• Title/Summary/Keyword: Bridge effect

Search Result 1,551, Processing Time 0.025 seconds

Behavior of steel-concrete composite cable anchorage system

  • Gou, Hongye;Wang, Wei;Shi, Xiaoyu;Pu, Qianhui;Kang, Rui
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.115-123
    • /
    • 2018
  • Steel-concrete composite structure is widely applied to bridge engineering due to their outstanding mechanical properties and economic benefit. This paper studied a new type of steel-concrete composite anchorage system for a self-anchored suspension bridge and focused on the mechanical behavior and force transferring mechanism. A model with a scale of 1/2.5 was prepared and tested in ten loading cases in the laboratory, and their detailed stress distributions were measured. Meanwhile, a three-dimensional finite element model was established to understand the stress distributions and validated against the experimental measurement data. From the results of this study, a complicated stress distribution of the steel anchorage box with low stress level was observed. In addition, no damage and cracking was observed at the concrete surrounding this steel box. It can be concluded that the composite effect between the concrete surrounding the steel anchorage box and this steel box can be successfully developed. Consequently, the steel-concrete composite anchorage system illustrated an excellent mechanical response and high reliability.

Control effect and mechanism investigation on the horizontal flow-isolating plate for PI shaped bridge decks' VIV stability

  • Li, Ke;Qian, Guowei;Ge, Yaojun;Zhao, Lin;Di, Jin
    • Wind and Structures
    • /
    • v.28 no.2
    • /
    • pp.99-110
    • /
    • 2019
  • Vortex-Induced-Vibration (VIV) is one kind of the wind-induced vibrations, which may occur in the construction and operation period of bridges. This phenomenon can bring negative effects to the traffic safety or can cause bridge fatigue damage and should be eliminated or controlled within safe amplitudes.In the current VIV studies, one available mitigation countermeasure, the horizontal flow-isolating plate, shows satisfactory performance particularly in PI shaped bridge deck type. Details of the wind tunnel test are firstly presented to give an overall description of this appendage and its control effect. Then, the computational-fluid-dynamics(CFD) method is introduced to investigate the control mechanism, using two-dimensional Large-Eddy-Simulation to reproduce the VIV process. The Reynolds number of the cases involved in this paper ranges from $1{\times}10^5$ to $3{\times}10^5$, using the width of bridge deck as reference length. A field-filter technique and detailed analysis on wall pressure are used to give an intuitive demonstration of the changes brought by the horizontal flow-isolating plate. Results show that this aerodynamic appendage is equally effective in suppressing vertical and torsional VIV, indicating inspiring application prospect in similar PI shaped bridge decks.

Effects of Bridge Exercise Combined with Vibration on Abdominal Muscle Thickness (진동을 병행한 교각운동이 복부 근육 두께에 미치는 영향)

  • Jae Cheol Park;Jin Gyu Jeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2023
  • Background: The purpose of this study was to confirm the effect of bridge exercise combined with vibration on abdominal muscle thickness. Design: Randomized controlled trial. Methods: As study subjects, 24 adults in their 20s were classified into 12 vibration bridge exercise groups and 12 bridge exercise groups. The time was divided into before the experiment, 3 weeks after the experiment, and 6 weeks after the experiment. Two-way repeated ANOVA was used to examine changes in the muscle thickness of the external oblique, internal oblique, and transverse abdominal muscles of the trunk muscles, and the significance level was set at 0.05. If there was an interaction between time and group, post-hoc analysis was performed, and the significance level was set at 0.01. Results: There was a significant difference in the external oblique muscle in the change by period, the interaction between time and group, and the change between groups (p<0.05). There was a significant difference in the external oblique muscle in the change by period, the interaction between time and group, and the change between groups (p<0.05). Conclusion: As a result of this study, bridge exercise combined with vibration had a positive effect on the muscle thickness of the external oblique, internal oblique, and transversus abdominis muscles. It suggests the possibility of using the basic data of vibration exercise and the lumbar stabilization exercise in clinical practice.

