• 제목/요약/키워드: Building Energy Load

검색결과 657건 처리시간 0.032초

환경부하 저감을 위한 기후순응주거 사례연구 (A Case Study on the Acclimatization's Housing for Environmental Load Reduction)

  • 조성우;오세규
    • 한국주거학회논문집
    • /
    • 제24권6호
    • /
    • pp.69-79
    • /
    • 2013
  • The concept of sustainable development to preserve natural environment through economy in resources and energy is gradually distinguished since environmental problems as a series of air pollution and global warming take place now. Building occupies more than 1/3 of energy consumption in the whole world. Energy consumption of buildings caused a quick increase in the amount of energy use by air conditioning, which has a lot of effects on exhaustion of fossil energy as well as an increase in environmental load. Therefore, this research intends to suggest characteristics and direction for the designing of acclimatization's housing through the case study on acclimatization's housing. Acclimatization's housing is designed to reduce building load from the designing stage unlike green home or low-energy apartment. Also, factors which are commonly applied to acclimatization's housing are applied complexly by design strategic factors of Heating, Cooling and Lighting. The applied design factors make effects mutually and complexly. In addition, design strategy showed different priority by designing direction.

피크부하용 혼소엔진발전의 경제성 분석 (An Economic Analysis on Dual-fuel Engine Generation for Peak Load)

  • 이옥배;안재경
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1260-1268
    • /
    • 2012
  • Recently, lack of power reserve margin was observed quite often. In this paper, we studied the method to secure power source for a short time, to cut the utility power peak load, and to reduce the users electricity bills. Emergency diesel generator of an office building is to be converted into a dual-fuel engine generator which is responsible for a portion of the peak load. Compared to the conventional diesel fuel generator, the proposed dual-fuel engine is able to reduce the generation power cost by dual-fuel combustion, and it also mitigates the building's utility power peak load by charging the building's peak load. If the dead resources (a group of emergency dual-fuel engine generators), as a Virtual Power Plant, are operating in peak time, we can significantly reduce future large power development costs. We investigated the current general purpose electricity bills as well as the records of the building electric power usage, and calculated diesel engine generator renovation costs, generation fuel costs, driving conditions, and savings in electricity bills. The proposed dual-fuel engine generation method reduces 18.1% of utility power peak load, and turned out to be highly attractive investment alternative which shows more than 27% of IRR, 76 million won of NPV, and 20~53 months of payback periods. The results of this study are expected to be useful to developing the policy & strategy of the energy department.

창의 기울기에 따른 건축물 에너지 소비량 예측 (The Prediction of Energy Consumption by Window Inclination)

  • 조성우
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.27-32
    • /
    • 2011
  • Most of domestic building generally don't have fixed shading devices considering of appearance and aesthetic issues. In this study is suggested that tilt window simultaneously has a role of shading and blocking solar radiation. The tilt window thermal performance is investigated by relation ship between inclination and heating cooling road. As comparing vertical window with $5^{\circ}$ and $7^{\circ}$ of tilt window respectively, the heating load is increased by 3.6% and cooling load is reduced by 8.1% on $5^{\circ}$ tilt window and the heating load is increased by 5.3% and cooling load is reduced by 11.5% on $5^{\circ}$ tilt window. Especially, the total load of alternative tilt window is showed the reduction rate 2.6% and3.6% compared of vertical window. Therefore, the tilt window is possible to role of shading of solar radiation and reduction of heating and cooling load.

셋백기간 중 건물 냉방시스템 부하 예측을 위한 인공신경망모델 성능 평가 (Performance tests on the ANN model prediction accuracy for cooling load of buildings during the setback period)

  • 박보랑;최은지;문진우
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.83-88
    • /
    • 2017
  • Purpose: The objective of this study is to develop a predictive model for calculating the amount of cooling load for the different setback temperatures during the setback period. An artificial neural network (ANN) is applied as a predictive model. The predictive model is designed to be employed in the control algorithm, in which the amount of cooling load for the different setback temperature is compared and works as a determinant for finding the most energy-efficient optimal setback temperature. Method: Three major steps were conducted for proposing the ANN-based predictive model - i) initial model development, ii) model optimization, and iii) performance evaluation. Result:The proposed model proved its prediction accuracy with the lower coefficient of variation of the root mean square errors (CVRMSEs) of the simulated results (Mi) and the predicted results (Si) under generally accepted levels. In conclusion, the ANN model presented its applicability to the thermal control algorithm for setting up the most energy-efficient setback temperature.

