• Title/Summary/Keyword: Buffer Stability

Search Result 294, Processing Time 0.028 seconds

Effect of gas composition on the characteristics of a-C:F thin films for use as low dielectric constant ILD (가스 조성이 저유전상수 a-C:F 층간절연막의 특성에 미치는 영향)

  • 박정원;양성훈;이석형;손세일;오경희;박종완
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.4
    • /
    • pp.368-373
    • /
    • 1998
  • As device dimensions approach submicrometer size in ULSI, the demand for interlayer dielectric materials with very low dielectric constant is increased to solve problems of RC delay caused by increase in parasitic resistance and capacitance in multilevel interconnectins. Fluorinated amorphous carbon in one of the promising materials in ULSI for the interlayer dielectric films with low dielectric constant. However, poor thermal stability and adhesion with Si substrates have inhibited its use. Recently, amorphous hydrogenated carbon (a-C:H) film as a buffer layer between the Si substrate and a-C:F has been introduced because it improves the adhesion with Si substrate. In this study, therfore, a-C:F/a-C:H films were deposited on p-type Si(100) by ECRCVD from $C_2F_6, CH_4$and $H_2$gas source and investigated the effect of forward power and composition on the thickness, chemical bonding state, dielectric constant, surface morphology and roughness of a-C:F films as an interlayer dielectric for ULSI. SEM, FT-IR, XPS, C-V meter and AFM were used for determination of each properties. The dielectric constant in the a-C:F/a-C:H films were found to decrease with increasing fluorine content. However, the dielectric constant increased after furnace annealing in $N_2$atomosphere at $400^{\circ}C$ for 1hour due to decreasing of flurorine content. However, the dielectric constant increased after furnace annealing in $N_2$atmosphere at $400^{\circ}C$ for 1hour due to decreasing of fluorine concentration.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

A Comparative Study on the Pharmaceutical Properties of Rectal Suppository containing Omeprazole Complexes (오메프라졸복합체 함유 직장좌제의 특성비교)

  • Hwang, Sung-Joo;Park, Sung-Bae;Rhee, Gye-Ju
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.3
    • /
    • pp.227-237
    • /
    • 1995
  • Omeprazole(OMP) complexes such as inclusion complexes of OMP with $hydroxypropyl-{\beta}-cyclodextrin$(HPCD) and ${\beta}-cyclodextrin({\beta}-CD)$, OMP-cholestyramine(CHL) and OMP-ethylenediamine(OMP-ED) were prepared, respectively. The partition coefficients in Witepsol H-15 /pH 7.4 phosphate buffer solution of OMP complexes$(OMP-HPCD;\;3.69{\pm}0.26,\;OMP-{\beta}-CD;\;4.08{\pm}0.21,\;OMP-CHL;\;4.36{\pm}0.25\;and\;omeprazole\;sodium(OMP-Na);\;3.64{\pm}0.37)$ were higher than that of OMP $(2.66{\pm}0.47)$. OMP was not completely dissolved until even 3 hrs, but all the OMP complexes studied were released about 100% in 20 min. The rectal suppositories containing OMP or each above OMP complex were prepared using Witepsol H-15 base, and their dissolution and stability were examined, and pharmacokinetic study were investigated after their rectal administrations to the rabbits. While the suppository containing OMP was released only less than 60% in 150 min, $OMP-{\beta}-CD$, OMP-CHL, OMP-Na and OMP-ED suppositories were all released about 65% in 20 min. Especially, OMP-HPCD suppository released OMP about 70% in 10 min. All the additives such as sodium laurylsulfate, eglumine, arginine and PVP increased drug release from OMP-HPCD suppository to some extent. The decomposition rate constants of OMP in the suppositories were $9.117{\times}10^{-3}\;day^{-l}$ for OMP suppository, $2.121{\times}10^{-2}$ for OMP-HPCD, $1.607{\times}10^{-2}$ for $OMP-{\beta}-CD$, $9.26{\times}10^{-3}$ for OMP-Na, $6.769{\times}10^{-3}$ for OMP-CHL and $5.58{\times}10^{-3}\;day^{-l}$ for OMP-ED suppository, respectively. Additives such as arginine, eglumine and ED had some stabilizing effect for OMP-HPCD, OMP-CHL and OMP-Na suppositories, respectively. After 6 month-storage at $30^{\circ}C$, 75% RH, OMP-CHL suppository was most stable. The values of Tmax for OMP-HPCD and OMP-Na suppositories were $11.7{\pm}2.36\;and\;11.4{\pm}2.56\;min$, respectively. The values of Cmax for OMP-HPCD and OMP-CHL suppository were $2.31\;{\mu}g/ml\;(p<0.01)\;and\;1.89\;{\mu}g/ml\;p<0.01)$, respectively. The values of AUC for OMP and $OMP-{\beta}-CD$ suppository were $61.9{\pm}25.79\;and\;68.6{\pm}29.48\;{\mu}g\;{\cdot}\;min/ml$, and the corresponding values for OMP-HPCD and OMP-CHL were $106.1{\pm}43.16\;(p<0.05)\;and\;127.3{\pm}42.52\;{\mu}g\;{\cdot}\;min/ml(p<0.01)$, respectively. The above results indicate the OMP-HPCD and OMP-CHL suppositories have the excellent bioavailabilties in vivo study.