Effect on Activation of Abdominal Local Muscles During Modified Bridge Exercise in Healthy Individuals (변형된 교각운동이 복부 국소근육의 활성화에 미치는 효과)

  • Han, J.H.;Sung, Y.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.3
    • /
    • pp.215-222
    • /
    • 2015
  • The purpose of this study was to investigate abdominal local muscle activity during modified bridge exercise. 17 subjects participated in this study. Abdominal muscles measured. External oblique abdominis (EO), internal oblique abdominis (IO), transvers abdominis (TrA), and rectus abdominis (RA) during general bridge exercise and modified bridge exercise, respectively. Electromyogram (EMG) and real-time ultrasound were used to verify alteration of muscles. Activation of RA and EO muscles of non-dominant foot was significantly difference in general bridge exercise group, not modifiedl bridge exercise group. In the modified bridge exercise group, thickness of IO and TrA muscle of non-dominant foot was significantly difference in modified bridge exercise group than general bridge exercise group. Therefore, modified bridge exercise may be apply as more effective exercise for local muscle activity than global muscle.

  • PDF

Effect of vehicle flexibility on the vibratory response of bridge

  • Lalthlamuana, R.;Talukdar, Sudip
    • Coupled systems mechanics
    • /
    • v.3 no.2
    • /
    • pp.147-170
    • /
    • 2014
  • In the recent times, dimensions of heavy load carrying vehicle have changed significantly incorporating structural flexibility in vehicle body. The present paper outlines a procedure for the estimation of bridge response statistics considering structural bending modes of the vehicle. Bridge deck roughness has been considered to be non homogeneous random process in space. Influence of pre cambering of bridge surface and settlement of approach slab on the dynamic behavior of the bridge has been studied. A parametric study considering vehicle axle spacing, mass, speed, vehicle flexibility, deck unevenness and eccentricity of vehicle path have been conducted. Dynamic amplification factor (DAF) of the bridge response has been obtained for several of combination of bridge-vehicle parameters. The present study reveals that flexible modes of vehicle can reduce dynamic response of the bridge to the extent of 30-37% of that caused by rigid vehicle model. However, sudden change in the bridge surface profile leads to significant amount of increment in the bridge dynamic response even if flexible bending modes remain active. The eccentricity of vehicle path and flexural/torsional rigidity ratios plays a significant role in dynamic amplification of bridge response.

Vertical vibrations of a bridge based on the traffic-pavement-bridge coupled system

  • Yin, Xinfeng;Liu, Yang;Kong, Bo
    • Earthquakes and Structures
    • /
    • v.12 no.4
    • /
    • pp.457-468
    • /
    • 2017
  • When studying the vibration of a suspension bridge based on the traffic-bridge coupled system, most researchers ignored the contribution of the pavement response. For example, the pavement was simplified as a rigid base and the deformation of pavement was ignored. However, the action of deck pavement on the vibration of vehicles or bridges should not be neglected. This study is mainly focused on establishing a new methodology fully considering the effects of bridge deck pavement, probabilistic traffic flows, and varied road roughness conditions. The bridge deck pavement was modeled as a boundless Euler-Bernoulli beam supported on the Kelvin model; the typical traffic flows were simulated by the improved Cellular Automaton (CA) traffic flow model; and the traffic-pavement-bridge coupled equations were established by combining the equations of motion of the vehicles, pavement, and bridge using the displacement and interaction force relationship at the contact locations. The numerical studies show that the proposed method can more rationally simulate the effect of the pavement on the vibrations of bridge and vehicles.

Evaluation of Dorim-Goh bridge using ambient trucks through short-period structural health monitoring system

  • Kaloop, Mosbeh R.;Hwang, Won Sup;Elbeltagi, Emad;Beshr, Ashraf;Hu, Jong Wan
    • Structural Engineering and Mechanics
    • /
    • v.69 no.3
    • /
    • pp.347-359
    • /
    • 2019
  • This paper aims to evaluate the behavior of Dorim-Goh bridge in Seoul, Korea, under static and dynamic loads effects by ambient trucks. The prestressed concrete (PSC) girders and reinforcement concrete (RC) slab of the bridge are evaluated and assessed. A short period monitoring system is designed which comprises displacement, strain and accelerometer sensors to measure the bridge performance under static and dynamic trucks loads. The statistical analysis is used to assess the static behavior of the bridge and the wavelet analysis and probabilistic using Weibull distribution are used to evaluate the frequency and reliability of the dynamic behavior of the bridge. The results show that the bridge is safe under static and dynamic loading cases. In the static evaluation, the measured neutral axis position of the girders is deviated within 5% from its theoretical position. The dynamic amplification factor of the bridge girder and slab are lower than the design value of that factor. The Weibull shape parameters are decreased, it which means that the bridge performance decreases under dynamic loads effect. The bridge girder and slab's frequencies are higher than the design values and constant under different truck speeds.

