• Title/Summary/Keyword: Breast images

Search Result 234, Processing Time 0.023 seconds

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

Estimation Carbon Storage of Urban Street trees Using UAV Imagery and SfM Technique (UAV 영상과 SfM 기술을 이용한 가로수의 탄소저장량 추정)

  • Kim, Da-Seul;Lee, Dong-Kun;Heo, Han-Kyul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.6
    • /
    • pp.1-14
    • /
    • 2019
  • Carbon storage is one of the regulating ecosystem services provided by urban street trees. It is important that evaluating the economic value of ecosystem services accurately. The carbon storage of street trees was calculated by measuring the morphological parameter on the field. As the method is labor-intensive and time-consuming for the macro-scale research, remote sensing has been more widely used. The airborne Light Detection And Ranging (LiDAR) is used in obtaining the point clouds data of a densely planted area and extracting individual trees for the carbon storage estimation. However, the LiDAR has limitations such as high cost and complicated operations. In addition, trees change over time they need to be frequently. Therefore, Structure from Motion (SfM) photogrammetry with unmanned Aerial Vehicle (UAV) is a more suitable method for obtaining point clouds data. In this paper, a UAV loaded with a digital camera was employed to take oblique aerial images for generating point cloud of street trees. We extracted the diameter of breast height (DBH) from generated point cloud data to calculate the carbon storage. We compared DBH calculated from UAV data and measured data from the field in the selected area. The calculated DBH was used to estimate the carbon storage of street trees in the study area using a regression model. The results demonstrate the feasibility and effectiveness of applying UAV imagery and SfM technique to the carbon storage estimation of street trees. The technique can contribute to efficiently building inventories of the carbon storage of street trees in urban areas.

A Study on the Types and Aesthetic Characteristics of Trompe Lœil Expressed in Modern Fashion Since 2010 (2010년 이후 현대 패션에 표현된 트롱프뢰유의 유형과 미적 특성에 관한 연구)

  • Kim, Kyung-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.18 no.2
    • /
    • pp.221-236
    • /
    • 2016
  • The purpose of this study is to make a contribution to the development of creative fashion culture through the expansion of creative fields in the fashion design area and also the combination of fashion and art techniques, by classifying the cases of Trompe $L{\oe}il$ expressed in modern fashion, and also analyzing its aesthetic characteristics. Conducting the qualitative research through the literature study and the analysis of design cases, it targeted the women's wear collections of Paris, Milan, London, and New York, limiting its range from S/S 2010 to F/W 2015. The results are as follows: First, based on the preceding research, the types of Trompe $L{\oe}il$ expressed in modern fashion were shown as realistic expression of clothing, movement of daily objects, double images, and application of human body. Second, the aesthetic characteristics of Trompe $L{\oe}il$ based on its expression types were deconstruction, avant-garde, and amusements. The deconstruction was expressed in the expression type of Trompe $L{\oe}il$ such as freedom of materials using digital printing technique, change in the position of clothes, and movement of daily items using collage technique by collecting objets like daily items or waste. The avant-garde was expressed by switching/overlapping in and out of clothes, intentionally exposing some body parts like breast or torso, displacing body parts, and moving daily items. The amusements was shown by realistically expressing accessories or details of clothes using digital printing technique, or moving daily items such as book and fork.

  • PDF

A Case Study on the Development of Patient Clothes Designs -Focused on General Patient Pajamas and Obstetrics and Gynecology Gowns of Korea University Medical Center- (환자복 디자인 개발에 관한 사례 연구 -고려대학교 의료원의 일반 환자복과 산부인과용 가운을 중심으로-)

  • Lee, Yhe-Young;Lee, Yoon-Jung;Seong, Hwa-Kyung
    • Journal of the Korean Home Economics Association
    • /
    • v.44 no.12
    • /
    • pp.9-18
    • /
    • 2006
  • A case study was conducted on the development of patient clothes designs at the Korea University Medical Center, in order to provide an example of patient clothes designs which meet the hospital identity and the demands of patients and nurses. In this study, we focused on general patient pajamas and one-piece gowns worn in the obstetrics and gynecology department. A scientific and systematic design approach consisting of the following four steps was conducted in the designing process: needs assessment, design direction establishment, design presentation, and final decision. For the first step, focused group interviews and a survey were conducted to identify the needs of the patients and nurses. According to the results of the first step, 3 fabric patterns with light, modern, rhythmic, modest and ordinary images were designed utilizing the university and hospital symbols and logotypes. Fixed forms with realistic and geometric characteristics and colors, including white, yellow, blue, grey, and pink were selected to deliver the preferred image. Each fabric pattern was made in male and female versions of the color sets. The following styles of patient clothes were made with the 3 fabric samples: general patient pajamas with a U-neckline, 9/10-length sleeves and ankle-length pants, a full-length sleeved gown with openings for breast-feeding, and a gown with a deep back-neckline and button fastening. Different sizing systems for males and females were recommended for the production.

Detection of Mass on Dense Mammogram (고밀도 유방영상에서 종양의 추출)

  • Yu, Seung-Hwa;No, Seung-Mu;Park, Jong-Won
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.6
    • /
    • pp.721-734
    • /
    • 2001
  • This paper proposed automated methods for the detection of breast mass. We analysed characteristic of the mass by using the features on mammograms. The homogeneity was used to distinguish mass and abnormal homogeneous tissue from the Cooper's ligament and multiple threshold method was used to deal with the high density candidates. By using the 8-connectivity, the first step candidates were selected. We generated the dualistic images of each candidate in which we regard the gray value as topographic height information. From these candidates, the second candidates were selected by comparing the circularity and the distribution rates. The final detection was done with the method in which we generated the template of each candidate and compared each other. From these methods, we grade the order from the candidate. We applied the algorithm to the 136 mammograms and compared to the radiologist's outlines of the leisions. The detection resulted that the sensitivity of the proposed methods was 93.38% and 97.63% FP(False positive) which we can segmented mass in the first grade in the 124 cases.