  • PDF

Enhanced Nasal Absorption of Ketoconazole by Inclusion with Cyclodextrin (시클로덱스트린과의 포접에 의한 케토코나졸의 비점막 흡수증가)

  • Park, Gee-Bae;Seo, Bo-Youn;Ann, Hong-Jik;Rho, Hyun-Goo;Onn, Yun-Sung;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.95-104
    • /
    • 1994
  • Inclusion complexes of ketoconazole(KT) with ${\alpha}^_$, ${\beta}^_$cyclodextrin(CD) and $dimethy1-{\beta}-cyclodextrin$ (CD) and $dimethy1-{\beta}-cyclodextrin(DM{\beta}CD)$ as nasal absorption enhancer were prepared in 1: 2 molar ratios by freeze-drying and solvent evaporation methods. In order to compare with the intrinsic absorptivity of KT in the jejunum(J) and the nasal cavity(N), the in situ simultaneous perfusion method was employed. The in situ recirculation study revealed that KT-CD inclusion complexes with the greater stability constant and the faster dissolution rate proportionally increased the absorption of KT in the J and N of rats. The rank order of apparent KT permeability$(P_{app}\;:\;cm/sec\;{\time}\;1O^{-5}{\pm}S.E.)$, corrected by surface area of absorption, was $5.10{\pm}0.3(N,\; KT-DM{\beta}CD)$ )> $4.13{\pm}0.4(N,\;KT-{\beta}-CD)$ )> $3.52{\pm}0.2(N,\;KT-{\alpha}-CD)$ )> $2.76{\pm}0.3(J,\; KT-DM{\beta}CD)$ )> $2.61{\pm}0.5(J,\;KT-{\beta}-CD)$ )> $2.42{\pm}0.4(J,\;KT-{\alpha}-CD)$ at pH 4.0. The in crease in permeability of $KT-DM{\beta}CD$ inclusion complex was 2.6 folds in the J and 4.5 folds in the N when the perfusing solution was changed from the buffer(pH 4.0) to saline. The absorption rate of $KT-DM{\beta}CD$ inclusion complex after nasal administration was more rapid than those of ketoconazole alone and $KT-DM{\beta}CD$ inclusion complex after oral administration to rats. In comparision with an oral administration of ketoconazole suspension in corn oil, the relative bioavailability was calculated 137.3% for the oral and 195.0% for nasal $KT-DM{\beta}CD$ inclusion complex in rats. The present results suggest that $KT-DM{\beta}CD$ inclusion complex may serve as a potential nasal absorption enhancer for the nasal delivery of ketoconazole.

  • PDF

PHENOLOXIDASE AND ANTIOXIDANT IN KOREAN GINSENG (고려인삼에 있어서의 페놀 산화효소의 항산화물질)

