• 제목/요약/키워드: Bridge Bearing

검색결과 328건 처리시간 0.028초

수직하중 계측을 위한 FBG센서 기반 스마트 교량 내진장치의 개발 (Development of Smart Seismic Device Using FBG Sensor for Measuring Vertical Load)

  • 장성진;김남식;백준호
    • 한국소음진동공학회논문집
    • /
    • 제22권11호
    • /
    • pp.1089-1098
    • /
    • 2012
  • A faulting could be occurred at the end of deck by unexpected loads to bridge bearing after a bridge completion. Serviceability of bridges could be impaired by the faulting which is caused structural damage. Therefore, smart bridge bearing which can continuously observe the supporting points is needed. Some of bridge bearings have been developed for measuring vertical load and vertical displacement by installing sensors in the bearing. In those systems, however it is not easy to be replaced with new sensors when repairs are needed. In this study, the smart bridge bearing of which sensors can be replaced has been developed to overcome such a problem. In this study, strain signals were used for measuring both of vertical displacements and loads. FBG sensors(fiber optic Bragg-grating sensors) have been used for measurement of the strain signals since it is prevented from electronic noise by mediating light, enables the simplification of the measuring cable by multiple measurement, and is easy to place by lightweight and small size. The possibility of use was reviewed for smart bridge bearing based on FBG sensors through tests.

Effect of a two bearing lines deck on the bridge substructure

  • Shaker, Fatemeh;Rahai, Alireza
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.117-129
    • /
    • 2022
  • This research evaluated the different types of deck to pier connections effects (one or two elastomeric bearing lines and rigid) on a concrete bridges. Three-dimensional bridge models behavior with different deck to pier connections and different distances of two bearing lines were studied under the service load. Also, the detailed connection system with two elastomeric bearing lines was modeled to evaluate the effect of changing distance between two-lines. Results indicated that the proper location of elastomeric bearings has a major impact on the transferring forces to the substructure. Double elastomeric bearing lines have a behavior between one line and rigid connections. Transferring bending moment to the substructure in two-lines is more than the corresponding value of the one line. Moreover, an increase in the distance of two-lines lead to a significant increase in the rotational stiffness of the connection, and an analytical solution was investigated for their relation. In fact, the semi-rigidity effect of this connection and its change due to the distance of bearings should be considered in the design process.

분리형 스페리칼 교량받침의 특징 및 교체실험 (Characteristics and Replacement of Separated Spherical Bridge Bearings)

  • 박성우;유승규;최은수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1729-1734
    • /
    • 2008
  • This study developed a new separated shperical bridge bearing that can be used for replacement of existing bridge bearings without crushing bearing-concrete. The separated spherical bearing have the upper and lower sole plate connected by bolts to the upper plate under bridge-girders and the lower plate on bearing-concrete. The targets of the separated spherical bearing are the maximum 3 mm of up-lifting height during replacement and the maximum required time of 30 minutes. Four separated spherical bearings are manufactured and replaced the existing bearings of a railway bridge in service and the replacing tests was performed. The number of the tests is two and the target of maximum 3 mm and 30 minutes was satisfied.

  • PDF

홍수시 얕은기초의 세굴위험도 평가 사례연구 (A Case Study of Scour Vulnerability Evaluation for Shallow Foundations during Floods)

  • 박재현;이주형;정문경;곽기석
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.59-62
    • /
    • 2008
  • Scour vulnerability evaluation for shallow foundations was performed to assure bridge safety against scour in the national capital region. The case studies for 26 shallow foundations consisted of site investigation including boring test, bridge scour analysis for the design flood, bearing capacity evaluation of the bridge foundation before and after scour, and comprehensive evaluation of bridge scour vulnerability. Bridge scour vulnerability was determined based on the interdisciplinary concept considering predicted scour depth for the design floods and bearing capacity of foundation as well as dimensions of foundation. Nine of 26 shallow foundations showed the potential future vulnerability to scour with significant decrease in the bearing capacity of foundations due to scour and the remaining 17 were expected to maintain their stability against scour.