Effect of Trunk Inclination Angles on Trunk Muscle Activity and Subjective Difficulties During Supine Bridge Exercise with a Suspension Device

  • Kim, Jwa-Jun;Park, Se-Yeon
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.315-321
    • /
    • 2020
  • Purpose: Recent studies have indicated that applying different inclination angles and suspension devices could be a useful way of performing exercises that include the co-activation of the trunk muscles. Present study was to examine the influences of changes in the inclination angle during trunk muscle activity while engaging in a bridge exercise with a suspension device. Methods: 18 healthy, physically active male volunteers completed three trunk inclination angles (15°, 30°, and 45°) for bridge exercise variations. The surface electromyography responses of the rectus abdominis, internal oblique (IO), erector spinae (ES), and rectus femoris (RF), as well as the subjective difficulty (Borg RPE score), were investigated during these bridge exercises. Results: The bridge with a 45° inclination angle suspension significantly increased the muscular activities of the RA and RF and increased the Borg RPE scores (p<0.05). The bridge with a 15° suspension significantly elevated the ES activities when compared to the other conditions. Conclusion: The present study demonstrated that a higher inclination angle could not activate the overall trunk muscles during the bridge exercise. The RA and RF produced greater activation during the bridge exercise with the higher inclination angle. On the other hand, the activities of the erector spine were greater during the bridge exercise with the lower inclination angle. The present study suggests that applying a low trunk inclination angle for the supine bridge exercise is suitable for activating the erector spine muscles.

An evaluation system for determining the stress redistribution of a steel cable-stayed bridge due to cable stress relaxation at various temperatures

  • Tien-Thang Hong;Duc-Kien Thai;Seung-Eock Kim
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.805-821
    • /
    • 2023
  • This study developed an evaluation system to explore the effect of the environmental temperature on the stress redistribution produced by cable stress relaxation of structural members in a steel cable-stayed bridge. The generalized Maxwell model is used to estimate stress relaxation at different temperatures. The environmental temperature is represented using the thermal coefficients and temperature loads. The fmincon optimization function is used to determine the set of stress relaxation parameters at different temperatures for all cables. The ABAQUS software is employed to investigate the stress redistribution of the steel cable-stayed bridge caused by the cable stress relaxation and the environmental temperature. All of these steps are set up as an evaluation system to save time and ensure the accuracy of the study results. The developed evaluation system is then employed to investigate the effect of environmental temperature and cable type on stress redistribution. These studies' findings show that as environmental temperatures increased up to 40 ℃, the redistribution rate increased by up to 34.9% in some girders. The results also show that the cable type with low relaxation rates should be used in high environmental temperature areas to minimize the effect of cable stress relaxation.

Comparison of the dynamic responses of $G\ddot{u}lburnu$ Highway Bridge using single and triple concave friction pendulums

  • Yurdakul, Muhammet;Ates, Sevket;Altunisik, Ahmet Can
    • Earthquakes and Structures
    • /
    • v.7 no.4
    • /
    • pp.511-525
    • /
    • 2014
  • The main object of this study is to determine and compare the structural behavior of base isolated long span highway bridge, $G\ddot{u}lburnu$ Highway Bridge, using single concave friction pendulum (SCFP) and triple concave friction pendulum (TCFP). The bridge is seismically isolated in the design phase to increase the main period and reduce the horizontal forces with moments using SCFP bearings. In the content of the paper, firstly three dimensional finite element model (FEM) of the bridge is constituted using project drawings by SAP2000 software. The dynamic characteristics such as natural frequencies and periods, and the structural response such as displacements, axial forces, shear forces and torsional moments are attained from the modal and dynamic analyses. After, FEM of the bridge is updated using TCFP and the analyses are performed. At the end of the study, the dynamic characteristics and internal forces are compared with each other to extract the TCFP effect. To emphasize the base isolation effect, the non-isolated structural analysis results are added to graphics. The predominant frequencies of bridge non-isolated, isolated with SCFP and isolated with TCFP conditions decreased from 0.849Hz to 0.497Hz and 0.338Hz, respectively. The maximum vertical displacements are obtained as 57cm, 54cm and 44cm for non-isolated, isolated with SCFP and isolated with TCFP conditions, respectively. The maximum vertical displacement reduction between isolated with TCFP bearing and isolated with SCFP bearing bridge is %23. Maximum axial forces are obtained as 60619kN, 18728kN and 7382kN, maximum shear forces are obtained as 23408kN, 17913kN and 16249kN and maximum torsional moments are obtained as 24020kNm, 7619kNm and 3840kNm for non-isolated, isolated with SCFP and isolated with TCFP conditions, respectively.