• Title/Summary/Keyword: Building Exterior

Search Result 576, Processing Time 0.025 seconds

A Study on the Characteristics of the Interior Space of Philips Exeter Academy Library by Louis I. Kahn (필립스 엑시터 아카데미 도서관의 내부공간 특성에 관한 연구)

  • Chung Tae-Yong;Kim Nak-Jung
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.89-97
    • /
    • 2005
  • The purpose of this study is to analyze the interior characteristics of Philips Exeter Academy library by Louis I. Kahn. Kahn's main thoughts of 'what it wants to be ' and 'how it was done' play a important role in this research because these statements act as a clue to understand this library. 'What it wants to be' means the essence and existence of architecture and 'how it was done' shows the tectonic of architecture and construction process to enhance its presence. Most of his works inform that Kahn had consistently applied his thoughts into design process. The thoughts of the essence of library leads Kahn to configurate 3 layers of interior space. The emphasis of tectonic expression is also the characteristics of interior in that structure is the logical part of whole building system rather than concealing object for the exterior of buildings. In Exeter library, interior characteristics are summarized as 3 layers of interior configuration, the order in dynamics, the visualization of construction process, and the relationship between structure and space.

A Study on The Characteristics of Goods Planning and Architectural Planning of Urban Style Compact Apartment in Japan - Focus on Analysis of Apartments Sold in Tokyo City - (일본 도시형 컴팩트 아파트의 상품기획 및 계획상 특정에 관한 연구 - 도쿄도내 분양실례의 분석을 중심으로 -)

  • Yoon, Dong-Sik
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.130-139
    • /
    • 2010
  • The urban style compact apartment which appeared at the end of 1990's was developed by the decrement of household members and in compliance with a new life style. Now it has its own market as a new trend. The purpose of this study is to better understand the characteristics of urban style compact apartments based on an analysis of apartments actually sold on 2008, in order to reflect on the future directions and developments. To support a comprehensive analysis, this study considered three types of compact apartments developed by : a. major developers which own multiple well-recognized brand names, b. mid-size developers under general brand names, c. new or small-size developers specializing in compact apartments. The results from 21 urban style compact apartments could be summarized as follow; 1. Most buyers are Singles or DINKs. The single women occupy a large percentage. 2. Condition of good location is under 5 minutes walk to station and accessibility to 2 and more station. 3. Exterior of building should be harmonious to surrounding and simple, the atmosphere of entrance hall should be warm and relaxed. 4. The spatial character of unit plans are developed by the ways of connecting spaces; 1) Connecting spaces by mobile partition: flexible spaces with expansion 2) Connecting spaces by hall: well arranged spaces with excursion and extends 5. The equipments of kitchen and security are fully carefully planned.

Strengthening of non-seismically designed beam-column joints by ferrocement jackets with chamfers

  • Li, Bo;Lam, Eddie Siu-Shu;Cheng, Yuk-Kit;Wu, Bo;Wang, Ya-Yong
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1017-1038
    • /
    • 2015
  • This paper presents a strengthening method that involves the use of ferrocement jackets and chamfers to relocate plastic hinge for non-seismically designed reinforced concrete exterior beam-column joints. An experimental study was conducted to assess the effectiveness of the proposed strengthening method. Four half-scale beam-column joints, including one control specimen and three strengthened specimens, were prepared and tested under quasi-static cyclic loading. Strengthening schemes include ferrocement jackets with or without skeleton reinforcements and one or two chamfers. Experimental results have indicated that the proposed strengthening method is effective to move plastic hinge from the joint to the beam and enhance seismic performance of beam-column joints. Shear stress and distortion within the joint region are also reduced significantly in strengthened specimens. Skeleton reinforcements in ferrocement provide limited improvement, except on crack control. Specimen strengthened by ferrocement jackets with one chamfer exhibits slight decrease in peak strength and energy dissipation but with increase in ductility as compared with that of two chamfers. Finally, a method for estimating moment capacity at beam-column interface for strengthened specimen is developed. The proposed method gives reasonable prediction and can ensure formation of plastic hinge at predetermined location in the beam.

An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province (전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구)

  • Lee, Tai-Kang;Choi, Eun-Seok;Kim, Hang;Kim, Hyung-Ryul;Gi, No-Gab;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.

