Strength Properties of Multi-layered Insulation according to the Type of Configuration (다층형 단열재의 구성 형식에 따른 강도 특성 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.141-142
    • /
    • 2019
  • As part of the recent low-energy policy, insulation standards for buildings are increasing every year. In addition, the conventional styrofoam heat insulation material has a problem in that the thickness of the heat insulation material to achieve the standard heat transmission rate is rapidly increased. Although the risk of spreading the structure vulnerable to fire due to insufficient spacing between buildings due to thickened insulation is increasing, the high cost of high efficiency insulation is difficult to solve. On the other hand, it is known that the method to be used as a formwork using insulation is excellent in cost reduction effect by reducing the amount of formwork used and simplifying the subsequent insulation work. The purpose of this study is to evaluate the strength characteristics of multi - layered insulation materials with appropriate strength by reducing the thickness of the insulation by appropriately combining high performance phenolic foam insulation and styrofoam insulation.

  • PDF

A Study on the Calorific Value of Insulated Gang-form in Winter (동절기 단열갱폼의 발열량 변화 측정에 관한 연구)

  • Kang, In-Seon;Won, Joon-Yuen;Kim, Tae-Hui;Kim, Seong-Deok;Choi, Seok;Nam, Kyung-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.135-136
    • /
    • 2017
  • This paper examines the efficiency of the application of conventional and insulated gang forms for curing and protection of concrete by comparing the amount of electric energy required therefor. In addition, a thermal vision camera was used to identify heat loss from surfaces of the gang forms after each placement of concrete. Experimental results, show that the heat loss at the submerged temperature was large at the submerged surface due to the large calorific value at the surface of the mold. The insulated gang form had some heat loss in the horizontal bars. In the case of adiabatic reforming, the pattern shows a constant calorific value over time. In conclusion, the insulation performance is better than that of general gang form.

  • PDF

Heating Properties of Conductive Resistor by Induction Heating (유도가열에 의한 도전성 저항체의 승온특성)

  • Han, Chang-Woo;Ahn, Jae-Cheol;Oh, Sang-Gyun;Kang, Byeung-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.39-40
    • /
    • 2011
  • The purpose of this study is to select a conductive resistor as high energy efficiency through analysis of the heating properties by induction heating. The result of this study, the heating properties is capable of weaken cementitious joint in 10~30 seconds when using the conductive resistor with wire mesh or punching metal. Although the steel is higher temperature than SUS304, SUS304's heating properties are more uniform.

  • PDF

Small Wind Turbine Installed at the University Building Rooftop for Green Energy Utillization (그린에너지 활용을 위한 대학건물 옥상설치형 소형풍력발전)

  • Lee, You Suck;Kim, Jae Yong
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.14-21
    • /
    • 2014
  • As the world supply of fossil fuel sources decreases, the need for efficient energy consevation and develping green energy technologies becomes critical. Because of the high cost of the foundation for large turbines and optional high wind speed (over 12 m/s), it is very difficult to be located at inland city. For the solution above mentioned problem, we have been experimented about that not only using the adaption of wind power system on buildings for improving turbine efficiency, but also applying a wound rotor type induction generator for a small wind turbine.In this research, we try to find out the wind direction and wind speed those were measured every 1 min., during operation period, using the anemometers which consist of horizontally spinning cups on a vertical post. Performance testing for small wind turbine generating system was carried out by using the induction motor and invertor. Finally, we measured the power of 1 kW wind turbine system with the clamp meter and a voltmeter.

EA Study on the Operation Performance of Central Plant Equipment According to Part Load Characteristics (부분부하 특성을 고려한 열원기기의 운전성능 평가)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.392-397
    • /
    • 2013
  • To fulfill the demands concerning energy efficiency for zero energy buildings, various technologies of architects and engineers are required. This study aims to estimate the thermal performance of heat source equipment in which part load characteristics are considered in an office building. Overestimation of heat source equipment was reviewed through literature survey, and heating and cooling loads depending on the capacity and division of the equipment were analyzed through a simulation program (DOE-2.1E). The conclusions gained from this study are as follows; 1) The more the division of equipment, the less the heating and cooling energy consumption. 2) When a large item of equipment is divided into two small items of equipment, the optimum application rate showed as 5:5 for chiller, and 7:3 for boiler, respectively.

Development of a simulation program for the analysis of a thermal networking operation in District Heating (집단에너지 열연계운전 분석을 위한 시뮬레이터 개발)

  • Im, Yong-Hoon;Park, Hwa-Choon;Chung, Mo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.825-832
    • /
    • 2008
  • A simulation program is developed for analysing thermal networking process between the District heating and the CES(Community Energy Supply) systems. The effects of thermal networking on the District heating facilities previously being operated are implemented using mathematical correlations in terms of the fuel consumption and energy load such as heating and electricity. The operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features of the newly developed program in simulation of thermal networking process in district heating is described in terms of the reliability and the easiness for operating it etc.

