• Title/Summary/Keyword: Building Energy Management

Search Result 541, Processing Time 0.032 seconds

Research on Changes and Characteristics of GHG Emissions by Major Energy-consuming Universities in Korea - Focused on the variation since the implementation of GHG emission regulation by Government - (에너지 다소비 대학의 온실가스 배출 변화와 특성 - 온실가스 배출 규제 시행 이후의 변화를 중심으로 -)

  • Jung, Hyejin;Kim, In Chol
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.1
    • /
    • pp.74-82
    • /
    • 2017
  • It is known that energy usage from Korean Universities was growing rapidly in the early 2000s. But since 2011, the change was caused by GHG emissions regulation enforced by the government. The purpose of this research was to find the characteristics and trends of greenhouse gas emissions from major universities in Korea according to the each university's data and information. The result shows that GHG emissions from University have increased steadily prior to enforcement by 4-5% annually, but the rate of increase marked 0.5~1% in 2011~2013 is the season of emission regulation and the total amount of emissions decreased 3%~5% in 2014~2015 while preparing an emissions trading scheme. Therefore we can say that the enforcement of GHG reduction such as energy target management system makes a visible effect at least in the University sector that level of GHG emissions is from $75kg/m^2$ to $58Kg/m^2$ for seven years. Another result says that the size of research fund is the main factor that affects the amount of GHG emissions before 2011, but the size of building area has been a new factor influencing the GHG emission since 2013. Thus we suggest that the criteria for evaluating the level of GHG emission from University is suitable if it is based on the building area intensity.

Design of IoT-based Energy Monitoring System for Residential Building (IoT 기반 주택형 건물 에너지 모니터링 시스템 설계)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1223-1230
    • /
    • 2021
  • Recently, energy resource management is a major concern around the world. Energy management activities minimize environmental impacts of the energy production. This paper presents design and prototyping of a home electric energy monitoring system that provides residential consumers with real time information about their electricity use. The developed system is composed of an in-house sensing system and a server system. The in-home sensing system is a set of wireless smart plug which have an AC power socket, a relay to switch the socket ON/OFF, a CT sensor to sense current of load appliance and a Kmote. The Kmote is a wireless communication interface based on TinyOS. Each sensing node sends its detection signal to a home gateway via wireless link. The home gateway stores the received signals into a remote database. The server system is composed of a database server and a web server, which provides web-based monitoring system to residential consumers. We analyzed and presented energy consumption data from electrical appliances for 3 months in home. The experimental results show the promising possibilities to estimate the energy consumption patterns and the current status.

The Substantiation of the Building Energy Management System with Renewable Energy Resources and its Effect Analysis on the Energy Saving (신재생 분산자원을 도입한 건물 에너지관리시스템 실증 및 에너지 절감효과 분석)

  • Jeong, Su-Mi;Park, Jong-Tae;Park, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.535-536
    • /
    • 2015
  • 장기적인 에너지 수급 불안정과 기후변화에 대응하여 지속 가능한 에너지 공급체계인 신재생 에너지의 이용은 1차 에너지 소비 절감을 위한 중요한 요소로 인식되어가고 있다. 이에 국내 총 에너지 소비량의 약 25%를 차지하는 건물 분야에서도 신재생 에너지원의 적용을 확대함에 따라 생산과 소비 최적화를 통한 효율적인 통합 운용 및 제어가 가능한 건물에너지관리시스템의 필요성이 부각되고 있다. 본 논문에서는 신재생 분산자원을 도입하여 건물에너지관리시스템을 구축 및 실증하고 그에 따른 에너지 절감효과를 분석하였다.

  • PDF

A Study on Green Remodeling Methods of Apartment Houses (공동주택의 환경친화적 리모델링 계획 방법에 관한 연구)

  • Na, Su-Yeun
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.9-19
    • /
    • 2003
  • This study aims to propose Green Remodelling methods of apartment houses in Korea. Through the literature review and case studies various 'Green' Remodelling elements including environmental friendly technologies were identified and classified. Design strategies and remodeling techniques which could increase energy efficiency, reduce water and resource use, improve air qualify, improve landscape management, and improve maintenance were also investigated. Then, 'Green remodelling' methods of apartment houses are proposed as the des19n methodology of remodeling for sustainable development. The green Remodeling design methods and elements proposed by this study are proved to be simple, easy and flexible ways to enhance the environmental sustainability of the existing building.

Building Control Box Attached Monitor based Color Grid Recognition Methods for User Access Authentication

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Khudaybergenov, Timur;Kim, Min Soo;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • The secure access the lighting, Heating, ventilation, and air conditioning (HVAC), fire safety, and security control boxes of building facilities is the primary objective of future smart buildings. This paper proposes an authorized user access to the electrical, lighting, fire safety, and security control boxes in the smart building, by using color grid coded optical camera communication (OCC) with face recognition Technologies. The existing CCTV subsystem can be used as the face recognition security subsystem for the proposed approach. At the same time a smart device attached camera can used as an OCC receiver of color grid code for user access authentication data sent by the control boxes to proceed authorization. This proposed approach allows increasing an authorization control reliability and highly secured authentication on accessing building facility infrastructure. The result of color grid code sequence received by the unauthorized person and his face identification allows getting good results in security and gaining effectiveness of accessing building facility infrastructure. The proposed concept uses the encoded user access authentication information through control box monitor and the smart device application which detect and decode the color grid coded informations combinations and then send user through the smart building network to building management system for authentication verification in combination with the facial features that gives a high protection level. The proposed concept is implemented on testbed model and experiment results verified for the secured user authentication in real-time.

