• Title/Summary/Keyword: Buck regulator

Search Result 39, Processing Time 0.029 seconds

A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter (2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템)

  • Lee, Sang-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.96-106
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system. Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system. In the case of diode rectifier system of phase controlled converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, two stage three phase PWM AC/DC converter is studied to solve these problems. The characteristics of a proposed converter reduces the harmonics and reactive power of the distribution line and has fast dynamic response in transient period using boost converter and current control mode buck converts. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

Regulated Peak Power Tracking (RPPT) System Using Parallel Converter Topologies

  • Ali, Muhammad Saqib;Bae, Hyun-Su;Lee, Seong-Jun;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.870-879
    • /
    • 2011
  • Regulated peak power tracking (RPPT) systems such as the series structure and the series-parallel structures are commonly used in satellite space power systems. However, these structures process the solar array power or the battery power to the load through two cascaded regulators during one orbit cycle, which reduces the energy transfer efficiency. Also the battery charging time is increased due to placement of converter between the battery and the solar array. In this paper a parallel structure has been proposed which can improve the energy transfer efficiency and the battery charging time for satellite space power RPPT systems. An analogue controller is used to control all of the required functions, such as load voltage regulation and solar array stabilization with maximum power point tracking (MPPT). In order to compare the system efficiency and the battery charging efficiency of the proposed structure with those of a series (conventional) structure and a simplified series-parallel structure, simulations are performed and the results are analyzed using a loss analysis model. The proposed structure charges the battery more quickly when compared to the other two structures. Also the efficiency of the proposed structure has been improved under different modes of solar array operation when compared with the other two structures. To verify the system, experiments are carried out under different modes of solar array operation, including PPT charge, battery discharge, and eclipse and trickle charge.

A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter (전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한 연구)

  • 장수진;류동균;서민성;김준호;원충연;이진국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.32-39
    • /
    • 2003
  • The output voltage of synchronous generator is regulated constantly by field current control in excitation system High frequency PWM converter (current control mode buck converter) type excitation systam fer synchronous generator is able to control exciter current when the load change happened. This paper deals with the design and evaluation of the excitation system for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is able to improve the response time by the DVR(digital voltage regulator) of 50[kW] synchronous generator.

The Stablity and Transient Response in the Buck-Boost DC-DC Converter (승강엽형 DC-DC 콘버어터의 안정도 및 과도 응답)

  • 김희준;김순창
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.5
    • /
    • pp.421-430
    • /
    • 1991
  • This paper investigated the errect of the right-half-plane zero on stability in the buck-boost DC-DC converter which is one type of the switching regulator and the stability region for the variation of the output current is obtained by evaluating the feedback gain. And it is clarified that the damping ratio decreases gradually by increase of the feedback loop gain and the regulation system of the converter becomes unstable, and from the transient response analysis we obtainedthe stability region about this converter. From above result it is known that the stability decreases by the existence of the right-half-plane zero. For the improvement of stability, we carried out one pole compensation in feedback circuit and obtained the avaliable stability region in relation to the gain bandwidth product from the stability and transient response analysis. These results were established experiment.

  • PDF

Universal power converter using High-Speed Switching (고속 스위칭에 의한 만능 전려변화기 구성)

  • Isnanto, Isnanto;Budhi, Prayoga;Choi, Woo-seok;Park, Sung-jun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.337-338
    • /
    • 2013
  • Combination the several type of single phase power conversion utilized simply topology are proposed in this paper. Totally four kind of converter are investigated, they are Boost AC/AC Converter, Buck AC/AC Converter, Boost AC/DC Converter, and Buck DC/AC Converter. Two types action mode are presented to determine the functional of circuit. First is AC chopper action mode, representation of the AC/AC converter. AC chopper action mode offered the sinusoidal current waveform, better power factor, faster dynamics, and smaller input/output filter. They present high robustness, offer safe commutation and have high efficiency. The second is full bridge action mode, determined the transformation AC to DC power and otherwise. Four switching devices and one magnetic contactor will establish the mode operation of circuit and manage the flow of power proceed in proper. The correction and advance of the kind of converter are verified by simulation.

  • PDF

A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter (전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF

A Controller Design for Switching Regulator Using an Optimal Output PIM Control with Feedforward Comensation (입력보상 및 최적 출력 PIM 제어를 적용한 스위칭 직류 변환기의 제어기 설계)

  • 고정호;권봉환;윤명중
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.3
    • /
    • pp.188-196
    • /
    • 1987
  • This paper describes a design method for the buck type switching regulator to improve transient and steady state performances. Necessary design considerations on the power stage are given before designing the controller to obtain better trandient responses with less control effort and a feedforward compensation is also given to effectively improve the steady state performance. In the design of the controller, a PIM (proportional-integral-measurable) control method with optimized constant feedback gains is presented to get better tansient and steady state performances without complicating the implementation of controller. Computer simulations and experimental results are given to show the usefulness of the presented technique.

  • PDF

A Study on the transient response in the switching regulator (스위칭 레귤레이터에 있어서 과도응답에 대한 연구)

  • Kim, Hee-Jun;Kim, Soon-Chang
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.235-239
    • /
    • 1989
  • This paper investigated the effect of right half plane zero on the transient response in the buck-boost DC-DC converter. And it is clarified that the damping ratio decreases gradually by increases of the feedback loop gain and the regulation system of the converter becomes unstable. From the result, we obtained the stability region about the duty ratio and the output current by evaluating the feedback loop gain.

  • PDF

Improving the Light-Load Efficiency of a LDO-Embedded DC-DC Buck Converter Using a Size Control Method of the Power-Transistor (파워 트랜지스터 사이즈 조절 기법을 이용한 LDO 내장형 DC-DC 벅 컨버터의 저부하 효율 개선)

  • Kim, Hyojoong;Wee, Jaekyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.59-66
    • /
    • 2015
  • In this paper, we propose a method of improving the light-load efficiency of DC-DC buck converter using 4bit SAR-ADC (Successive Approximation ADC) for a LDO or a power transistor size selection technique. The proposed circuit selects power transistor sizes depending on load current so that improves the light-load efficiency of the DC-DC buck converter. For this, we select the power transistor size with a cross point of the switching loss and the conduction loss. Also, when the IC operates in standby mode or sleep mode, a LDO mode is selected for improving the efficiency. The proposed circuit selects power transistor sizes(X1, X2, X4, X8) with 4 bits and its efficiency is higher about the maximum of 25% at the light-load than that of a single transistor size. Input voltage and output voltage are 5V and 3.3V for maximum load currents of 500mA.

The Design of DC-DC Converter with Green-Power Switch and DT-CMOS Error Amplifier (Green-Power 스위치와 DT-CMOS Error Amplifier를 이용한 DC-DC Converter 설계)

  • Koo, Yong-Seo;Yang, Yil-Suk;Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.90-97
    • /
    • 2010
  • The high efficiency power management IC(PMIC) with DTMOS(Dynamic Threshold voltage MOSFET) switching device and DTMOS Error Amplifier is presented in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS(DT-CMOS) with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuits consist of a saw-tooth generator, a band-gap reference circuit, an DT-CMOS error amplifier and a comparator circuit as a block. the proposed DT-CMOS Error Amplifier has 72dB DC gain and 83.5deg phase margin. also Error Amplifier that use DTMOS more than CMOS showed power consumption decrease of about 30%. DC-DC converter, based on Voltage-mode PWM control circuits and low on-resistance switching device is achieved the high efficiency near 96% at 100mA output current. And DC-DC converter is designed with Low Drop Out regulator(LDO regulator) in stand-by mode which fewer than 1mA for high efficiency.