• 제목/요약/키워드: Building Energy Management

검색결과 542건 처리시간 0.028초

Case Study On The Seismic Design Strategy For Post-Quake Functional Buildings In China

  • Peng Liu;Xue Li;Yu Cheng;Xiaoyu Gao;Jinai Zhang;Yongbin Liu
    • 국제초고층학회논문집
    • /
    • 제12권3호
    • /
    • pp.251-262
    • /
    • 2023
  • In response to China's "Regulations on the Management of Earthquake Resistance of Building Constructions" on the provision of eight types of important buildings to maintain functional after fortified earthquakes occur, "Guidelines for Seismic Design of post-quake functional buildings (Draft for Review)" distinguishes Class I and Class II buildings, and gives the performance objectives and seismic verification requirements for design earthquakes and severe earthquakes respectively. In this paper, a hospital and a school building are selected as examples to design according to the requirements of fortification of Intensity 8 and 7 respectively. Two design strategies, the seismic isolation scheme and energy dissipation scheme, are considered which are evaluated through elastic-plastic dynamic time-history analysis to meet the requirement of post-quake functional buildings. The results show that the seismic isolation design can meet the requirements in the above cases, and the energy dissipation scheme is difficult to meet the requirements of the "Guidelines" on floor acceleration in some cases, for which the scheme shall be made valid through the seismic resilience assessment. The research in this paper can provide a reference for designers to choose schemes for post-quake functional buildings.

AN EVALUATION OF ENERGY PERFORMANCE IN SUPER HIGH-RISE APARTMENT HOUSING WITH EXTERIOR WINDOW TYPES

  • Sang-Ho Lee;Yong-Ho Park;Jong-Chan Lee
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1637-1642
    • /
    • 2009
  • This study evaluates the energy performance of super high-rise residential buildings with e-QUEST simulation and calculates the annual cooling and heating load. The result of this study have concluded that the most influential factor is the characteristics of the window and also suggest the most efficient window system from the result of calculation of different glasses' cooling and heating load. The result of this study shows that The most efficient method to enhance the energy performance is to use low reflective 3 pairs Low-E glass and Low-E coating(inside of outer glass) pair glass.

  • PDF

공공건축물의 신재생에너지 적용과 에너지 사용량 분석 (Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings)

  • 이용호;서상현;김형진;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과 (Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof)

  • 송봉근;김경아;박경훈
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

국내 친환경건축물 인증제도의 예비인증과 본인증의 변화 연구-학교시설 중심으로 (A Study on Score Comparison between Preliminary and Main Certification of Green Building Certification Criteria for Educational Facilities)

  • 이현우;최창호
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.68-77
    • /
    • 2011
  • The concern of green building has been increased with an environmental problem or a rising oil price by industrialization. Therefore offices, schools and some buildings are expected to acquire the green building certification increasingly, but the information such as a process of green building certification, the state of certificated buildings, a score as specific clauses on green building certification is to seek. For not only school facilities make an effect to an student's learning achievement, but is the place where adolescents in a period of growth almost spend their life, eco-friendly school facilities is absolutely required. For this reason, systematizing the information related with the green building certification is to be needed in school field as well Therefore the effort to systematize certification management of eco-friendly school and provide information of certificated building, certification application procedure and sources related with certification for convenience is needed. Also reference material to decrease an inefficient time and expenses and to systematize certification evaluation is be able to beneficial. On the study, for such as the purpose above-mentioned, as the appraisal standard with 12 selected schools randomly is arranged. Based on the assessed scores table, features or something in common as a cause of the score change between preliminary and main certification is to be classified and anaylized.

초등학교 건축물의 생애주기 에너지사용량 및 이산화탄소 배출량 평가 (Evaluation of Life Cycle Energy Consumption and CO2 Emission of Elementary School of Buildings)

  • 지창윤;홍태훈;정재욱
    • 한국건설관리학회논문집
    • /
    • 제17권3호
    • /
    • pp.52-60
    • /
    • 2016
  • 본 연구에서는 LCA 모델을 이용하여 8개 초등학교 건축물의 생애주기 에너지사용량 및 이산화탄소 배출량을 평가 분석하였다. 이를 위하여, 자재생산, 자재운송, 시공, 운영, 해체 폐기단계를 포함하는 건축물 생애주기에서의 에너지사용량 및 이산화탄소 배출량을 평가할 수 있는 LCA 기반의 평가모델을 정의하고, 모델을 이용하여 사례 건축물을 평가하였다. 40년의 운영기간을 가정하여 평가한 결과, 내재에너지(즉, 자재생산, 자재운송, 시공단계 에너지사용량의 합), 운영에너지, 해체 폐기에너지는 평균적으로 2,279, 11,182, 228 Mcal/m2로 산출되었다. 각 단계별 평균 이산화탄소 배출량은 604, 2,708, 60 kg-CO2/m2로 산출되었다. 평가결과는 생애주기 에너지사용량 및 이산화탄소 배출량의 약 17%가 자재생산, 자재운송, 시공단계에서 발생한다는 사실을 보여준다. 따라서 건축물의 에너지사용량 및 이산화탄소 배출량 감축 목표를 달성하기 위해서는 내재에너지 및 이산화탄소 배출량이 반드시 고려되어야 할 것이다. 게다가, 운영에너지는 지역에 따라 확연하게 구분되는 반면, 내재에너지는 지역에 따른 차이가 없는 것으로 나타났다. 따라서 운영단계의 에너지 사용량 편차를 줄이기 위해서는 지역에 따라 보다 상세하게 구분된 단열 기준이 제시되어야 할 것이다.