  • PDF

A Basic Study for Sustainable Analysis and Evaluation of Energy Environment in Buildings : Focusing on Energy Environment Historical Data of Residential Buildings (빌딩의 지속가능 에너지환경 분석 및 평가를 위한 기초 연구 : 주거용 건물의 에너지환경 실적정보를 중심으로)

  • Lee, Goon-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.262-268
    • /
    • 2017
  • The energy consumption of buildings is approximately 20.5% of the total energy consumption, and the interest in energy efficiency and low consumption of the building is increasing. Several studies have performed energy analysis and evaluation. Energy analysis and evaluation are effective when applied in the initial design phase. In the initial design phase, however, the energy performance is evaluated using general level information, such as glazing area and surface area. Therefore, the evaluation results of the detailed design stage, which is based on the drawings, including detailed information of the materials and facilities, will be different. Thus far, most studies have reported the analysis and evaluation at the detailed design stage, where detailed information about the materials installed in the building becomes clear. Therefore, it is possible to improve the accuracy of the energy environment analysis if the energy environment information generated during the life cycle of the building can be established and accurate information can be provided in the analysis at the initial design stage using a probability / statistical method. On the other hand, historical data on energy use has not been established in Korea. Therefore, this study performed energy environment analysis to construct the energy environment historical data. As a result of the research, information classification system, information model, and service model for acquiring and providing energy environment information that can be used for building lifecycle information of buildings are presented and used as the basic data. The results can be utilized in the historical data management system so that the reliability of analysis can be improved by supplementing the input information at the initial design stage. If the historical data is stacked, it can be used as learning data in methods, such as probability / statistics or artificial intelligence for energy environment analysis in the initial design stage.

A Case Study on Economic Analysis of a Solar Water Heating System and a Ground Source Heat Pump System Applied to a Military Building (군 복지시설의 지열시스템과 태양열시스템 경제성 평가 사례 연구)

  • Lee, Jong-Chan;Park, Young-Ho;Lee, Ghang;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • This study is to analyze the performance of SWH(Solar Water Heating) and GSHP(Ground Source Heat Pump) systems by evaluating their energy efficiency and LCC(Life Cycle Cost) as being applied to the OO hall as a selected building in the Army. The OO hall, used as bathrooms, dining rooms, accommodations and offices, has reinforced concrete structure system with three floors above the ground and one underground, and its total floor area is approximately 2,917$m^2$. Two energy simulations are conducted to predict the yearly cooling and heating energy of the selected building: One is for analysis of an air-conditioning energy consumption using the e-Quest program, and another is for two new-renewable energy facilities as a water heating source using the RETScreen. The installed capacity of two new-renewable energy facilities is determined according to the 5% level of total standard construction cost. As a briefly result, SWH system is more energy-effective than GSHP system. Considering the break-even point, it is expected that SWH can take only 3 years 11 months to pay for itself in savings while the investment of GSHP can be recovered in more than 16 years 6 months.

Case Study on 5kWp Transparent Thin-Film BIPV System (5kW급 투광형 박막 BIPV시스템의 실증연구)

  • An, Young-Sub;Kim, Sung-Tae;Lee, Sung-Jin;Song, Jong-Hwa;Hwang, Sang-Kun;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.29-35
    • /
    • 2010
  • This study has been carried out empirical research on Transparent Thin-film BIPV modules, BIPV modules installed on the exterior of the building are applied a laminated module 1kWp, double-glazing module 3kWp and triple-glazing module 1kWp. Applied to the total capacity of BIPV modules are 5kWp. In this study, design and construction process of BIPV systems is presented. In addition, through monitoring of the BIPV system, the temperature and the power characteristics of each module were analyzed. During the measurement period, the module temperature measurement results, the maximum surface temperature of $51.5^{\circ}C$ triple-glazing BIPV module showed the highest, followed by double-glazing BIPV module $49.1^{\circ}C$, $44.7^{\circ}C$ laminated modules, respectively. Power output results, the daily average double-layer modules showed 4.10kWh/day, triple-glazing module 1.57kWh, respectively 1.81kWh laminated modules. In particular, the power efficiency of triple-glazing BIPV module was lower than the power efficiency of the laminated BIPV module. This phenomenon is considered to be affected by the module temperature. In the future, BIPV modules in this study the relationship between module temperature and power characteristics plans to identify.

A Study on the Lighting Plan Characteristics of Office Buildings (오피스 건물의 실내 조명 유형 및 계획특성에 관한 연구)

  • Yi, Yon-Soo;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.47-54
    • /
    • 2013
  • For the office work environmental design, the importance of the design management is increased to improve operation efficiency as well as the aesthetic environmental implementation of the function today. Lighting is a required element ineffective operation environment. It has become more important for the aesthetic, economic, and practical reasons, to consider the luminous environment and the lighting of visual tasks separately. When the brightness is insufficient, productivity deteriorates, and the layout of the lighting located by mistake causes the fatigue of eyes. Productivity rises to office in a large number of studies so as satisfaction is low in general in the dark office, and to be bright. Therefore the purpose of this research is to suggest the right direction of lighting design of office building area. 11newly renovated office buildings are selected for this luminous environment research. We could conclusions as following through this research. First, it was planned brighter than the recommended lighting level in the most space. It shows that the accurate lighting design criteria is needed in order to achieve proper lighting environment. Second, the application of the LED lighting fixtures is continuously increased in the recent office lighting environment. It is explained that it is applied for reasons of the electrical energy reduction and the maintenance efficiency with the long life time. Third, the consideration of the lighting plan for the difference of working types is not enough. with various communication configuration through an independent plan, and the effective lighting plan that appropriateness preparation design and energy saving area vailable must be applied. Fourth, the lighting environment of the lobby needs a specialized lighting plan as are presentative space of the building.