• 제목/요약/키워드: Bridge Buildings

검색결과 146건 처리시간 0.023초

Influence characteristics of isolation piles on deformation of existing shallow foundation buildings under deep excavation

  • Liu, Xinrong;Liu, Peng;Zhou, Xiaohan;Wang, Linfeng;Zhong, Zuliang;Lou, Xihui;Chen, Tao;Zhang, Jilu
    • Geomechanics and Engineering
    • /
    • 제31권1호
    • /
    • pp.1-14
    • /
    • 2022
  • Urban deep excavation will affect greatly on the deformation of adjacent existing buildings, especially those with shallow foundations. Isolation piles has been widely used in engineering to control the deformation of buildings adjacent to the excavation, but its applicability is still controversial. Based on a typical engineering, numerical calculation models were established and verified through monitoring data to study the influence characteristics of isolation piles on the deformation of existing shallow foundation buildings. Results reveal that adjacent buildings will increase building settlement δv and the deformation of diaphragm walls δh, while the isolation piles can effectively decrease these. The surface settlement curve is changed from "groove" type to "double groove" type. Sufficiently long isolation pile can effectively decrease δv, while short isolation piles will lead to a negative effect. When the building is within the range of the maximum settlement location P, maximum building rotation θm will increase with the pile length L and the relative position between isolation pile and building d/D increase (d is the distance between piles and diaphragm walls, D is the distance between buildings and diaphragm walls), instead, θm will decrease for buildings outside the location P, and the optimum was obtained when d/D=0.7.

종합병원의 증축과정에서 동선 중심축 형성을 통한 공간디자인의 문제점 도출과 해결안 제시에 관한 연구 -한양대학교 의과대학 부속병원의 사례- (A study on the solution suggesting and the problem investigating of spatial designing through the axis of circulation in the extension of general hospital - A case study : medical college's hospital of Hanyang University -)

  • 김규성;이정만
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제9권1호
    • /
    • pp.7-15
    • /
    • 2003
  • Contemporary hospital has more and more extension because the growth and change of hospital has to respond the various needs. For expanding, the sky bridge(sky walk) becomes one of the method to interconnect two or more buildings on the air. Sometimes the designers don't know exactly how the sky bridge works after construction. Beyond the role of interconnecting two buildings, the role of sky bridge is transformed the main axis of pedestrian in the whole hospital organization. This scope of analysis is about the sky bridge of Hanyang University hospital. The first method is the investigation of the utilization in this time. The second is the analysis of design drawings got form the designing of the past(1994-1998). From this analysis, the conclusions are followings.;The designer who wants to apply the sky bridge should more consider about, 1) how the sky bridge impacts the whole spatial system such as the pedestrian, patients, physicians, service's facilities etc. 2) what the inside of sky bridge has something such as natural light, ventilation, and the height, depth, width of aisle, the sign for seeking orientation. etc. In future the research relating sky bridge should be studied some hospital as well as one hospital for comparing the characteristics of the concepts and organizations

  • PDF

면진장치 장착 스카이 브릿지의 사용성 평가 (Serviceability Evaluation of Sky Bridge With Isolation Device)

  • 김기철;김현수;김수근
    • 한국공간구조학회논문집
    • /
    • 제17권2호
    • /
    • pp.71-77
    • /
    • 2017
  • In this study, the boundary non-linear analysis of the sky bridge subjected to walking load and running load is performed. The sky bridge is installed in the mid-story between two buildings and the walking load and running load induced by pedestrians are measured by load cell. LRB is modeled as a non-linear hysteresis model to accurately represent the behavior of LRB. For the serviceability evaluation of sky bridge, the acceleration responses of sky bridge are analyzed based on ISO 2631-2 and the velocity response are analyzed based on standards Bachmann &Amann. In serviceability evaluation of this sky bridge, the pedestrian can not perceive the vibration except for resonance running loads consequently. Therefore, it is concluded that this sky bridge haven't problem in the serviceability.