A Study on the Revision of Regulation to Develop for Supply of SI Separation in Long-Life Housing (장수명 공동주택의 SI분리공급 활성화를 위한 제도개선 방향설정 연구)

  • Chung, Joon-Soo;Kim, Soo-Am
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.475-478
    • /
    • 2008
  • In Korea, there has been a tendency that multi-family housings are constructed by providers such as constructors or real estate agents for the economical benefits and selling efficiency, using standardized plans, load-bearing wall system, water-based construction method, and uniformized formworks. Especially, the traditional installation works which service equipments are buried into structures cause serious problems such as shortening building life span, increasing times of remodeling during specific period (100 years) and wasting resources. Also the unilateral way of massive distribution by providers for multi-family housings is not appropriate to meet the various social needs of residents. To solve these problems, it is necessary to build long-life housing which can be easily separated installations, interior and exterior finishings from structural parts. Therefore, this paper will examine the present administrative law and the civil law in order to find negative factors that can be obstructions for providing long-life housings and set the direction to revise the regulations.

  • PDF

Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.

A Case Study on Using Interactive Media of Large Space Structure (대공간구조물의 Interactive Media 적용 사례 분석)

  • Kim, Sic;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.4
    • /
    • pp.71-78
    • /
    • 2011
  • Interactive media are applied to inner and outer space of small public space to enhance for the interaction between the spectator and works, also widely used in the exterior wall by LED and projector for advertisement. In the other hand, case studies of interactive media for large space have not less accomplished than those of buildings and public spaces. Thus, these studies analyzed 11 large structure examples by display, content, interface, and technology device by comparison of those cases of ordinary building public space. First interactive media for large space are found to be contents(39%), and next one is play(27%), advertisement(17%) and message(17%).

A Study on the Adaptable Long Life Multi-dwelling Housing Design in Korea (융통성을 고려한 장수명 공동주택 디자인에 관한 연구)

  • Kim, Jin-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.6 s.59
    • /
    • pp.172-177
    • /
    • 2006
  • Most of the Korean multi-dwelling houses have less than 20 years of lifespan. Because the environmental issues such as energy consumption, limited resources, and demolition waste problems became been more and more critical, we now need to focus on long lasting and adaptable buildings. Korean wall bearing apartment buildings are constructed with site cast concrete for core, exterior, and interior together with pipes varied, so when the buildings are old and life style of the users changes, it is difficult to maintain and renovate these buildings. In this study, to resolve the problems described above, two types of Korean long life multi-dwelling housing models which represent improved durability and adaptability responding user's needs and life style changes were proposed with various methods as follows: Either column and beam structure or flat slab structure was used to utilize space better. To make maintenance easier and renovation economical for both public space and each unit, plumbing pipes, ducts, and conduits were clustered at the cores and public corridors with access doors and light weight partitions with steel studs and raised floors or above-ceiling spaces were used in lieu of site cast concrete walls and floor slabs with varied pipes.

The sound insulation performance of eco-friendly loess brick wall (친환경 황토벽체의 차음성능 평가에 관한 연구)

  • Lee, Tai-Gang;Kim, Yul;Song, Kook-Gon;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

On the effect of steel columns cross sectional properties on the behaviours when subjected to blast loading

  • Hadianfard, Mohammad Ali;Farahani, Ahmad;B-Jahromi, Ali
    • Structural Engineering and Mechanics
    • /
    • v.44 no.4
    • /
    • pp.449-463
    • /
    • 2012
  • For buildings subjected to blast loading, structural failure can be categorized into local failure (direct blast effects) and progressive collapse (consequential effects). In direct blast effects, the intensive blast pressures create localized failure of structural elements such as exterior columns and walls. Columns, and their behaviour, play a key role in these situations. Therefore investigating the behaviour of columns under blast loading is very important to estimate the strength, safety and reliability of the whole structure. When a building is subjected to blast loading, it experiences huge loading pressures and undergoes great displacement and plastic behaviour. In order to study the behaviour of an element under blast loading, in addition to elastic properties of materials, plastic and elastic-plastic properties of materials and sections are needed. In this paper, using analytical studies and nonlinear time-history analysis by Ansys software, the effects of shape of column sections and boundary conditions, on behaviour and local failure of steel columns under blast load are studied. This study identifies the importance of elastic-plastic properties of sections and proposes criteria for choosing the best section and boundary conditions for columns to resist blast loading.