Dynamic Analysis for Bridge Using the Experimental Results of Hysteretic Damping Bearing and Dynapot

교량용 내진 받침의 동특성 실험 결과를 이용한 교량의 해석

  • 윤정방 (한국과학기술원 토목공학과) ;
  • 박동욱 (한국과학기술원 토목공학과) ;
  • 이동하 (㈜에스코테크놀로지) ;
  • 안창모 (㈜에스코테크놀로지)
  • Published : 2001.04.01

Abstract

Base Isolation system is an effective design strategy that provides a practical substitute for the seismic design of bridge. In this study, the dynamic tests was performed on HDB (Hysteretic Damping Bearing) and Dynapot. Then, the dynamic analysis was carried out for a bridge using the experimental results to estimate the seismic performance of bearings. Analysis for bridge was performed for four types of earthquake loadings. The result of dynamic test and theoretical analysis indicate that the performance of HDB and Dynapot is appropriate for the earthquake loading.

Keywords