' of the disparity map due to stereo mismatch by considering the fact that these spikes occur locally. The new method has advantages that it is simpler and more easily realized than existing similar algorithms. Several occupancy grid maps based on stereo vision using the proposed algorithm have been built and compared with the actual distance information to verify the validity of the proposed method.

Feasibility Research of the Active RFIDs for the Smart Occupancy Detection (지능형 재실 감지 서비스를 위한 능동형 RFID의 적용 타당성 연구)

  • Choi, Yeon-Suk;Park, Byoung-Tae
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.147-155
    • /
    • 2011
  • For an effective energy management in intelligent buildings it is necessary to gather information about position/absence of people and the level of population. In this paper the smart occupancy detection system based on the active RFID is developed to satisfy such a demand. The performance of the developed system is tested and verified through various experiments. Furthermore the feasibility test of the active RFID tag is performed to verify whether it can be used as a location-based occupancy sensor. The developed core technology can be also applied to other fields such as security, healthcare, smart home, etc.

A Study on Occupancy Estimation Method of a Private Room Using IoT Sensor Data Based Decision Tree Algorithm (IoT 센서 데이터를 이용한 단위실의 재실추정을 위한 Decision Tree 알고리즘 성능분석)

  • Kim, Seok-Ho;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.23-33
    • /
    • 2017
  • Accurate prediction of stochastic behavior of occupants is a well known problem for improving prediction performance of building energy use. Many researchers have been tried various sensors that have information on the status of occupant such as $CO_2$ sensor, infrared motion detector, RFID etc. to predict occupants, while others have been developed some algorithm to find occupancy probability with those sensors or some indirect monitoring data such as energy consumption in spaces. In this research, various sensor data and energy consumption data are utilized for decision tree algorithms (C4.5 & CART) for estimation of sub-hourly occupancy status. Although the experiment is limited by space (private room) and period (cooling season), the prediction result shows good agreement of above 95% accuracy when energy consumption data are used instead of measured $CO_2$ value. This result indicates potential of IoT data for awareness of indoor environmental status.

Architectural Programming via Post Occupancy Evaluation: Case of Steel Framed School Building Seowha and Galma Primary School (학교시설(學校施設) 거주평가(居住評價)에 따른 건축기획(建築企劃) 개선(改善) - 철골조학교(鐵骨造學校) 프로젝트 서화.갈마초등학교(初等學校)의 경우(境遇))

  • Jang, Seong-Jun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.8 no.2
    • /
    • pp.13-26
    • /
    • 2001
  • The study is a Post-Occupancy-Evaluation on newly constructed steel framed school buildings sponsored by POSCO, and presents alternative tactics for planning and programming for the kind of project. The schools in concern are Seowha Primary School(Incheon city) and Galma Primary School(Daejeon city) which were completed in February 1999 and since occupied. The POE-2000 study results had to be compared to the POE-1999 which dealt on Jigog Primary School(Pohang city) and Iwol Primary School(Jincheon township) to develop an improved project tactics. In this reason we had to use the same questionnaire forms envisaged by the former study, ie. POE-1999. To begin with the same study format, it might be appropriate to differentiate whether a 'satisfaction' comes from the 'steel framed construction' or from the 'newly built environment'. However it was difficult with the POE-1999. As the intention to compare the 4 school building were the firstly achieved objective of this study that we had to continue to apply the same format and the analysis procedure. Except this condition, everything the POE-1999 conducted were valuable to this POE-2000. The satisfaction survey form includes 36 questions for individual items and 2 questions for general items.