공동주택의 주동 유형별 냉난방부하 분석 (Cooling and Heating Load Analysis According to Building Type of Apartment House)

  • 윤성민;이경희;안영철;김용태
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.45-50
    • /
    • 2014
  • This study focuses on the analysis of the cooling and heating load in accordance with apartment houses arrangement type using Ecotect Analysis. Korea have to reduce energy consumption part of building except in industry and transport because the rate of dependence on imports amounts to 94%, Apartment houses built in various forms in order to reduce energy are modelled in each window area ratio, shape, orientation, and climate through simulation. Through this study, we can analyze the cooling and heating load by form, window area ratio, orientation, and climate change and know the optimal elements by the form. In particular, although there have been done research on the window area ratio and the arrangement form, the research of the regional climate characteristics and the direction are hardly carried out. To supplement those problem, adding to seven direction and climatic element of southern region is characteristic(L Type, Y Type, - Type) of this study. The form of apartment houses built 10 years ago is modelled for simulation.

건물에너지효율등급향상을 위한 고효율 건물외피 성능 연구 (Study on High Performance Building Envelope for raising Building Energy Rating)

  • 현종훈;홍성희;박효순;최무혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.801-806
    • /
    • 2008
  • The best plan is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, influence, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case1,2) and vacuum or triple glazing can retrieves the investment with $120 and $$140{\sim}150$ per barrel each.

  • PDF

연료전지기반 공동주택 에너지시스템 분석모델에 관한 기초연구 (A Preliminary Study on the Analysis Model of Energy System based on Fuel Cell for Apartment Houses)

  • 이홍철;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.396-401
    • /
    • 2003
  • In the present study, preliminary investigation were carried out by analysis of energy system(heat and electricity) based on phosphoric acid fuel-cell of 50 kW for eco-apartment houses. Analysis model were consisted of fuel cell energy system, secondary energy unit and residential building of 5 stories with 20 and 40 households. And the investigation results reviewed under load pattern of heat and electric power of the apartment houses. The results showed mismatch between the needed heat load pattern and output of fuel cell energy system. The mismatch rate were assessed about 10-180% of heat load for apartment houses with season. We found that secondary energy unit are needed in order to supply insufficient heat.

  • PDF

공동주택의 에너지 자립을 위한 핵심요소기술의 에너지 성능평가 (Energy Performance Evaluation of Zero Energy Technologies for Zero Energy Multi-House)

  • 윤종호;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.161-167
    • /
    • 2007
  • Zero Energy Multi-House(ZeMH) signifies a residential building which can be self sufficient with just new and renewable energy resources without the aid of any existing fossil fuel. For success of ZeMH, various innovative energy technologies Including passive and active systems should be well integrated with a systematic design approach. The first step for ZeMH is definitely to minimize the conventional heating and cooling loads over 50% with major energy conservation measure and passive solar features which are mainly related to building design components such as super-insulation, super window, including infiltration and ventilation issues. The purpose of this study is to analyze the thermal effect of various building design components in the early design of ZeMH. The process of the study is presented in the following. 1) selection reference model for simulation 2) verification of reference model with computer simulation program(ESP-r 9.0). 3) analysis of effect according to insulation-thickness, kinds of windows, rate of infiltration. and The simulation results indicate that almost 50% savings of conventional heating load in multi-house can be achieved with the optimum design of building components such as super insulation, super window, infiltration, ventilation.

그린리모델링 에너지저감 효과 예측 Tool 구축에 관한 기초연구 - 업무시설 대상 - (A Study on the Estimation of Green Remodeling Energy Reduction Tool in Building Construction - Office Building -)

  • 주정훈;이건호;구보경;김기태
    • 대한건축학회논문집:구조계
    • /
    • 제34권8호
    • /
    • pp.13-18
    • /
    • 2018
  • The purpose of this study was to study on the estimation of green remodeling energy reduction tool in building construction. Green Remodeling Decision System that can predict the energy reduction effect in green remodeling is developed as a tool for simple remodeling of green remodeling considering users' convenience, so that it can quickly and comprehensively determine power peak load reduction factor technology. A preliminary simulation result of a short preliminary remodeling evaluation is DB. It will be developed as a tool that can be easily accessed by users such as web and apps.

대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구 (A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories)

  • 서원덕;이강국;홍원화
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.