• 제목/요약/키워드: Breast dose

검색결과 537건 처리시간 0.028초

Panduratin A Inhibits Cell Proliferation by Inducing G0/G1 Phase Cell Cycle Arrest and Induces Apoptosis in Breast Cancer Cells

  • Liu, Qiuming;Cao, Yali;Zhou, Ping;Gui, Shimin;Wu, Xiaobo;Xia, Yong;Tu, Jianhong
    • Biomolecules & Therapeutics
    • /
    • 제26권3호
    • /
    • pp.328-334
    • /
    • 2018
  • Because of the unsatisfactory treatment options for breast cancer (BC), there is a need to develop novel therapeutic approaches for this malignancy. One such strategy is chemotherapy using non-toxic dietary substances and botanical products. Studies have shown that Panduratin A (PA) possesses many health benefits, including anti-inflammatory, anti-bacterial, anti-oxidant and anticancer activities. In the present study, we provide evidence that PA treatment of MCF-7 BC cells resulted in a time- and dose-dependent inhibition of cell growth with an $IC_{50}$ of $15{\mu}M$ and no to little effect on normal human MCF-10A breast cells. To define the mechanism of these anti-proliferative effects of PA, we determined its effect critical molecular events known to regulate the cell cycle and apoptotic machinery. Immunofluorescence and flow cytometric analysis of Annexin V-FITC staining provided evidence for the induction of apoptosis. PA treatment of BC cells resulted in increased activity/expression of mitochondrial cytochrome C, caspases 7, 8 and 9 with a significant increase in the Bax:Bcl-2 ratio, suggesting the involvement of a mitochondrial-dependent apoptotic pathway. Furthermore, cell cycle analysis using flow cytometry showed that PA treatment of cells resulted in G0/G1 arrest in a dose-dependent manner. Immunoblot analysis data revealed that, in MCF-7 cell lines, PA treatment resulted in the dose-dependent (i) induction of $p21^{WAF1/Cip1}$ and p27Kip1, (ii) downregulation of Cyclin dependent kinase (CDK) 4 and (iii) decrease in cyclin D1. These findings suggest that PA may be an effective therapeutic agent against BC.

Mammography시 Thyroid에 미치는 산란선량에 관한 연구 (The Effect of Scattering Dose on the Thyroid During Mammography)

  • 이미화;동경래;박서주;황선광
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.826-830
    • /
    • 2010
  • This study examined the effect of the scattering dose on the thyroid during a mammography examination. One hundred subjects for a mammography examination were enrolled in this study. The average glandular dose (AGD) and thyroid scattering dose (TSD) were measured. Statistical analysis was carried out using the percentage, t-test and co-variance. The mean radiation exposure to the breast and thyroid was $1.08{\pm}0.16$ and $0.14{\pm}0.04$ mGy, respectively. The percentage TSD to the AGD was 31.19%. There was no difference between the Rt. and Lt., and CC to MLO, and radiation dose to the TSD was 13.78% of the breast. Therefore, the volume of radiation exposure to the thyroid was 54.12% in a single routine mammography examination. These results suggest that the TSD was increased by increasing radiation dose to the breast. A thyroid protector is considered necessary to decrease the level of radiation exposure.

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권12호
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

유방영상시스템에서 수학적 모의피폭체를 이용한 선량평가 (Dose Evaluation Using Mathematical Simulation of Radiation Exposure Body in Mammography System)

  • 이진수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.155-161
    • /
    • 2014
  • 유방촬영의 경우 대부분 양쪽 유방에 대해 연속촬영이 시행되고 있으며, 검사 시 규정하고 있는 3 mGy의 평균유선선량 보다 낮다 하더라도 추가 검사 및 연속촬영으로 인해 실제는 더 많은 선량을 받게 된다. 또한 검사 유방 외에 주변장기선량에 대해 인지하기 어렵다. 이에 본 연구는 유방영상시스템에서 수학적 모의피폭체를 이용하여 필터의 두께 변화(25, 30, $50{\mu}m$)에 따른 주변장기 선량분포와 검사측 유방을 기준으로 한 상대적 흡수선량률을 알아보았다. 그 결과 검사 반대 유방의 선량이 검사 유방을 기준으로 79.26~86.31%정도로 많은 영향이 미치는 것으로 나타났으며, Mo/Mo, W/Rh 조합에서 실제 사용되고 있는 필터 두께 $30{\mu}m$, $50{\mu}m$ 보다 얇은 $25{\mu}m$를 사용했을 때 검사 반대 유방과 주변장기의 상대적 흡수선량률이 낮게 나타났다.

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF

복부 방사선검사 자세가 유방선량에 미치는 영향 (Effects of Breast Dose on Plain Abdominal Position)

  • 주영철;김승혁
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

위장조영검사에서 수정체, 갑상선, 유방, 생식선에 대한 피폭선량 분석 (Analysis of Radiation Dose for Lens, Thyroid Gland, Breast, and Gonad on Upper Gastrointestinal Series)

  • 임병학;천권수
    • 한국방사선학회논문지
    • /
    • 제13권6호
    • /
    • pp.889-894
    • /
    • 2019
  • 위장조영검사는 X선을 사용하는 검사로 검사 부위 외의 다른 장기의 피폭이 발생한다. 위장조영검사에서 갑상선, 수정체, 유방, 생식선 등 생물학적으로 방사선감수성이 상대적으로 높은 표적장기가 주변에 분포되어있기 때문에 방사선 피폭에 대한 방어를 하는 것이 중요하다. 장기별 측정 깊이의 선택이 가능한 전신 팬톰을 제작하고 안구, 갑상선, 유방, 생식선의 방사선 피폭선량을 측정하였다. 투시만 시행하였을 경우 수정체, 갑상선, 유방, 생식선의 평균 피폭선량의 감소는 62.2%로 나타났고, 투시와 Spot 촬영을 동시에 시행하였을 경우 수정체, 갑상선, 유방, 생식선의 평균 피폭선량의 감소는 59.0%로 나타났다. 따라서 위장조영검사 시 수정체, 갑상선, 유방, 생식선의 차폐가 이들의 피폭선량 감소에 효과가 있었다는 것을 확인할 수 있었다. 제작한 인체 팬톰은 인체에 위치한 장기에 해당하는 높이를 조절할 수 있기 때문에 심부선량 측정에 사용될 수 있을 것이다.

