• 제목/요약/키워드: Building Energy Assessment

검색결과 295건 처리시간 0.025초

Performance assessment of RC frame designed using force, displacement & energy based approach

  • Kumbhara, Onkar G.;Kumar, Ratnesh
    • Structural Engineering and Mechanics
    • /
    • 제73권6호
    • /
    • pp.699-714
    • /
    • 2020
  • Force based design (FBD) approach is prevalent in most of the national seismic design codes world over. Direct displacement based design (DDBD) and energy based design (EBD) approaches are relatively new methods of seismic design which claims to be more rational and predictive than the FBD. These three design approaches are conceptually distinct and imparts different strength, stiffness and ductility property to structural members for same plan configuration. In present study behavioural assessment of frame of six storey RC building designed using FBD, DDBD and EBD approaches has been performed. Lateral storey forces distribution, reinforcement design and results of nonlinear performance using static and dynamic methods have been compared. For the three approaches, considerable difference in lateral storey forces distribution and reinforcement design has been observed. Nonlinear pushover analysis and time history analysis results show that in FBD frame plastic deformation is concentrated in the lower storey, in EBD frame large plastic deformation is concentrated in the middle storeys though the inelastic hinges are well distributed over the height and, in DDBD frame plastic deformation is approximately uniform over the height. Overall the six storey frame designed using DDBD approach seems to be more rational than the other two methods.

옥외광고용 발광조명의 야간휘도분포 분석 (Luminance Assessment of Outdoor Lighting for Advertisements at Night)

  • 신화영;이종수;김정태
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.

Sustainable energy action plans of medium-sized municipalities in north Greece

  • Lymperopoulos, Konstantinos A.;Botsaris, Pantelis N.;Angelakoglou, Komninos;Gaidajis, Georgios
    • Advances in Energy Research
    • /
    • 제3권1호
    • /
    • pp.11-30
    • /
    • 2015
  • The covenant of Mayors initiative includes the commitment of the municipalities-signatories to reduce voluntarily the greenhouse gas emissions over 20--- by 2020 within their boundaries and obligates them to develop and submit an energy consumption analysis and a sustainable energy action plan within a year from the adhesion. The present paper discusses the energy profile of three medium-sized north-eastern Greek Municipalities (Kavala-MoK, Alexandroupolis-MoA, Drama-MoD) through the analysis of their municipal energy balance. The results of the total final energy consumption per capita include 14.10MWh/capita, 14.24MWh/capita and 12.91MWh/capita for MoK, MoA and MoD respectively. The analysis highlighted the increased energy consumption of the private sectors, namely residential and tertiary building sand private transport. The assessment of the municipalities' energy profiles along with examination of national regulations and action plans and investigation of best available practices within the Covenant of Mayors shaped the development of the sustainable energy action plans of the examined municipalities that is presented in this paper. The proposed pathway towards low-carbon municipalities can be considered a representative case study and a starting point for other municipalities with similar characteristics.

겨울 유채의 환경성 평가를 위한 전과정평가(LCA) 방법론 (Methodology of Life Cycle Assessment(LCA) for Environmental Impact Assessment of Winter Rapeseed in Double-cropping System with Rice)

  • 남재작;옥용식;최봉수;임송택;정용수;장영석;양재의
    • 한국환경농학회지
    • /
    • 제27권2호
    • /
    • pp.205-210
    • /
    • 2008
  • Life cycle assessment(LCA) is acknowledged as a valuable tool to quantify the environment impact of agricultural practice as well as final product(biodiesel) considering whole life cycle of the target product. As a preliminary research of LCA study for rapeseed(Brassica napus L.) biodiesel, the methodological issues which have to be regarded with high priority were dealt with. No life cycle inventory(LCI) based on local data are currently available for LCA of rapeseed cultivation, crushing, and conversion to rapeseed methyl ester(RME) in Korea. In this paper, the life cycle of rapeseed and methodological factors which have to be measured for building LCI of each process are provided and discussed, which are including seed, fertilizer, energy use in rapeseed cultivation environment; and crushing, RME conversion, and transportation in biodiesel production.