Development of the Passive Outside Insulation Composite Panel for Energy Self-Sufficiency of Building in the Region (지역 건축물의 에너지 자립을 위한 패시브 외단열 복합패널 개발 연구)

  • Moon, Sun-Wook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • The study aims to address the energy crisis and realize self-sufficiency of building as part of local energy independence, breaking away from a single concentrated energy supply system. It is intended to develop modules of the outside insulation composite panels that conform to passive certification criteria and for site-assembly systematization. The method of study first identifies trends and passive house in literature and advanced research. Second, the target performance for development is set, and the structural material is selected and designed to simulate performance. Third, a test specimen of the passive outside insulation curtain wall module designed is manufactured and constructed to test its heat transmission coefficient, condensation performance and airtightness. Finally, analyze performance test results, and explore and propose ways to improve the estimation and improvement of incomplete causes to achieve the goal. The final test results achieved the target performance of condensation and airtightness, and the heat transmission coefficient was $0.16W/(m^2{\cdot}K)$, which is $0.01W/(m^2{\cdot})K$ below the performance target. As for the lack of performance, we saw a need for a complementary design to account for simulation errors. It also provided an opportunity to recognize that insulated walls with performance can impact performance at small break. Thus, to be commercialized into a product with the need for improvement in the design of the joint parts, a management system is needed to increase the precision in the fabrication process.

Study on Improvement Measures of Green Standard for Energy and Environmental Design for Expansion of Applying Green Roof - Focused on LEED in the USA and BREEAM in the UK - (옥상녹화 적용확대를 위한 녹색건축인증제도 개선방안 연구 - 미국 LEED 및 영국 BREEAM의 비교·분석을 중심으로 -)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Lee, Bum-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.75-82
    • /
    • 2018
  • Green roof in Korea has been recognized as part of landscape area and local governments enacted municipal ordinance for supporting green roof thereby assisting part of expenses spent for green roof within a range of budget for buildings which are eligible for the green roof support of existing buildings. However, it is necessary to enforce a regulation of mandatory green roof for new buildings in order to expand green roof application and provide a variety of assistances such as subsidy payment, tax relief, and mitigation of floor area ratio-related regulation as done in other advanced nations. In particular, LEED(Leadership in Environmental and Energy Design) in the USA applies additional point directly for green roof in terms of the reduction in heat island effects. For example, the following items are beneficial to have additional points: habitat preservation or restoration, external space, rainwater management, reduction in outdoor water usage, minimum energy performance, and optimum energy performance. In addition, the BREEAM(Building Research Establishment Environmental Assessment Method) in the UK specifies green roof as one of assessment items to be complied in terms of diversity of species. As such, LEED and BREEAM reflect direct and indirect effects of green roof on assessment criteria, which suggest a direction to green building certification criteria in Korea where only additional points are given for green roof according to soil depth.

The Economic Value of Residential Electricity Consumption in Seoul

  • Yoo, Seung-Hoon;Lee, Seung-Ryul
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.81-85
    • /
    • 2012
  • Electricity is the basic building block of economic development, and constitutes one of the vital infra-structural inputs in socio-economic development. The demand for electricity has been increasing due to extensive urbanization, industrialization, and a rise in the standard of living, as is the case with residential electricity consumption. This paper attempts to estimate the consumer surplus and the economic value of the residential consumption of electricity in Seoul to assist in decision-making in electricity management. The estimated consumer surplus represents the value of the area under the demand curve, above the actual price that is paid for residential electricity consumption. The estimated annual consumer surplus and economic value for the year 2005 amount to 2,144.7 and 3,727.4 billion won, respectively. The estimates per kWh were 184.9 and 316.0 won, respectively, which imply that the consumer surplus and the economic value of residential electricity consumption significantly outweigh the average price of electricity in 2005 of 91.1 won per kWh.

Determining Appropriate Capacity on Installing Photovoltaic System at Deteriorated Educational Facilities

  • Lhee, Sang Choon;Choi, Young Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.23-29
    • /
    • 2014
  • With high acknowledgements of environmental conservation and energy saving, many architectural technologies using renewable energy have been recently applied at buildings which take about 20% of total energy consumption. Among renewable energy sources, the photovoltaic is considered as the most highly potential one due to advantages of infiniteness and cleanliness. Also, projects to install renewable energy systems have been continuously performed at deteriorated educational facilities as energy efficient remodeling projects or green school projects by the Korean government. This paper proposes appropriate capacities by school level on installing photovoltaic systems at deteriorated school buildings, based on the balance of annual electricity power demand and supply between buildings and systems. Using the Visual DOE program and Merit program, the appropriate installment capacity of photovoltaic system turned out be 40kWp at elementary school building and 60kWp at middle and high ones. In addition, annual energy use proved to be reduced by 20.2% at elementary school, 26.9% at middle school, and 21.0% at high school by installing photovoltaic systems with the appropriate capacities.

Study on Performance Testing of Concentric Evacuated Tube Solar Energy Collector System (이중진공관형 태양열 집열기의 성능시험에 관한 연구)

  • Yoon, Young-Hwan;Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.19-26
    • /
    • 2005
  • Concentric evacuated tube solar energy collector has been interested recently since government has driven to install alternative energy systems in new large building. In this paper, testing of the evacuated tube collector is conducted in outdoor during daytime by transient method. The collector thermal efficiencies are plotted in term of $(T_{in}-T_a)/Ic$, where $T_{in}$ is inlet working fluid temperature, $T_a$ is atmospheric temperature and $I_c$ is solar irradiation on the collector surface. The evacuated tube collector efficiency is ranged from 50% to 63% in real outdoor condition. In addition, the total overall heat loss coefficient is found to have an inverse variation to $(T_{in}-T_a)/I_c$ so that the coefficient becomes very high when $(T_{in}-T_a)/I_c$ is small.