  • Park E.Y.;Luh B.S.;Branen A.L.
    • Proceedings of the Ginseng society Conference
    • /
    • 1984.09a
    • /
    • pp.257-275
    • /
    • 1984
  • Enzymatic browning is considered desirable in tea and tobacco processing but undesirable in many fruits processing at the present time. It is necessary to understand the nature of the enzyme, phenoloxidase, in order to control browning reactions, and extend its effects to formation of browning products as antioxidants in ginseng. Ginseng exhibits antioxidant activity when incorporated with turkey dark meat patties. The activity in red ginseng showed about two times stronger than white ginseng. One of the phenolic antioxidants from fresh, white and reprocessed white ginseng was identified as phenol 2.6 Bis(1.1 dimethyl ethyl) 4-methyl among several unknown compounds by GC/mass spectrometer. In red ginseng, no phenol 2.6 Bis (1.1 dimethyl ethyl) 4-methyl was detected, the compound may be polymerized by phenoloxidase and form some higher molecular compounds which may possess high antioxidant activity. Phenoloxidase isozymes in fresh Korean ginseng (panax ginseng C.A. Meyer) were extracted with phosphate buffer at pH 7.3. The isozymes were purified through ammonium sulfate fractionation, dialysis and chromatography on a DEAE-cellulose column. Two groups of phenoloxidase were shown to be present, one in the floating agglomerated group and the other in the precipitate. group from the 0.85 saturation ammonium sulfate. The DEAE-cellulose column chromatography, the phenoloxidase isozyme present in the precipitate appears as the first peak (I), and that in the agglomerate in the second peak (II). Isozyme I showed higher activity with catechin and catechal, and isozyme II showed higher activity with p-cresol. The isozyme showed two optimum pH activity one at pH 4.5 and the other at 8.5 with catechin as substrate. Korean ginseng phenoloxidase has high heat stability. When heated at $75^{\circ}C$ for 2 hours, its activity remained $90\%\;and\;80\%$ on phenoloxidase I and II respectively. Phenoloxidase I was most active on (+) catechin followed by p-cresal, catechol and epicatechin. Phenoloxidase II was most active on p-cresal followed by (+) catechin, catechol, p-coumanic acid and epicatechin. Sodium bisulfite, sodium cyanide, ascorbic acid glutachion in the oxidized form, sodium diethyl dithiocarbomate and ethylendiamine tetra acetate (EDTA) acted as inhibitors. Red ginseng color development was initiated by phenoloxidase and finished by a followed sun drying process. The antiaging activity of ginseng may be initiated by the antioxidant in the ginseng.

  • PDF

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

Influence of the RF Power on the Optical and Electrical Properties of ITZO Thin Films Deposited on SiO2/PES Substrate (RF파워가 SiO2/PES 기판위에 증착한 ITZO 박막의 광학적 및 전기적 특성에 미치는 효과)

  • Choi, Byeong-Kyun;Joung, Yang-Hee;Kang, Seong-Jun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.443-450
    • /
    • 2021
  • After selecting a PES substrate with excellent thermal stability and optical properties among plastic substrates, a SiO2 thin film was deposited as a buffer layer to a thickness of 20nm by plasma-enhanced chemical vapor deposition to compensate for the high moisture absorption. Then, the ITZO thin film was deposited by a RF magnetron sputtering method to investigate electrical and optical properties according to RF power. The ITZO thin film deposited at 50W showed the best electrical properties such as a resistivity of 8.02×10-4 Ω-cm and a sheet resistance of 50.13Ω/sq.. The average transmittance of the ITZO thin film in the visible light region(400-800nm) was relatively high as 80% or more when the RF power was 40 and 50W. Figure of Merits (ΦTC and FOM) showed the largest values of 23.90×10-4-1 and 5883 Ω-1cm-1, respectively, in the ITZO thin film deposited at 50W.

Comparison and evaluation of 89Zr-labeled trastuzumab and Thio-trastuzumab : a potential immuno-PET probe for HER2-positive carcinomas

