Temperature Reduction with the Location of Window in a Turbine Building of Power Plant (발전소 터빈건물의 창문 위치에 따른 온도저감)

  • Ha, J.S.;Kim, T.K.;Jeong, K.H.
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.207-213
    • /
    • 2016
  • In this study, a thermal flow analysis was performed using the commercial code, ANSYS-FLUENT to reduce room temperature in a turbine building of power plant. The selected control volume of the operating floor and deaerator floor for the turbine building was respectively modelled. The skylight windows at the deaerator floor were employed for ventilation windows. Through the study, in the first we found that all window close of the deaerator floor is one alternative for reducing the temperature of the operating floor. The next thing we knew that for windows open at the front of the deaerator floor, the temperature of deaerator zone and crane zone can be respectively reduced to $1.5^{\circ}C$ and $1.6^{\circ}C$. In addition, for windows close at the rear of the deaerator floor, the temperature of deaerator zone and crane zone can be respectively reduced to 1.4 and $0.5^{\circ}C$. Therefore, it was concluded that a better choice is to open the front windows at deaerator floor to reduce the temperature of the entire deaerator floor having high temperature.

A Study on Application Analysis Using RETRAN Computer Code for the Environmental Qualification Flood Analysis Following the Main Feed Water Line Break (주급수관 파단에 따른 내환경검증 침수분석용 전산코드 RETRAN의 적용 해석연구)

  • Park, Young-Chan;Cho, Cheon-Hwey;Hong, Sung-In
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2007
  • Flood issue for nuclear power plants designed and built in 1970 is extremely severe for main steam header compartment and main feedwater line region of intermediate building and lower floor. A calculation for flood level at the main feedwater line isolation compartment is now performing by hand calculation. But, this methodology is quite conservative assumption. The goal of this study was to develop method to analyze flowrate using the RETRAN-3D computer code, and the developed method was applied to flood level analysis following main feedwater line break. As a result of analysis, flood level was low remarkably.

Influence of near-fault ground motions characteristics on elastic seismic response of asymmetric buildings

  • Tabatabaei, R.;Saffari, H.
    • Structural Engineering and Mechanics
    • /
    • v.40 no.4
    • /
    • pp.489-500
    • /
    • 2011
  • The elastic seismic response of plan-asymmetric multi storey steel-frame buildings is investigated under earthquake loading with particular emphasis on forward-rupture directivity and fling records. Three asymmetric building systems are generated with different torsional stiffness and varying static eccentricity. The structural characteristic of these systems are designed according to UBC 97 code and their seismic responses subjected to a set of earthquake records are obtained from the response history analysis (RHA) as well as the linear static analysis (LSA). It is shown that, the elastic torsional response is influenced by the intensity of near-fault ground motions with different energy contents. In the extreme case of very strong earthquakes, the behaviour of torsionally stiff buildings and torsionally flexible buildings may differ substantially due to the fact that the displacement envelope of the deck depends on ground motion characteristics.

Numerical Study on the 300 MW Shell-type One-stage Entrained Flow Coal Gasifier Apllied with 4-Layer Slagging Model (4-Layer Slagging Model을 적용한 300 MW급 Shell형 1단 분류층 석탄 가스화기 전산수치해석)

  • Hong, Jung-Woo;Jeong, Hyo-Jae;Song, Ji-Hoon;Hwang, Jung-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • A slag building simplified model was developed to determine wall heat flux of a Shell 300 MW coal gasifier. In the model 4 layers(particulate, sintered, molten slag, solidified slag) were considered and mass conservation and energy balance were used to obtain each slag layer's thickness and surface temperature. Thermo-chemical and fluid charateristics of the gasifier were studied with and without considering the slag model using commercial CFD code FLUENT. Consideration of the slag layer did not affect syn-gas mole fractions. However, the slag layer caused to increase the exit gas temperature by about 50 K.