BIM을 이용한 정보 시각화에 관한 연구 (A Study on Information Visualization using Building Information Modeling)

  • 차기춘;박승희
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4170-4175
    • /
    • 2015
  • 지구 온난화로 인한 국제적 위기가 초래됨에 따라 전 세계는 지구온난화의 주범인 온실가스를 줄이기 위해 에너지 소비를 절감하기 위한 여러 기술들을 도입하고 시행 중이다. 우리나라는 총에너지의 30%를 건물에서 소비하고 있으며, 건물 에너지를 관리하기 위해 BAS 및 BEMS을 운영하고 있지만, 현재 BEMS는 효율적인 에너지 관리를 위한 정보표현기술이 미흡한 실정이다. 따라서 본 연구에서는 BEMS의 운영효율향상을 위해 세종시 첫마을에 위치한 참샘초등학교 BEMS를 대상 으로 연구를 진행하였다. BIM을 이용하여 건물 공간정보 Web 모델을 생성하고 에너지 시각화를 위해 로컬데이터베이스를 구축하였다. 그리고 건물 공간정보 Web모델과 로컬데이터베이스를 Web Browser로 연동하여 에너지정보를 시각화 하였다. ISO/IEC 9126 국제표준을 근거하여 정량적 평가를 수행하였으며, 2달간 본 시스템을 운영하여 약 16%의 에너지 절감을 확인 할 수 있었다. 우리는 3D Web Browser를 통해 BEMS의 운영효율향상을 가져올 것이라 기대한다.

국내 학교시설의 친환경건축물 인증 평가항목 및 사례 분석 (The Analysis on the Assessment Categories of Korea Green Building Certification Criteria by the Case Studies of Educational Facilities)

  • 김창성
    • 교육시설 논문지
    • /
    • 제20권2호
    • /
    • pp.15-24
    • /
    • 2013
  • Concerns about green building construction were quite increasing around the world. Therefore, Korea Government has executed the Green Building Certification Criteria(GBCC) in 2002. The GBCC of educational facilities was executed in 2005 and was revised in 2010. The aim of this paper is to check the reliability of weighting factors in all assessment categories of GBCC and to suggest the future revision direction of GBCC. For the study, the old and current version of GBCC were examined and the 5 cases certificated by the old version were analyzed and reassessed by current version to compare with the differences of the two in obtaining the green building certification. According to the results of the study, the GBCC requires additional amendments about the assessment categories of the energy consumption monitoring and building commissioning as required subjects in order to secure the stable performances of building. In addition, the categories of building management need to be assessed more intensively and the certification criteria for existing building should be enacted as soon as possible.

우정건축물(郵政建築物)의 효율적(效率的)인 에너지 및 인력(人力) 관리(管理) 방안(方案) - 통합 자원 군(群) 관리시스템의 도입을 중심으로 - (A Study on the Efficient Energy & Manpower Management in Post Office Building : Focused on Introduction of Total Resource Group Management System)

  • 강오식;이상중
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.25-30
    • /
    • 2007
  • 정보통신부에서 소비되는 에너지는 우체국 건물의 운영에 주고 사용되고 있어, 에너지절약은 건물의 실비를 효율적으로 관리하는 것이 매 중요하다. 이에 우체국 건물의 에너지 소비현황과 운용실태를 조사 분석하였으며, 그 결과 비효율적인 운영체계가 문제점으로 도출되었다. 이 문제점을 개선하기 위하여 시스템, 조직, 인력, 운영 등을 유기적으로 통합 관리 할 수 있는 방안이 필요하다. 본 논문은 도출된 문제점에 근거하여, 인터넷을 이용한 군 관리시스템 도입으로 전국에 우체국 건물의 자원을 통한, Group 관리하는 방안을 제시하였으며, 군(群) 관리시스템 적용 시 얻어지는 예산질감 및 기대효과에 대하여 도시하였다.

  • PDF