• 제목/요약/키워드: Building Block Analysis

검색결과 177건 처리시간 0.023초

Fusion of LIDAR Data and Aerial Images for Building Reconstruction

  • Chen, Liang-Chien;Lai, Yen-Chung;Rau, Jiann-Yeou
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.773-775
    • /
    • 2003
  • From the view point of data fusion, we integrate LIDAR data and digital aerial images to perform 3D building modeling in this study. The proposed scheme comprises two major parts: (1) building block extraction and (2) building model reconstruction. In the first step, height differences are analyzed to detect the above ground areas. Color analysis is then performed for the exclusion of tree areas. Potential building blocks are selected first followed by the refinement of building areas. In the second step, through edge detection and extracting the height information from LIDAR data, accurate 3D edges in object space is calculated. The accurate 3D edges are combined with the already developed SMS method for building modeling. LIDAR data acquired by Leica ALS 40 in Hsin-Chu Science-based Industrial Park of north Taiwan will be used in the test.

  • PDF

조경블록(그린스톤)을 이용한 방음벽 구조설계시스템 (Structure Design System of Soundproofing Wall Using Green Stone)

  • 한중근;한승호
    • 한국환경복원기술학회지
    • /
    • 제3권4호
    • /
    • pp.1-10
    • /
    • 2000
  • This study aims at the new design system development of landscape architecture structures, as soundproof wall using reinforced soil block. This structures, that is new soundproof wall system, have to be maintained stability on acting critical wind load, which is combined exist soundproof wall system and soundproof wall system using environmental green stone block. To the harmony of this system, the post block, so-called landscape block or cast block, is manufactured. It's possible to stand of the post bearing system combined with post-pile and post block. Through the comparison with a serious code for the acting wind load on the soundproof wall, the reasonable wind load could be calculated. Also, the mechanical stability on the green stone block was checked by the Lab. tests based on the UBC (Uniformed Building Code). Because the critical height of soundproof wall system using green stone generally was restricted, the new system demands to combination of the exist system and the new system. For the stability analysis of them, the utility program, SAP2000, was used. And, a semi-auto program on the design system of the new soundproof wall using green stone was developed, which can be easily use because of the simplification.

  • PDF

구조체접지극 활용을 위한 모형블록의 저항률 분석 (Resistivity Analysis of Model Block for Using of Structure Grounding Electrode)

  • 김성삼;정만길;최종규;고희석
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.40-45
    • /
    • 2007
  • 건축물의 기초를 구조체접지 및 대용접지극으로 활용하기 위한 기초실험으로 모형블록의 저항률 특성에 관해 검토하였다. 콘크리트와 몰탈의 모형블록을 제작 후 상온과 함수 상태에서 저항률을 측정하였으며, 저항률을 저감시키기 위해 접지저항 저감제를 혼합한 블록을 제작 하여 비교 하였다. 블록의 저항 값은 블록 저항률에 의해 가장 많은 영향을 받으며, 블록 저항률이 동일하거나 유사한 값일 때 대지저항률 값의 차이만큼 접지저항 값의 차이가 발생하였다.

어린이집 일과유형에 따른 보육실 흥미영역구성 특성 (The Characteristics of Spatial Configuration of Activity Areas in Classrooms According to the Types of Daily Routine in Child-Care Centers in South Korea)

  • 박정아;최목화
    • 한국주거학회논문집
    • /
    • 제25권4호
    • /
    • pp.83-91
    • /
    • 2014
  • The purpose of this study is to clarify the characteristics between the type of daily routine and spatial configuration of activity areas in classroom and provide alternatives for space planning of activity areas in classroom of child-care centers. This study used the content analysis on daily activity plan and floor plans through field survey. Analysis on floor plans was conducted for 35 classrooms in 9 child-care centers which allowed field survey. The results of this study were as follows; There was no significant difference for classroom size according to the type of daily routine in 3 to 5-year-old classrooms. The average size of classrooms was $61.6m^2$ for care oriented type, $41.4m^2$ for indoor activity oriented type and $48.8m^2$ for group activity oriented type. There was no significant difference in composition of activity areas in classrooms according to the type of daily routine. In case of 0 to 2-year-old classrooms, they were composed of 6 activity areas including gross-motor, role play, block building, language, creative expression, exploration/manipulation. Activity area of the most low frequency was gross-motor area. In case of 3 to 5-year-old classrooms, most classrooms were composed of all the 7 activity areas including art, tone and rhythmic, block building, role play, language, math and science. Most accessible and central areas in 0 to 2-year-old classrooms were gross-motor and role play. Also, most separate areas were exploration/manipulation and block building. Most accessible and central areas in 3 to 5-year-old classroom were art and math. Also, most separate areas were tone and rhythmic and science.