  • PDF

Seismic control of high-speed railway bridge using S-shaped steel damping friction bearing

  • Guo, Wei;Wang, Yang;Zhai, Zhipeng;Du, Qiaodan
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.479-500
    • /
    • 2022
  • In this study, a new type of isolation bearing is proposed by combining S-shaped steel plate dampers (SSDs) with a spherical steel bearing, and the seismic control effect of a five-span standard high-speed railway bridge is investigated. The advantages of the proposed S-shaped steel damping friction bearing (SSDFB) are that it cannot only lengthen the structural periods, dissipate the seismic energy, but also prevent bridge unseating due to the restraint effectiveness of SSDs in the large relative displacements between the girders and piers. This study first presents a detailed description and working principle of the SSDFB. Then, mechanical modeling of the SSDFB was derived to fundamentally define its cyclic behavior and obtain key mechanical parameters. The numerical model of the SSDFB's critical component SSD was verified by comparing it with the experimental results. After that, parameter studies of the dimensions and number of SSDs, the friction coefficient, and the gap length of the SSDFBs were conducted. Finally, the longitudinal seismic responses of the bridge with SSDFBs were compared with the bridge with spherical bearing and spherical bearing with strengthened shear keys. The results showed that the SSDFB can not only significantly mitigate the shear force responses and residual displacement in bridge substructures but also can effectively reduce girder displacement and prevent bridge unseating, at a cost of inelastic deformation of the SSDs, which is easy to replace. In conclusion, the SSDFB is expected to be a cost-effective option with both multi-stage energy dissipation and restraint capacity, making it particularly suitable for seismic isolation application to high-speed railway bridges.

Two-stage damage identification for bridge bearings based on sailfish optimization and element relative modal strain energy

  • Minshui Huang;Zhongzheng Ling;Chang Sun;Yongzhi Lei;Chunyan Xiang;Zihao Wan;Jianfeng Gu
    • Structural Engineering and Mechanics
    • /
    • 제86권6호
    • /
    • pp.715-730
    • /
    • 2023
  • Broad studies have addressed the issue of structural element damage identification, however, rubber bearing, as a key component of load transmission between the superstructure and substructure, is essential to the operational safety of a bridge, which should be paid more attention to its health condition. However, regarding the limitations of the traditional bearing damage detection methods as well as few studies have been conducted on this topic, in this paper, inspired by the model updating-based structural damage identification, a two-stage bearing damage identification method has been proposed. In the first stage, we deduce a novel bearing damage localization indicator, called element relative MSE, to accurately determine the bearing damage location. In the second one, the prior knowledge of bearing damage localization is combined with sailfish optimization (SFO) to perform the bearing damage estimation. In order to validate the feasibility, a numerical example of a 5-span continuous beam is introduced, also the noise robustness has been investigated. Meanwhile, the effectiveness and engineering applicability are further verified based on an experimental simply supported beam and actual engineering of the I-40 Bridge. The obtained results are good, which indicate that the proposed method is not only suitable for simple structures but also can accurately locate the bearing damage site and identify its severity for complex structure. To summarize, the proposed method provides a good guideline for the issue of bridge bearing detection, which could be used to reduce the difficulty of the traditional bearing failure detection approach, further saving labor costs and economic expenses.

교량받침용 세라믹 마찰재 적용을 위한 실험적 연구 (Experimental Study on the Application of Ceramic Friction Materials for Bridge Bearing)