Condition assessment of steel shear walls with tapered links under various loadings

  • He, Liusheng;Kurata, Masahiro;Nakashima, Masayoshi
    • Earthquakes and Structures
    • /
    • 제9권4호
    • /
    • pp.767-788
    • /
    • 2015
  • A steel shear wall with double-tapered links and in-plane reference was developed for assisting the assessment of the structural condition of a building after an earthquake while maintaining the original role of the wall as a passive damper device. The double-tapered link subjected to in-plane shear deformation is designed to deform torsionally after the onset of local buckling and works as an indicator of the maximum shear deformation sustained by the shear wall during an earthquake. This paper first examines the effectiveness of double-tapered links in the assessment of the structural condition under various types of loading. A design procedure using a baseline incremental two-cycle loading protocol is verified numerically and experimentally. Meanwhile, in-plane reference links are introduced to double-tapered links and greatly enhance objectivity in the inspection of notable torsional deformation with the naked eye. Finally, a double-layer system, which consists of a layer with double-tapered links and a layer with rectangular links made of low-yield-point steel, is tested to demonstrate the feasibility of realizing both structural condition assessment and enhanced energy dissipation.

Design Method of Steel Slit Shear Walls with Tapered Links for Structural Condition Assessment

  • He, Liusheng;Wu, Chen;Jiang, Huanjun
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.361-368
    • /
    • 2020
  • The authors developed a new type of steel slit shear wall (SSSW) having the function of structural condition assessment through visually inspecting the out-of-plane deformation of the designed tapered links subjected to lateral deformation. To facilitate its practical application, this paper studies how to design dimensions of the tapered links. Two parameters, the width-to-thickness ratio of the tapered links and steel yield stress, were studied. The performance of structural condition assessment was affected by both parameters with the width-to-thickness ratio being the controlling one. Through both numerical and experimental study, the designed width-to-thickness ratio of tapered links for different levels of structural condition assessment was established considering the effect of different steel grades used. In practice, the dimensions of tapered links can be determined following the design equation provided. Finally, a design procedure for the proposed SSSW system is provided.

반투과형 태양전지를 이용한 창호형 BIPV 건물의 환경성능 분석 (Comparison assessment of semi-transparent solar cell for BIPV windows)

  • 정민희
    • 토지주택연구
    • /
    • 제11권1호
    • /
    • pp.87-94
    • /
    • 2020
  • To implement the planning of zero-energy buildings, their energy performance must be improved, and renewable energy applications must also be included. To accelerate the use of renewable energies in such buildings, BIPVs should be actively used in windows and on roofs. Window-type BIPVs are being developed in various forms depending on the size, composition, area ratio of the window, specification of glass, and so on. To analyze the applicability of various solar cells as window-type BIPVs, in this study, we evaluated their applicability, at the current development level, by analyzing the indoor illuminance, heat gain and heat loss; the cooling, heating, and lighting energy levels; and the generation performance of the various solar cells. To enhance the future applicability of window type BIPV, we analyze the overall energy performance of the building, according to changes in visible light transmittance and generation efficiency. The main research results are as follows. The area ratios above the standard illuminance, based on the window type and according to the VLT, were in order of low-e glazing, a-Si window, DSSC window, and c-Si window. The heat gain of the semi-transparent solar cell winodw was remarkably low. The energy consumption of buildings was highest in the order of c-Si window, DSSC window, a-Si window, and clear low-e window. However, in the case of including the power generation performance of the solar cell, the energy consumption was found to be high in order of DSSC window, c-Si window, a-Si window, and clear low-e window. In the future, if a window-type BIPV is developed, we believe that improvement in power generation performance and improvement in visible light transmittance will be needed.

Cyber R&D Platform개발을 통한 방사성폐기물 처분종합성능평가(TSPA) 투명성 증진에 관한 연구; 시나리오 도출 과정과 TSPA 데이터 입력에서의 품질보증 적용 사례 (Building Transparency on the Total System Performance Assessment of Radioactive Repository through the Development of the Cyber R&D Platform; Application for Development of Scenario and Input of TSPA Data through QA Procedures)