마운트계의 실험적 설계변경을 위한 전달함수분리법의 개발 (Development of Transfer Function Separation Method for Experimental Dynamic Modification of Mounted System)

  • 정의봉;조영희
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.847-852
    • /
    • 1997
  • Many investigations about the dynamic analysis of the structural system based on the BBA(Building Block Approach) method which predict dynamic characteristics of synthesized structures from each structure. But it is actually sometimes difficult to remove mounts from structures. In this paper, TFSM(The Transfer Function Separation Method) is developed which can predict dynamic characteristics of separated structures from the data of vibrational experiment of the synthesized structures. By combining TFSM with BBA, this paper also proposes the method which can predict dynamic characteristics of mount-modified structure without removing mounts from structures. And the proposed method is verified by the experimental data of plates.

  • PDF

빗물침투저류블록의 설치 최적지 선정을 위한 침수범람 시뮬레이션 프로그램의 개발 (Development of Inundation Flooding Simulation Program for Selecting Optimum Installation Site for Rainwater Infiltration Detention Block)

  • 김성표;이태규;류정림;박선미;최희용;최형길
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.129-130
    • /
    • 2023
  • This study proposes rainwater infiltration retention blocks as a solution to the flooding problems caused by recent climate change and developed a flood prediction simulation program to select the optimal site for installing rainwater infiltration retention blocks that can minimize damage from floods. By applying the existing 2D flood analysis model G2D and adding a reservoir function, the volume of water before and after installation can be determined through simulation results.

  • PDF

콘칼로리미터와 적외선분광계(FTIR)를 이용한 폼블럭의 연소특성에 대한 실험적 연구 (A Study on the Fire Characterization of Foam block using Cone-calorimeter and FTIR)

  • 한봉훈;서동호;권영희;민세홍
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.23-32
    • /
    • 2017
  • 폼블럭은 셀프 인테리어 용품으로 새롭게 유행하고 있는 건축마감재로 폴리에틸렌을 주성분으로 하여 제조되고 있어 화재에 취약할 것으로 판단된다. 시중에 판매되고 있는 폼블럭 2종(일반, 난연)을 KS F ISO 5660-1(연소성능시험)의 기준에 따라 화재시 발생되는 연소특성을 파악하였다. 또한 적외선분광계(FTIR)를 이용하여 시편의 연소로 발생하는 가스중 대표적 독성가스를 측정한 후 기존의 독성모델에 적용하였다. 콘칼로리미터 시험 결과 2종의 시편 모두 복사열 차단장치를 제거하자마자 인화 및 불꽃연소가 시작되어, 화재시 화염의 급속한 전파 요인이 될 수 있음을 확인하였으며, 적외선분광계를 통한 연소가스 분석 결과, 일반적인 연소가스인 이산화탄소와 일산화탄소뿐만 아니라 인체에 심각한 위해를 주는 아크롤레인, 암모니아 및 시안화수소 등이 다량 검출되었다. 본 연구를 통해 폼블럭 제품은 착화성과 발열량이 높으며 유해가스가 다량 방출될 수 있음을 실험을 통해 확인하였다. 따라서 폼불럭 사용에 따른 재료의 연소특성, 즉 착화성 저감, 최대 열방출률 제한 및 주요 유해가스의 농도를 제한하는 기준마련도 시급히 요구된다.