  • Un Chol Shin;Seoku Bae;Suk-man Kim;Min-Woo Lee;Han Sang Jin;Hyun Park;Kyo Chul Lee;Jung Young Kim;Ji Woong Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.105-111
    • /
    • 2021
  • 89Zr is a positron-emitting radioisotope, which has known as well-suited radioisotope for use in a monoclonal antibody-based imaging agent for immuno-PET. The purpose of this study was to quantitatively evaluate the diagnostic ability of general trastuzumab and thio-trastuzumab as HER2 positive receptors based on Df hexadentate iron chelator. Desferrioxamine-p-SCN (Df-Bz-NCS) and desferroixamine-maleimide (Df-Mal) were purchased from Macrocyclics (Dallas, TX, USA). The trastuzumab was purchased from Roche (Schweiz), and thio-trastuzumab was obtained from professor Hyo-Jeong Hong group (Kangwon National University). The radioisotope 89Zr was produced by domestic purification system and KIRAMS using medical cyclotron (50 MeV, Scantronix). The conjugates of Df-trastuzumab and Df-thio-trastuzumab were prepared with Df-Bz-NCS and Df-Mal under basic aqueous solution (pH 8-9) at room temperature, respectively. The conjugates purified by PD-10 column were mixed with dried 89Zr chloride. 89Zr-labeled conjugates were purified and concentrated by Amicon ultra centrifugal filter. The preparation step and time of 89Zr-labeled conjugates was shorted as 4 steps within 2 hours. 89Zr-labeled conjugates showed the highly radiochemical purity of over 98%, and were very stable until 7 days by the analysis of radio-ITLC method. Each radio-labeled conjugates were also exhibited the highly stability in both PBS buffer and mouse serum. Immuno-PET imaging of 89Zr-labeled conjugates in mice bearing gastric cancer xenograft tumors with HER2 expression showed high tumor uptake in the NCI-N87 HER2-expressing. However, 89Zr-Df-Mal-thio-trastuzumab showed a relatively lower tumor-to-background ratio than 89Zr-Df-Bz-trastuzumab, as well as whole-body distribution. In the results, 89Zr-Df-Bz-trastuzumab was evaluated to have a relatively higher HER2 diagnostic ability than 89Zr-Df-Mal-thio-trastuzumab.

Application of Micro Porous Layer (MPL) for Enhance of Electrode Performance in Phosphoric Acid Fuel Cells (PAFCs) (인산형 연료전지(PAFC)의 전극 성능 향상을 위한 미세다공층(MPL)의 적용)

  • Jihun Ha;Sungmin Kang;You-Kwan Oh;Dong-Hyun Peck
    • Journal of the Korean Electrochemical Society
    • /
    • v.27 no.1
    • /
    • pp.32-39
    • /
    • 2024
  • The key components of a Phosphoric acid fuel cell (PAFC) are an electrode catalyst, an electrolyte matrix and a gas diffusion layer (GDL). In this study, we introduced a microporous layer on the GDL of PAFC to enhance liquid electrolyte management and overall electrochemical performance of PAFC. MPL is primarily used in polymer electrolyte membrane fuel cells to serve as an intermediate buffer layer, effectively managing water within the electrode and reducing contact resistance. In this study, electrodes were fabricated using GDLs with and without MPL to examine the influence of MPL on the performance of PAFC. Internal resistance and polarization curves of the unit cell were measured and compared to each other to assess the impact of MPL on PAFC electrode performance. As the results, the application of MPL improved power density from 170.2 to 192.1 mW/cm2. MPL effectively managed electrolyte and water within the matrix and electrode, enhancing stability. Furthermore, the application of MPL reduced internal resistance in the electrode, resulting in sustained and stable performance even during long-term operation.

Characterization of Carbamazepine-Imprinted Acorn Starch/PVA-Based Biomaterials (카바마제핀 각인 도토리 전분/PVA 기반 바이오소재의 특성)

  • Kyeong-Jung Kim;Ji-Hoon Kang;Bo-Gyeong Kim;Min‑Jin Hwang;Soon-Do Yoon
    • Applied Chemistry for Engineering
    • /
    • v.35 no.3
    • /
    • pp.192-199
    • /
    • 2024
  • In this study, carbamazepine (CBZ) imprinted starch/PVA-based biomaterials were prepared by the casting method and UV irradiation, and their physicochemical properties, CBZ adsorption ability, and release properties were investigated. The surface properties of the prepared biomaterials were characterized using FE-SEM, while the stability of CBZ under UV irradiation and the functional groups of the biomaterials were characterized using FT-IR analysis. The adsorption properties of CBZ on the biomaterials were evaluated by binding isotherm and Scatchard plot. Results indicate that CBZ imprinted biomaterials possess a specific binding site of CBZ. To evaluate the applicability of the transdermal drug delivery system, the release properties of CBZ from prepared biomaterials using various pH buffers and artificial skin at 36.5 ℃ were investigated. Results indicated that the CBZ release at high pH was faster than at low pH. In addition, CBZ was released continuously for 12 h in the artificial skin test. The drug release mechanism of CBZ followed a pseudo-Fickian diffusion mechanism in buffer solution, whereas the release from artificial skin exhibited a non-Fickian diffusion mechanism.