반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가 (Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom)

  • 김정훈;이득희
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.523-528
    • /
    • 2020
  • 반려견의 사망원인 1위인 암 중 암컷에게서 가장 높은 발생률을 보이는 유방암을 대상으로 근접방사선치료 수행 시 모의모사를 이용한 흡수선량 측정을 바탕으로 적용성을 평가하고자 하였다. 모의모사를 위해 MCNPX 프로그램을 이용하였으며, 흡수선량 측정을 위해 소형견 크기의 수학적 팬텀을 제작 하였다. 흡수선량 측정결과 종양의 경우 192Ir에서 1.02E-12 Gy/#으로 흡수선량이 가장 높은 것으로 나타났으며, 내·외부 흡수선량에서도 동일한 경향성으로 나타났다. 따라서 반려견 유방암의 근접방사선치료 시 견종과 피폭을 고려한 적절한 선원의 선택이 고려되어야 될 것이다.

유방암 환자의 3D-CRT, TOMO 방법에 따른 선량 분포 평가 (Dosimetric Comparison of Three Dimensional Conformal Radiation Radiotherapy and Helical Tomotherapy Partial Breast Cancer)

  • 김대웅;김종원;최윤경;김정수;황재웅;정경식;최계숙
    • 대한방사선치료학회지
    • /
    • 제20권1호
    • /
    • pp.11-15
    • /
    • 2008
  • 목 적: 방사선치료계획에 있어서 정상조직과 치료부위의 선량 분포는 매우 중요하다. 이에 본원에서는 유방암 환자를 대상으로 Three-dimensional conformal radiation therapy (3D-CRT), Helical tomotherapy (TOMO)의 방법으로 방사선치료계획을 세웠으며 이에 선량분포를 분석하여 실제 임상에서의 적용여부를 알아보고자 한다. 대상 및 방법: 20명의(좌측: 10명, 우측: 10명) 유방보존절제술 환자를 대상으로 시행하였으며 방법으로는 같은 조건에서 3D-CRT는 Philips사의 Pinnacle을, TOMO는 TomoTherapy사의 TOMO Planning System을 이용해 치료계획을 세웠다. Dose-Volume Histogram (DVH)의 prescribed dose (PD)에 대한 PTV의 Homogeneity index (HI)와 Conformity index (CI)를 구하였고, 정상조직의 dose- volume 관계를 비교하였다. 결 과: Homogeneity index (HI)와 Conformity, index (CI)는 TOMO에서 우수한 결과를 나타났다. $V_{-50-IB-NPTV}$ (the percentage ipsilateral non-PTV breast volume that was delivered 50% of the prescribed dose)는 3D-CRT: 40.4%, TOMO: 18.3%, $V_{20-IL}$ (the average ipsilateral lung volume percentage receiving 20% of the prescribed dose)는 3D-CRT: 4.8%, TOMO: 14.2%, $V_{20-10H}$ (the average heart volume percentage delivered 20% and 10% of the prescribed dose in left breast cancer)는 3D-CRT: 1.6%, 3% TOMO: 9.7%, 26.3%의 결과를 보여준다. 결 론: 유방암 환자의 방사선치료계획 방법들은 PTV에서 원하는 선량분포를 보여줬다. 그러나 TOMO는 좋은 Homogeneity index (HI), Conformity index (CI)와 Breast를 보호하는 장점이 있는 반면에 Lung과 Heart에서는 많은 피폭선량이 있음을 알 수 있기에 TOMO의 방사선치료계획시 주의해야 할 점으로 사료된다.

  • PDF

Deep Inspiration Breath Holding을 적용한 유방암 세기변조방사선치료 시 위치잡이오차 분석을 통한 선량 평가 (Dosimetric Comparison of Setup Errors in Intensity Modulated Radiation Therapy with Deep Inspiration Breath Holding in Breast Cancer Radiation Therapy)

  • 함일식;조평곤;정강교
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.137-143
    • /
    • 2019
  • The aim of this study was analyzed the setup error of breast cancer patients in intensity modulated radiation therapy(IMRT) with deep inspiration breath holding(DIBH) and was analyzed the dose distribution due to setup error. A total of 45 breast cancer cases were performed a retrospective clinical analysis of setup error. In addition, the re-treatment planning was carried by shifting the setup error from the isocenter at the treatment. Based on this, the dose distribution of PTV and OARs was compared and analyzed. The 3D error for small breast group and medium breast group and large breast group were 3.1 mm and 3.7 mm and 4.1 mm, respectively. The difference between the groups was statistically significant(P=0.003). DVH results showed HI, CI for the PTV difference between standard treatment plan and re-treatment plan of 14.4%, 4%. The difference in $D_5$ and $V_{20}$ of the ipsilateral lung was 5.6%, 13% respectively. The difference in $D_5$ and $V_5$ of the heart of right breast cancer patients was 6.8%, 8% respectively. The difference in $D_5$, $V_{20}$ of the heart of left breast cancer patients was 7.2%, 23.5% respectively. In this study, there was a significant association between breast size and significant setup error in breast cancer patients with DIBH. In addition, it was found that the dose distribution of the PTV and OARs varied according to the setup error.