  • 박지훈;이정우;곽종원
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.527-534
    • /
    • 2023
  • 본 논문은 기존의 교량받침 마찰재인 PTFE의 내구성을 보완하고 낮은 마찰계수 발현 및 윤활제 미사용에서 마찰거동을 할 수 있는 세라믹 소재의 교량받침 적용을 위한 연구를 수행하였다. 세라믹 소재는 지르코니아계(ZrO2)를 설정하였으며, 조도계수에 따른 마찰거동 평가를 수행하였다. 조도계수는 0.8 및 0.027로 구분하였으며, 15 MPa 면압조건에서 평균마찰계수는 모두 0.16으로 산정되었다. 이후, 세라믹을 마찰재로 제작하여 교량받침에 적용하였으며, PTFE 적용 교량받침과의 압축실험 및 마찰실험을 통해 성능비교를 수행하였다. 압축실험에서 세라믹 및 PTFE 적용 교량받침은 하중 재하에 따라 이상적인 압축거동을 나타냈다. 세라믹 적용 교량받침은 파손 및 결함이 관찰되지 않았지만, PTFE 적용 교량받침에서는 윤활제 소실이 관찰되었다. 마찰거동을 통해 분석한 세라믹 적용 교량받침의 평균마찰계수는 0.16으로 나타났다. 세라믹의 물리적 및 화학적 특성의 고유 재료물성과 성능평가를 통해 도출된 우수한 역학적 특성 및 0.16 수준의 마찰계수는 마찰재로써 고려할 수 있는 가능성을 제시한다.

다경간 연속교에 대한 면진용 교좌장치의 내진성능 비교연구 (A comparative study on aseismic performances of base isolation systems for multi-span continuous bridge)

  • Park, Kyu-Sik;Lee, Chong-Heon;Lee, In-Won
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.383-390
    • /
    • 2001
  • Various base isolation systems, which are widely used, are compared for aseismic performances of multi-span continuous bridge. They are the P-F, RB, LRB, R-FBI and EDF systems. Sensitivity analyses are carried out to determine the design parameters of various devices. The design parameters, natural period of the isolated bridge and friction coefficient of the bearing, are determined by the reciprocal relationship between displacement and bending moment of the structure. Then the relative effectiveness of the bearings is described. Bridge with the R-FBI system shows the smallest peak displacement of deck whereas bridge with the EDF system shows the smallest peak bending moment of the lower end of pier in numerical examples. Furthermore, the peak responses of bridge with the friction type bearing are less sensitive to substantial variations in the frequency range and intensity of the ground excitation than those with the rubber type bearing.

  • PDF

IPC 거더 연속교의 실교량 내하력 평가 연구 (Load Bearing Capacity Evaluation of Continuous IPC Girder Bridge.)

  • 한만엽;황의승;진경석;강상훈;신재우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.475-478
    • /
    • 2005
  • This study was performed to evaluate about load bearing capacity of continuos IPC Girder Bridge under and after Construction. This is Ichi-1 Bridge that is 2-40m span continuous bridge on a extension road through the Ichun and the Naesa. The result of static loading test to use a 25ton truck after construction, deflection ratio is 0.64 that is $35\%$ and average of response ratio is 0.48$\~$0.89 that is less than theoretical value. The result of dynamic loading test, the number of proper vibrations is 3.06Hz that is like theoretical value 3.61Hz, the modulus of impact is 0.235 that is bigger than specification 0.19. the load bearing capacity is minimum DB-40 that is so big value. In the result, continuos IPC Girder Bridge is safe in short period. we will evaluate long period behavior of continuos IPC Girder Bridge.

  • PDF

교량용 내진 받침의 동특성 실험 결과를 이용한 교량의 해석 (Dynamic Analysis for Bridge Using the Experimental Results of Hysteretic Damping Bearing and Dynapot)

  • 윤정방;박동욱;이동하;안창모
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.465-474
    • /
    • 2001
  • Base Isolation system is an effective design strategy that provides a practical substitute for the seismic design of bridge. In this study, the dynamic tests was performed on HDB (Hysteretic Damping Bearing) and Dynapot. Then, the dynamic analysis was carried out for a bridge using the experimental results to estimate the seismic performance of bearings. Analysis for bridge was performed for four types of earthquake loadings. The result of dynamic test and theoretical analysis indicate that the performance of HDB and Dynapot is appropriate for the earthquake loading.

  • PDF