  • PDF

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Synthesis and evaluation of 64Cu-labeled avidin for lymph node imaging

  • Kang, Choong Mo;Kim, Hyunjung;Lee, Yong Jin;Choe, Yearn Seong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • Sentinel lymph node (SLN) imaging plays an important role in surgery of patients with breast cancer and melanoma. In this study, avidin (Av), a tetrameric protein glycosylated with mannose and N-acetylglucosamine molecules, was labeled with $^{64}Cu$ and then evaluated for LN imaging. $^{64}Cu$-Labeled $NeutrAvidin^{TM}$ (NAv), a non-glycosylated form of Av, was used for comparison. 1,4,7,10-Tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA)-conjugated Av and NAv were prepared from the corresponding proteins and DOTA-NHS ester, which were then labeled with copper-64 and purified using PD-10 columns. The numbers of DOTA molecules conjugated to Av and NAv were 4.9 and 3.3, respectively. [$^{64}Cu$]Cu-DOTA-conjugated Av and NAv were prepared in 93% and 73% radiochemical yields, respectively. In vitro serum stability study showed that copper-64 remained stable on all radiotracers for 24 h (>97%). MicroPET/CT images showed that high radioactivity was accumulated in LNs within 15 min after footpad-injection of radiotracers. Tissue distribution data of mice demonstrated significantly higher uptake in the popliteal (PO) LN than lumbar (LU) LN for $^{64}Cu$-labeled Av (relative % ID/g excluding the injection sites: 66.2% and 26.0%, respectively) compared with those of $^{64}Cu$-labeled NAv (43.0% and 49.2%, respectively). The results of this study suggest that mannose molecules on Av enabled the radiotracer to retain in the first LN after mouse footpad-injection.

Preoperative Prediction of Ductal Carcinoma in situ Underestimation of the Breast using Dynamic Contrast Enhanced and Diffusion-weighted Imaging (역동적 유방 자기공명 영상 및 확산 강조영상을 이용한 관상피내암종 저평가 수술전 예측)

  • Park, Mina;Kim, Eun-Kyung;Kim, Min Jung;Moon, Hee Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Objective: To investigate roles of dynamic contrast enhanced magnetic resonance (DCE MR) and diffusion-weighted (DW) imaging in preoperative prediction of underestimation of ductal carcinoma in situ (DCIS) ${\geq}2cm$ on US guided core needle biopsy. Materials and Methods: Twenty two patients with DCIS on US-guided 14 gauge core needle biopsy were included. Patients were divided into a group with and without DCIS underestimation based on histopathology. MR images including DCE and DW imaging were obtained with a 3.0-T MR. The lesion type (mass or non-mass), enhancement pattern, peak enhancement, and apparent diffusion coefficient (ADC) values of proven malignant masses were generated using software of CADstream and compared between two groups using Fisher's exact test and Mann Whitney test. Results: Eight patients were in the group with underestimation and 14 patients were in the group without underestimation. The lesion type and enhancement pattern were not different between two groups (P values = 1.000 and 0.613, respectively). The median peak enhancement of lesions with underestimation was 159.5%, higher than 133.5% of those without underestimation, but not significant (P value = 0.413). The median ADC value of lesions with underestimation was $1.26{\times}10^{-3}mm^2/sec$, substantially lower than $1.35{\times}10^{-3}mm^2/sec$ of those without underestimation (P value = 0.094). Conclusion: ADC values had the potential to preoperatively predict DCIS underestimation on US-guided core needle biopsy, although a large prospective series study should be conducted to confirm these results.

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Rotation Errors of Breast Cancer on 3D-CRT in TomoDirect (토모다이렉트 3D-CRT을 이용한 유방암 환자의 회전 오차)

  • Jung, Jae Hong;Cho, Kwang Hwan;Moon, Seong Kwon;Bae, Sun Hyun;Min, Chul Kee;Kim, Eun Seog;Yeo, Seung-Gu;Choi, Jin Ho;Jung, Joo-Yong;Choe, Bo Young;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.6-11
    • /
    • 2015
  • The purpose of this study was to analyze the rotational errors of roll, pitch, and yaw in the whole breast cancer treated by the three-dimensional radiation therapy (3D-CRT) using TomoDirect (TD). Twenty-patient previously treated with TD 3D-CRT was selected. We performed a retrospective clinical analysis based on 80 images of megavoltage computed tomography (MVCT) including the systematic and random variation with patient setup errors and treatment setup margin (mm). In addition, a rotational error (degree) for each patient was analyzed using the automatic image registration. The treatment margin of X, Y, and Z directions were 4.2 mm, 6.2 mm, and 6.4 mm, respectively. The mean value of the rotational error for roll, pitch, and yaw were $0.3^{\circ}$, $0.5^{\circ}$, $0.1^{\circ}$, and all of systematic and random error was within $1.0^{\circ}$. The errors of patient positioning with the Y and Z directions have generally been mainly higher than the X direction. The percentage in treatment fractions in less than $2^{\circ}$ at roll, pitch, and yaw are 95.1%, 98.8%, and 97.5%, respectively. However, the edge of upper and lower (i.e., bottom) based on the center of therapy region (point) will quite a possibility that it is expected to twist even longer as the length of treatment region. The patient-specific characters should be considered for the accuracy and reproducibility of treatment and it is necessary to confirm periodically the rotational errors, including patient repositioning and repeating MVCT scan.