Behavior, Design, and Modeling of Structural Walls and Coupling Beams - Lessons from Recent Laboratory Tests and Earthquakes

  • Wallace, John W.
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.1
    • /
    • pp.3-18
    • /
    • 2012
  • Observed wall damage in recent earthquakes in Chile and New Zealand, where modern building codes exist, exceeded expectations. In these earthquakes, structural wall damage included boundary crushing, reinforcement fracture, and global wall buckling. Recent laboratory tests also have demonstrated inadequate performance in some cases, indicating a need to review code provisions, identify shortcomings and make necessary revisions. Current modeling approaches used for slender structural walls adequately capture nonlinear flexural behavior; however, strength loss due to buckling of reinforcement and nonlinear and shear-flexure interaction are not adequately captured. Additional research is needed to address these issues. Recent tests of reinforced concrete coupling beams indicate that diagonally-reinforced beams detailed according to ACI 318-$11^1$ can sustain plastic rotations of about 6% prior to significant strength loss and that relatively simple modeling approaches in commercially available computer programs are capable of capturing the observed responses. Tests of conventionally-reinforced beams indicate less energy dissipation capacity and strength loss at approximately 4% rotation.

Evaluation of Response Modification Factore for Earthquake Resistant Design of Moment-Resisting Steel Frames (모멘트-연성 강구조물의 내진설계를 위한 반응수정계수의 평가)

  • 송종걸
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.201-208
    • /
    • 1997
  • In most seismic codes such as the Uniform Building Code(UBC), the response modification factor(or the force reduction factor)is used to reflect the capability of a structure in dissipating energy through inelastic behavior. The response modification factor is assigned according to structural system type. Ductile systems such as special moment-resisting steel frames are assigned larger values of the response modification factor, and are consequently designed for smaller seismic design forces. Therefore, structural damage may occur during a severe earthquake. To ensure safety of the structures, the suitability of the response modification factor used in aseismic design procedures shall be evaluated. The object of this study is to develop a method for the evaluating of the response modification factor. The validity of the evaluating method has been examined for several cases of different structures and different earthquake excitations.

  • PDF

S-FEAR: Secure-Fuzzy Energy Aware Routing Protocol for Wireless Sensor Networks

  • Almomani, Iman;Saadeh, Maha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.4
    • /
    • pp.1436-1457
    • /
    • 2018
  • Secure routing services in Wireless Sensor Networks (WSNs) are essential, especially in mission critical fields such as the military and in medical applications. Additionally, they play a vital role in the current and future Internet of Things (IoT) services. Lightness and efficiency of a routing protocol are not the only requirements that guarantee success; security assurance also needs to be enforced. This paper proposes a Secure-Fuzzy Energy Aware Routing Protocol (S-FEAR) for WSNs. S-FEAR applies a security model to an existing energy efficient FEAR protocol. As part of this research, the S-FEAR protocol has been analyzed in terms of the communication and processing costs associated with building and applying this model, regardless of the security techniques used. Moreover, the Qualnet network simulator was used to implement both FEAR and S-FEAR after carefully selecting the following security techniques to achieve both authentication and data integrity: the Cipher Block Chaining-Message Authentication Code (CBC-MAC) and the Elliptic Curve Digital Signature Algorithm (ECDSA). The performance of both protocols was assessed in terms of complexity and energy consumption. The results reveal that achieving authentication and data integrity successfully excluded all attackers from the network topology regardless of the percentage of attackers. Consequently, the constructed topology is secure and thus, safe data transmission over the network is ensured. Simulation results show that using CBC-MAC for example, costs 0.00064% of network energy while ECDSA costs about 0.0091%. On the other hand, attacks cost the network about 4.7 times the cost of applying these techniques.