스카이브릿지 설치위치에 따른 고층건물의 진동제어 성능평가 (Performance Evaluation of Vibration Control According to Installation Location of a Sky-bridge)

  • 김현수;박용구;고현;이의현;이동근
    • 한국공간구조학회논문집
    • /
    • 제10권3호
    • /
    • pp.65-74
    • /
    • 2010
  • 본 연구에서는 스카이브릿지 설치위치 및 연결된 구조물의 고유진동주기 차이에 따른 전체 구조물의 진동제어 효과를 분석하였다. 이를 위하여 스카이브릿지로 연결된 40층과 50층 구조물을 예제 구조물로 사용하였고, 등가모형화기법을 이용하여 예제 모델을 구성하였다. El Centro 및 Taft 지진을 사용하여 경계비선형 시간이력해석을 수행하였고 구조물의 동적거동과 진동제어 효과를 분석하였다. 해석결과 변위응답은 스카이브릿지를 상부층에 설치할수록 더 효과적으로 제어할 수 있었고 가속도응답은 구조물의 중간층부근에 설치할 때 더 효과적으로 저감시킬 수 있었다.

  • PDF

모듈러 주택의 열교 및 결로 취약부위별 단열성능 분석 (Insulation Performance Analysis of Vulnerable Parts of Thermal Bridge and Condensation in Modular Buildings)

  • 김미연;김형근;박진철
    • 한국건설관리학회논문집
    • /
    • 제22권3호
    • /
    • pp.31-39
    • /
    • 2021
  • 모듈러 공법은 내장재와 기계·전기 설비 등이 시공된 구조체를 제작 공장에서 건설 현장으로 운반하여 설치 및 시공하는 공법이다. 모듈러 공법은 특히 주택과 같은 소규모의 비교적 구조가 간단한 건축물을 대상으로 활발하게 적용되고 있는 추세이다. 국내건설 산업에 모듈러 주택의 도입된 기간이 길지 않은 만큼 아직 모듈러 주택의 환경적 특성에 대한 연구가 부족한 실정이다. 따라서 본 연구의 목적은 모듈러 주택의 단열성능을 적외선 이미지 분석과, Air-Surface Thermal Ratio 방법, 실내외 온도차비를 활용하여 실증적으로 분석하는 것이다. 이를 위해 실제 서울시에 위치한 준공 후 2년이 경과된 모듈러 주택과 RC 주택을 비교하여 단열성능 분석하였다.

A Kalman filter based algorithm for wind load estimation on high-rise buildings

  • Zhi, Lun-hai;Yu, Pan;Tu, Jian-wei;Chen, Bo;Li, Yong-gui
    • Structural Engineering and Mechanics
    • /
    • 제64권4호
    • /
    • pp.449-459
    • /
    • 2017
  • High-rise buildings are generally sensitive to strong winds. The evaluation of wind loads for the structural design, structural health monitoring (SHM), and vibration control of high-rise buildings is of primary importance. Nevertheless, it is difficult or even infeasible to measure the wind loads on an existing building directly. In this regard, a new inverse method for evaluating wind loads on high-rise buildings is developed in this study based on a discrete-time Kalman filter. The unknown structural responses are identified in conjunction with the wind loads on the basis of limited structural response measurements. The algorithm is applicable for estimating wind loads using different types of wind-induced response. The performance of the method is comprehensively investigated based on wind tunnel testing results of two high-rise buildings with typical external shapes. The stability of the proposed algorithm is evaluated. Furthermore, the effects of crucial factors such as cross-section shapes of building, the wind-induced response type, errors of structural modal parameters, covariance matrix of noise, noise levels in the response measurements and number of vibration modes on the identification accuracy are examined through a detailed parametric study. The research outputs of the proposed study will provide valuable information to enhance our understanding of the effects of wind on high-rise buildings and improve codes of practice.