2학년 쌓기나무 수업에서의 수학적 의사소통 분석 (Analysis of Mathematical Communication in Building-Block Lessons for 2nd Graders)

  • 장혜원
    • 대한수학교육학회지:학교수학
    • /
    • 제17권2호
    • /
    • pp.223-239
    • /
    • 2015
  • 본 연구는 내용요소인 쌓기나무와 과정요소인 수학적 의사소통의 연계 활동을 통해 구현되는, 공간 정보를 의사소통하기 위한 교실 언어에 초점이 있다. 초등학교 2학년 수학 교과서에는 쌓기나무의 쌓인 모양을 상대방이 듣고 똑같이 쌓을 수 있도록 설명하는 활동이 있지만, 교사-학생, 학생 간에 어떠한 방식으로 의사소통 하는지, 효과적인 의사 소통 방법이 무엇인지에 대해 거의 연구된 바 없다. 이에 본 연구에서는 초등학교 2학년 쌓기나무 수업을 관찰하고, 그 때 교사의 지도 과정상 나타나는 특징, 학생의 쌓기나무 모양 설명시 드러나는 특성, 교사와 학생간 의사소통 유형 등을 분석함으로써 쌓기 나무 수업에서 수학적 의사소통의 양방향인 설명과 이해를 저해하는 요인을 추출하고, 그 결과에 기초하여 효과적인 의사소통 전략의 지도를 위한 방안을 제언하였다.

Influence of bi-directional seismic pounding on the inelastic demand distribution of three adjacent multi-storey R/C buildings

  • Skrekas, Paschalis;Sextos, Anastasios;Giaralis, Agathoklis
    • Earthquakes and Structures
    • /
    • 제6권1호
    • /
    • pp.71-87
    • /
    • 2014
  • Interaction between closely-spaced buildings subject to earthquake induced strong ground motions, termed in the literature as "seismic pounding", occurs commonly during major seismic events in contemporary congested urban environments. Seismic pounding is not taken into account by current codes of practice and is rarely considered in practice at the design stage of new buildings constructed "in contact" with existing ones. Thus far, limited research work has been devoted to quantify the influence of slab-to-slab pounding on the inelastic seismic demands at critical locations of structural members in adjacent structures that are not aligned in series. In this respect, this paper considers a typical case study of a "new" reinforced concrete (R/C) EC8-compliant, torsionally sensitive, 7-story corner building constructed within a block, in bi-lateral contact with two existing R/C 5-story structures with same height floors. A non-linear local plasticity numerical model is developed and a series of non-linear time-history analyses is undertaken considering the corner building "in isolation" from the existing ones (no-pounding case), and in combination with the existing ones (pounding case). Numerical results are reported in terms of averages of ratios of peak inelastic rotation demands at all structural elements (beams, columns, shear walls) at each storey. It is shown that seismic pounding reduces on average the inelastic demands of the structural members at the lower floors of the 7-story building. However, the discrepancy in structural response of the entire block due to torsion-induced, bi-directionally seismic pounding is substantial as a result of the complex nonlinear dynamics of the coupled building block system.

Sound transmission of lightweight block walls and panels-Theory and Experiments

  • S Kandaswamy;A Ramachandraiah
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.235-239
    • /
    • 2004
  • Sound transmission either as airborne or structure borne is a potential problem that occurs in buildings either from sources within or from outside. With the expansion of real estate activities in countries like India, the need to attend sound insulation requirements also assumes greater dimensions. The focus of this research is on studying the sound transmission characteristics of building structures made of hollow blocks, neocrete block, aerocon block and prefabricated panels such as Ferrocement panel. The tests were carried out the blocks with and without plastering and their sound reduction index was measured at one-third octave frequencies. In the case of ferrocement panels, different types of systems were tested in the TL suite. Panels with cavity, with cavity ties, with insulation, with stiffeners and with plasterboard were investigated. Sound reduction index of these panels was measured with additional quantities like longitudinal wavespeed, and loss factors (internal and total loss factor). Tests were also conducted on Cypcrete wall panel and Sandwiched wooden panel in a similar way. Theoretical investigations were carried out using Statistical Energy Analysis (SEA) for the above systems. Sound reduction index was then compared between the predicted and the measured values.

  • PDF