  • 서은진;황용수;강철형
    • 방사성폐기물학회지
    • /
    • 제4권1호
    • /
    • pp.65-75
    • /
    • 2006
  • 방사성폐기물 처분 연구 사업이 법률적인 인허가 뿐만이 아니라 일반 국민의 동의를 얻기 위해서는 처분 사업의 안전성에 대한 신뢰성 획득이 중요하며 이를 위해 투명하게 공개될 수 있는 종합 성능 평가 (TSPA, Total System Performance Assessment)의 수행 이 필요하다. 본 연구에서는 처분 성능 평가의 투명성 증진을 위한 방안의 하나로 처분 종합 성능 평가 전 과정에 대해 품질 보증 원칙을 도입하여 평가 관련 전체 업무에 관한 신뢰성 향상을 꾀하고자 하였다. 이를 위해 처분 종합 성능 평가 수행의 다섯 단계인 (1) 기획, (2) 연구 수행 , (3) 문서화, (4) 내부 검토, (5) 독자적인 외부 검토 과정에 T2R3의 품질 보증 원칙을 적용한 인터넷 기반의 Cyber R&D Platform이 개발되었다. 인터넷을 기반으로 하는 본 시스템의 개발을 통해 안전성 평가 관련 모든 참여자들은 평가 전 과정에서 투명성이 유지된 데이터들에 쉽게 접근하여 이를 이용할 수 있다 Cyber R&D Platform은 안전성 평가를 위한 시나리오 개발 관련 데이터인 FEP 목록과 관련 시나리오 정보, 관련 시나리오 도출 과정 및 평가 체계 등을 체계적으로 구축한 FEAS (FEp to Assessment through Scenario development)프로그램과 안전성 평가에 필요한 입력 데이터들을 분류, 저장해 놓은 PAID (Performance Assessment Input Data) 프로그램, 그리고 이러한 자료들을 품질 보증 원칙과 절차에 의한 승인 과정을 통해 입력, 저장할 수 있는 품질 보증 시스템으로 구성되어 있으며 이를 통합 운영함으로써 도출된 데이터들의 신뢰성을 높이고자 하였다. 향후 연구에서는 Cyber R&D Platform과 평가 software와의 통합 운영으로 웹 기반 시스템에 대한 한 번의 접속만으로 안전성 평가 관련 모든 정보를 확인, 이용할 수 있도록 할 것이다.

  • PDF

BIM 기반 에너지성능평가를 위한 국내 표준 매개변수 설정 방안에 대한 연구 - 공공청사 업무시설의 재실자 1인당 점유면적을 중심으로 - (A Study on Domestic Standard Parameter Setting for BIM-based Energy Performance Evaluation - Focused on Possession Area per Person of Occupants in Government Offices -)

  • 이윤정;이권형;김인한;추승연
    • 한국CDE학회논문집
    • /
    • 제20권1호
    • /
    • pp.11-21
    • /
    • 2015
  • Currently, the United States, the United Kingdom, Australia etc. are actively utilizing energy simulation for efficiency evaluation of building energy. However, domestic energy efficiency assessment system doesn't use energy simulation system properly at present: parameters based architecture plans and Ashrae Standard are inputted for the evaluation, because the input parameters for the simulation haven't been established yet. This fact causes poor reliability during energy simulation, as the values of the two standards are different from each other. Therefore, the aim of the study is to set domestic standard parameter for BIM-based energy performance evaluation, focusing on possession area per person of occupants at government office in Korea. We found that the difference among the result values occurred approximately 3% in the energy simulation. As a result of the analysis, possession area per person of occupants in Government office is $31.87m^2$. Other input parameters may be set based on this. This will increase the reliability of energy simulation through a domestic standard parameter.

Exploring Capabilities of BIM Tools for Housing Refurbishment in the UK

  • Kim, Ki Pyung;Park, Kenneth S
    • 한국BIM학회 논문집
    • /
    • 제6권4호
    • /
    • pp.9-17
    • /
    • 2016
  • Currently whole-house refurbishment for substantial energy efficiency improvement of existing housing stock is needed to achieve the targeted 80% CO2 emission reduction. As whole-house refurbishment requires a larger capital investment for lower CO2 emission, the simultaneous use of Life Cycle Costing (LCC) and Life Cycle Assessment (LCA) methodologies are recommended to generate affordable refurbishment solutions. However, two methodologies are difficult to use due to a lack of proper LCC and LCA datasets. As a response to the current problems, many researchers explore potentials in Building Information Modelling (BIM) to improve current construction practice. As a result, a BIM tool - IES IMPACT (Integrated Material Profile And Costing Tool) - has been introduced to the UK construction industry for simultaneous calculation of LCC and LCA. Thus, this research aims at examining the capability and limitation of the IES VE/IMPACT as a BIM tool for whole-house refurbishment. This research reveals that the IES VE/IMPACT is feasible for whole-house refurbishment by providing LCC and LCA information simultaneously for informed decision on refurbishment solution selection. This research shed lights on the current problems lying on the data exchange between two different BIM tools. It is revealed that additional efforts from construction professionals and industry are required to make reliable BIM objects library with LCC and LCA datasets.