Structural optimization in practice: Potential applications of genetic algorithms

  • Krishnamoorthy, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제11권2호
    • /
    • pp.151-170
    • /
    • 2001
  • With increasing competition, the engineering industry is in need of optimization of designs that would lead to minimum cost or weight. Recent developments in Genetic Algorithms (GAs) makes it possible to model and obtain optimal solutions in structural design that can be put to use in industry. The main objective of this paper is to illustrate typical applications of GAs to practical design of structural systems such as steel trusses, towers, bridges, reinforced concrete frames, bridge decks, shells and layout planning of buildings. Hence, instead of details of GA process, which can be found in the reported literature, attention is focussed on the description of the various applications and the practical aspects that are considered in Genetic Modeling. The paper highlights scope and future directions for wider applications of GA based methodologies for optimal design in practice.

The Study on Thermal Performance Evaluation of Building Envelope with VIPs

  • Jeon, Wan-Pyo;Kwon, Gyeong-Jin;Kim, Jin-Hee;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: The energy consumption in buildings has continuously increased in some countries and it reaches almost 25% of the total energy use in korea. Therefore there are various efforts to minimize energy consumption in buildings, and the regulations on building envelope insulation have been tightened up gradually. To satisfy the building regulation, the use of vacuum insulation panels(VIPs) is increasing. VIP is a high performance insulation materials, so that it can be thinner than conventional insulation material. When VIP is applied in a building, it may cause thermal bridge, which occurs due to very low thermal conductivity compared to other building materials and the envelope of VIPs. Method: This study designed the capsulized VIPs using conventional insulation for reduction of the thermal bridge. Then designed VIPs were applied to a wall. The linear thermal transmittance and the effective thermal conductivity were analyzed by HEAT2 simulation program for two dimensional steady-state heat transfer. The result compared with a wall with non-capsulized VIPs. Result: It analyzed that the wall with capsulized VIPs had lower linear thermal transmittance and reduced the difference of the effective thermal transmittance with one dimensional thermal transmittance compared to that of the wall with non-capsulized VIPs.

Stable modal identification for civil structures based on a stochastic subspace algorithm with appropriate selection of time lag parameter

  • Wu, Wen-Hwa;Wang, Sheng-Wei;Chen, Chien-Chou;Lai, Gwolong
    • Structural Monitoring and Maintenance
    • /
    • 제4권4호
    • /
    • pp.331-350
    • /
    • 2017
  • Based on the alternative stabilization diagram by varying the time lag parameter in the stochastic subspace identification analysis, this study aims to investigate the measurements from several cases of civil structures for extending the applicability of a recently noticed criterion to ensure stable identification results. Such a criterion demands the time lag parameter to be no less than a critical threshold determined by the ratio of the sampling rate to the fundamental system frequency and is firstly validated for its applications with single measurements from stay cables, bridge decks, and buildings. As for multiple measurements, it is found that the predicted threshold works well for the cases of stay cables and buildings, but makes an evident overestimation for the case of bridge decks. This discrepancy is further explained by the fact that the deck vibrations are induced by multiple excitations independently coming from the passing traffic. The cable vibration signals covering the sensor locations close to both the deck and pylon ends of a cable-stayed bridge provide convincing evidences to testify this important discovery.

사무소 건축물의 단열상황에 관한 조사연구 (Survey Research on Thermal Situation of Office Buildings)

  • 정의인;김봉주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.145-152
    • /
    • 2013
  • 본 논문은 1990년대~2011년 시공 중이었던 건축물의 커튼월의 단열성을 평가하기 위하여 내외 표면 온도를 측정하여 부위별 온도 차이를 분석하였다. 유리면이나 단열층이 있는 표면보다 커튼월의 프레임 (멀리온 및 트랜섬)의 온도는 동절기 외부 평면의 경우 $6^{\circ}C{\sim}10^{\circ}C$ 정도 높게 나타났다. 또한, 같은 프레임에서도 앵커유닛이 있는 부위가 다른 프레임보다 $2^{\circ}C{\sim}3^{\circ}C$ 더 높게 나타나 보다 큰 열 손실이 일어나고 있는 것으로 나타났다.