Preliminary Evaluation of the Activity Concentration Limits for Consumer Goods Containing NORM

  • Jang, Mee;Chung, Kun Ho;Ji, Young Yong;Lim, Jong Myung;Kang, Mun Ja;Choi, Guen Sik
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.101-104
    • /
    • 2016
  • Background: To protect the public from natural radioactive materials, the 'Act on safety control of radioactive rays around living environment" was established in Korea. There is an annual effective dose limit of 1 mSv for products, but the activity concentration limit for products is not established yet. Materials and Methods: To suggest the activity concentration limits for consumer goods containing NORM, in this research, we assumed the "small room model" surrounding the ICRP reference phantom to simulate the consumer goods in contact with the human bodies. Using the Monte Carlo code MCNPX, we evaluate the effective dose rate for the ICRP reference phantom in a small room with dimension of phantom size and derived the activity concentration limit for consumer goods. Results and Discussion: The consumer goods have about 1600, 1200 and $19000Bq{\cdot}kg^{-1}$ for $^{226}Ra$, $^{232}Th$ and $^{40}K$, and the activity concentration limits are about six times comparing with the values of building materials. We applied the index to real samples, though we did not consider radioactivity of $^{40}K$, indexes of the some samples are more than 6. However, this index concept using small room model is very conservative, for the consumer goods over than index 6, it is necessary to reevaluate the absorbed dose considering real usage scenario and material characteristics. Conclusion: In this research, we derived activity concentration limits for consumer goods in contact with bodies and the results can be used as preliminary screening tool for consumer goods as index concept.

Flexural strengthening of RC Beams with low-strength concrete using GFRP and CFRP

  • Saribiyik, Ali;Caglar, Naci
    • Structural Engineering and Mechanics
    • /
    • v.58 no.5
    • /
    • pp.825-845
    • /
    • 2016
  • The Turkish Earthquake Code was revised in 1998 and 2007. Before these Codes, especially 1998, reinforced concrete (RC) beams with low flexural and shear strength were widely used in the building. In this study, the RC specimens have been produced by taking into consideration the RC beams with insufficient shear and tensile reinforcement having been manufactured with the use of concrete with low strength. The performance of the RC specimens strengthened with different wrapping methods by using of Carbon Fibre Reinforced Polymer (CFRP) and Glass Fibre Reinforced Polymer (GFRP) composites have been examined in terms of flexural strength, ductility and energy absorption capacity. In the strengthening of the RC elements, the use of GFRP composites instead of CFRP composites has also been examined. For this purpose, the experimental results of the RC specimens strengthened by wrapping with CFRP and GFRP are presented and discussed. It has been concluded that although the flexural and shear strengths of the RC beams strengthened with GFRP composites are lower than those of beams reinforced with CFRP, their ductility and energy absorption capacities are very high. Moreover, the RC beams strengthened with CFRP fracture are more brittle when compared to GFRP.

REVIEW OF SPENT FUEL INTEGRITY EVALUATION FOR DRY STORAGE

  • Kook, Donghak;Choi, Jongwon;Kim, Juseong;Kim, Yongsoo
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.115-124
    • /
    • 2013
  • Among the several options to solve PWR spent fuel accumulation problem in Korea, the dry storage method could be the most realistic and applicable solution in the near future. As the basic objectives of dry storage are to prevent a gross rupture of spent fuel during operation and to keep its retrievability until transportation, at the same time the importance of a spent fuel integrity evaluation that can estimate its condition at the final stage of dry storage is very high. According to the national need and technology progress, two representative nations of spent fuel dry storage, the USA and Japan, have established different system temperature criteria, which is the only controllable factor in a dry storage system. However, there are no technical criteria for this evaluation in Korea yet, it is necessary to review the previously well-organized methodologies of advanced countries and to set up our own domestic evaluation direction due to the nation's need for dry storage. To satisfy this necessity, building a domestic spent fuel test database should be the first step. Based on those data, it is highly recommended to compare domestic data range with foreign results, to build our own criteria, and to expand on evaluation work into recently issued integrity problems by using a comprehensive integrity evaluation code.